SIST EN 50516-3-1:2014
(Main)Industrial connector sets and interconnect components to be used in optical fibre control and communication systems - Product specifications -- Part 3-1: Type ODVA APC terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3
Industrial connector sets and interconnect components to be used in optical fibre control and communication systems - Product specifications -- Part 3-1: Type ODVA APC terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3
1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which an ODVA (factory terminated) or ODVA fusion splice on connector (FSOC) terminated with cylindrical composite titanium APC ferrules with one side protected by an industrial housing, an adaptor fitted with resilient alignment sleeve and patchcord shall meet in order for it to be categorised as an EN standard product. The product is rated IP67. Since different variants are permitted, product marking details are given in 3.6. 1.2 Intermateability Products conforming to the requirements of this specification will inter mate and give the specified level of random attenuation and random return loss performance provided the same fibre type is used. The intention is that this will be true irrespective of the manufacturing source(s) of the product. When intermating plug variants with different attenuation grades, the resulting level of attenuation cannot be assured to be any better than the worst attenuation grade. The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation performance. Table 1 — Ensured level of random attenuation Plug variant/Attenuation grade C B C C C B C B 1.3 Operating environment The tests selected combined with the severities and durations, specified as Category I, are intended to reflect, although they do not necessarily satisfy all the requirements of, the boundary conditions of M3I3C3E3. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme.
Industrie-Steckverbindersätze und Verbindungsbauelemente für Lichtwellenleiter-Steuerungs- und Datenübertragungssysteme - Produktnormen - Teil 3-1: Industriesteckverbinder der Bauart ODVA-APC zum Anschluss an Einmodenfasern der Typen B1.1 und B1.3 nach EN 60793-2-50 für die Kategorie I (Industrieumgebung) nach den Festlegungen in EN 50173-1 und IEC 61753-1-3
Die vorliegende Spezifikation enthält die Anfangsanforderungen, die Maßanforderungen, die optischen und mechanischen Anforderungen am Anfang der Lebensdauer sowie die umweltbezogenen Anforderungen an das Betriebsverhalten, die ein ODVA-Steckverbinder (vorkonfektioniert) (Open DeviceNet - Vendors Association) oder ein mit zylindrischer Titanium-Komposit-APC-Ferrule konfektionierter ODVA-Steckverbinder mit einem Fusionsspleiß (FSOC), der an einer Seite von einem Industriegehäuse geschützt wird, mit einem Adapter mit elastischer Zentrierhülse und Verbindungskabel erfüllen muss, um als EN-Normprodukt eingestuft zu werden. Das Produkt ist für die Schutzart IP67 bemessen.
Da verschiedene Varianten zulässig sind, werden in 3.6 Einzelheiten zur Produktkennzeichnung angegeben.
Jeux de connecteurs industriels et composants d’interconnexion à utiliser dans les systèmes de communication et de commande par fibres optiques - Spécifications de produits - Partie 3-1: Type ODVA APC câblé sur fibre unimodale des catégories B1.1 et B1.3 de la norme EN 60793-2-50 pour satisfaire aux exigences de la catégorie I (environnements industriels) comme cela est spécifié dans l'EN 50173-1 et l'IEC 61753-1-3
Sestavi industrijskih konektorjev in povezovalne komponente za optične krmilne in komunikacijske sisteme - Specifikacije izdelkov - 3-1. del: Enorodno vlakno tipa ODVA APC kategorij B1.1 in B1.3, ki ustreza zahtevam kategorije I (industrijska okolja), določenim v EN 50173-1 in IEC 61753-1-3
Ta evropski standard vsebuje začetne dimenzijske, optične, mehanske in okoljske zahteve za delovanje, ki jih mora na začetku svoje življenjske dobe izpolnjevati ODVA (tovarniško spojen) (Open DeviceNet Vendors Association) ali spoj ODVA na povezovalnem priključku (FSOC), ki je zaključen s cilindrično kompozitno tulko APC iz titana, ki je na eni strani zaščitena z industrijskim ohišjem, pretvornik z odporno poravnalno spojko in stikalni kabel, da se lahko kategorizirajo kot izdelki v skladu s standardom EN. Ta izdelek je označen kot IP67. Ker so dovoljene različne izvedbe, so podrobnosti o označevanju izdelkov podane v točki 3.6.
