11.080.20 - Disinfectants and antiseptics
Disinfectants and antiseptics
Desinfektionsmittel
Desinfectants antiseptiques
Dezinfektanti in antiseptiki
General Information
- 1 (current)
- 2
- 3
- 4
- 5
The method described herein is designed to determine the disinfectant activity of processes used in hospital, medical, pharmaceutical and cosmetics, veterinary, industrial and food processing areas.
The product trialled is designed to be diffused as gaseous molecules or solid or liquid-form dispersants.
NOTE Concerning automatic disinfectant processes:
the limits to use, especially in terms of ability to diffuse throughout the room (min and max effective volumes), shall be specified and stated...view more
- Standard64 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft64 pagesEnglish language
sale 10% off- e-Library read for1 day
The test methods described are designed to determine the disinfectant activity of processes used in the 1) medical area, 2) veterinary area, 3) food, industrial, domestic and institutional area using automated processes for distributing chemicals by air diffusion with no operator manually applying the disinfectant. This document covers the disinfection of nonporous surfaces but not that of the air.
The objective of the described processes is to disinfect the surfaces of the overall area includi...view more
- Standard64 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft64 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water, or - in the case of ready-to-use-products - with water.
This European Standard applies to products that are used in the veterinary area on non-porous surfaces without mechanical action i.e. in the breeding, husbandry, production, veterinary care facilities, transport...view more
- Standard34 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft31 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water, or - in the case of ready-to-use-products - with water.
This European Standard applies to products that are used in the veterinary area on non-porous surfaces without mechanical action i.e. in the breeding, husbandry, production, veterinary care facilities, transport...view more
- Standard34 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft31 pagesEnglish language
sale 10% off- e-Library read for1 day
20191119 - Negative assessment addressed through BT decision C168/2019 (SV)
2019-03-07-JO- under HAS assessment at PUB stage. E&Y Report was due on 03 March 2019. Awaiting for assessement report from E&Y.
2018-10-17 - TAN : Lack of compliance
- Amendment22 pagesEnglish language
sale 10% off- e-Library read for1 day
- Amendment7 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for bactericidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less, as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to products that are...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
- Draft41 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method (phase 2/step 2) and the minimum requirements for bactericidal and/or fungicidal or yeasticidal activity of chemical disinfectants that form a homogeneous physically stable preparation in hard water or – in the case of ready-to-use products – with water in food, industrial, domestic and institutional areas, excluding areas and situations where disinfection is medically indicated and excluding products used on living tissues.
The scope of this Europ...view more
- Standard39 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products, i. e, products that are not diluted when applied, with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organis...view more
- Standard43 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method (phase 2/step 2) and the minimum requirements for bactericidal and/or fungicidal or yeasticidal activity of chemical disinfectants that form a homogeneous physically stable preparation in hard water or – in the case of ready-to-use products – with water in food, industrial, domestic and institutional areas, excluding areas and situations where disinfection is medically indicated and excluding products used on living tissues.
The scope of this Europ...view more
- Standard39 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant and antiseptic products that form a homogeneous physically stable preparation when diluted with hard water or in the case of ready-to-use products, i. e, products that are not diluted when applied, with water. Products can only be tested at a concentration of 80 % (97 %, with a modified method for special cases) as some dilution is always produced by adding the test organis...view more
- Standard43 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of chemical disinfectants that form a homogeneous physically stable preparation when diluted with hard water- or in the case of ready-to-use products - with water.
This European Standard applies to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices without mechanical action.
This European Standard applies to areas and situations w...view more
- Standard37 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for sporicidal activity of chemical disinfectant and antiseptic products that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This E...view more
- Standard59 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectants that form a homogeneous physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document applies to products that are used in the medical area for disinfecting non-porous surfaces including surfaces of medical devices without mechanical action.
This document applies to areas and situations where disinfection is medic...view more
- Standard37 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the European Standards to which products have to conform in order to support the claims for microbicidal activity which are referred to in this European Standard.
This European Standard also specifies terms and definitions which are used in European Standards.
It is applicable to products for which activity is claimed against the following microorganisms: vegetative bacteria (including mycobacteria and Legionella), bacterial spores, yeasts, fungal spores and vi...view more
- Standard69 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies a test method and the minimum requirements for virucidal activity of
chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This European Standard applies to products that are used in the medical area for disinfecting instruments by immersion - even if they are not covered by the EEC/93/42 Directive on Medical Devices.
This European Standard applies...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a test method and the minimum requirements for sporicidal activity of chemical disinfectant that form a homogeneous, physically stable preparation when diluted with hard water, or - in the case of ready-to-use products - with water. Products can only be tested at a concentration of 80 % or less (97 % with a modified method for special cases) as some dilution is always produced by adding the test organisms and interfering substance.
This European Standard applies to produ...view more
- Standard59 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies the European Standards to which products have to conform in order to support the claims for microbicidal activity which are referred to in this European Standard.
This European Standard also specifies terms and definitions which are used in European Standards.
It is applicable to products for which activity is claimed against the following microorganisms: vegetative bacteria (including mycobacteria and Legionella), bacterial spores, yeasts, fungal spores and vi...view more
- Standard69 pagesEnglish language
sale 10% off- e-Library read for1 day
This document defines how to exclude or confirm that an excipient in a biocidal product is an active substance within the frame of the European Biocidal Product Regulation and other regulations.
- Technical report5 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a test method and the minimum requirements for virucidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation when diluted with hard water - or in the case of ready-to-use products - with water.
This document applies to products that are used in the medical area for disinfecting instruments by immersion.
This document applies to areas and situations where disinfection is medically indicated. Such indications occur in patient ...view more
- Standard40 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies a test method (phase 2/step 1) and the minimum requirements for sporicidal activity of chemical disinfectant products that form a homogeneous, physically stable preparation in hard water and that are used in food, industrial, domestic and institutional areas, excluding areas and situations where disinfection is medically indicated and excluding products used on living tissues except those for hand hygiene in the above considered areas.
This European Standard applies at l...view more
- Standard41 pagesEnglish language
sale 10% off- e-Library read for1 day