M/586 - Refrigerating Appliances
COMMISSION IMPLEMENTING DECISION of 29.8.2022 on a standardisation request as regards energy labelling of refrigerating appliances to support the application of Delegated Regulation (EU) 2019/2016 and as regards ecodesign of refrigerating appliances to support the application of Regulation (EU) 2019/2019
General Information
Frequently Asked Questions
A European Standardization Mandate is a formal request from the European Commission to the European Standardization Organizations (CEN, CENELEC, and ETSI) to develop European standards (ENs) in support of EU legislation and policies. Mandates are issued under Regulation (EU) No 1025/2012 and help ensure that products and services meet the essential requirements set out in EU directives and regulations.
M/586 is a European Standardization Mandate titled "COMMISSION IMPLEMENTING DECISION of 29.8.2022 on a standardisation request as regards energy labelling of refrigerating appliances to support the application of Delegated Regulation (EU) 2019/2016 and as regards ecodesign of refrigerating appliances to support the application of Regulation (EU) 2019/2019". COMMISSION IMPLEMENTING DECISION of 29.8.2022 on a standardisation request as regards energy labelling of refrigerating appliances to support the application of Delegated Regulation (EU) 2019/2016 and as regards ecodesign of refrigerating appliances to support the application of Regulation (EU) 2019/2019 There are 12 standards developed under this mandate.
Standards developed in response to a mandate and cited in the Official Journal of the European Union become "harmonized standards". Products manufactured in compliance with harmonized standards benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation, facilitating CE marking and market access across the European Economic Area.
This part of EN 62552 specifies the essential characteristics of household and similar
refrigerating appliances cooled by internal natural convection or forced air circulation, and
establishes test methods for checking these characteristics.
This part of EN 62552 describes the methods for the determination of energy consumption
characteristics and defines how these can be assembled to estimate energy consumption
under different usage and climate conditions. This part of EN 62552 also defines the
determination of volume.
- Amendment14 pagesEnglish languagee-Library read for1 day
This part of EN 62552 specifies the essential characteristics of household and similar
refrigerating appliances cooled by internal natural convection or forced air circulation, and
establishes test methods for checking these characteristics.
This part of EN 62552 describes the methods for the determination of performance
requirements. Although there is some commonality in the set-ups for different tests (and so it
may be an advantage to apply them all to one sample), these are separate tests to evaluate
specific characteristics of the sample being tested. This part of IEC 62552 does not specify a
procedure to generalise the results from sample test results to a prediction of the
characteristics of the whole population from which that sample was selected.
- Amendment14 pagesEnglish languagee-Library read for1 day
This part of EN 62552 specifies the essential characteristics of household and similar
refrigerating appliances cooled by internal natural convection or forced air circulation, and
establishes test methods for checking these characteristics.
For the purposes of declaration, the tests defined in this part of IEC 62552 are considered to
be type tests to assess the fundamental design and operation of a refrigerating appliance.
This part of IEC 62552 does not define requirements for production sampling or conformity
assessment or certification.
This part of IEC 62552 does not define a regime for verification testing as this varies by
region and country. When verification of the performance of a refrigerating appliance of a
given type in relation to this standard is necessary, it is preferable, wherever practicable, that
all the tests specified be applied to a single unit. The tests can also be made individually for
the study of a particular characteristic.
- Amendment12 pagesEnglish languagee-Library read for1 day
This part of EN 62552 specifies the essential characteristics of household and similar refrigerating appliances cooled by internal natural convection or forced air circulation, and establishes test methods for checking these characteristics. For the purposes of declaration, the tests defined in this part of IEC 62552 are considered to be type tests to assess the fundamental design and operation of a refrigerating appliance. This part of IEC 62552 does not define requirements for production sampling or conformity assessment or certification. This part of IEC 62552 does not define a regime for verification testing as this varies by region and country. When verification of the performance of a refrigerating appliance of a given type in relation to this standard is necessary, it is preferable, wherever practicable, that all the tests specified be applied to a single unit. The tests can also be made individually for the study of a particular characteristic.
- Amendment12 pagesEnglish languagee-Library read for1 day
This part of EN 62552 specifies the essential characteristics of household and similar refrigerating appliances cooled by internal natural convection or forced air circulation, and establishes test methods for checking these characteristics. This part of EN 62552 describes the methods for the determination of energy consumption characteristics and defines how these can be assembled to estimate energy consumption under different usage and climate conditions. This part of EN 62552 also defines the determination of volume.
