Abstract

Amendment to the published version

Status
Published
Publication Date
30-Nov-2003
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Dec-2003
Due Date
01-Dec-2003
Completion Date
01-Dec-2003

Buy Documents

Amendment

SIST ETS 300 012/A1 E1:2003

English language (13 pages)
Preview
Preview
e-Library read for
×1 day

SIST ETS 300 012/A1 E1:2003 is the Slovene version of ETS 300 012/A1 Edition 1. It is an amendment to the ISDN basic user-network interface Layer 1 specification and test principles, so it updates how Layer 1 behavior is specified and how related tests are performed for terminal equipment and network termination.

What does SIST ETS 300 012/A1 E1:2003 specify?

SIST ETS 300 012/A1 E1:2003 specifies amendments to the published ETS 300 012 Layer 1 standard for the Integrated Services Digital Network (ISDN) basic user-network interface. In practice, it changes selected figures, tables, test clauses and state tables that are used to verify interface behavior and power-related operation.

The amendment is organized as a foreword, a list of amendments, and a history note. The changes touch the main text and the annex material used for TE and NT testing.

AnnexWhat it covers in this amendment
Annex ATE-related requirements and test entries, including power detection, INFO wording, and pulse unbalance
Annex DTE test procedures, state tables, polarity, framing, jitter, and power condition tests
Annex ENT test procedures, polarity, framing, and test configurations

What are the key requirements of SIST ETS 300 012/A1 E1:2003?

This amendment mainly tightens how Layer 1 tests are set up and how results are interpreted. The practical effect is that manufacturers and test labs must use the revised figures, state tables and stimulus/result definitions when checking ISDN user-network interface behavior.

TE-related changes

  • Figure 3 updates the TE power start-up test. This matters because power-on behavior is part of interface conformance, especially for locally powered equipment and phantom-powered operation.
  • Figure 7 updates the test circuit for applied current unbalance. That affects how imbalance is measured and therefore how the test setup must be wired.
  • Annex A, A.5.3.2 adds a disconnect detector requirement for TEs using the automatic assignment procedure. In practice, a TE must detect power source 1 or 2 to establish connection status.
  • Annex A, A.6.2.6.1 changes the wording from INFO2 to INFO2 or INFO4. This broadens the accepted signal conditions in that test entry.
  • Annex A, A.8.5.4 is marked Informative (I) for pulse unbalance. That tells the reader this entry is explanatory rather than a direct compliance requirement.

Test-state and stimulus updates

  • Annex D, D.3.2.1 revises the TE activation state table, including extra notes for locally powered TEs and disconnected detectors. For testing, this means the tester must watch state transitions carefully when power disappears, when the interface signal changes, and when the TE is expected to remain idle until the interface voltage stays below 24 V for a defined time.
  • D.3.2.2.1.1 changes the polarity integrity test in state F3 so it uses INFO2 frames and is performed with both normal and reversed polarity. This is a direct setup instruction for polarity testing.
  • D.3.3 revises the framing-loss and framing-regain results. The practical point is that the test outcome is judged by specific frame-error patterns and by whether framing is regained in the allowed sequence.
  • D.4.2 and D.4.5.2 update jitter-measurement and power-related TE test text, including a defined deactivated-to-synchronised test state sequence.
  • D.5.1.4.2 updates the current/time limitation test for TE when connecting. This is relevant for equipment design because it checks how the TE behaves during connection under restricted power conditions.

NT-related changes

  • Annex E, E.1.4.4 maps polarity integrity to the detailed test in E.3.3.2.1.
  • E.3.3.2.1, Test B uses INFO3 from the TE simulator and requires both normal and reversed polarity. This keeps the NT polarity test aligned with the interface direction being exercised.
  • E.3.4 revises framing-loss and framing-regain results for the NT test sequence.
  • E.5.1.4.3, E.5.1.7, and E.6.1.5 update test configurations involving mains supply and load changes. These changes matter when the NT is verified under changing supply and load conditions.

What terms does SIST ETS 300 012/A1 E1:2003 define?

  • ISDN - Integrated Services Digital Network, the service and interface family covered by the standard.
  • TE - Terminal Equipment, the user-side equipment that is tested against the Layer 1 rules.
  • NT - Network Termination, the network-side equipment used in the NT test clauses.
  • IUT - Item Under Test, the device or setup being exercised in a test.
  • INFO 0 - A Layer 1 signal condition used in the state and framing tests to represent deactivation-related behavior.
  • INFO 2 / INFO 4 - Layer 1 signal conditions used in activation, synchronization and polarity-related tests.
  • PH-AR - Physical layer activation request, used in the state machine tables.
  • PS1 / PS2 - Power source 1 and power source 2, which are important for locally powered TEs and power detection.

Who uses SIST ETS 300 012/A1 E1:2003?

SIST ETS 300 012/A1 E1:2003 is used by telecommunications engineers, test laboratories, and manufacturers of ISDN terminal equipment and network termination equipment. Quality teams and conformity assessment staff use it to set up Layer 1 tests, interpret state transitions, and verify power, polarity, framing and jitter behavior on the user-network interface.

