SIST ISO 17559:2005
(Main)Hydraulic fluid power -- Electrically controlled hydraulic pumps -- Test methods to determine performance characteristics
Hydraulic fluid power -- Electrically controlled hydraulic pumps -- Test methods to determine performance characteristics
ISO 17599:2003 specifies methods for determining the steady-state performance characteristics and dynamic performance characteristics of positive-displacement electrically and electronically controlled hydraulic pumps, so as to allow comparison of the performance of different components.
Pumps covered by ISO 17599:2003 have the capacity to affect changes in the output flow or pressure in proportion to the electrical or electronic input signals. These pumps can be of the load-sensing control type, servo-control type, or electrical variable displacement mechanism type, which control output flow and output pressure by feedback using electrical signals.
Transmissions hydrauliques -- Pompes hydrauliques à commande électrique -- Méthodes d'essai pour déterminer les caractéristiques de fonctionnement
L'ISO 17559:2003 spécifie les méthodes d'essai pour déterminer les caractéristiques de fonctionnement en régime permanent et les caractéristiques de fonctionnement dynamique des pompes hydrauliques à commande électrique et électronique à déplacement positif, afin de permettre la comparaison des performances des différents composants.
Les pompes faisant l'objet de l'ISO 17559:2003 sont susceptibles de modifier le débit ou la pression de sortie en proportion des signaux d'entrée électriques ou électroniques. Ces pompes peuvent être à commande de détection de charge, à servocommande ou à cylindrée variable électrique, qui commandent le débit et la pression de sortie par rétroaction grâce à des signaux électriques.
Fluidna tehnika – Hidravlika – Električno krmiljene hidravlične črpalke – Preskusne metode za ugotovitev delovnih karakteristik
General Information
Buy Standard
Standards Content (Sample)
INTERNATIONAL ISO
STANDARD 17559
First edition
2003-11-15
Hydraulic fluid power — Electrically
controlled hydraulic pumps — Test
methods to determine performance
characteristics
Transmissions hydrauliques — Pompes hydrauliques à commande
électrique — Méthodes d'essai pour déterminer les caractéristiques de
fonctionnement
Reference number
ISO 17559:2003(E)
©
ISO 2003
---------------------- Page: 1 ----------------------
ISO 17559:2003(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2003
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
©
ii ISO 2003 – All rights reserved
---------------------- Page: 2 ----------------------
ISO 17559:2003(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols . 2
5 Test installation — General requirements . 2
5.1 General . 2
5.2 General test apparatus . 4
6 General test conditions . 5
6.1 Test fluid . 5
6.2 Ambient conditions . 5
6.3 Steady-state conditions . 5
7 Tests of steady-state performance characteristics . 5
7.1 General . 5
7.2 Flow/pressure characteristics . 5
7.3 Characteristic test on output pressure against input pressure command signal: test procedure
and presentation of test results . 7
7.4 Characteristic test of output flow against input flow signal — Test procedure and expression of
test results . 8
7.5 Repeatability test . 9
7.6 Test for change in characteristics against oil temperature . 12
8 Tests of dynamic performance characteristics . 13
8.1 General . 13
8.2 Pressure compensator response and recovery . 13
8.3 Test of step response versus output pressure — Test procedure and presentation
of test results . 14
8.4 Test of step response versus output flow — Test procedure and presentation of test results . 15
8.5 Frequency response . 16
Annex A (normative) Classes of measurement accuracy . 19
Bibliography . 20
©
ISO 2003 – All rights reserved iii
---------------------- Page: 3 ----------------------
ISO 17559:2003(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 17559 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 8,
Product testing.
©
iv ISO 2003 – All rights reserved
---------------------- Page: 4 ----------------------
ISO 17559:2003(E)
Introduction
This International Standard is intended to unify testing methods of positive-displacement electrically and
electronically controlled hydraulic pumps so as to allow comparison of the performance of different components.
Requirements for test installations, procedures and expression of results are described.
©
ISO 2003 – All rights reserved v
---------------------- Page: 5 ----------------------
.
vi
---------------------- Page: 6 ----------------------
INTERNATIONAL STANDARD ISO 17559:2003(E)
Hydraulic fluid power — Electrically controlled hydraulic
pumps — Test methods to determine performance
characteristics
1Scope
This International Standard specifies methods for determining the steady-state performance characteristics and
dynamic performance characteristics of positive-displacement electrically and electronically controlled hydraulic
pumps (hereafter referred to as “pump” or “pumps”), so as to allow comparison of the performance of different
components.
Pumps covered by this International Standard have the capacity to affect changes in the output flow or pressure
in proportion to the electrical or electronic input signals. These pumps can be of the load-sensing control type,
servo-control type, or electrical variable displacement mechanism type, which control output flow and output
pressure by feedback using electrical signals.
The accuracy of measurement is divided into three classes, A, B and C, which are explained in Annex A.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 3448, Industrial liquid lubricants — ISO viscosity classification
ISO 4391, Hydraulic fluid power — Pumps, motors and integral transmissions — Parameter definitions and
letter symbols
ISO 4406, Hydraulic fluid power — Fluids — Method for coding the level of contamination by solid particles
ISO 4409, Hydraulic fluid power — Positive displacement pumps, motors and integral transmissions —
Determination of steady-state performance
ISO 5598, Fluid power systems and components — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5598 and the following apply.
3.1
electrically controlled hydraulic pump
variable displacement pump which is capable of controlling the pressure or flow rate, or the pressure and flow
rate corresponding to an input signal
3.2
minimum flow command
minimum input flow command signal needed to maintain the maximum working pressure
©
ISO 2003 – All rights reserved 1
---------------------- Page: 7 ----------------------
ISO 17559:2003(E)
3.3
minimum controllable pressure
minimum output pressure when the absolute value of the input pressure command signal is zero and the input
flow command signal is maximum (see 7.2.4)
3.4
dead zone
range wherein the output pressure or output flow being controlled by the input signal does not vary when the
absolute value of the input signal increases from zero or decreases to zero
3.5
load volume
gross volume of working fluid in the main pipelines from the outlet of the pump to be tested to the inlet of the
loading valve
3.6
pressure compensation
condition in which the output flow starts to decrease by the variable displacement control mechanism when the
output pressure approaches a set pressure
3.7
deadhead pressure
output pressure without flow
4 Symbols
4.1 The physical quantity letter symbols and their suffixes used in this International Standard (see Table 1),
are fully explained in ISO 4391.
Units are given in Table 1 and Annex A.
4.2 Graphical symbols used in Figures 1 and 2, showing test circuit diagrams, conform to ISO 1219-1 and
ISO 1219-2.
Table 1 — Symbols and units
a
Quantity Symbol Dimension SI unit
2 –3
Power P M L T W
–1 –2
Pressure, differential pressure p, ∆p M L T MPa
3 –1 3
Flow rate q L T dm /min
–1 –1
Rotational speed n T min
a
M = mass, L = length, T = time.
5 Test installation — General requirements
5.1 General
5.1.1 Unless otherwise specified, install the pump with the output shaft horizontal and the drain port facing
upwards.
