MT 60079-10-2 - TC 31/SC 31J/MT 60079-10-2
TC 31/SC 31J/MT 60079-10-2
General Information
IEC 60079-10-2:2015 is available as IEC 60079-10-2:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-10-2:2015 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition. Keywords: explosive dust atmospheres, combustible dust layers, ignition hazards
- Standard56 pagesEnglish and French languagesale 15% off
IEC 60079-10-2:2009 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. The principles of this standard can also be followed when combustible fibres or flyings may cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. This first edition of IEC 60079-10-2 cancels and replaces the first edition of IEC 61241-10 published in 2004. The significant technical changes with respect to IEC 61241-10 are:
- the hazards presented by dust have been clarified;
- dust groups have been introduced;
- Annex D explaining Equipment Protection Levels (EPLs) has been introduced;
- 1 m of usual extent of zone 22 beyond zone 21 has been expanded to 3 m.