11.140 - Hospital equipment
Hospital equipment
Krankenhausausstattung
Équipements des hôpitaux
Oprema bolnišnic
General Information
IEC 60601-2-35:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this document.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies bot...view more
- Standard70 pagesEnglish language
sale 15% off
This document specifies requirements for packaged sterile, or bulked non-sterile, rubber gloves intended for use in medical examinations and diagnostic or therapeutic procedures to protect the patient and the user from cross-contamination. It also covers rubber gloves intended for use in handling contaminated medical materials and gloves with smooth surfaces or with textured surfaces over all or part of the glove. This document is intended as a reference for the performance and safety of rubber ...view more
- Standard10 pagesEnglish language
sale 15% off- Draft9 pagesEnglish language
sale 15% off
This document specifies requirements and provides the test method for medical gloves for single use in order to determine freedom from holes.
- Standard8 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft8 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60601-2-46:2010 specifies safety requirements for operating tables, whether or not having electrical parts, including transporters, used for the transportation of the table top to or from the base or pedestal of an operating table with detachable table top. This second edition cancels and replaces the first edition published in 1998 and constitutes a technical revision. This edition of IEC 60601-2-46 was revised to align structurally with the 2005 edition of IEC 60601-1.
- Standard27 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC 60601-2-46:2010 specifies safety requirements for operating tables, whether or not having electrical parts, including transporters, used for the transportation of the table top to or from the base or pedestal of an operating table with detachable table top. This second edition cancels and replaces the first edition published in 1998 and constitutes a technical revision. This edition of IEC 60601-2-46 was revised to align structurally with the 2005 edition of IEC 60601-1.
- Standard27 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies construction, design, performance requirements and test methods for medical face masks intended to limit the transmission of infective agents from staff to patients during surgical procedures and other medical settings with similar requirements. A medical face mask with an appropriate microbial barrier can also be effective in reducing the emission of infective agents from the nose and mouth of an asymptomatic carrier or a patient with clinical symptoms.
This European St...view more
- Standard23 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies construction, design, performance requirements and test methods for medical face masks intended to limit the transmission of infective agents from staff to patients during surgical procedures and other medical settings with similar requirements. A medical face mask with an appropriate microbial barrier can also be effective in reducing the emission of infective agents from the nose and mouth of an asymptomatic carrier or a patient with clinical symptoms.
This European St...view more
- Standard23 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies information to be supplied to users and third party verifiers in addition to the usual labelling of medical devices (see EN 1041 and EN ISO 15223-1), concerning manufacturing and processing requirements. This European Standard gives information on the characteristics of single-use and reusable surgical gowns and surgical drapes used as medical devices for patients, clinical staff and equipment, intended to prevent the transmission of infective agents between clin...view more
- Standard33 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies information to be supplied to users and third party verifiers in addition to the usual labelling of medical devices (see EN 1041 and EN ISO 15223-1), concerning manufacturing and processing requirements. This European Standard gives information on the characteristics of single-use and reusable clean air suits used as medical devices for clinical staff, intended to prevent the transmission of infective agents between clinical staff and patients during surgical and...view more
- Standard29 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies information to be supplied to users and third party verifiers in addition to the usual labelling of medical devices (see EN 1041 and EN ISO 15223-1), concerning manufacturing and processing requirements. This European Standard gives information on the characteristics of single-use and reusable surgical gowns and surgical drapes used as medical devices for patients, clinical staff and equipment, intended to prevent the transmission of infective agents between clin...view more
- Standard33 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies information to be supplied to users and third party verifiers in addition to the usual labelling of medical devices (see EN 1041 and EN ISO 15223-1), concerning manufacturing and processing requirements. This European Standard gives information on the characteristics of single-use and reusable clean air suits used as medical devices for clinical staff, intended to prevent the transmission of infective agents between clinical staff and patients during surgical and...view more
- Standard29 pagesEnglish language
sale 10% off- e-Library read for1 day
This Technical Specification sets out the structure for a standard related to ventilation in hospitals. It gives the requirements for the drafting of the parts of the standard, including common terms and definitions.
The standard for ventilation in hospitals is intended for all healthcare premises where healthcare services are delivered. It is applicable for healthcare services located in a hospital, clinic or other premises. It includes general and specific risk areas, and provides defined lev...view more
- Technical specification28 pagesEnglish language
sale 10% off- e-Library read for1 day
This Technical Report provides information for those choosing or using sterile and non-sterile gloves for medical applications based on a risk assessment. It deals with gloves worn primarily for the protection of the patient and glove user from biological cross contamination.
NOTE Gloves worn specifically for the protection of the glove user from e.g. chemical and biological hazards are covered by the EU-Directive on Personal Protective Equipment (PPE) and the related standards e.g. EN 16523 1,...view more
- Technical report23 pagesEnglish language
sale 10% off- e-Library read for1 day
This Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL BEDS, hereafter referred to as MEDICAL BEDS as defined in 201.3.218, intended for CHILDREN as defined in 201.3.207, and ADULTS with atypical anatomy (ADULTS ranging outside the definition for ADULTS in 201.3.201).
This standard applies to medical beds with nonadjustable and electrical / mechanical adjustable functions.
This Standard applies to MEDICAL BEDS with an internal length of up to 180 cm suitable to a body l...view more
- Standard89 pagesEnglish language
sale 10% off- e-Library read for1 day
201.1 Scope, object and related standards Clause 1 of EN 60601-1:2006, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance, applies, except as follows: 201.1.1 * Scope Replacement: This Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL BEDS, hereafter referred to as MEDICAL BEDS as defined in 201.3.218, intended for CHILDREN as defined in 201.3.207, and ADULTS with atypical anatomy (ADULTS ranging outside the definition f...view more
- Standard89 pagesEnglish language
sale 10% off- e-Library read for1 day
This Technical Report provides information for those choosing or using sterile and non-sterile gloves for medical applications based on a risk assessment. It deals with gloves worn primarily for the protection of the patient and glove user from biological cross contamination.
NOTE Gloves worn specifically for the protection of the glove user from e.g. chemical and biological hazards are covered by the EU-Directive on Personal Protective Equipment (PPE) and the related standards e.g. EN 16523-1,...view more
- Technical report23 pagesEnglish language
sale 10% off- e-Library read for1 day
IEC TR 60601-4-1:2017(E) is intended to help a manufacturer through the key decisions and steps to be taken to perform a detailed risk management and usability engineering processes for medical electrical equipment or a medical electrical system, hereafter referred to as MEE or MES, employing a degree of autonomy (DOA). This document provides a definition of DOA of MEE or MES and a medical robot, and also provides guidance on: - methodologies to perform the risk management process and usability ...view more
- Technical report80 pagesEnglish language
sale 15% off
IEC TR 62343-6-10:2017(E) which is a Technical Report, discusses the rationale, conceptual definition, and minimum list of functions for an intermediate controller that delivers a dynamic control signal to multiple dynamic modules. These modules are included in an optical-switch-based network node, according to the upper layer controller of software-defined optical networking.
- Technical report15 pagesEnglish language
sale 15% off
- Amendment9 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment9 pagesEnglish language
sale 10% off- e-Library read for1 day