5.1.2 Use a hydraulic test circuit conforming to Figure 1 for test pumps having a pressure control valve to
control the pressure in the pressure-compensation state and a flow control valve to control the output flow.
5.1.3 Use a hydraulic test circuit conforming to Figure 2 for test pumps that utilize electrical input signals to
control the pressure in the pressure-compensation state and either the position or angle of the mechanism to
vary the displacement of the pump.
©
2 ISO 2003 – All rights reserved
---------------------- Page: 8 ----------------------
ISO 17559:2003(E)
5.1.4 For applications where the pump will be part of a closed-loop control system it may be necessary to
perform a frequency response test. Subclause 8.5 describes a pump test method. The need for the test should
be agreed between the customer and manufacturer.
Key
1 pump under
test
2 loading valve
3 directional
control valve
4 variable
restrictor
5 torque meter
6 torque
indicator
7 speed meter
8 electrical
pressure
transducer
9 pressure
gauge
10 electrical flow
transducer
11 thermometer
12 control device
13 signal source
14 control device
15 signal source
16 recorder
17 electric motor
18 manual relief
valve
NOTE Details of the pump control valves are for illustration only.
Figure 1 — Pump with pressure-compensation control valve and flow control valve
to control output flow
©
ISO 2003 – All rights reserved 3
---------------------- Page: 9 ----------------------
ISO 17559:2003(E)
Key
1 pump under test
2 loading valve
3 directional control
value
4 variable restrictor
5 torque meter
6 torque indicator
7 speed meter
8 electrical pressure
transducer
9 electrical flow
transducer
10 pressure gauge
11 thermometer
12 control device
13 signal source
14 recorder
15 electric motor
16 manual relief valve
NOTE Details of the pump control valves are for illustration only.
Figure 2 — Pump with electrical input signals to control pressure-compensation and either the position
or angle of the mechanism to vary displacement
5.2 General test apparatus
5.2.1 Set up a test rig conforming to 5.1.1 to 5.1.3 and Figures 1 and 2 as applicable.
5.2.2 Maintain the loading valve and variable restrictor in the test circuit at no loading and no restriction except
for the conditions specified in the test procedure. If the loading valve is operated, open the variable restrictor
completely and adjust the directional control valve so that the P port is closed. If the variable restrictor is
operated, adjust the directional control valve so that the P port opens to the A port.
5.2.3 Set the manual relief valve integrated with the pump for safety purposes to limit the maximum steady-
state pressure to no less than 125 % of the maximum working pressure setting.
©
4 ISO 2003 – All rights reserved
---------------------- Page: 10 ----------------------
ISO 17559:2003(E)
6 General test conditions
6.1 Test fluid
6.1.1 The hydraulic fluid type and viscosity shall conform to ISO VG 32 or ISO VG 46 according to ISO 3448.
◦ ◦
6.1.2 Maintain the fluid temperature at the pump inlet in the range of 45C5 to 5 C.
6.1.3 Maintain the fluid contamination class within 19/16 or less according to ISO 4406.
Conditions other than those indicated in this subclause should be agreed between the supplier and purchaser.
6.2 Ambient conditions
The ambient temperature and any variation from still air conditions shall be recorded.
6.3 Steady-state conditions
Take each set of measurements only when the values of the controlled parameters are within the limits given in
Table 2.
Table 2 — Limits of permissible variation in the values of controlled parameters
Limits of permissible variation in the values of controlled parameters
a
for class of measurement accuracy
Controlled parameter
ABC
◦
Temperature, C ± 0,5 ± 1 ± 2
Rotational speed, % ± 0,5 ± 1 ± 2
Input signal, % ± 0,5 ± 1,5 ± 2,5
a
See Annex A.
7 Tests of steady-state performance characteristics
7.1 General
7.1.1 The test circuit and measuring circuit shall conform to Figures 1 or 2 as applicable.
NOTE In addition to the internal control pressure supply as shown in Figure 2, it is possible to use an external control
pressure supply.
7.1.2 Adjust the electric motor to the specified rotational speed.
7.1.3 The steady-state performance shall be determined in accordance with ISO 4409.
7.1.4 For pumps in accordance with Figure 2, the swivel angle or stroke in percent of the maximum value may
be used as an alternative to the output flow.
7.2 Flow/pressure characteristics
7.2.1 Use the pump having pressure control and flow control functions.
©
ISO 2003 – All rights reserved 5
---------------------- Page: 11 ----------------------
ISO 17559:2003(E)
7.2.2 Determine the minimum flow command by the following procedure:
— set the loading valve to shut-off so that there is no output flow;
— slowly decrease the input flow command signal until the deadhead pressure can no longer be maintained;
— record the value of the input flow command signal as the minimum flow set point.
7.2.3 Tests should be performed at 100 %, 75 % and 50 % of the maximum working pressure. Tests should
90 % 75 % 50 % 25 %
also be performed at , , and of the maximum output flow, and minimum flow command.
7.2.4 Gradually change the output pressure by adjusting the variable restrictor, cycling the pump from the
maximum working pressure, through 75 % and 50 % of the maximum working pressure, to the highest minimum
controllable pressure and output pressure when the variable restrictor is opened completely, and back again.
7.2.5 Plot a graph of output flow against output pressure (see Figure 3).
a
Maximum flow command.
b
Minimum flow command.
c
Minimum controllable pressure.
d
Pressure range from starting pressure-compensation state to deadhead pressure.
e
Hysteresis at pressure-compensation.
f
Maximum width of the change of the output flow.
g
Maximum working pressure.
Figure 3 — Output flow versus pressure
7.2.6 Calculate and record the rate of change of adjustable flow rate δq against output pressure using the
following formula:
∆q
e,1
δq= × 100
q
0
©
6 ISO 2003 – All rights reserved
---------------------- Page: 12 ----------------------
ISO 17559:2003(E)
where
δq is the rate of change in adjustable flow rate, expressed as a percentage;
∆q is the maximum width of the change of output flow (see Figure 3);
e,1
q is the output flow at the minimum controllable pressure for each input flow command signal as
0
explained below.
Calculate the values at 75 % and 50 % of the maximum output flow and minimum flow command settings,
respectively (these values are the rate of change of adjustable flow rate δq against output pressure). For a pump
with pressure-compensation function, ∆q shall be considered the maximum range of flow rate change
e,1
immediately before the pump shifts into pressure-compensation mode.
7.2.7 For a pump with pressure-compensation function, calculate and record the following characteristic
values for each flow rate setting:
— hysteresis ∆p of the pressure when controlled by the pressure compensator;
e,2
— pressure range ∆p from commencement of pressure compensation to deadhead condition.
e,1
7.3 Characteristic test on output pressure against input pressure command signal: test
procedure and presentation of test results
7.3.1 If the pump has pressure control and flow control functions, select input pressure command signal and
input flow command signal, and adjust them to their maximum values.
7.3.2 Completely close the loading valve. Increase and decrease input pressure command signal for one
cycle, from the minimum controllable pressure of the pump to the maximum working pressure, at a rate that
does not subject the pump or measuring equipment to any significant dynamic influence.
