CLC/TC 14/WG 21 - Revision of HD 428 and HD 538
Revision of HD 428 and HD 538
General Information
Frequently Asked Questions
CLC/TC 14/WG 21 is a Working Group within CLC. It is named "Revision of HD 428 and HD 538". This committee has published 8 standards.
CLC/TC 14/WG 21 develops CLC standards in the area of W05 - POWER TRANSFORMERS - Information technology. Currently, there are 8 published standards from this working group.
CLC is a standardization organization that develops and publishes standards to support industry, commerce, and regulatory requirements.
A Working Group in CLC is a specialized group responsible for developing standards or technical work within a defined scope. These bodies bring together international experts to create consensus-based standards that support global trade, safety, and interoperability.
This document describes the list of typical accessories used for liquid and dry type Medium Power Transformers (≤ 3 150 kVA).
- Standard10 pagesEnglish languagee-Library read for1 day
This document describes a special test for tanks of liquid-immersed transformers which during service are hermetically sealed and fully filled with liquid and volume change of the liquid due to temperature change compensated by elastic deformation of the cooling element for Large Power Transformers having a rated power greater than 3150 kVA.
- Standard9 pagesEnglish languagee-Library read for1 day
This document describes the special tests for Medium Power Transformers ≤ 3150 kVA compliant with the EN 50708 2 series: - for corrugated tank for liquid immersed transformers, - for the method of measurement of losses for one winding in Highest Voltage (HV) and windings in Lowest Voltage (LV) for liquid immersed and dry type transformers.
- Standard9 pagesEnglish languagee-Library read for1 day
This document defines the energy performance of non-conventional technology Medium Power Transformers in compliance with EN 50708-1-1.
- Standard8 pagesEnglish languagee-Library read for1 day
This document applies to all power transformers in scope of TC 14.
- Standard9 pagesEnglish languagee-Library read for1 day
The scope of this document is to define the energy performance of liquid immersed single-phase Medium Power Transformers in compliance with EN 50708 1 1:2020.
- Standard8 pagesEnglish languagee-Library read for1 day
TC - Correction of technical errors
- Corrigendum1 pageEnglish languagee-Library read for1 day
The scope of this document is to define the energy performance of Medium Power Transformers in compliance with EN 50708-1-1:2020.
- Standard14 pagesEnglish languagee-Library read for1 day