What changed in SIST ETS 300 012/A1 E1:2003 from the previous edition?

SIST ETS 300 012/A1 E1:2003 is Amendment 1 to ETS 300 012 (1992). The amendment replaces or updates figures, tables and subclauses covering power start-up, current unbalance, automatic assignment, polarity integrity, framing, jitter measurement, power conditions, and current/time limitation for TE and NT tests. The history note also records the first edition of ETS 300 012 in April 1992 and Amendment 1 in December 1994.

Which standards are used with SIST ETS 300 012/A1 E1:2003?

This amendment is used with ETS 300 012 (1992), which it modifies. Several amended test clauses also refer back to subclauses of ETS 300 012, so the base standard is needed to use this amendment correctly.

What does the SIST ETS 300 012/A1 E1:2003 document contain?

The document contains replacement figures for TE power start-up, current unbalance, and several mains-supply test configurations. It also contains revised state tables, test stimuli, result criteria, and cross-references for the TE and NT Layer 1 test clauses.

The annex material is used for design checks, laboratory testing, and conformance work on ISDN basic user-network interface equipment. The changes mainly tell the reader how to build the test setup, what stimulus to apply, and how to judge the observed state or frame result.

Buy Documents

Amendment

SIST ETS 300 012/A1 E1:2003

English language (13 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST ETS 300 012/A1 E1:2003 is a amendment published by the Slovenian Institute for Standardization (SIST). Its full title is "Integrated Services Digital Network (ISDN); Basic user-network interface Layer 1 specification and test principles". This standard covers: Amendment to the published version

Amendment to the published version

SIST ETS 300 012/A1 E1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.080 - Integrated Services Digital Network (ISDN). The ICS classification helps identify the subject area and facilitates finding related standards.

SIST ETS 300 012/A1 E1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)


SLOVENSKI STANDARD
01-december-2003
'LJLWDOQRRPUHåMH]LQWHJULUDQLPLVWRULWYDPL ,6'1 ±2VQRYQLYPHVQLNXSRUDEQLN
RPUHåMH±6SHFLILNDFLMDSUYHSODVWLLQQDþHODSUHVNXãDQMD
Integrated Services Digital Network (ISDN); Basic user-network interface Layer 1
specification and test principles
Ta slovenski standard je istoveten z: ETS 300 012/A1 Edition 1
ICS:
33.080 Digitalno omrežje z Integrated Services Digital
integriranimi storitvami Network (ISDN)
(ISDN)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

ETS 300 012
AMENDMENT A1
December 1994
Source: ETSI TC-TM Reference: RE/TM-03039
ICS: 33.080, 33.040.50
ISDN, user network interface, testing
Key words:
This amendment A1 modifies
the European Telecommunication Standard ETS 300 012 (1992)
Integrated Services Digital Network (ISDN);
Basic user-network interface
Layer 1 specification and test principles
ETSI
European Telecommunications Standards Institute
ETSI Secretariat
F-06921 Sophia Antipolis CEDEX - FRANCE
Postal address:
650 Route des Lucioles - Sophia Antipolis - Valbonne - FRANCE
Office address:
c=fr, a=atlas, p=etsi, s=secretariat - secretariat@etsi.fr
X.400: Internet:
Tel.: +33 92 94 42 00 - Fax: +33 93 65 47 16
Copyright Notification: No part may be reproduced except as authorized by written permission. The copyright and the
foregoing restriction extend to reproduction in all media.
© European Telecommunications Standards Institute 1994. All rights reserved.
New presentation - see History box

Page 2
ETS 300 012: April 1992/A1: December 1994
Whilst every care has been taken in the preparation and publication of this document, errors in content,
typographical or otherwise, may occur. If you have comments concerning its accuracy, please write to
"ETSI Editing and Committee Support Dept." at the address shown on the title page.

Page 3
ETS 300 012: April 1992/A1: December 1994
Foreword
This Amendment to ETS 300 012 (1992) has been produced by the Transmission and Multiplexing (TM)
Technical Committee of the European Telecommunications Standards Institute (ETSI).
Amendments
Page 18, figure 3
Replace figure 3 with the following figure:
CL
TE
+
U = 40 V
U = 24 V
Z
C1
S
C2
IUT
-
CS
U : Zener voltage
Z
Figure 3: Power start up test for TE
Page 22, figure 7
Replace figure 7 with the following figure:
R R
±
c/e
S S
R
R ±
L
L
R
L
R d/f
S
TE
U = 40 V
i =
30 mA
=
R = 6 R 360 m
S
S
R R
L
S
=
X =
R 2R
L
S
R = R
5 =
L 300 m
L
Figure 7: Test circuit for applied current unbalance

