SIGNIFICANCE AND USE
The purpose of the methods, systems, and designs described in this practice is to reduce radiation exposures for occupants of residential buildings caused by radon and its progeny. The goal of mitigation is to maintain reduced radon concentrations in occupiable areas of buildings at levels as low as reasonably achievable. This practice includes sections on reducing radiation exposure caused by radon and its progeny for workers who install and repair radon mitigation systems. The goal for workers is to reduce exposures to radon and its progeny to levels as low as reasonably achievable.
The methods, systems, designs, and materials described here have been shown to have a high probability of success in mitigating radon in attached and detached residential buildings, three stories or less in height (see EPA, “Radon Reduction Techniques for Existing Detached Houses, Technical Guidance (Third Edition) for Active Soil Depressurization Systems”). Application of these methods does not, however, guarantee reduction of radon levels below any specific level, since performance will vary with site conditions, construction characteristics, weather, and building operation.
When applying this practice, contractors also shall conform to all applicable local, state, and federal regulations, and laws pertaining to residential building construction, remodeling, and improvement.
SCOPE
1.1 This practice describes methods for reducing radon entry into existing attached and detached residential buildings three stories or less in height. This practice is intended for use by trained, certified or licensed, or both, or otherwise qualified individuals.
1.2 These methods are based on radon mitigation techniques that have been effective in reducing radon levels in a wide range of residential buildings and soil conditions. These fan powered mitigation methods are listed in Appendix X1. More detailed information is contained in references cited throughout this practice.
1.3 This practice is intended to provide radon mitigation contractors with a uniform set of practices that will ensure a high degree of safety and the likelihood of success in retrofitting low rise residential buildings with radon mitigation systems.
1.4 The methods described in this practice apply to currently occupied or formerly occupied residential buildings, including buildings converted or being converted to residential use, as well as residential buildings changed or being changed by addition(s) or alteration(s), or both. The radon reduction activities performed on new dwellings, while under construction, before occupancy, and for up to one year after occupancy, are covered by Guide E1465.
1.5 This practice also is intended as a model set of practices, which can be adopted or modified by state and local jurisdictions, to fulfill objectives of their specific radon contractor certification or licensure programs. Radon mitigation performed in accordance with this practice is considered ordinary repair.
1.6 The methods addressed in this practice include the following categories of contractor activity: general practices, building investigation, systems design, systems installation, materials, monitors and labeling, post-mitigation testing, and documentation.
1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 for specific safety hazards.
General Information
Relations
Buy Standard
Standards Content (Sample)
NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation:E2121–11
Standard Practice for
Installing Radon Mitigation Systems in Existing Low-Rise
1
Residential Buildings
This standard is issued under the fixed designation E2121; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 1.7 The values stated in inch-pound units are to be regarded
as standard. The values given in parentheses are mathematical
1.1 This practice describes methods for reducing radon
conversions to SI units that are provided for information only
entry into existing attached and detached residential buildings
and are not considered standard.
three stories or less in height. This practice is intended for use
1.8 This standard does not purport to address all of the
by trained, certified or licensed, or both, or otherwise qualified
safety concerns, if any, associated with its use. It is the
individuals.
responsibility of the user of this standard to establish appro-
1.2 Thesemethodsarebasedonradonmitigationtechniques
priate safety and health practices and determine the applica-
that have been effective in reducing radon levels in a wide
bility of regulatory limitations prior to use. See Section 6 for
range of residential buildings and soil conditions. These fan
specific safety hazards.
powered mitigation methods are listed in Appendix X1. More
detailedinformationiscontainedinreferencescitedthroughout
2. Referenced Documents
this practice.
2
2.1 ASTM Standards:
1.3 This practice is intended to provide radon mitigation
E631 Terminology of Building Constructions
contractors with a uniform set of practices that will ensure a
E1465 Practice for Radon Control Options for the Design
high degree of safety and the likelihood of success in retrofit-
and Construction of New Low-Rise Residential Buildings
ting low rise residential buildings with radon mitigation
E1745 SpecificationforPlasticWaterVaporRetardersUsed
systems.
in Contact with Soil or Granular Fill under Concrete Slabs
1.4 The methods described in this practice apply to cur-
2.2 Government Publications:
rently occupied or formerly occupied residential buildings,
EPA “Asbestos School Hazard Abatement Reauthorization
including buildings converted or being converted to residential
3
Act,” regulation 40 CFR Part 763, Subpart E.
use, as well as residential buildings changed or being changed
EPA “A Citizen’s Guide to Radon (Second Edition),” EPA
by addition(s) or alteration(s), or both. The radon reduction
3
402-K92-001, May 1992.
activities performed on new dwellings, while under construc-
EPA “Consumer’s Guide to Radon Reduction,” EPA 402-
tion, before occupancy, and for up to one year after occupancy,
3
K92-003, August 1992.
are covered by Guide E1465.
