Standard Test Method for 1,1,1-Trichloroethane Content (Withdrawn 2003)

SCOPE
1.1 This test method provides a basis for the determination of the 1,1,1-trichloroethane (weight%) in the presence of stabilizers and impurities, in virgin or reclaimed 1,1,1-trichloroethane products.

General Information

Status
Withdrawn
Publication Date
09-May-1998
Withdrawal Date
09-Jun-2003
Current Stage
Ref Project

Buy Standard

Standard
ASTM D3742-98 - Standard Test Method for 1,1,1-Trichloroethane Content (Withdrawn 2003)
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn. Contact
ASTM International (www.astm.org) for the latest information.
Designation: D 3742 – 98
AMERICAN SOCIETY FOR TESTING AND MATERIALS
100 Barr Harbor Dr., West Conshohocken, PA 19428
Reprinted from the Annual Book of ASTM Standards. Copyright ASTM
Standard Test Method for
1
1,1,1-Trichloroethane Content
This standard is issued under the fixed designation D 3742; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1
e NOTE—Section 10, Keywords, was added in June 1994.
1. Scope 5.3.1 Column—Annealed copper or stainless steel tubing,
1
20 ft by ⁄8 in. (2.4 m by 3.2 mm) in outside diameter.
1.1 This test method provides a basis for the determination
3
5.3.2 Packing—Chromosorb W HP, 80/100 mesh coated
of the 1,1,1-trichloroethane (weight %) in the presence of
4
with 20 weight % OV101 (or equivalent, polydimethyl
stabilizers and impurities, in virgin or reclaimed 1,1,1-
siloxane) as the liquid phase.
trichloroethane products.
5.3.3 Or other columns or packings capable of providing
2. Referenced Documents
separation of 1,1,1-trichloroethane from stabilizers and process
impurities.
2.1 ASTM Standards:
2
5.4 Carrier Gas—Dry helium of 99.95 mol % purity.
E 260 Practice for Packed Column Gas Chromatography
5.5 Standard—Uninhibited 1,1,1-trichloroethane of known
3. Summary of Test Method
high purity of at least 98.0 %.
5.6 Flow Meter—Capable of measuring in the prescribed
3.1 Gas chromatographic scans of 1,1,1-trichloroethane of
gas flow ranges.
known purity and the sample under test are prepared. The
1,1,1-trichloroethane concentration of the unknown is calcu-
6. Suggested Analysis Conditions
lated by comparison of the respective elution peak areas.
6.1 The following analysis conditions are recommended:
4. Significance and Use
Initial Column temperature 85°C
Initial hold time 4 min
4.1 This test method provides an analysis in weight percent
Rate 8°C/min
of the 1,1,1-trichloroethane concentration of virgin, or re-
Final temperature 160°C
Final hold time 16 min
claimed 1,1,1-trichloroethane. Compounds that co-elute with
Detector temperature 250°C
1,1,1-trichloroethane may interfere with this test.
Injector temperature 250°C
3
Carrier gas and flow 20 He/20 cm /min
5. Apparatus
Sample size 2 μL
5.1 Gas Chromatograph having the following minimum
NOTE 1—With a hydrogen flame detector, sample size should be
capabilities:
reduced to around 0.2 μL to prevent overloading the detector.
5.1.1 Temperature programmable column over with control
6.1.1 Employing the conditions recommended, all constitu-
systems capable of maintaining the chromatographic column at
ents of 1,1,1-trichloroethane solvents should elute from the
the prescribed temp
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.