General Information
- Status
- Published
- Public Enquiry End Date
- 14-Mar-2013
- Publication Date
- 12-Aug-2014
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 14-Jul-2014
- Due Date
- 18-Sep-2014
- Completion Date
- 13-Aug-2014
Overview
EN 50516-3-1:2014 defines product specifications for ODVA APC industrial fibre optic connector sets and interconnect components terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre. Intended for Category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3, the standard covers start-of-life dimensional, optical, mechanical and environmental requirements for factory-terminated ODVA plugs and ODVA fusion-splice-on-connectors (FSOC). Typical features include cylindrical composite titanium APC ferrules, an industrial protective housing on one side, resilient alignment-sleeved adaptors, and IP67 sealing.
Key Topics and Requirements
- Product definition and variants: Factory-terminated ODVA plugs and FSOC options; product marking for variant identification.
- Mechanical design: Twist-and-lock coupling, protective shell, outline and mating face dimensions, and adaptor interfaces (LF3 family referenced).
- Optical performance: Specified attenuation classes and return loss:
- Class B: mean attenuation ≤ 0.12 dB; random mate ≤ 0.25 dB for >97% of measurements.
- Class C: mean attenuation ≤ 0.25 dB; random mate ≤ 0.50 dB for >97% of measurements.
- Return loss: ≥ 60 dB when mated, ≥ 55 dB when unmated.
- Environmental & durability: Rated IP67; environmental classification aligned with Category I test severities (boundary conditions of M3I3C3E3), plus mechanical and environmental test sequences and pass/fail criteria.
- Intermateability: Products that conform will intermate with specified random attenuation/return loss provided the same fibre type is used. Mixing attenuation grades can reduce performance - intermating cannot be better than the worst grade.
- Quality & reliability guidance: Expected service life in industrial environment ~20 years; compliance does not guarantee lifetime reliability or manufacturing consistency - use recognized reliability and quality assurance programmes.
- Test and qualification: Dimensional checks, optical measurements, mechanical endurance and environmental tests; reporting and sampling requirements included.
Applications and Users
- Industrial automation and control networks requiring robust singlemode fibre interconnects
- Factory-floor Ethernet and fibre-based I/O systems, railway and transportation control, process industry communications
- Who uses this standard: connector and cable manufacturers, product designers, system integrators, test laboratories, procurement/specification engineers, and certification bodies specifying industrial fibre optic connectors (ODVA APC).
Related Standards
- EN 50173-1 / EN 50173-3 (generic & industrial cabling)
- IEC/EN 61753-1-3 (Category I guidance)
- EN 60793-2-50 (singlemode fibre)
- EN 61754-28 (LF3 connector family)
- EN 61300 series (test & measurement procedures)
- EN 60529 (IP Code), EN 60794-3 (cable specs)
Keywords: EN 50516-3-1, ODVA APC, industrial fibre optic connector, IP67, singlemode fibre, Category I, optical connector specifications, fusion splice on connector (FSOC).
Frequently Asked Questions
SIST EN 50516-3-1:2014 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Industrial connector sets and interconnect components to be used in optical fibre control and communication systems - Product specifications -- Part 3-1: Type ODVA APC terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3". This standard covers: 1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which an ODVA (factory terminated) or ODVA fusion splice on connector (FSOC) terminated with cylindrical composite titanium APC ferrules with one side protected by an industrial housing, an adaptor fitted with resilient alignment sleeve and patchcord shall meet in order for it to be categorised as an EN standard product. The product is rated IP67. Since different variants are permitted, product marking details are given in 3.6. 1.2 Intermateability Products conforming to the requirements of this specification will inter mate and give the specified level of random attenuation and random return loss performance provided the same fibre type is used. The intention is that this will be true irrespective of the manufacturing source(s) of the product. When intermating plug variants with different attenuation grades, the resulting level of attenuation cannot be assured to be any better than the worst attenuation grade. The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation performance. Table 1 — Ensured level of random attenuation Plug variant/Attenuation grade C B C C C B C B 1.3 Operating environment The tests selected combined with the severities and durations, specified as Category I, are intended to reflect, although they do not necessarily satisfy all the requirements of, the boundary conditions of M3I3C3E3. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme.