EPA “Handbook, Sub-Slab Depressurization for Low-
1.5 Thispracticealsoisintendedasamodelsetofpractices,
Permeability Fill Material,” EPA/625/6-91/029, July
which can be adopted or modified by state and local jurisdic-
3
1991.
tions, to fulfill objectives of their specific radon contractor
EPA “Home Buyers and Sellers Guide,” EPA 402–K-
certification or licensure programs. Radon mitigation per-
3
00–008, July 2000.
formed in accordance with this practice is considered ordinary
EPA “National Emission Standard for Asbestos,” 40 CFR
repair.
3
61, Subpart M.
1.6 The methods addressed in this practice include the
EPA “ Radon Mitigation Standards,” EPA 402-R-93-078,
following categories of contractor activity: general practices,
3
April 1994.
building investigation, systems design, systems installation,
EPA “Radon Reduction Techniques for Existing Detached
materials, monitors and labeling, post-mitigation testing, and
Houses, Technical Guidance (Second Edition),” EPA/
documentation.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
1
This practice is under the jurisdiction of ASTM Committee E06 on Perfor- contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
mance of Buildings and is the direct responsibility of Subcommittee E06.41 onAir Standards volume information, refer to the standard’s Document Summary page on
Leakage and Ventilation Performance. the ASTM website.
3
Current edition approved Nov. 1, 2011. Published December 2011. Originally Available from United States Environmental Protection Agency (EPA), Ariel
approved in 2001. Last previous edition approved in 2009 as E2121 – 09. DOI: Rios Bldg., 1200 Pennsylvania Ave., NW, Washington, DC 20460, http://
10.1520/E2121-11. www.epa.gov.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1
---------------------- Page: 1 ------
...
This document is not anASTM standard and is intended only to provide the user of anASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation:E2121–09 Designation: E2121 – 11
Standard Practice for
Installing Radon Mitigation Systems in Existing Low-Rise
1
Residential Buildings
This standard is issued under the fixed designation E2121; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope
1.1 This practice describes methods for reducing radon entry into existing attached and detached residential buildings three
storiesorlessinheight.Thispracticeisintendedforusebytrained,certifiedorlicensed,orboth,orotherwisequalifiedindividuals.
1.2 These methods are based on radon mitigation techniques that have been effective in reducing radon levels in a wide range
of residential buildings and soil conditions. These fan powered mitigation methods are listed in Appendix X1. More detailed
information is contained in references cited throughout this practice.
1.3 This practice is intended to provide radon mitigation contractors with a uniform set of practices that will ensure a high
degree of safety and the likelihood of success in retrofitting low rise residential buildings with radon mitigation systems.
1.4 The methods described in this practice apply to currently occupied or formerly occupied residential buildings, including
buildings converted or being converted to residential use, as well as residential buildings changed or being changed by addition(s)
or alteration(s), or both. The radon reduction activities performed on new dwellings, while under construction, before occupancy,
and for up to one year after occupancy, are covered by Guide E1465.
1.5 This practice also is intended as a model set of practices, which can be adopted or modified by state and local jurisdictions,
tofulfillobjectivesoftheirspecificradoncontractorcertificationorlicensureprograms.Radonmitigationperformedinaccordance
with this practice is considered ordinary repair.
1.6 The methods addressed in this practice include the following categories of contractor activity: general practices, building
investigation, systems design, systems installation, materials, monitors and labeling, post-mitigation testing, and documentation.
1.7
1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use. See Section 6 for specific safety hazards.
2. Referenced Documents
2
2.1 ASTM Standards:
E631 Terminology of Building Constructions
E1465 Practice for Radon Control Options for the Design and Construction of New Low-Rise Residential Buildings
E1745 Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs
2.2 Government Publications:
3
EPA “Asbestos School Hazard Abatement Reauthorization Act,” regulation 40 CFR Part 763, Subpart E.
3
EPA “A Citizen’s Guide to Radon (Second Edition),” EPA 402-K92-001, May 1992.
3
EPA “Consumer’s Guide to Radon Reduction,” EPA 402-K92-003, August 1992.
3
EPA “Handbook, Sub-Slab Depressurization for Low-Permeability Fill Material,” EPA/625/6-91/029, July 1991.
3
EPA “Home Buyers and Sellers Guide,” EPA 402–K-00–008, July 2000.
3
EPA “National Emission Standard for Asbestos,” 40 CFR 61, Subpart M.
3
EPA “ Radon Mitigation Standards,” EPA 402-R-93-078, April 1994.
1
This practice is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.41 on Air Leakage
and Ventilation Performance.
Current edition approved Nov. 1, 2009.2011. Published December 2009.2011. Originally approved in 2001. Last previous edition approved in 20082009 as E2121 – 089.
DOI: 10.1520/E2121-09.10.1520/E2121-11.
2
For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
3
Available from United States Environmental Protection Agency (EPA), Ariel Rios Bldg., 1200 Pennsylvania Ave., NW
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.