Standard Practice for Application of Class PB Exterior Insulation and Finish Systems (EIFS) and EIFS with Drainage

SIGNIFICANCE AND USE
4.1 This practice provides minimum requirements for the application of Class PB EIFS and EIFS with Drainage (see Specification E2568). The requirements for materials, mixtures, and details shall be contained in the project plans and specifications. See Guide E1825 for guidance.
SCOPE
1.1 This practice covers the minimum requirements and procedures for field or prefabricated application of Class PB Exterior Insulation and Finish Systems (EIFS) and EIFS with Drainage. Class PB EIFS are systems applied over insulation board, in which the base coat ranges from not less than 1/16 in. (1.6 mm) to 1/4 in. (6.4 mm) in dry thickness, depending upon the number of nonmetallic reinforcing mesh layers encapsulated in the base coat (see Specification E2568). The base coat is then covered with a finish coat of varying thickness in a variety of textures and colors. EIFS with Drainage provides a mechanism to drain incidental moisture  
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.  
1.3 The text of this practice references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as a requirement of the standard.  
1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

General Information

Status
Historical
Publication Date
31-Aug-2013
Current Stage
Ref Project

Relations

Buy Standard

Standard
ASTM C1397-13 - Standard Practice for Application of Class PB Exterior Insulation and Finish Systems (EIFS) and EIFS with Drainage
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
REDLINE ASTM C1397-13 - Standard Practice for Application of Class PB Exterior Insulation and Finish Systems (EIFS) and EIFS with Drainage
English language
9 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C1397 − 13
Standard Practice for
Application of Class PB Exterior Insulation and Finish
1
Systems (EIFS) and EIFS with Drainage
This standard is issued under the fixed designation C1397; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope* C150 Specification for Portland Cement
C1063 Specification for Installation of Lathing and Furring
1.1 This practice covers the minimum requirements and
to Receive Interior and Exterior Portland Cement-Based
procedures for field or prefabricated application of Class PB
Plaster
Exterior Insulation and Finish Systems (EIFS) and EIFS with
C1177/C1177M Specification for Glass Mat Gypsum Sub-
Drainage. Class PB EIFS are systems applied over insulation
strate for Use as Sheathing
1
board, in which the base coat ranges from not less than ⁄16 in.
C1186 Specification for Flat Fiber-Cement Sheets
1
(1.6 mm) to ⁄4 in. (6.4 mm) in dry thickness, depending upon
C1278/C1278M Specification for Fiber-Reinforced Gypsum
the number of nonmetallic reinforcing mesh layers encapsu-
Panel
lated in the base coat (see Specification E2568). The base coat
C1280 Specification for Application of Exterior Gypsum
is then covered with a finish coat of varying thickness in a
Panel Products for Use as Sheathing
variety of textures and colors. EIFS with Drainage provides a
C1325 Specification for Non-Asbestos Fiber-Mat Rein-
mechanism to drain incidental moisture
forced Cementitious Backer Units
1.2 The values stated in inch-pound units are to be regarded
C1382 Test Method for DeterminingTensileAdhesion Prop-
as standard. The values given in parentheses are mathematical
erties of Sealants When Used in Exterior Insulation and
conversions to SI units that are provided for information only
Finish Systems (EIFS) Joints
and are not considered standard.
C1396/C1396M Specification for Gypsum Board
C1472 Guide for Calculating Movement and Other Effects
1.3 The text of this practice references notes and footnotes
which provide explanatory material. These notes and footnotes When Establishing Sealant Joint Width
C1481 Guide for Use of Joint Sealants with Exterior Insu-
(excluding those in tables and figures) shall not be considered
as a requirement of the standard. lation and Finish Systems (EIFS)
E1825 Guide for Evaluation of Exterior Building Wall
1.4 This standard may involve hazardous materials,
Materials, Products, and Systems
operations, and equipment. This standard does not purport to
E2110 Terminology for Exterior Insulation and Finish Sys-
address all of the safety concerns, if any, associated with its
tems (EIFS)
use. It is the responsibility of the user of this standard to
E2430 Specification For Expanded Polystyrene (“EPS”)
establish appropriate safety and health practices and deter-
Thermal Insulation Boards for Use in Exterior Insulation
mine the applicability of regulatory limitations prior to use.
and Finish Systems (“EIFS”)
E2568 Specification for PB Exterior Insulation and Finish
2. Referenced Documents
Systems
2
2.1 ASTM Standards:
E2570 Test Methods for Evaluating Water-Resistive Barrier
C11 Terminology Relating to Gypsum and Related Building
(WRB) Coatings Used under Exterior Insulation and
Materials and Systems
Finish Systems (EIFS) or EIFS with Drainage
1
This practice is under the jurisdiction of ASTM Committee C11 on Gypsum 3. Terminology
and Related Building Materials and Systems and is the direct responsibility of
3.1 Definitions used in this standard shall be in accordance
Subcommittee C11.05 on Application of Exterior Insulating and Finish Systems and
Related Products. with Terminologies C11 and E2110.
Current edition approved Sept. 1, 2013. Published October 2013. Originally
approved in 1998. Last previous edition approved in 2009 as C1397 – 09. DOI:
4. Significance and Use
10.1520/C1397-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or
4.1 This practice provides minimum requirements for the
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
application of Class PB EIFS and EIFS with Drainage (see
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. Specification E2568). The requirements for materials,
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1397 − 13
mixtures,anddetailsshallbecontainedintheprojectplansand 10. Environmental Conditions
specifications. See Guide E1825 for guidance.
10.1
...