1.1 Product definition This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements which an ODVA (factory terminated) or ODVA fusion splice on connector (FSOC) terminated with cylindrical composite titanium APC ferrules with one side protected by an industrial housing, an adaptor fitted with resilient alignment sleeve and patchcord shall meet in order for it to be categorised as an EN standard product. The product is rated IP67. Since different variants are permitted, product marking details are given in 3.6. 1.2 Intermateability Products conforming to the requirements of this specification will inter mate and give the specified level of random attenuation and random return loss performance provided the same fibre type is used. The intention is that this will be true irrespective of the manufacturing source(s) of the product. When intermating plug variants with different attenuation grades, the resulting level of attenuation cannot be assured to be any better than the worst attenuation grade. The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation performance. Table 1 — Ensured level of random attenuation Plug variant/Attenuation grade C B C C C B C B 1.3 Operating environment The tests selected combined with the severities and durations, specified as Category I, are intended to reflect, although they do not necessarily satisfy all the requirements of, the boundary conditions of M3I3C3E3. 1.4 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this specification does not guarantee the reliability of the product. This should be predicted using a recognised reliability assessment programme. 1.5 Quality assurance Compliance with this specification does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme.
SIST EN 50516-3-1:2014 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 50516-3-1:2014 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2014
6HVWDYLLQGXVWULMVNLKNRQHNWRUMHYLQSRYH]RYDOQHNRPSRQHQWH]DRSWLþQHNUPLOQH
LQNRPXQLNDFLMVNHVLVWHPH6SHFLILNDFLMHL]GHONRYGHO(QRURGQRYODNQRWLSD
2'9$$3&NDWHJRULM%LQ%NLXVWUH]D]DKWHYDPNDWHJRULMH,LQGXVWULMVND
RNROMDGRORþHQLPY(1LQ,(&
Industrial connector sets and interconnect components to be used in optical fibre control
and communication systems - Product specifications -- Part 3-1: Type ODVA APC
terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to meet the
requirements of category I (industrial environments) as specified in EN 50173-1 and IEC
61753-1-3
Ta slovenski standard je istoveten z: EN 50516-3-1:2014
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 50516-3-1
NORME EUROPÉENNE
EUROPÄISCHE NORM
June 2014
ICS 33.180.20
English Version
Industrial connector sets and interconnect components to be
used in optical fibre control and communication systems -
Product specifications - Part 3-1: Type ODVA APC terminated
on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to
meet the requirements of category I (industrial environments) as
specified in EN 50173-1 and IEC 61753-1-3
Industrie-Steckverbindersätze und
Verbindungsbauelemente für Lichtwellenleiter-Steuerungs-
und Datenübertragungssysteme - Produktnormen - Teil 3-1:
Industriesteckverbinder der Bauart ODVA-APC zum
Anschluss an Einmodenfasern der Typen B1.1 und B1.3
nach EN 60793-2-50 für die Kategorie I
(Industrieumgebung) nach den Festlegungen in EN 50173-
1 und IEC 61753-1-3
This European Standard was approved by CENELEC on 2013-12-23. CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any
alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC
Management Centre or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation
under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the
same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Turkey and the United Kingdom.