7.3.3 Plot a graph of output pressure against input pressure command signal (see Figure 4).
7.3.4 Obtain and record the following characteristic value from the recorded data:
∆p
max
δp = × 100
hy
p
max
where
δp is the hysteresis of the output pressure, expressed as a percentage;
hy
∆p is the maximum difference in pressure at the same input signal;
max
p is the maximum working pressure.
max
7.3.5 Obtain the adjustable range of output pressure from the recorded data.
7.3.6 Obtain the input
...
SLOVENSKI STANDARD
SIST ISO 17559:2005
01-november-2005
)OXLGQDWHKQLND±+LGUDYOLND±(OHNWULþQRNUPLOMHQHKLGUDYOLþQHþUSDONH±3UHVNXVQH
PHWRGH]DXJRWRYLWHYGHORYQLKNDUDNWHULVWLN
Hydraulic fluid power -- Electrically controlled hydraulic pumps -- Test methods to
determine performance characteristics
Transmissions hydrauliques -- Pompes hydrauliques à commande électrique --
Méthodes d'essai pour déterminer les caractéristiques de fonctionnement
Ta slovenski standard je istoveten z: ISO 17559:2003
ICS:
23.100.10 +LGUDYOLþQHþUSDONHLQPRWRUML Pumps and motors
SIST ISO 17559:2005 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---------------------- Page: 1 ----------------------
SIST ISO 17559:2005
---------------------- Page: 2 ----------------------
SIST ISO 17559:2005
INTERNATIONAL ISO
STANDARD 17559
First edition
2003-11-15
Hydraulic fluid power — Electrically
controlled hydraulic pumps — Test
methods to determine performance
characteristics
Transmissions hydrauliques — Pompes hydrauliques à commande
électrique — Méthodes d'essai pour déterminer les caractéristiques de
fonctionnement
Reference number
ISO 17559:2003(E)
©
ISO 2003
---------------------- Page: 3 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
PDF disclaimer
This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall
not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In
downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat
accepts no liability in this area.
Adobe is a trademark of Adobe Systems Incorporated.
Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation
parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the
unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below.
© ISO 2003
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means,
electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or
ISO's member body in the country of the requester.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Published in Switzerland
©
ii ISO 2003 – All rights reserved
---------------------- Page: 4 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
Contents Page
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Symbols . 2
5 Test installation — General requirements . 2
5.1 General . 2
5.2 General test apparatus . 4
6 General test conditions . 5
6.1 Test fluid . 5
6.2 Ambient conditions . 5
6.3 Steady-state conditions . 5
7 Tests of steady-state performance characteristics . 5
7.1 General . 5
7.2 Flow/pressure characteristics . 5
7.3 Characteristic test on output pressure against input pressure command signal: test procedure
and presentation of test results . 7
7.4 Characteristic test of output flow against input flow signal — Test procedure and expression of
test results . 8
7.5 Repeatability test . 9
7.6 Test for change in characteristics against oil temperature . 12
8 Tests of dynamic performance characteristics . 13
8.1 General . 13
8.2 Pressure compensator response and recovery . 13
8.3 Test of step response versus output pressure — Test procedure and presentation
of test results . 14
8.4 Test of step response versus output flow — Test procedure and presentation of test results . 15
8.5 Frequency response . 16
Annex A (normative) Classes of measurement accuracy . 19
Bibliography . 20
©
ISO 2003 – All rights reserved iii
---------------------- Page: 5 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies
(ISO member bodies). The work of preparing International Standards is normally carried out through ISO
technical committees. Each member body interested in a subject for which a technical committee has been
established has the right to be represented on that committee. International organizations, governmental and
non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International
Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.
The main task of technical committees is to prepare International Standards. Draft International Standards
adopted by the technical committees are circulated to the member bodies for voting. Publication as an
International Standard requires approval by at least 75 % of the member bodies casting a vote.
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. ISO shall not be held responsible for identifying any or all such patent rights.
ISO 17559 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 8,
Product testing.
©
iv ISO 2003 – All rights reserved
---------------------- Page: 6 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
Introduction
This International Standard is intended to unify testing methods of positive-displacement electrically and
electronically controlled hydraulic pumps so as to allow comparison of the performance of different components.
Requirements for test installations, procedures and expression of results are described.
©
ISO 2003 – All rights reserved v
---------------------- Page: 7 ----------------------
SIST ISO 17559:2005
.
vi
---------------------- Page: 8 ----------------------
SIST ISO 17559:2005
INTERNATIONAL STANDARD ISO 17559:2003(E)
Hydraulic fluid power — Electrically controlled hydraulic
pumps — Test methods to determine performance
characteristics
1Scope
This International Standard specifies methods for determining the steady-state performance characteristics and
dynamic performance characteristics of positive-displacement electrically and electronically controlled hydraulic
pumps (hereafter referred to as “pump” or “pumps”), so as to allow comparison of the performance of different
components.
Pumps covered by this International Standard have the capacity to affect changes in the output flow or pressure
in proportion to the electrical or electronic input signals. These pumps can be of the load-sensing control type,
servo-control type, or electrical variable displacement mechanism type, which control output flow and output
pressure by feedback using electrical signals.
The accuracy of measurement is divided into three classes, A, B and C, which are explained in Annex A.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated
references, only the edition cited applies. For undated references, the latest edition of the referenced document
(including any amendments) applies.
ISO 3448, Industrial liquid lubricants — ISO viscosity classification
ISO 4391, Hydraulic fluid power — Pumps, motors and integral transmissions — Parameter definitions and
letter symbols
ISO 4406, Hydraulic fluid power — Fluids — Method for coding the level of contamination by solid particles
ISO 4409, Hydraulic fluid power — Positive displacement pumps, motors and integral transmissions —
Determination of steady-state performance
ISO 5598, Fluid power systems and components — Vocabulary
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 5598 and the following apply.
3.1
electrically controlled hydraulic pump
variable displacement pump which is capable of controlling the pressure or flow rate, or the pressure and flow
rate corresponding to an input signal
3.2
minimum flow command
minimum input flow command signal needed to maintain the maximum working pressure
©
ISO 2003 – All rights reserved 1
---------------------- Page: 9 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
3.3
minimum controllable pressure
minimum output pressure when the absolute value of the input pressure command signal is zero and the input
flow command signal is maximum (see 7.2.4)
3.4
dead zone
range wherein the output pressure or output flow being controlled by the input signal does not vary when the
absolute value of the input signal increases from zero or decreases to zero
3.5
load volume
gross volume of working fluid in the main pipelines from the outlet of the pump to be tested to the inlet of the
loading valve
3.6
pressure compensation
condition in which the output flow starts to decrease by the variable displacement control mechanism when the
output pressure approaches a set pressure
3.7
deadhead pressure
output pressure without flow
4 Symbols
4.1 The physical quantity letter symbols and their suffixes used in this International Standard (see Table 1),
are fully explained in ISO 4391.
Units are given in Table 1 and Annex A.
4.2 Graphical symbols used in Figures 1 and 2, showing test circuit diagrams, conform to ISO 1219-1 and
ISO 1219-2.