- Amendment14 pagesEnglish languagee-Library read for1 day
This part of EN 62552 specifies the essential characteristics of household and similar refrigerating appliances cooled by internal natural convection or forced air circulation, and establishes test methods for checking these characteristics. This part of EN 62552 describes the methods for the determination of performance requirements. Although there is some commonality in the set-ups for different tests (and so it may be an advantage to apply them all to one sample), these are separate tests to evaluate specific characteristics of the sample being tested. This part of IEC 62552 does not specify a procedure to generalise the results from sample test results to a prediction of the characteristics of the whole population from which that sample was selected.
- Amendment14 pagesEnglish languagee-Library read for1 day
IEC 62552-2:2015 specifies the essential characteristics of household refrigerating appliances cooled by internal natural convection or forced air circulation, and specifies test methods for checking the characteristics.
This part of IEC 62552 describes the methods for the determination of performance requirements. Although there is some commonality in the set-ups for different tests (and so it may be an advantage to apply them all to one sample), these are separate tests to evaluate specific characteristics of the sample being tested. This part of IEC 62552 does not specify a procedure to generalise the results from sample test results to a prediction of the characteristics of the whole population from which that sample was selected.
IEC 62552-1, IEC 62552-2 and IEC 62552-3 cancel and replace the first edition of IEC 62552 published in 2007. IEC 62552-1, IEC 62552-2 and IEC 62552-3 together constitute a technical revision and include the following significant technical changes with respect to IEC 62552:2007:
- A cooling capacity test has been added in Part 2 (this part).
- A pull-down test has been added in Part 2 (this part).
- Performance tests have been added for wine storage appliances in Part 2 (this part).
- Standard61 pagesEnglish languagee-Library read for1 day
IEC 62552-3:2015 specifies the essential characteristics of household and similar refrigerating appliances cooled by internal natural convection or forced air circulation, and establishes test methods for checking these characteristics.
This part of IEC 62552 describes the methods for the determination of energy consumption characteristics and defines how these can be assembled to estimate energy consumption under different usage and climate conditions. This part of IEC 62552 also defines the determination of volume.
- All parts of the standard have been largely rewritten and updated to cope with new testing requirements, new product configurations, the advent of electronic product controls and computer based test-room data collection and processing equipment.
- For more efficient analysis and to better characterise the key product characteristics under different operating conditions, the test data from many of the energy tests in Part 3 (this part) is now split into components (such as steady state operation and defrost and recovery). The approach to determination of energy consumption has been completely revised, with many internal checks now included to ensure that data complying with the requirements of the standard is as accurate as possible and of high quality.
- Part 3 (this part) now provides a method to quantify each of the relevant energy components and approaches on how these can be combined to estimate energy under different conditions on the expectation that different regions will select components and weightings that are most applicable when setting both their local performance and energy efficiency criteria while using a single set of global test measurements.
- For energy consumption measurements in Part 3 (this part), no thermal mass (test packages) is included in any compartment and compartment temperatures are based on the average of air temperature sensors (compared to the temperature in the warmest test package). There are also significant differences in the position of temperature sensors in unfrozen compartments.
- The energy consumption test in Part 3 (this part) now has two specified ambient temperatures (16°C and 32°C).
- A load processing energy efficiency test has been added in Part 3 (this part).
- Tests (both performance (Part 2) and energy (Part 3 (this part)) have been added for wine storage appliances.
- Standard175 pagesEnglish languagee-Library read for1 day
IEC 62552-1:2015 specifies the essential characteristics of household refrigerating appliances, cooled by internal natural convection or forced air circulation, and establishes test methods for checking the characteristics. For the purposes of declaration, the tests defined in this part of IEC 62552 are considered to be type tests to assess the fundamental design and operation of a refrigerating appliance. This part of IEC 62552 does not define requirements for production sampling or conformity assessment or certification. This part of IEC 62552 does not define a regime for verification testing as this varies by region and country. When verification of the performance of a refrigerating appliance of a given type in relation to this standard is necessary, it is preferable, wherever practicable, that all the tests specified be applied to a single unit. The tests can also be made individually for the study of a particular characteristic. IEC 62552-1, -2 and -3 cancel and replace the first edition of IEC 62552 published in 2007. IEC 62552-1, -2 and -3 constitute a technical revision and includes the following significant technical changes with respect to IEC 62552:2007:
a) All parts of the standard have been largely rewritten and updated to cope with new testing requirements, new product configurations, the advent of electronic product controls and computer based test-room data collection and processing equipment.
b) In Part 1 (this part) there are some changes to test room equipment specifications and the setup for testing to provide additional flexibility especially when testing multiple appliances in a single test room.