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels
© 2014 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Ref. No. EN 50516-3-1:2014 E
Contents
Foreword . 4
1 Scope . 7
1.1 Product definition. 7
1.2 Intermateability . 7
1.3 Operating environment . 7
1.4 Reliability . 7
1.5 Quality assurance . 7
2 Normative references . 8
3 Description . 10
3.1 General . 10
3.2 Plug . 10
3.3 Adaptor . 10
3.4 Materials . 10
3.5 Dimensions . 10
3.6 Colour and marking . 11
4 Variants . 11
4.1 Terminated plug . 11
4.2 Adaptor . 12
4.3 Identification of variants . 12
5 Dimensional requirements . 13
5.1 Outline dimensions . 13
5.2 Mating face and other limit dimensions. 17
6 Tests . 26
6.1 Sample size . 26
6.2 Test and measurement methods . 27
6.3 Test sequence . 27
6.4 Pass/fail criteria . 27
7 Test report . 27
8 Product qualification requirements . 27
8.1 Dimensional and marking requirements . 27
8.2 Optical performance requirements . 28
8.3 Mechanical performance requirements . 29
8.4 Environmental performance requirements . 33
Annex A (informative) Attenuation against reference . 36
A.1 Test details . 36
A.2 Reference LF3 connector details . 36
Annex B (normative) Sample size and product sourcing requirements . 37
Annex C (informative) Details of environmental classification out of EN 50173-1 (MICE) . 38
Annex D (informative) Details of sample construction . 39
Annex E (informative) Patent statement concerning ODVA industrial connectors . 40
Bibliography . 42
- 3 - EN 50516-3-1:2014
Figures
Figure 1a — Outline dimensions — Plug . 13
Figure 1b — Outline dimensions — Plug . 14
Figure 2 — Outline dimensions — Fixed adaptor . 15
Figure 3 — Cut out for fixed adaptor mounting Variant 01 . 16
Figure 4 — Cut out for fixed adaptor mounting Variant 02 . 16
Figure 5 — Plug mating face and other limit dimensions . 17
Figure 5 — Plug mating face and other limit dimensions . 18
Figure 6 — Variant B1 / C1 / C1-FSOC LF3 connector interface . 19
Figure 6 — Variant B1 / C1 / C1-FSOC LF3 connector interface . 20
Figure 7 — Ferrule endface geometry — After termination . 20
Figure 8 — Positioning of fibre core . 21
Figure 9 — Ferrule endface geometry — Allowable undercut . 22
Figure 10 — Variant 01, fixed adaptor . 23
Figure 11 — LF3 adaptor interface . 24
Figure 11 — LF3 adaptor interface . 25
Figure 12 — Pin gauge for adaptor . 26
Figure D.1 — Example of test specimen for Tests 1 – 13 . 39
Figure D.2 — Example of test specimen for Tests 14 – 19 . 39
Tables
Table 1 — Ensured level of random attenuation . 7
Table 2 — Preferred colour scheme . 11
Table 3 — Terminated plug — Plug variants . 11
Table 4 — Terminated plug — Adaptor variants . 12
Table 5 — Identification of plug variants . 12
Table 6 — Identification of adaptor variants . 12
Table 7 — Geometrical parameters . 21
Table 8 — Optical performance requirements . 28
Table 9 — Mechanical performance requirements . 29
Table 10 — Environmental performance requirements . 33
Table A.1 — Attenuation measurement: Test details . 36
Table B.1 — Sample size and product sourcing requirements . 37
Table C.1 — Details of environmental classification out of EN 50173-1 (MICE) . 38
Foreword
This document (EN 50516-3-1:2014) has been prepared by CLC/TC 86BXA, "Fibre optic interconnect,
passive and connectorised components".
The following dates are fixed:
• latest date by which this document has to be
(dop) 2014-12-23
implemented at national level by publication of
an identical national standard or by
endorsement
• latest date by which the national standards
(dow) 2016-12-23
conflicting with this document have to
be withdrawn
EN 50516, Industrial connector sets and interconnect components to be used in optical fibre control and
communication systems — Product specifications, is currently divided in the following parts:
− Part 1-1: Type SC-RJ PC industrial terminated on EN 60793-2-10 category A1a and A1b multimode fibre
to meet the requirements of category I (industrial environments) as specified in IEC/PAS 61753-1-3;
− Part 2-1: Type ODVA PC industrial terminated on EN 60793-2-10 category A1a and A1b multimode fibre
to meet the requirements of category I (industrial environments) as specified in EN 50173-1 and
IEC 61753-1-3;
− Part 3-1: Type ODVA APC terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to
meet the requirements of category I (industrial environments) as specified in EN 50173-1 and
IEC 61753-1-3 [the present document].
CENELEC draws attention to the fact that it is claimed that compliance with this document may involve the
use of a patent concerning ODVA industrial connectors (see declaration in Annex E).
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent
rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.