Table 1 — Symbols and units
a
Quantity Symbol Dimension SI unit
2 –3
Power P M L T W
–1 –2
Pressure, differential pressure p, ∆p M L T MPa
3 –1 3
Flow rate q L T dm /min
–1 –1
Rotational speed n T min
a
M = mass, L = length, T = time.
5 Test installation — General requirements
5.1 General
5.1.1 Unless otherwise specified, install the pump with the output shaft horizontal and the drain port facing
upwards.
5.1.2 Use a hydraulic test circuit conforming to Figure 1 for test pumps having a pressure control valve to
control the pressure in the pressure-compensation state and a flow control valve to control the output flow.
5.1.3 Use a hydraulic test circuit conforming to Figure 2 for test pumps that utilize electrical input signals to
control the pressure in the pressure-compensation state and either the position or angle of the mechanism to
vary the displacement of the pump.
©
2 ISO 2003 – All rights reserved
---------------------- Page: 10 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
5.1.4 For applications where the pump will be part of a closed-loop control system it may be necessary to
perform a frequency response test. Subclause 8.5 describes a pump test method. The need for the test should
be agreed between the customer and manufacturer.
Key
1 pump under
test
2 loading valve
3 directional
control valve
4 variable
restrictor
5 torque meter
6 torque
indicator
7 speed meter
8 electrical
pressure
transducer
9 pressure
gauge
10 electrical flow
transducer
11 thermometer
12 control device
13 signal source
14 control device
15 signal source
16 recorder
17 electric motor
18 manual relief
valve
NOTE Details of the pump control valves are for illustration only.
Figure 1 — Pump with pressure-compensation control valve and flow control valve
to control output flow
©
ISO 2003 – All rights reserved 3
---------------------- Page: 11 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
Key
1 pump under test
2 loading valve
3 directional control
value
4 variable restrictor
5 torque meter
6 torque indicator
7 speed meter
8 electrical pressure
transducer
9 electrical flow
transducer
10 pressure gauge
11 thermometer
12 control device
13 signal source
14 recorder
15 electric motor
16 manual relief valve
NOTE Details of the pump control valves are for illustration only.
Figure 2 — Pump with electrical input signals to control pressure-compensation and either the position
or angle of the mechanism to vary displacement
5.2 General test apparatus
5.2.1 Set up a test rig conforming to 5.1.1 to 5.1.3 and Figures 1 and 2 as applicable.
5.2.2 Maintain the loading valve and variable restrictor in the test circuit at no loading and no restriction except
for the conditions specified in the test procedure. If the loading valve is operated, open the variable restrictor
completely and adjust the directional control valve so that the P port is closed. If the variable restrictor is
operated, adjust the directional control valve so that the P port opens to the A port.
5.2.3 Set the manual relief valve integrated with the pump for safety purposes to limit the maximum steady-
state pressure to no less than 125 % of the maximum working pressure setting.
©
4 ISO 2003 – All rights reserved
---------------------- Page: 12 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
6 General test conditions
6.1 Test fluid
6.1.1 The hydraulic fluid type and viscosity shall conform to ISO VG 32 or ISO VG 46 according to ISO 3448.
◦ ◦
6.1.2 Maintain the fluid temperature at the pump inlet in the range of 45C5 to 5 C.
6.1.3 Maintain the fluid contamination class within 19/16 or less according to ISO 4406.
Conditions other than those indicated in this subclause should be agreed between the supplier and purchaser.
6.2 Ambient conditions
The ambient temperature and any variation from still air conditions shall be recorded.
6.3 Steady-state conditions
Take each set of measurements only when the values of the controlled parameters are within the limits given in
Table 2.
Table 2 — Limits of permissible variation in the values of controlled parameters
Limits of permissible variation in the values of controlled parameters
a
for class of measurement accuracy
Controlled parameter
ABC
◦
Temperature, C ± 0,5 ± 1 ± 2
Rotational speed, % ± 0,5 ± 1 ± 2
Input signal, % ± 0,5 ± 1,5 ± 2,5
a
See Annex A.
7 Tests of steady-state performance characteristics
7.1 General
7.1.1 The test circuit and measuring circuit shall conform to Figures 1 or 2 as applicable.
NOTE In addition to the internal control pressure supply as shown in Figure 2, it is possible to use an external control
pressure supply.
7.1.2 Adjust the electric motor to the specified rotational speed.
7.1.3 The steady-state performance shall be determined in accordance with ISO 4409.
7.1.4 For pumps in accordance with Figure 2, the swivel angle or stroke in percent of the maximum value may
be used as an alternative to the output flow.
7.2 Flow/pressure characteristics
7.2.1 Use the pump having pressure control and flow control functions.
©
ISO 2003 – All rights reserved 5
---------------------- Page: 13 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
7.2.2 Determine the minimum flow command by the following procedure:
— set the loading valve to shut-off so that there is no output flow;
— slowly decrease the input flow command signal until the deadhead pressure can no longer be maintained;
— record the value of the input flow command signal as the minimum flow set point.
7.2.3 Tests should be performed at 100 %, 75 % and 50 % of the maximum working pressure. Tests should
90 % 75 % 50 % 25 %
also be performed at , , and of the maximum output flow, and minimum flow command.
7.2.4 Gradually change the output pressure by adjusting the variable restrictor, cycling the pump from the
maximum working pressure, through 75 % and 50 % of the maximum working pressure, to the highest minimum
controllable pressure and output pressure when the variable restrictor is opened completely, and back again.
7.2.5 Plot a graph of output flow against output pressure (see Figure 3).
a
Maximum flow command.
b
Minimum flow command.
c
Minimum controllable pressure.
d
Pressure range from starting pressure-compensation state to deadhead pressure.
e
Hysteresis at pressure-compensation.
f
Maximum width of the change of the output flow.
g
Maximum working pressure.
Figure 3 — Output flow versus pressure
7.2.6 Calculate and record the rate of change of adjustable flow rate δq against output pressure using the
following formula:
∆q
e,1
δq= × 100
q
0
©
6 ISO 2003 – All rights reserved
---------------------- Page: 14 ----------------------
SIST ISO 17559:2005
ISO 17559:2003(E)
where
δq is the rate of change in adjustable flow rate, expressed as a percentage;
∆q is the maximum width of the change of output flow (see Figure 3);
e,1
q is the output flow at the minimum controllable pressure for each input flow command signal as
0
explained below.
Calculate the values at 75 % and 50 % of the maximum output flow and minimum flow command settings,
respectively (these values are the rate of change of adjustable flow rate δq against output pressure). For a pump
with pressure-compensation function, ∆q shall be considered the maximum range of flow rate change
e,1
immediately before the pump shifts into pressure-compensation mode.
7.2.7 For a pump with pressure-compensation function, calculate and record the following characteristic
values for each flow rate setting:
— hysteresis ∆p of the pressure when controlled by the pressure compensator;
e,2
— pressure range ∆p from commencement of pressure compensation to deadhead condition.
e,1
7.3 Characteristic test on output pressure against input pressure command signal: test
procedure and presentation of test results
7.3.1 If the pump has pressure control and flow control functions, select input pressure command signal and
input flow command signal, and adjust them to their maximum values.
