Standard Test Methods for Measuring the Reactivity of Supplementary Cementitious Materials by Isothermal Calorimetry and Bound Water Measurements

SIGNIFICANCE AND USE
5.1 These test methods are used to assess the chemical (pozzolanic or hydraulic) reactivity of SCMs over a curing time of 7 days. The results of these test methods can be used to estimate the potential contribution of a SCM to the development of strength, or other properties such as lower permeability, when used with portland cement. However, the test results are not a substitute for direct measurement of the same properties of concrete made with that SCM.  
5.2 The calcium hydroxide, calcium carbonate, potassium sulfate, and potassium hydroxide are combined in proportions to provide a paste where the dissolved ions from these components simulate the pore solution in a portland cement system.  
5.3 The pastes are cured at 40 °C to accelerate the rate of reaction of slowly reactive SCMs.  
5.4 These test methods allow for the direct measurement of the hydraulic or pozzolanic reactivity of a potential SCM. These test methods are also suitable for screening purposes in the development and research of SCMs for use in portland cement-based systems. Furthermore, these test methods may be used in manufacturing control of portland cement-based products for assessing the hydraulic or pozzolanic reactivity of a SCM component.  
5.5 These test methods are based on the work by Avet et al.4 and are a result of the work of RILEM Technical Committee 267 – Tests for Reactivity of Supplementary Cementitious Materials.5 The test methods are based on established correlations between strength development and evolution of heat and binding of water for SCMs covered by Specifications C618, C989/C989M, and C1240, and by Guide C1709. For other alternative SCMs, the validity of such correlations has not been established.  
5.6 There is no requirement to use Method A and Method B for a given application. In many instances the choice is based on the user’s determination of available equipment. Method A can also provide an indication of rate of reactivity because measurements are taken con...
SCOPE
1.1 These two alternative test methods are used to assess the chemical reactivity of a supplementary cementitious material (SCM) as determined by measurements of cumulative heat release or bound water content of hydrated pastes composed of the SCM, calcium hydroxide, calcium carbonate, potassium sulfate, and potassium hydroxide cured at 40 °C for 3 and 7 days.  
1.1.1 These two test methods do not distinguish between hydraulic and pozzolanic reactivity.  
1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.  
1.3 The text of the standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.  
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.)2  
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

General Information

Status
Published
Publication Date
31-May-2020
Current Stage
Ref Project

Buy Standard

Standard
ASTM C1897-20 - Standard Test Methods for Measuring the Reactivity of Supplementary Cementitious Materials by Isothermal Calorimetry and Bound Water Measurements
English language
5 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Designation: C1897 − 20
Standard Test Methods for
Measuring the Reactivity of Supplementary Cementitious
Materials by Isothermal Calorimetry and Bound Water
1
Measurements
This standard is issued under the fixed designation C1897; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (´) indicates an editorial change since the last revision or reapproval.
1. Scope 2. Referenced Documents
3
2.1 ASTM Standards:
1.1 Thesetwoalternativetestmethodsareusedtoassessthe
C114 Test Methods for Chemical Analysis of Hydraulic
chemical reactivity of a supplementary cementitious material
Cement
(SCM) as determined by measurements of cumulative heat
C125 Terminology Relating to Concrete and Concrete Ag-
release or bound water content of hydrated pastes composed of
gregates
the SCM, calcium hydroxide, calcium carbonate, potassium
C311/C311M Test Methods for Sampling and Testing Fly
sulfate, and potassium hydroxide cured at 40 °C for 3 and 7
Ash or Natural Pozzolans for Use in Portland-Cement
days.
Concrete
1.1.1 These two test methods do not distinguish between
C618 Specification for Coal Fly Ash and Raw or Calcined
hydraulic and pozzolanic reactivity.
Natural Pozzolan for Use in Concrete
1.2 The values stated in SI units are to be regarded as the C989/C989M Specification for Slag Cement for Use in
standard. No other units of measurement are included in this
Concrete and Mortars
standard. C1240 Specification for Silica Fume Used in Cementitious
Mixtures
1.3 The text of the standard refers to notes and footnotes
C1702 Test Method for Measurement of Heat of Hydration
that provide explanatory material. These notes and footnotes
of Hydraulic Cementitious Materials Using Isothermal
(excluding those in tables and figures) shall not be considered
Conduction Calorimetry
as requirements of this standard.
C1709 Guide for Evaluation of Alternative Supplementary
1.4 This standard does not purport to address all of the
Cementitious Materials (ASCM) for Use in Concrete
safety concerns, if any, associated with its use. It is the C1738/C1738M Practice for High-Shear Mixing of Hydrau-
responsibility of the user of this standard to establish appro-
lic Cement Pastes
priate safety, health, and environmental practices and deter- E11 Specification for Woven Wire Test Sieve Cloth and Test
mine the applicability of regulatory limitations prior to use.
Sieves
(Warning—Fresh hydraulic cementitious mixtures are caustic
3. Terminology
and may cause chemical burns to skin and tissue upon
2
prolonged exposure.)
3.1 Definitions:
1.5 This international standard was developed in accor-
3.1.1 For definitions of terms used in these test methods,
dance with internationally recognized principles on standard-
refer to Terminology C125.
ization established in the Decision on Principles for the
3.2 Definitions of Terms Specific to This Standard:
Development of International Standards, Guides and Recom-
3.2.1 chemically bound water, n—water in hardened cement
mendations issued by the World Trade Organization Technical paste that has reacted and is part of the structure of hydrated
Barriers to Trade (TBT) Committee.
reaction products.
3.2.1.1 Discussion—In these test methods, bound water is
taken as the mass loss when a paste specimen dried previously
at 40 °C is heated in a furnace to 350 °C. Some raw natural
1
These test methods are under the jurisdiction of ASTM Committee C09 on
Concrete and ConcreteAggregates and is the direct responsibility of Subcommittee
C09.24 on Supplementary Cementitious Materials.
3
Current edition approved June 1, 2020. Published August 2020. DOI: 10.1520/ For referenced ASTM standards, visit the ASTM website, www.astm.org, or
C1897-20. contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
2
Section on Safety Precautions, Manual of Aggregate and Concrete Testing, Standards volume information, refer to the standard’s Document Summary page on
Annual Book of ASTM Standards, Vol. 04.02. the ASTM website.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
1

---------------------- Page: 1 ----------------------
C1897 − 20
pozzolans may contain bound water and lose mass over this on the user’s determination of available equipment. Method A
temperature range. This mass loss needs to be determined and can also provide an indication of rate of reactivity because
used to correct the bound water value for the paste. measurements are taken continuously during the test period,
while M
...

Questions, Comments and Discussion