__________
- 5 - EN 50516-3-1:2014
Industrial connector sets and interconnect components to be used in optical fibre control and communication
systems — Product specifications
Part 3-1: Type ODVA APC terminated on EN 60793-2-50 category B1.1 and B1.3 singlemode fibre to meet
the requirements of category I (industrial environments) as specified in EN 50173-1 and IEC 61753-1-3
Description Performance
Coupling mechanism: Twist and lock with sealing Application: For the use in category I
(industrial environment)
Attenuation B: ≤ 0,12 dB mean
Configuration: Plug / adaptor / with one
(random mate) ≤ 0,25 dB for > 97 %
side of the configuration
factory terminated: of measurements
having a seal and a
protective shell C: ≤ 0,25 dB mean
≤ 0,50 dB for > 97 %
Fibre category: EN 60793-2-50
of measurements
Type B1.1 and B1.3
C: ≤ 0,25 dB mean
Attenuation
≤ 0,50 dB for > 97 %
(random mate)
of measurements
FSOC:
Cable type: See Table 3 Return loss: 1: ≥ 60 dB (mated)
≥ 55 dB (unmated)
Related documents:
EN 50173-1 Information technology — Generic cabling systems — Part 1: General requirements
EN 50173-3 Information technology — Generic cabling systems — Part 3: Industrial premises
EN 60529 Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 60794-3 Optical fibre cables — Part 3: Sectional specification — Outdoor cables (IEC 60794-
3)
EN 61300 series Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures (IEC 61300 series)
EN 61753-1 Fibre optic interconnecting devices and passive components performance
standard — Part 1: General and guidance for performance standards (IEC 61753-1)
1)
FprEN 61753-1-3 Fibre optic interconnecting devices and passive components — Performance standard
— Part 1-3: General and guidance for single-mode fibre optic connector and cable
assembly for harsh industrial environment, Category I (IEC 61753-1-3:201X
(86B/3496/CDV))
EN 61754-28 Fibre optic interconnecting devices and passive components — Fibre optic
connector interfaces — Part 28: Type LF3 connector family
(IEC 61754-28)
1) At draft stage.
Outline and maximum dimensions: ODVA connector plug with protective shell in sealed adaptor.
factory terminated FSOC
- 7 - EN 50516-3-1:2014
1 Scope
1.1 Product definition
This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental
performance requirements which an ODVA (factory terminated) (Open DeviceNet Vendors Association) or
ODVA fusion splice on connector (FSOC) terminated with cylindrical composite titanium APC ferrules with
one side protected by an industrial housing, an adaptor fitted with resilient alignment sleeve and patchcord
shall meet in order for it to be categorised as an EN standard product. The product is rated IP67.
Since different variants are permitted, product marking details are given in 3.6.
1.2 Intermateability
Products conforming to the requirements of this specification will inter mate and give the specified level of
random attenuation and random return loss performance provided the same fibre type is used. The intention
is that this will be true irrespective of the manufacturing source(s) of the product.
When intermating plug variants with different attenuation grades, the resulting level of attenuation cannot be
assured to be any better than the worst attenuation grade.
The intermating of a grade C plug with a grade B plug will result in an uncertain level of random attenuation
performance.
Table 1 — Ensured level of random attenuation
Plug variant/Attenuation grade C B
C C C
B C B
1.3 Operating environment
The tests selected combined with the severities and durations, specified as Category I, are intended to
reflect, although they do not necessarily satisfy all the requirements of, the boundary conditions of M I C E .
3 3 3 3
1.4 Reliability
Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with
this specification does not guarantee the reliability of the product. This should be predicted using a
recognised reliability assessment programme.