7.3.2 Completely close the loading valve. Increase and decrease input pressure command signal for one
cycle, from the minimum controllable pressure of the pump to the maximum working pressure, at a rate that
does not subject the pump or measuring equipment to an
...
NORME ISO
INTERNATIONALE 17559
Première édition
2003-11-15
Transmissions hydrauliques — Pompes
hydrauliques à commande électrique —
Méthodes d'essai pour déterminer les
caractéristiques de fonctionnement
Hydraulic fluid power — Electrically controlled hydraulic pumps — Test
methods to determine performance characteristics
Numéro de référence
ISO 17559:2003(F)
©
ISO 2003
---------------------- Page: 1 ----------------------
ISO 17559:2003(F)
PDF — Exonération de responsabilité
Le présent fichier PDF peut contenir des polices de caractères intégrées. Conformément aux conditions de licence d'Adobe, ce fichier
peut être imprimé ou visualisé, mais ne doit pas être modifié à moins que l'ordinateur employé à cet effet ne bénéficie d'une licence
autorisant l'utilisation de ces polices et que celles-ci y soient installées. Lors du téléchargement de ce fichier, les parties concernées
acceptent de fait la responsabilité de ne pas enfreindre les conditions de licence d'Adobe. Le Secrétariat central de l'ISO décline toute
responsabilité en la matière.
Adobe est une marque déposée d'Adobe Systems Incorporated.
Les détails relatifs aux produits logiciels utilisés pour la création du présent fichier PDF sont disponibles dans la rubrique General Info du
fichier; les paramètres de création PDF ont été optimisés pour l'impression. Toutes les mesures ont été prises pour garantir l'exploitation
de ce fichier par les comités membres de l'ISO. Dans le cas peu probable où surviendrait un problème d'utilisation, veuillez en informer
le Secrétariat central à l'adresse donnée ci-dessous.
© ISO 2003
Droits de reproduction réservés. Sauf prescription différente, aucune partie de cette publication ne peut être reproduite ni utilisée sous
quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit
de l'ISO à l'adresse ci-après ou du comité membre de l'ISO dans le pays du demandeur.
ISO copyright office
Case postale 56 CH-1211 Geneva 20
Tel. + 41 22 749 01 11
Fax + 41 22 749 09 47
E-mail copyright@iso.org
Web www.iso.org
Publié en Suisse
©
ii ISO 2003 – Tous droits réservés
---------------------- Page: 2 ----------------------
ISO 17559:2003(F)
Sommaire Page
1 Domaine d'application . 1
2Références normatives . 1
3 Termes et définitions . 1
4 Symboles . 2
5 Installation d'essai — Exigences générales . 2
5.1 Généralités . 2
5.2 Appareillage général d'essai . 4
6 Conditions générales d'essai . 5
6.1 Fluide d'essai . 5
6.2 Conditions ambiantes . 5
6.3 Conditions en régime permanent . 5
7 Essais des caractéristiques de performance en régime permanent . 5
7.1 Généralités . 5
7.2 Caractéristiques débit/pression . 6
7.3 Essai caractéristique sur la pression de sortie en fonction du signal de commande de la pression
d'entrée: Mode opératoire d'essai et présentation des résultats d'essai . 7
7.4 Essai caractéristique sur le débit de sortie en fonction du signal d'entrée: Mode opératoire d'essai
et expression des résultats d'essai . 9
7.5 Essai de répétabilité . 10
7.6 Essai relatif aux changements des caractéristiques en fonction de la température de l'huile . 12
8 Essais de fonctionnement dynamique . 14
8.1 Généralités . 14
8.2 Réponse et récupération du compensateur de pression . 14
8.3 Essai de réponse transitoire en fonction de la pression de sortie: Mode opératoire d'essai et
présentation des résultats d'essai . 15
8.4 Essai de réponse transitoire en fonction du débit de sortie: Mode opératoire d'essai et
présentation des résultats d'essai . 16
8.5 Réponse en fréquence . 18
Annexe A (normative) Classes d'exactitude de mesure . 21
Bibliographie . 22
©
ISO 2003 – Tous droits réservés iii
---------------------- Page: 3 ----------------------
ISO 17559:2003(F)
Avant-propos
L'ISO (Organisation internationale de normalisation) est une fédération mondiale d'organismes nationaux de
normalisation (comités membres de l'ISO). L'élaboration des Normes internationales est en général confiée
aux comités techniques de l'ISO. Chaque comité membre intéressé par une étude a le droit de faire partie du
comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l'ISO participent également aux travaux. L'ISO collabore étroitement avec la
Commission électrotechnique internationale (CEI) en ce qui concerne la normalisation électrotechnique.
Les Normes internationales sont rédigées conformément aux règles données dans les Directives ISO/CEI,
Partie 2.
La tâche principale des comités techniques est d'élaborer les Normes internationales. Les projets de Normes
internationales adoptés par les comités techniques sont soumis aux comités membres pour vote. Leur
publication comme Normes internationales requiert l'approbation de 75 % au moins des comités membres
votants.
L'attention est appelée sur le fait que certains des éléments du présent document peuvent faire l'objet de droits
de propriété intellectuelle ou de droits analogues. L'ISO ne saurait être tenue pour responsable de ne pas avoir
identifié de tels droits de propriété et averti de leur existence.
L'ISO 17559 a été élaborée par le comité technique ISO/TC 131, Transmissions hydrauliques et pneumatiques,
sous-comité SC 8, Essais des produits.
©
iv ISO 2003 – Tous droits réservés
---------------------- Page: 4 ----------------------
ISO 17559:2003(F)
Introduction
La présente Norme internationale a pour objet d'unifier les méthodes d'essai des pompes hydrauliques à
commande électrique et électronique à déplacement positif, afin de permettre la comparaison des
performances des différents composants.
Elle décrit les exigences relatives aux installations d'essai, aux modes opératoires et à l'expression des
résultats.
©
ISO 2003 – Tous droits réservés v
---------------------- Page: 5 ----------------------
.
vi
---------------------- Page: 6 ----------------------
NORME INTERNATIONALE ISO 17559:2003(F)
Transmissions hydrauliques — Pompes hydrauliques à
commande électrique — Méthodes d'essai pour déterminer les
caractéristiques de fonctionnement
1 Domaine d'application
La présente Norme internationale spécifie les méthodes d'essai pour déterminer les caractéristiques de
fonctionnement en régime permanent et les caractéristiques de fonctionnement dynamique des pompes
hydrauliques à commande électrique et électronique à déplacement positif [désignées ci-après «pompe(s)»],
afin de permettre la comparaison des performances des différents composants.
Les pompes faisant l'objet de la présente Norme internationale sont susceptibles de modifier le débit ou la
pression de sortie en proportion des signaux d'entrée électriques ou électroniques. Ces pompes peuvent être à
commande de détection de charge, à servocommande ou à cylindrée variable électrique, qui commandent le
débit et la pression de sortie par rétroaction grâce à des signaux électriques.
