ISO/TC 210/WG 2 - General aspects stemming from the application of quality principles to medical devices
Aspects généraux issus de l'application de principes de qualité aux dispositifs médicaux
General Information
NOTE 1 There is guidance or rationale for this Clause contained in Clause A.2. This document specifies the requirements for information supplied by the manufacturer for a medical device or by the manufacturer for an accessory, as defined in 3.1. This document includes the generally applicable requirements for identification and labels on a medical device or accessory, the packaging, marking of a medical device or accessory, and accompanying information. This document does not specify the means by which the information is to be supplied. NOTE 2 Some authorities having jurisdiction impose different requirements for the identification, marking and documentation of a medical device or accessory. Specific requirements of medical device product standards or group standards take precedence over requirements of this document.
- Standard72 pagesEnglish languagesale 15% off
- Standard72 pagesEnglish languagesale 15% off
- Standard74 pagesFrench languagesale 15% off
- Standard74 pagesFrench languagesale 15% off
- Draft72 pagesEnglish languagesale 15% off
ISO 16142:2016, which includes the essential principles of safety and performance, identifies significant standards and guides that can be used in the assessment of conformity of a medical device to the recognized essential principles that when met, indicate a medical device is safe and performs as intended. This part of ISO 16142 identifies and describes the six general essential principles of safety and performance that apply to all medical devices, including IVD medical devices (in vitro diagnostic). ISO 16142:2016also identifies and describes the additional essential principles of safety and performance which need to be considered during the design and manufacturing process, which are relevant to medical devices other than IVD medical devices. Future ISO 16142‑2 is intended to identify and describe the essential principles of safety and performance, which need to be considered during the design and manufacturing process of IVD medical devices. NOTE During the design process, the manufacturer selects which of the listed design and manufacturing principles apply to the particular medical device and documents the reasons for excluding others. ISO 16142:2016 is intended for use as guidance by medical device manufacturers, standards development organizations, authorities having jurisdiction, and conformity assessment bodies.
- Standard47 pagesEnglish languagesale 15% off