Page 4
ETS 300 012: April 1992/A1: December 1994
Page 26, table A.1, table entry A.5.3.2
Replace the table entry A.5.3.2 with the following:
A.5.3.2 TEs not powered across the interface
A TE using the automatic assignment
procedure shall implement the
disconnect detector for detection of
power source 1 or 2 to establish the
connection status.
Page 29, table A.1, table entry A.6.2.6.1
Replace the final paragraph for table entry A.6.2.6.1 with the following:
shall be replaced (four times) by:
"INFO2 or INFO4">
Page 31, table A.1, table entry A.8.5.4
The statement ("St.-ment") for table entry A.8.5.4 shall be changed to "I" (Informative), as follows:
Clause/ Title St.-
subclause ment
A.8.5.4 Pulse unbalance I
replaced by:
Page 46, subclause D.1.4.4
Replace the fourth instance of "N/R" with "D.3.2.2.1.1", producing a table as follows:
Modes Clause/ Test defined in
subclause Clause/subclause
Types of wiring configuration A.4 N/R
Point-to-point configuration A.4.1 N/R
Point-to-multipoint A.4.2 N/R
configuration
Polarity Integrity A.4.3 D.3.2.2.1.1
(figure 2/I.430 [2])
Interface Ia A.4.4 N/R
TE associated wiring A.4.5 N/R

Page 5
ETS 300 012: April 1992/A1: December 1994
Page 50, subclause D.1.4.11
Replace the final instance of "N/R" with "D.5.1.4.1" and add test for Annex B, Clause B.6, producing a
table as follows:
Requirements Clause/ Test defined in
subclause Clause/subclause
Test loopbacks defined for the Annex A
basic user-network interface App. I N/R
Additional requirements B.1 to B.5 N/R
applicable to the explicit S B.6 D.5.1.4.2
reference point
TE design to minimise power Annex C D.5.1.4.1
disturbance
Page 57, subclause D.3.2.1
Replace the table in subclause D.3.2.1 with the following table (modifying states 9, 16, 22, 40 and 46 and
adding NOTE 9):
Table to subclause D.3.2.1
STATSTAT CURRENTCURRENT STIMULUSSTIMULUS NOTENOTE NEXTNEXT INFOINFO COMMENTCOMMENT
EE STATESTATE STATSTAT SENTSENT
NONO EE
1 F1 Power 1 F2 I0 Detection of power
2 F1 T3 expires 2/6 F1 I0 No action
3 F2 Loss of Power F1 I0 Return to inactive state
4 F2 Rx INFO 0 4 F3 I0 Assume deactivated state
5 F2 Rx INFO 2 F6 I3 Synchronised state
6 F2 Rx INFO 4 F7 I3 Activated
7 F2 Rx any signal 3 F2 I0 No action
8 F2 T3 expires 6 F2 I0 No action
9 F3 Loss of Power 9 F1 I0 Return to inactive
10 F3 PH-AR F4 I1 Initiate activation & T3
11 F3 Rx INFO 0 4 F3 I0 No action
12 F3 Rx INFO 2 F6 I3 Synchronised state
13 F3 Rx INFO 4 F7 I3 Activated
14 F3 Rx any signal 3 F3 I0 No action
15 F3 T3 expires 2 F3 I0 No action
16 F4 Loss of Power 9 F1 I0 Return to inactive state
17 F4 Rx INFO 0 4 F4 I1 No action
18 F4 Rx INFO 2 7 F6 I3 Synchronised
19 F4 Rx INFO 4 7 F7 I3 Active
20 F4 Rx any signal 3 F5 I0 Detection of signal
21 F4 T3 Expires 2 F3 I0 Deactivated
22 F5 Loss of Power 9 F1 I0 Return to inactive
23 F5 Rx INFO 0 4 F5 I0 No action
24 F5 Rx INFO 2 F6 I3 Synchronised
25 F5 Rx INFO 4 F7 I3 Activated
26 F5 Rx any signal 3 F5 I0 No action
27 F5 T3 Expires 2 F3 I0 Deactivated
28 F6 Loss of Power 8 F1 I0 Return to inactive
29 F6 Lost Framing F8 I0 Loss of framing signals
30 F6 PH-AR F6 I3 No action
(continued)
Page 6
ETS 300 012: April 1992/A1: December 1994
Table to subclause D.3.2.1 (concluded)
STATSTAT CURRENTCURRENT STIMULUSSTIMULUS NOTENOTE NEXTNEXT INFOINFO COMMENTCOMMENT
EE STATESTATE STATSTAT SENTSENT
NONO EE
31 F6 Rx INFO 0 4 F3 I0 Deactivated
32 F6 Rx INFO 2 F6 I3 No action
33 F6 Rx INFO 4 F7 I3 Activated
34 F6 T3 Expires 2 F6 I3 Synchronised
35 F7 Loss of Power 8 F1 I0 Return to inactive
36 F7 Lost Framing F8 I0 Loss of framing
37 F7 Rx INFO 0 4/5 F3 I0 Deactivated
38 F7 Rx INFO 2 F6 I3 Synchronised
39 F7 Rx INFO 4 F7 I3 No action
40 F8 Loss of Power 9 F1 I0 Return to inactive
41 F8 PH-AR F8 I0 No action
42 F8 Rx INFO 0 4/5 F3 I0 Deactivation
43 F8 Rx INFO 2 F6 I3 Synchronised
44 F8 Rx INFO 4 F7 I3 Activated
45 F8 Rx any signal 3 F8 I0 No action
46 F8 T3 expires 2 F3 I0 Assu
...