L'exactitude de mesure se divise en trois classes, A, B et C, explicitées dans l'Annexe A.
2Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les
références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du
document de référence s'applique (y compris les éventuels amendements).
ISO 3448, Lubrifiants liquides industriels — Classification ISO selon la viscosité
ISO 4391, Transmissions hydrauliques — Pompes, moteurs et variateurs — Définitions des grandeurs et lettres
utilisées comme symboles
ISO 4406, Transmissions hydrauliques — Fluides — Méthode de codification du niveau de pollution particulaire
solide
ISO 4409, Transmissions hydrauliques — Pompes, moteurs et variateurs volumétriques — Détermination du
fonctionnement en régime permanent
ISO 5598, Transmissions hydrauliques et pneumatiques — Vocabulaire
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions donnés dans l’ISO 5598 ainsi que les suivants
s'appliquent.
3.1
pompe hydraulique à commande électrique
pompe à cylindrée variable permettant de commander la pression ou le débit, ou la pression ou le débit
correspondant à un signal d'entrée
©
ISO 2003 – Tous droits réservés 1
---------------------- Page: 7 ----------------------
ISO 17559:2003(F)
3.2
écoulement minimal commandé
signal de commande d'écoulement d'entrée minimal nécessaire pour maintenir la pression maximale de
fonctionnement
3.3
pression minimale de commande
pression minimale de sortie lorsque la valeur absolue du signal de commande de la pression d'entrée est égale
à zéro et le signal de commande du débit d'entrée est maximal (voir 7.2.4)
3.4
plage d'insensibilité
plage dans laquelle la pression de sortie ou le débit de sortie commandés par le signal d'entrée ne varie pas
lorsque la valeur absolue du signal d'entrée dépasse zéro ou tend vers zéro
3.5
volume de charge
volume brut du fluide de fonctionnement dans les conduites principales entre la sortie de la pompe soumise à
l'essai et l'entrée du distributeur de charge
3.6
compensation de pression
état dans lequel le débit de sortie commence à diminuer par le mécanisme de commande à cylindrée variable
lorsque la pression de sortie tend vers une pression donnée
3.7
pression bloquée
pression de sortie à débit de sortie nul
4 Symboles
4.1 Les symboles littéraux des grandeurs physiques et leurs indices utilisés dans la présente Norme
internationale (voir Tableau 1) sont explicités dans l'ISO 4391.
Les unités sont données dans le Tableau 1 et dans l'Annexe A.
4.2 Les symboles graphiques représentés aux Figures 1 et 2 présentant les schémas de circuits d'essai sont
conformes à l'ISO 1219-1.
Tableau 1 — Symboles et unités
a
Grandeur Symbole Dimension Unité SI
2 –3
Puissance P M L T W
–1 –2
Pression, pression différentielle p, M∆p L T MPa
3 –1 3
Débit q L T dm /min
–1 –1
Vitesse de rotation n T min
a
M = mass, L = longueur, T = temps
5 Installation d'essai — Exigences générales
5.1 Généralités
5.1.1 Sauf spécifications contraires, installer la pompe avec l'arbre de sortie à l'horizontale et l'orifice
d'évacuation orienté vers le haut.
©
2 ISO 2003 – Tous droits réservés
---------------------- Page: 8 ----------------------
ISO 17559:2003(F)
5.1.2 Utiliser un circuit d'essai hydraulique conforme à la Figure 1 pour les pompes d'essai comportant une
vanne de régulation de pression permettant de commander la pression dans l'état compensation de pression et
une vanne de réglage permettant de commander le débit de sortie.
5.1.3 Utiliser un circuit d'essai hydraulique conforme à la Figure 2 pour les pompes d'essai qui utilisent des
signaux d'entrée électriques pour commander la pression dans l'état compensation de pression et la position
ou l'angle du mécanisme pour faire varier la cylindrée de la pompe.
Légende
1 pompe
soumise à
l’essai
2 distributeur de
charge
3 vanne de
régulation
directionnelle
4 restriction
variable
5 torsiomètre
6 indicateur de
couple
7 indicateur de
vitesse
8 capteur de
pression
électrique
9 manomètre
10 capteur de
débit
électrique
11 thermomètre
12 dispositif de
commande
13 source du
signal
14 dispositif de
commande
15 source du
signal
16 enregistreur
17 moteur
électrique
18 clapet de
décharge
manuel
NOTE Les détails relatifs aux vannes de régulation de la pompe sont donnés uniquewment à titre d’illustration.
Figure 1 — Pompe avec vanne de régulation de la compensation de pression et du débit pour réguler le
débit de sortie
©
ISO 2003 – Tous droits réservés 3
---------------------- Page: 9 ----------------------
ISO 17559:2003(F)
Légende
1 pompe soumise à
l’essai
2 distributeur de charge
3 vanne de régulation
directionnelle
4 restriction variable
5torsiomètre
6 indicateur de couple
7 indicateur de vitesse
8 capteur de pression
électrique
9 capteur de débit
électrique
10 manomètre
11 thermomètre
12 dispositif de
commande
13 source du signal
14 enregistreur
15 moteur électrique
16 clapet de décharge
manuel
NOTE Les détails relatifs aux vannes de régulation de la pompe sont donnés uniquement à titre d’illustration.
Figure 2 — Pompe avec signaux d'entrée électriques pour commander la compensation de pression et
la position ou l'angle du mécanisme pour faire varier la cylindrée
5.1.4 Pour des applications où la pompe doit faire partie d'un système de commande en boucle fermée, il peut
être nécessaire d'effectuer un essai de réponse en fréquence. Le paragraphe 8.5 décrit une méthode d'essai de
pompe. Il convient au client et au fabricant de s'accorder sur la nécessité de réaliser cet essai.
5.2 Appareillage général d'essai
5.2.1 Monter un banc d'essai conforme à 5.1.1, 5.1.2 et 5.1.3 et aux Figures 1 et 2, selon le cas.
5.2.2 Maintenir le distributeur de charge et la restriction variable à zéro dans le circuit d'essai, à l'exception des
conditions spécifiées dans le mode opératoire d'essai. Si le distributeur de charge est manœuvré, ouvrir
complètement la restriction variable et régler la vanne de régulation directionnelle de sorte que l'orifice P soit
fermé. Si la restriction variable est manœuvrée, régler la vanne de régulation directionnelle de sorte que
l'orifice P s'ouvre vers l'orifice A.
©
4 ISO 2003 – Tous droits réservés
---------------------- Page: 10 ----------------------
ISO 17559:2003(F)
5.2.3 Régler la vanne de décharge manuelle intégrée à la pompe à titre de sécurité de manière à limiter la
pression maximale en régime permanent au moins à 125 % de la pression de fonctionnement maximale.
6 Conditions générales d'essai
6.1 Fluide d'essai
6.1.1 Le type et la viscosité du fluide hydraulique doivent être conformes à l'ISOVG 32 ou à l'ISO VG 46
conformément à l'ISO 3448.
