MT 62040-3 - TC 22/SC 22H/MT 62040-3
TC 22/SC 22H/MT 62040-3
General Information
Frequently Asked Questions
MT 62040-3 is a Technical Committee within the International Electrotechnical Commission (IEC). It is named "TC 22/SC 22H/MT 62040-3". This committee has published 1 standards.
MT 62040-3 develops IEC standards in the area of Information technology. Currently, there are 1 published standards from this technical committee.
The International Electrotechnical Commission (IEC) is the world's leading organization for the preparation and publication of international standards for electrical, electronic, and related technologies. Founded in 1906, the IEC provides a global platform for companies, industries, and governments to meet, discuss, and develop the international standards they require.
A Technical Committee (TC) in IEC is a group of experts responsible for developing international standards in a specific technical area. TCs are composed of national member body delegates and work through consensus to create standards that meet global industry needs. Each TC may have subcommittees (SCs) and working groups (WGs) for specialized topics.
IEC 62040-3:2021 establishes the performance and test requirements applied to movable, stationary and fixed electronic uninterruptible power systems (UPS) that
- are supplied from AC voltage not exceeding 1 000 V,
- deliver AC output voltage not exceeding 1 000 V,
- incorporate an energy storage device not exceeding 1 500 V DC, and
- have a primary function to ensure continuity of load power.
This document specifies performance and test requirements of a complete UPS and, where applicable, of individual UPS functional units. This document also includes UPS performance and test requirements related to UPS switches that interact with UPS functional units to maintain continuity of load power.
This document does not cover
- conventional AC and DC distribution boards and their associated switches,
- stand-alone static transfer systems covered by IEC 62310-3,
- rotary UPS covered by IEC 88528-11, and
- DC UPS covered by IEC 62040-5-3.
This edition includes the following significant technical changes with respect to the previous edition:
1) environmental conditions aligned with IEC 62040-1:2017 (UPS safety requirements);
2) compliance requirements included in all sub-clauses referenced in Table 5 UPS test schedule;
3) non-linear step load is no longer a type test and was removed from 6.4 in consistency with requirements for switch mode power supplies incorporating inrush current controls; this resulted in the performance classification coding being shortened from 8 to 7 characters (see 5.3.4);
4) free-fall test aligned with ISO 4180 (see 6.5.1.3);
5) multiple normal mode UPS test requirements introduced;
6) non-linear load requirements relaxed in Annex E in consistency with requirements for switch mode power supplies complying with the applicable limits for harmonic current in IEC 61000-3-2 and IEC 61000-3-12;
7) minimum UPS efficiency values referenced in Annex I became normative and are based on active output power rating and utilisation of weighting factors rather than on allowances related to isolation transformers, input harmonic current filters and input voltages.
- Standard94 pagesEnglish languagesale 15% off
- Standard193 pagesEnglish and French languagesale 15% off