SIST EN 300 476-5 V1.2.1:2003
(Main)Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Protocol Implementation Conformance Statement (PICS) proforma; Part 5: Data Link Control (DLC) layer - Fixed radio Termination (FT)
- Abstract
Version 2 of the PICS for voluntary testing of ETS 300 175. This update corrects errors which were found during the implementation of the first edition of this document (ETS 300 476-1) and alignment with the second edition of ETS 300 175.
- Status
- Published
- Publication Date
- 30-Nov-2003
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
- Mandate
- T-292
SIST EN 300 476-5 V1.2.1:2003 is the Slovenian adoption of the ETSI standard for the DECT Common Interface Protocol Implementation Conformance Statement (PICS) proforma for the Data Link Control (DLC) layer at the Fixed radio Termination (FT). It tells a supplier how to document what an FT DLC implementation supports so that conformance to EN 300 175-4 can be assessed in a standardized way. The document is published by SIST and is aligned with ETSI EN 300 476-5 V1.2.1.
What does SIST EN 300 476-5 V1.2.1:2003 specify?
SIST EN 300 476-5 V1.2.1:2003 specifies the PICS proforma for the DECT DLC layer at the FT. In practice, it is a questionnaire and reporting format for implementations claimed to conform to EN 300 175-4, with completion guidance taken from ISO/IEC 9646-7.
The document is organized into four main clauses and one normative annex:
- Clause 1 gives the scope.
- Clause 2 lists the normative references.
- Clause 3 gives definitions and abbreviations.
- Clause 4 states the conformance rule for a PICS completed to this specification.
- Annex A contains the full PICS proforma.
| Annex | What it covers |
|---|---|
| A (normative) | PICS proforma for DECT DLC FT, including completion instructions, identification fields, conformance statements, capabilities, parameters, PDUs and error handling |
What are the key requirements of SIST EN 300 476-5 V1.2.1:2003?
SIST EN 300 476-5 V1.2.1:2003 is mainly a documentation requirement, but it is strict about how the PICS is completed. Clause 4 requires the supplier’s completed PICS to be technically equivalent to Annex A and to keep the same numbering, naming and order. That matters because test labs and buyers need to compare statements line by line.
Completion rules
Annex A says the supplier shall fill in the PICS using the notation defined there, and specific instructions appear before each table. The PICS identifies the implementation, the system under test, the protocol being described and the supplier/contact details. In practice, this ensures the statement can be traced to one exact product and configuration.
Conformance reporting
The global statement of conformance asks whether all mandatory capabilities are implemented. A “No” answer means non-conformance, and any missing mandatory capability must be identified with an explanation. That makes the document useful for acceptance checks and for finding gaps before interoperability testing.
Capability coverage
Annex A divides capabilities into services, procedures, timers, protocol parameters, protocol PDUs and error handling. The service tables cover C-plane and U-plane services, including Class U, Class A, Class B and broadcast on the C-plane, and LU1, LU2, LU3, LU5, LU6, LU7, LU8, LU9, LU10 and LU16 on the U-plane. For a reader, this is the core map of what the implementation can do.
Conditional and optional items
The tables use status codes such as mandatory, optional, conditional, prohibited, not applicable and out of scope, together with support entries such as Y, N and N/A. Some items are only required if other selections are supported. This matters because a PICS is not just a checklist - it captures dependencies between features.
Frame, message and field support
Annex A lists the C-plane and U-plane frame structures, message types and field contents in both directions, including items such as address, control, length indicator, information, fill and checksum fields. For testing, this tells users exactly which protocol data units and subfields the implementation claims to parse or generate.
Error handling and recovery
The annex also includes general error handling and class-specific recovery behavior. Unknown and invalid frames are discarded, and Class A and Class B have defined recovery situations such as timer expiry, sequence errors and collisions of commands. That gives labs a basis for checking fault behavior, not only normal traffic.