◦ ◦
6.1.2 Maintenir la température du fluide à l'entrée de la pompe dans la plage de 45 C5 à .5 C
6.1.3 Maintenir la classe de contamination du fluide dans la gamme 19/16 ou moins, conformément à
l'ISO 4406.
Il convient que les conditions autres que celles indiquées dans le présent paragraphe fassent l'objet d'un accord
entre le fournisseur et le client.
6.2 Conditions ambiantes
La température ambiante et toute perturbation des conditions d'air doit être enregistrée.
6.3 Conditions en régime permanent
Effectuer chaque série de mesures seulement lorsque les valeurs des paramètres commandés sont dans les
limites données dans le Tableau 2.
Tableau 2 — Limites de variations admissibles des valeurs des paramètres commandés
Limites de variations admissibles des valeurs des paramètres
a
commandés pour une classe d’exactitude de mesure
Paramètre commandé
ABC
◦
Température, C ± 0,5 ± 1 ± 2
Vitesse de rotation, % ± 0,5 ± 1 ± 2
Signal d'entrée, % ± 0,5 ± 1,5 ± 2,5
a
Voir Annexe A.
7 Essais des caractéristiques de performance en régime permanent
7.1 Généralités
7.1.1 Le circuit d'essai et le circuit de mesure doivent être conformes aux Figures 1 ou 2, selon le cas.
NOTE Outre la source de pression d'utilisation interne représentée à la Figure 2, il est possible d'utiliser une source de
pression d'utilisation externe.
7.1.2 Régler le moteur électrique à la vitesse de rotation spécifiée.
7.1.3 Les performances en régime permanent doivent être déterminées conformément à l'ISO 4409.
7.1.4 Pour les pompes conformes à la Figure 2, l'angle de pivotement ou la course en pourcentage de la
valeur maximale peut être utilisée au lieu du débit de sortie.
©
ISO 2003 – Tous droits réservés 5
---------------------- Page: 11 ----------------------
ISO 17559:2003(F)
7.2 Caractéristiques débit/pression
7.2.1 Utiliser une pompe ayant des fonctions de régulation de la pression et du débit.
7.2.2 Déterminer l'écoulement minimal commandé en respectant le mode opératoire suivant:
— régler le distributeur de chargement sur isolement pour qu'il n'y ait aucun débit de sortie;
— réduire lentement le signal de commande du débit d'entrée jusqu'à ce que la pression bloquée ne puisse
plus être maintenue;
— enregistrer la valeur du signal de commande du débit d'entrée comme le point de réglage du débit minimal.
7.2.3 Il convient de réaliser les essais à 100 %, 75 % et 50 % de la pression de fonctionnement maximale. Il
convient de réaliser aussi les essais à , , 90 % 75 % 50 %et 25 %du débit maximal de sortie et à l'écoulement
minimal commandé.
7.2.4 Modifier progressivement la pression de sortie en réglant la restriction variable, en faisant passer la
pompe de la pression de fonctionnement maximale à la plus grande pression minimale de commande et
pression de sortie lorsque la restriction variable est complètement ouverte, en passant par une pression de
75 % et de 50 % de la pression maximale de fonctionnement, et inversement.
7.2.5 Tracer un graphique du débit de sortie en fonction de la pression de sortie (voir Figure 3).
7.2.6 Calculer et enregistrer le taux de variation du débit réglable δq en fonction de la pression de sortie à
l'aide de la formule suivante:
∆q
e,1
δq= × 100
q
0
où
δq est le taux de variation du débit réglable, exprimé en pourcentage;
∆q est la variation maximale du débit de sortie (voir Figure 3);
e,1
q est le débit de sortie à la pression minimale de commande pour chaque signal de commande du
0
débit d'entrée comme expliqué ci-dessous.
Calculer les valeurs à 75 %et 50 %du débit de sortie maximal et du débit minimal réglables, respectivement
(ces valeurs correspondent au taux de variation du débit réglable δq en fonction de la pression de sortie). Pour
une pompe comportant une fonction compensation de pression, ∆q doit être considéré comme la plage
e,1
maximale de variation du débit juste avant que la pompe ne passe en mode compensation de pression.
7.2.7 Pour une pompe comportant une fonction compensation de pression, calculer et enregistrer les
caractéristiques suivantes pour chaque réglage de débit:
— hystérésis ∆p de la pression lorsque commandée par le compensateur de pression;
e,2
— plage de pressions ∆p entre le début de compensation de pression et la condition bloquée.
e,1
©
6 ISO 2003 – Tous droits réservés
---------------------- Page: 12 ----------------------
ISO 17559:2003(F)
a
Écoulement maximal commandé.
b
Écoulement minimal commandé.
c
Pression minimale de commande.
d
Plage de pressions entre le début de l’état compensation de pression et la pression bloquée.
e
Hystérésis à compensation de pression.
f
Variation maximale du débit de sortie.
g
Pression de fonctionnement maximale.
Figure 3 — Débit de sortie en fonction de la pression de sortie
7.3 Essai caractéristique sur la pression de sortie en fonction du signal de commande de la
pression d'entrée: Mode opératoire d'essai et présentation des résultats d'essai
7.3.1 Si la pompe comporte des fonctions de régulation de la pression et du débit, choisir le signal de
commande de la pression d'entrée et le signal de commande du débit d'entrée, et les régler à leurs valeurs
maximales.
7.3.2 Fermer complètement le distributeur de charge. Augmenter et diminuer le signal de commande de la
pression d'entrée pour un cycle, en passant de la pression minimale de commande de la pompe à la pression
de fonctionnement maximale, à une vitesse adéquate pour que ni la pompe ni les appareils de mesure ne
subissent d'effet dynamique significatif.
7.3.3 Tracer une courbe représentant la pression de sortie en fonction du signal de commande de la pression
d'entrée (voir Figure 4).
©
ISO 2003 – Tous droits réservés 7
---------------------- Page: 13 ----------------------
ISO 17559:2003(F)
a
Plage d'insensibilité.
b
Différence maximale de pression.
c
Plage réglable de pressions.
d
Pression de fonctionnement maximale.
e
Pression minimale de commande.
f
10 % de la pression minimale de commande.
Figure 4 — Pression de sortie en fonction du signal d'entrée
7.3.4 Obtenir et enregistrer les valeurs caractéristiques suivantes à partir des données enregistrées:
∆p
max
δp = × 100
hy
p
max
où
δp est l'hystérésis de la pression de sortie, exprimée en pourcentage;
hy
∆p est la différence maximale de pression pour le même signal d'entrée;
max
p est la pression de fonctionnement maximale.
max
7.3.5 Obtenir la plage réglable des pressions de sortie à partir des données enregistrées.
7.3.6 Obtenir la valeur du signal d'entrée à la pression de fonctionnement maximale à partir des données
enregistrées.
7.3.7 Déterminer la plage d'insensibilité en enregistrant la variation du signal de commande de la pression
d'entrée causant la pression de sortie bloquée par augmentation de 10 % au-dessus de la pression minimale
de commande (voir Figure 4). Enregistrez la plage d'insensibilité à partir des données enregistrées.
