ASTM C686-90(2007)
(Test Method)Standard Test Method for Parting Strength of Mineral Fiber Batt- and Blanket-Type Insulation
Standard Test Method for Parting Strength of Mineral Fiber Batt- and Blanket-Type Insulation
SIGNIFICANCE AND USE
Tensile strength is a fundamental property associated with mineral fiber manufacture since it is influenced by the type of fiber, the deposition of fiber, the type and the amount of bonding agent, and the method of curing the resin to form a bonded insulation product. The test is an indication of product integrity and the ability of the product to be successfully handled and applied in the field.
SCOPE
1.1 This test method covers evaluation of strength in tension on mineral fiber batt- and blanket-type insulation products. It is useful for determining the comparative tensile properties of these products, specimens of which cannot be held by the more conventional clamp-type grips. This is a quality control method, and the results should not be used for design purposes. It is not normally used for board-type products.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
General Information
Relations
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:C686–90(Reapproved2007)
Standard Test Method for
Parting Strength of Mineral Fiber Batt- and Blanket-Type
Insulation
This standard is issued under the fixed designation C686; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 4. Apparatus
1.1 Thistestmethodcoversevaluationofstrengthintension 4.1 Constant Rate of Traverse Tension Test Unit of 50-lbf
on mineral fiber batt- and blanket-type insulation products. It is (223-N)capacitycalibratedinincrementsof0.1lbf(0.4N)and
useful for determining the comparative tensile properties of having a moving head speed of 12 in. (305 mm)/min or
these products, specimens of which cannot be held by the more equivalent (see Fig. 1).
conventional clamp-type grips. This is a quality control 4.2 Post-Type Grips with 1-in. (25.4-mm) diameter rods
method, and the results should not be used for design purposes. (see Fig. 2).
It is not normally used for board-type products. 4.3 Die for cutting specimens (see Fig. 3). The O-ring
1.2 This standard does not purport to address all of the specimen dimensions are 3 by 4.75 in. (76 by 120.6 mm) in
safety concerns, if any, associated with its use. It is the outside diameter, and 1 by 2.75 in. (25 by 69.8 mm) in inside
responsibility of the user of this standard to establish appro- diameter (see Fig. 4).
priate safety and health practices and determine the applica- 4.4 Balance to weigh to an accuracy of 0.01 g.
bility of regulatory limitations prior to use.
5. Test Specimen
2. Referenced Documents
5.1 The test specimen shall consist of the entire O-ring cut
2.1 ASTM Standards: from the full thickness of the product to be tested.
C167 TestMethodsforThicknessandDensityofBlanketor 5.2 Specimens shall not be cut from a product that varies in
Batt Thermal Insulations thickness 65 % from normal when tested in accordance with
E171 Specification for Atmospheres for Conditioning and Test Method C167.
Testing Flexible Barrier Materials 5.3 No specimen shall be tested that exhibits any obvious
E691 Practice for Conducting an Interlaboratory Study to damage in the insulation or that shows delamination within the
Determine the Precision of a Test Method insulation thickness.
3. Significance and Use 6. Conditioning
3.1 Tensile strength is a fundamental property associated 6.1 Condition the specimens for1hina room maintained at
with mineral fiber manufacture since it is influenced by the atmospheric conditions of 73.4 6 1.8°F (23 6 1°C) and 50 6
type of fiber, the deposition of fiber, the type and the amount of 2 % relative humidity in accordance with Specification E171.
bonding agent, and the method of curing the resin to form a
7. Procedure
bonded insulation product. The test is an indication of product
7.1 Weigh each specimen to the nearest 0.01 g and record
integrity and the ability of the product to be successfully
handled and applied in the field. the weight.
7.2 Attach the post-type grips to the tension test unit and
align the grips in the vertical plane.
This test method is under the jurisdiction ofASTM Committee C16 onThermal 7.3 Adjust the speed of the moving head to 12 in. (305
Insulation and is the direct responsibility of Subcommittee C16.32 on Mechanical
mm)/min.
Properties.
7.4 Set the stops of the moving head until the grips are
Current edition approved May 1, 2007. Published May 2007. Originally
approximately ⁄4 in. (6.3 mm) apart in the starting position.
published as approved in 1971. Last previous edition approved in 2001 as
C686 – 90 (2001). DOI: 10.1520/C0686-90R07.
7.5 Place the specimen on the post-type grip (higher density
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
side first if it is evident that such exists) so that both posts are
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
with
...







Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.