This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Because
it may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
of the standard as published by ASTM is to be considered the official document.
Designation: C1397 − 09 C1397 − 13
Standard Practice for
Application of Class PB Exterior Insulation and Finish
1
Systems (EIFS) and EIFS with Drainage
This standard is issued under the fixed designation C1397; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope*
1.1 This practice covers the minimum requirements and procedures for field or prefabricated application of Class PB Exterior
Insulation and Finish Systems (EIFS) and EIFS with Drainage. Class PB EIFS are systems applied over insulation board, in which
1 1
the base coat ranges from not less than ⁄16 in. (1.6 mm) to ⁄4 in. (6.4 mm) in dry thickness, depending upon the number of
nonmetallic reinforcing mesh layers encapsulated in the base coat (see Specification E2568). The base coat is then covered with
a finish coat of varying thickness in a variety of textures and colors. EIFS with Drainage provides a mechanism to drain incidental
moisture
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical
conversions to SI units that are provided for information only and are not considered standard.
1.3 The text of this practice references notes and footnotes which provide explanatory material. These notes and footnotes
(excluding those in tables and figures) shall not be considered as a requirement of the standard.
1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all
of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2
2.1 ASTM Standards:
C11 Terminology Relating to Gypsum and Related Building Materials and Systems
C150 Specification for Portland Cement
C1063 Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster
C1177/C1177M Specification for Glass Mat Gypsum Substrate for Use as Sheathing
C1186 Specification for Flat Fiber-Cement Sheets
C1278/C1278M Specification for Fiber-Reinforced Gypsum Panel
C1280 Specification for Application of Exterior Gypsum Panel Products for Use as Sheathing
C1325 Specification for Non-Asbestos Fiber-Mat Reinforced Cementitious Backer Units
C1382 Test Method for Determining Tensile Adhesion Properties of Sealants When Used in Exterior Insulation and Finish
Systems (EIFS) Joints
C1396/C1396M Specification for Gypsum Board
C1472 Guide for Calculating Movement and Other Effects When Establishing Sealant Joint Width
C1481 Guide for Use of Joint Sealants with Exterior Insulation and Finish Systems (EIFS)
E1825 Guide for Evaluation of Exterior Building Wall Materials, Products, and Systems
E2110 Terminology for Exterior Insulation and Finish Systems (EIFS)
E2430 Specification For Expanded Polystyrene (“EPS”) Thermal Insulation Boards for Use in Exterior Insulation and Finish
Systems (“EIFS”)
E2568 Specification for PB Exterior Insulation and Finish Systems
1
This practice is under the jurisdiction of ASTM Committee C11 on Gypsum and Related Building Materials and Systems and is the direct responsibility of Subcommittee
C11.05 on Application of Exterior Insulating and Finish Systems and Related Products.
Current edition approved July 15, 2009Sept. 1, 2013. Published August 2009October 2013. Originally approved in 1998. Last previous edition approved in 20052009 as
C1397 – 05.C1397 – 09. DOI: 10.1520/C1397-09.10.1520/C1397-13.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards
volume information, refer to the standard’s Document Summary page on the ASTM website.
*A Summary of Changes section appears at the end of this standard
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1397 − 13
E2570 Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems
(EIFS) or EIFS with Drainage
3. Terminology
3.1 Definitions used in this standard shall be in accordance with Terminologies C11
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.