1.5 Quality assurance
Compliance with this specification does not guarantee the manufacturing consistency of the product. This
should be maintained using a recognised quality assurance programme.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are
indispensable for its application. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
EN 60068-2-60 Environmental testing — Part 2: Tests — Test Ke: Flowing mixed gas corrosion test
(IEC 60068-2-60)
EN 60529 Degrees of protection provided by enclosures (IP Code) (IEC 60529)
EN 60874-1 Fibre optic interconnecting devices and passive components — Connectors for
optical fibres and cables — Part 1: Generic specification (IEC 60874-1)
EN 61300-2-1 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-1: Tests — Vibration (sinusoidal) (IEC 61300-2-
1)
EN 61300-2-2 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-2: Tests — Mating durability (IEC 61300-2-2)
EN 61300-2-4 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-4: Tests — Fibre/cable retention (IEC 61300-2-4)
EN 61300-2-5 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-5: Tests — Torsion (IEC 61300-2-5)
EN 61300-2-6 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-6: Tests — Tensile strength of coupling
mechanism (IEC 61300-2-6)
EN 61300-2-7 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-7: Tests — Bending moment (IEC 61300-2-7)
EN 61300-2-9 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-9: Tests — Shock (IEC 61300-2-9)
EN 61300-2-10 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-10: Tests — Crush resistance (IEC 61300-2-10)
EN 61300-2-12:2005 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-12: Tests — Impact (IEC 61300-2-12:2005)
EN 61300-2-22 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-22: Tests — Change of temperature
(IEC 61300-2-22)
EN 61300-2-26 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-26: Tests — Salt mist (IEC 61300-2-26)
EN 61300-2-27 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-27: Tests — Dust — Laminar flow
(IEC 61300-2-27)
EN 61300-2-34 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-34: Tests — Resistance to solvents and
contaminating fluids of interconnecting components and closures (IEC 61300-2-34)
EN 61300-2-35 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-35: Tests — Cable nutation (IEC 61300-2-35)
- 9 - EN 50516-3-1:2014
EN 61300-2-46 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-46: Tests — Damp heat cyclic (IEC 61300-2-46)
2)
IEC 61300-2-53 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 2-53: Test — Degrees of protection provided by
fibre optic enclosures (IP Codes 65 and 67)
EN 61300-3-1 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-1: Examinations and measurements — Visual
examination (IEC 61300-3-1)
EN 61300-3-6 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-6: Examinations and measurements — Return
loss (IEC 61300-3-6)
EN 61300-3-15 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-15: Examinations and measurements — Dome
eccentricity of a convex polished ferrule endface (IEC 61300-3-15)
EN 61300-3-16 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-16: Examinations and measurements —
Endface radius of spherically polished ferrules (IEC 61300-3-16)
EN 61300-3-23 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-23: Examination and measurements — Fibre
position relative to ferrule endface (IEC 61300-3-23)
EN 61300-3-28 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-28: Examinations and measurements —
Transient loss (IEC 61300-3-28)
EN 61300-3-34 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-34: Examinations and measurements —
Attenuation of random mated connectors (IEC 61300-3-34)
EN 61300-3-35 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-35: Examinations and measurements — Fibre
optic connector endface visual and automated inspection (IEC 61300-3-35)
2)
EN 61300-3-47 Fibre optic interconnecting devices and passive components — Basic test and
measurement procedures — Part 3-47: Examinations and measurements —
Endface geometry of PC/APC spherically polished ferrules using interferometry
(IEC 61300-3-47)
EN 61754-28 Fibre optic interconnecting devices and passive components — Fibre optic connector
interfaces — Part 28: Type LF3 connector family (IEC 61754-28)
2) At draft stage.
3 Description
3.1 General
The ODVA industrial connector is a duplex plug connector set of plug / adaptor / plug configuration with one
side having a protective shell characterised by two cylindrical, spring loaded butting ferrules of 1,25 mm
nominal diameter and a twist and lock coupling mechanism. The optical alignment mechanism of the
connectors is of a resilient sleeve style.
3.2 Plug
The plug consists of an ODVA connector interface and a housing part. These two parts have to be in the
defined position to each other (see Figures 1a), 1b) and 5) to guarantee correct mating. Sealing is made
between an o-ring (placed on the housing) and the adaptor frame. A cover (dust cap) to protect the ferrule
endface when the plug is in the unmated condition shall be provided. Sealing shall also be guaranteed
between the connector and the dust cap.
The plug features two cylindrical composite titanium ferrules and a push-pull coupling mechanism. Alternative
materials may be used for the ferrule that have directly compatible material properties, but the endface and
performance requirements shall be met under all conditions.
The plug has three male keys to provide the orientation to the duplex connector in relation with the adaptor.
The plug can be either a complete factory terminated version or a fusion splice on connector (FSOC) version.
The fusion splice is located within the sealed housing.
3.3 Adaptor
The adaptor consists of an ODVA adaptor as it is described in this specification and a duplex LF3 adaptor in
a mounting frame. Sealing is made between the connector housing and the adaptor mounting frame. The
mounting frame shall be mounted in a protected area with a gasket to ensure sealing between the adaptor
and the protected area. Preferred cut out dimensions to maintain sealing are given in Figure 3 and Figure 4.