- Standard114 pagesEnglish languagee-Library read for1 day
IEC 62552-1:2015 specifies the essential characteristics of household refrigerating appliances, cooled by internal natural convection or forced air circulation, and establishes test methods for checking the characteristics. For the purposes of declaration, the tests defined in this part of IEC 62552 are considered to be type tests to assess the fundamental design and operation of a refrigerating appliance. This part of IEC 62552 does not define requirements for production sampling or conformity assessment or certification. This part of IEC 62552 does not define a regime for verification testing as this varies by region and country. When verification of the performance of a refrigerating appliance of a given type in relation to this standard is necessary, it is preferable, wherever practicable, that all the tests specified be applied to a single unit. The tests can also be made individually for the study of a particular characteristic. IEC 62552-1, -2 and -3 cancel and replace the first edition of IEC 62552 published in 2007. IEC 62552-1, -2 and -3 constitute a technical revision and includes the following significant technical changes with respect to IEC 62552:2007: a) All parts of the standard have been largely rewritten and updated to cope with new testing requirements, new product configurations, the advent of electronic product controls and computer based test-room data collection and processing equipment. b) In Part 1 (this part) there are some changes to test room equipment specifications and the setup for testing to provide additional flexibility especially when testing multiple appliances in a single test room.
- Standard114 pagesEnglish languagee-Library read for1 day
IEC 62552-2:2015 specifies the essential characteristics of household refrigerating appliances cooled by internal natural convection or forced air circulation, and specifies test methods for checking the characteristics. This part of IEC 62552 describes the methods for the determination of performance requirements. Although there is some commonality in the set-ups for different tests (and so it may be an advantage to apply them all to one sample), these are separate tests to evaluate specific characteristics of the sample being tested. This part of IEC 62552 does not specify a procedure to generalise the results from sample test results to a prediction of the characteristics of the whole population from which that sample was selected. IEC 62552-1, IEC 62552-2 and IEC 62552-3 cancel and replace the first edition of IEC 62552 published in 2007. IEC 62552-1, IEC 62552-2 and IEC 62552-3 together constitute a technical revision and include the following significant technical changes with respect to IEC 62552:2007: - A cooling capacity test has been added in Part 2 (this part). - A pull-down test has been added in Part 2 (this part). - Performance tests have been added for wine storage appliances in Part 2 (this part).
- Standard61 pagesEnglish languagee-Library read for1 day
IEC 62552-3:2015 specifies the essential characteristics of household and similar refrigerating appliances cooled by internal natural convection or forced air circulation, and establishes test methods for checking these characteristics. This part of IEC 62552 describes the methods for the determination of energy consumption characteristics and defines how these can be assembled to estimate energy consumption under different usage and climate conditions. This part of IEC 62552 also defines the determination of volume. - All parts of the standard have been largely rewritten and updated to cope with new testing requirements, new product configurations, the advent of electronic product controls and computer based test-room data collection and processing equipment. - For more efficient analysis and to better characterise the key product characteristics under different operating conditions, the test data from many of the energy tests in Part 3 (this part) is now split into components (such as steady state operation and defrost and recovery). The approach to determination of energy consumption has been completely revised, with many internal checks now included to ensure that data complying with the requirements of the standard is as accurate as possible and of high quality. - Part 3 (this part) now provides a method to quantify each of the relevant energy components and approaches on how these can be combined to estimate energy under different conditions on the expectation that different regions will select components and weightings that are most applicable when setting both their local performance and energy efficiency criteria while using a single set of global test measurements. - For energy consumption measurements in Part 3 (this part), no thermal mass (test packages) is included in any compartment and compartment temperatures are based on the average of air temperature sensors (compared to the temperature in the warmest test package). There are also significant differences in the position of temperature sensors in unfrozen compartments. - The energy consumption test in Part 3 (this part) now has two specified ambient temperatures (16°C and 32°C). - A load processing energy efficiency test has been added in Part 3 (this part). - Tests (both performance (Part 2) and energy (Part 3 (this part)) have been added for wine storage appliances.
- Standard175 pagesEnglish languagee-Library read for1 day