©
8 ISO 2003 – Tous droits réservés
---------------------- Page: 14 ----------------------
ISO 17559:2003(F)
7.4 Essai caractéristique sur le débit de sortie en fonction du signal d'entrée: Mode
opératoire d'essai et expression des résultats d'essai
7.4.1 Si la pompe comporte des fonctions régulation de pression et régulation de débit, choisir le signal de
commande de la pression d'entrée et le signal de commande du débit d'entrée et les régler à leurs valeurs
maximales. Régler le signal de commande de la pression d'entrée à 75 % de la pression maximale de
fonctionnement et le débit d'entrée à son maximum, en utilisant le distributeur de charge.
7.4.2 Augmenter puis diminuer le signal de commande du débit d'entrée pour un cycle, en passant d'un débit
de sortie nul au débit de sortie maximal et inversement, à une vitesse adéquate pour que ni la pompe ni les
appareils de mesure ne subissent d'effet dynamique significatif.
7.4.3 Tracer une courbe représentant le débit de sortie en fonction du signal d'entrée (voir Figure 5).
a
Plage d'insensibilité.
b
Différence maximale de débit de sortie.
c
Plage réglable de débits de sortie.
d
Débit de sortie maximal.
Figure 5 — Débit de sortie en fonction du signal d'entrée à 75 % de la pression de fonctionnement
maximale
7.4.4 Calculer et enregistrer les valeurs caractéristiques suivantes à partir des données enregistrées:
∆q
max
δq = × 100
hy
q
max
où
δq est l'hystérésis du débit de sortie, exprimée en pourcentage;
hy
∆q est la différence maximale de débit de sortie pour le même signal d'entrée;
max
q est le débit de sortie maximal.
max
©
ISO 2003 – Tous droits réservés 9
---------------------- Page: 15 ----------------------
ISO 17559:2003(F)
7.4.5 Obtenir la plage réglable de débits de sortie à partir des données enregistrées.
7.4.6 Obtenir la valeur du signal d'entrée au débit de sortie maximal à partir des données enregistrées.
7.4.7 Enregistrer la plage d'insensibilité à partir des données enregistrées (voir Figure 5).
7.5 Essai de répétabilité
7.5.1 Répétabilité de la pression de sortie: Mode opératoire d'essai et présentation des résultats
d'essai
7.5.1.1 Si la pompe comporte des fonctions de régulation de la pression et du débit, choisir le signal de
commande de la pression d'entrée et le signal de commande du débit d'entrée, et les régler à leurs valeurs
maximales.
7.5.1.2 Faire varier progressivement 20 fois le signal de commande de la pression d'entrée conformément à
7.3.2, pour atteindre la pression de fonctionnement maximale et 50 % de cette dernière.
7.5.1.3 Faire varier progressivement 20 fois le signal de commande de la pression d'entrée conformément à
7.3.2, pour atteindre 50 % de la pression de fonctionnement maximale et la pression minimale de commande.
7.5.1.4 Enregistrer graphiquement les résultats des essais selon 7.5.1.2 et 7.5.1.3, avec la pression de sortie
en fonction du temps (voir Figure 6).
a
Signal .100 %
b
Signal 0% pression minimale réglable.
Figure 6 — Répétabilité de la pression de sortie
©
10 ISO 2003 – Tous droits réservés
---------------------- Page: 16 ----------------------
ISO 17559:2003(F)
7.5.1.5 Obtenir et enregistrer le rapport de dispersion pour chaque réglage de pression (voir Figure 6), à l'aide
de la formule suivante:
∆p
e,max
δp = × 100
re
p
max
où
δp est la répétabilité de la pression de sortie, exprimée en pourcentage;
re
∆p est la valeur maximale (∆p à );∆p
e,max e,3 e,6
p est la pression de fonctionnement maximale (voir Figure 6).
max
7.5.2 Répétabilité du débit de sortie: Mode opératoire d'essai et présentation des résultats d'essai
7.5.2.1 Si la pompe comporte des fonctions de régulation de la pression et du débit, choisir le signal de
commande de la pression d'entrée et le signal de commande du débit d'entrée et les régler à leurs valeurs
maximales. Régler le signal de commande de la pression d'entrée à 75 % de la pression maximale de
fonctionnement et régler le signal de commande du débit d'entrée à son maximum, en utilisant le distributeur de
charge.
7.5.2.2 Le débit de sortie de la pompe étant à 90 % du maximum, régler le distributeur de charge de sorte que
la pression atteigne 75 % de la pression maximale de fonctionnement. Faire varier progressivement 20 fois le
signal de commande du débit d'entrée, pour atteindre 90 % et 50 % du débit maximal de sortie à une vitesse
adéquate pour que ni la pompe ni les appareils de mesure ne subissent d'effet dynamique.
7.5.2.3 Le débit de sortie de la pompe étant à 50 % du maximum, régler le distributeur de charge de sorte que
la pression atteigne 75 % de la pression maximale de fonctionnement. Faire varier progressivement 20 fois le
signal d'entrée conformément à 7.5.2.2, pour atteindre 50 % du débit maximal de sortie et l'écoulement minimal
commandé à une vitesse adéquate pour que ni la pompe ni les appareils de mesure ne subissent d'effet
dynamique.
7.5.2.4 Enregistrer graphiquement les résultats d'essai selon 7.5.2.2 et 7.5.2.3, en portant le temps en
abscisse et le débit de sortie en ordonnée (voir Figure 7).
7.5.2.5 Obtenir et enregistrer le rapport de dispersion pour chaque réglage de débit (voir Figure 7), à l'aide de
la formule suivante:
∆q
e,max
δq = × 100
re
q
max
où
δq est la répétabilité du débit de sortie, exprimée en pourcentage;
re
∆q est la valeur maximale (∆q à );∆q
e,max e,2 e,5
q est le débit de sortie maximal (voir Figure 5).
max
©
ISO 2003 – Tous droits réservés 11
---------------------- Page: 17 ----------------------
ISO 17559:2003(F)
a
Signal .90 %
b
Signal 0%débit minimal réglable.
Figure 7 — Répétabilité du débit de sortie
7.6 Essai relatif aux changements des caractéristiques en fonction de la température de
l'huile
7.6.1 Changement de caractéristiques en fonction de la pression: Mode opératoire d'essai et
présentation des résultats d'essai
7.6.1.1 Si la pompe a une fonction de régulation de pression, fermer complètement le distributeur de charge et
maintenir le signal de commande de la pression d'entrée pour atteindre la pression maximale de
fonctionnement.
◦ ◦
7.6.1.2 Faire passer la température de l'huile de 30C7 à 0 C à une vitesse permettant la stabilité des
températures de l'équipement d'essai.
Si cette plage de températures est considérée comme insuffisante pour influer sur la régulation, il convient que
les parties concernées conviennent d'une plage différente de celle indiquée ci-dessus.
7.6.1.3 Enregistrer graphiquement les résultats sur une courbe indiquant la pression de sortie en fonction de
la température de l'huile (voir Figure 8). Enregistrer la température à l'air libre. Si la température ne peut pas
◦
être enregistrée en continu, tracer au moins cinq points à intervall
...