What terms does SIST EN 300 476-5 V1.2.1:2003 define?
SIST EN 300 476-5 V1.2.1:2003 uses a small set of conformance-testing terms that are central to the document:
- Implementation Conformance Statement (ICS) - a statement from the supplier describing which capabilities of a specification are implemented.
- ICS proforma - a questionnaire-style document that becomes an ICS when it is completed for a specific implementation.
- Protocol Implementation Conformance Statement (PICS) - an ICS for an implementation or system claimed to conform to a protocol specification.
- Implementation Under Test (IUT) - the implementation being examined for conformance.
- System Under Test (SUT) - the system that contains the IUT and is identified in the PICS.
Who uses SIST EN 300 476-5 V1.2.1:2003?
SIST EN 300 476-5 V1.2.1:2003 is used by suppliers of DECT implementations that claim conformance to EN 300 175-4. It is also used by conformance test labs, certification teams, quality managers and buyers who need a structured statement of supported FT DLC functions. In practice, they use it to complete, review or compare PICS documents before testing, acceptance or procurement.
What changed in SIST EN 300 476-5 V1.2.1:2003 from the previous edition?
SIST EN 300 476-5 V1.2.1:2003 is Version 2 of the PICS for voluntary testing of ETS 300 175. It corrects errors found during implementation of the first edition of this document and aligns the proforma with the second edition of ETS 300 175.
Which standards are used with SIST EN 300 476-5 V1.2.1:2003?
- EN 300 175-1 - provides the DECT Common Interface overview and the general terms used in the series.
- EN 300 175-4 - defines the DECT DLC layer that this PICS proforma profiles.
- ISO/IEC 9646-1 - supplies the general conformance testing concepts and the ICS definitions.
- ISO/IEC 9646-7 - provides the rules for Implementation Conformance Statements and the questionnaire format.
- ETS 300 651 - is referenced for the generic data link service, including service type C, class 2.
What does the SIST EN 300 476-5 V1.2.1:2003 document contain?
The document contains completion instructions and structured tables for identification data, the global conformance answer, supported services, procedures, timers, protocol parameters, protocol PDUs and error handling. Annex A goes into detailed sub-tables for C-plane and U-plane frames, message support, field-by-field definitions and conditional options. For engineering and testing teams, this is the part that turns a conformance claim into a checkable implementation statement.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 300 476-5 V1.2.1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Protocol Implementation Conformance Statement (PICS) proforma; Part 5: Data Link Control (DLC) layer - Fixed radio Termination (FT)". This standard covers: Version 2 of the PICS for voluntary testing of ETS 300 175. This update corrects errors which were found during the implementation of the first edition of this document (ETS 300 476-1) and alignment with the second edition of ETS 300 175.
Version 2 of the PICS for voluntary testing of ETS 300 175. This update corrects errors which were found during the implementation of the first edition of this document (ETS 300 476-1) and alignment with the second edition of ETS 300 175.