At the rear of the adaptor there are two LF3 simplex connectors.
The adaptor consists of two zirconia ceramic resilient alignment sleeves and two push-pull coupling
mechanisms, one for each sleeve. Alternative materials may be used for the sleeve that have directly
compatible material properties as zirconia but the performance requirements shall be met under all
conditions.
The adaptor housing has three female keys.
Covers (dust caps) shall be provided to protect each duplex port of the adaptor.
3.4 Materials
Materials which are not specified or which are not specifically described are left to the discretion of the
manufacturer.
3.5 Dimensions
Outline dimensions and other dimensions necessary to ensure intermateability or which affect performance
are specified. All other dimensions are left to the discretion of the manufacturer. Where the mating face limit
dimensions are not in agreement with an EN interface standard this is clearly stated.
- 11 - EN 50516-3-1:2014
3.6 Colour and marking
Marking of the product shall be in accordance with EN 60874-1, in the following order of precedence:
a) identification of manufacturer;
b) manufacturing date code: year / week;
c) manufacturers part number;
d) variant identification number.
The preferred colour scheme is given in Table 1.
Table 2 — Preferred colour scheme
ODVA housing
black
LF3 Plug LF3 Adaptor
green green
NOTE The preferred black is 9005 and green is RAL 6018. Other not listed parts
could also be of the preferred colour to show the colour scheme.
4 Variants
4.1 Terminated plug
The following cable variants are permitted:
Table 3 — Terminated plug — Plug variants
Variant number Cable diameter Structure Remarks
B1 5,0 mm – 8,5 mm Reinforced duplex cable The roundness shall be
< 0,2 mm.
0,2 mm
C1 5,0 mm – 8,5 mm Reinforced duplex cable The roundness shall be
< 0,2 mm.
0,2 mm
C1 FSOC 5,0 mm – 8,5 mm Reinforced duplex cable The roundness shall be
< 0,2 mm.
0,2 mm
4.2 Adaptor
The following variants are permitted:
Table 4 — Terminated plug — Adaptor variants
Variant number Format
01 Fixed adaptor
(mounting frame e.g. fixed on a
sealed box / sealed connector
outside)
02 Fixed D hole adaptor
4.3 Identification of variants
The identification numbers for the cable variants and adaptor variants are given in Tables 4 and 5.
Table 5 — Identification of plug variants
Variant number Identification number
B1 EN 50516-3-1-B1
C1 EN 50516-3-1-C1
C1 FSOC EN 50516-3-1-C1-FSOC
Table 6 — Identification of adaptor variants
Variant number Identification number
01 EN 50516-3-1-01
02 EN 50516-3-1-02
- 13 - EN 50516-3-1:2014
5 Dimensional requirements
5.1 Outline dimensions
5.1.1 Plug
Variant No. B1 / C1:
Ref. Dimensions Remarks
min. mm max.
A 110
B 108
C 60 Nominal 52,3
D 30 30,3
K 6,25 Basic dimension
NOTE Drawing shows connectors with protection cap open.
a) Outline dimensions — Plug
Figure 1 — Outline dimensions — Plug (continued)
Variant No. C1 FSOC:
Ref. Dimensions Remarks
min. mm max.
A 137
B 135
C 60 Nominal 52,3
D 30 30,3
K 6,25 Basic dimension
NOTE Drawing shows connectors with protection cap open.
b) Outline dimensions — Plug
Figure 1 — Outline dimensions — Plug (end)
- 15 - EN 50516-3-1:2014
5.1.2 Adaptor
Variant Fixed adaptor:
Ref. Dimensions Remarks
min. mm max.
A 32 35
C 34 35
K 6,25 Basic dimension
Figure 2 — Outline dimensions — Fixed adaptor
Variant 01 Fixed adaptor:
Ref. Dimensions Remarks
min. mm max.
A1 26,6 27,7
A2 2,0 3,1
A3 0,5 1,6
A4 11,9 13,0
Figure 3 — Cut out for fixed adaptor mounting Variant 01
Ref. Dimensions Remarks
min. mm max.
A1 28,4 28,6
A4 12,83 13,03
NOTE Panel cut out dimensions are for recommendation only.
Figure 4 — Cut out for fixed adaptor mounting Variant 02
---------------------- Page
...




Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...