SIST EN 300 476-5 V1.2.1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.070.30 - Digital Enhanced Cordless Telecommunications (DECT). The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 300 476-5 V1.2.1:2003 is associated with the following European legislation: Standardization Mandates: T-292. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
SIST EN 300 476-5 V1.2.1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Digital Enhanced Cordless Telecommunications (DECT); Common Interface (CI); Protocol Implementation Conformance Statement (PICS) proforma; Part 5: Data Link Control (DLC) layer - Fixed radio Termination (FT)33.070.30'(&7Digital Enhanced Cordless Telecommunications (DECT)ICS:Ta slovenski standard je istoveten z:EN 300 476-5 Version 1.2.1SIST EN 300 476-5 V1.2.1:2003en01-december-2003SIST EN 300 476-5 V1.2.1:2003SLOVENSKI
STANDARD
ETSIEN300476-5V1.2.1(2000-11)EuropeanStandard(Telecommunicationsseries)DigitalEnhancedCordlessTelecommunications(DECT);CommonInterface(CI);ProtocolImplementationConformanceStatement(PICS)proforma;Part5:DataLinkControl(DLC)layer-FixedradioTermination(FT)SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)2ReferenceREN/DECT-040106-5Keywordsaccess,DECT,PICS,radio,testingETSI650RoutedesLuciolesF-06921SophiaAntipolisCedex-FRANCETel.:+33492944200Fax:+33493654716SiretN°34862356200017-NAF742CAssociationàbutnonlucratifenregistréeàlaSous-PréfecturedeGrasse(06)N°7803/88ImportantnoticeIndividualcopiesofthepresentdocumentcanbedownloadedfrom:http://www.etsi.orgThepresentdocumentmaybemadeavailableinmorethanoneelectronicversionorinprint.Inanycaseofexistingorperceiveddifferenceincontentsbetweensuchversions,thereferenceversionisthePortableDocumentFormat(PDF).Incaseofdispute,thereferenceshallbetheprintingonETSIprintersofthePDFversionkeptonaspecificnetworkdrivewithinETSISecretariat.Usersofthepresentdocumentshouldbeawarethatthedocumentmaybesubjecttorevisionorchangeofstatus.InformationonthecurrentstatusofthisandotherETSIdocumentsisavailableathttp://www.etsi.org/tb/status/Ifyoufinderrorsinthepresentdocument,sendyourcommentto:editor@etsi.frCopyrightNotificationNopartmaybereproducedexceptasauthorizedbywrittenpermission.Thecopyrightandtheforegoingrestrictionextendtoreproductioninallmedia.©EuropeanTelecommunicationsStandardsInstitute2000.Allrightsreserved.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)3ContentsIntellectualPropertyRights.5Foreword.51Scope.62References.63Definitionsandabbreviations.63.1Definitions.63.2Abbreviations.74ConformancerequirementtothisPICSspecification.7AnnexA(normative):PICSproformaforDECTDLCFT.8A.1IntroductionforcompletingthePICSproforma.8A.1.1Purposesandstructure.8A.1.3GuidancesforcompletingthePICS.10A.2Identificationoftheimplementation.10A.2.1Dateofstatement.10A.2.2ImplementationUnderTest(IUT)identification.10A.2.3SystemUnderTest(SUT)identification.10A.2.4Productsupplier.11A.2.5Clientidentification.11A.2.6Contactperson.11A.3Identificationoftheprotocol.12A.4Globalstatementofconformance.12A.5Capabilities.12A.5.1Majorcapabilities.12A.5.1.1Services.12A.5.1.2Procedures.13A.5.1.2.1Genericsignallingprocedures.13A.5.1.2.2ClassUprocedures.13A.5.1.2.3ClassAprocedures.14A.5.1.2.4ClassBprocedures.14A.5.1.2.5Broadcastprocedures.14A.5.1.2.6LU1procedures.14A.5.1.2.7LU2procedures.15A.5.1.2.8LU3procedures.15A.5.1.2.9LU5protecteddataprocedures.16A.5.1.2.10LU5unprotecteddataprocedures.16A.5.1.2.11LU6procedures.16A.5.1.2.12LU7procedures.16A.5.1.2.13LU8procedures.17A.5.1.2.14LU9procedures.17A.5.1.2.15LU10procedures.18A.5.1.2.16Managementprocedures.18A.5.2Protocolparameters.19A.5.2.1C-planetimers.19A.5.2.2U-planetimers.19A.5.2.3ClassAparameters.19A.5.2.4ClassBparameters.20A.5.2.5LU1parameters.20A.5.2.6LU2parameters.20A.5.2.7LU5parameters.21A.5.2.8LU7parameters.22SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)4A.5.2.9LU8parameters.22A.5.2.10LU9parameters.22A.5.2.11LU10parameters.23A.5.3ProtocolPDUs.23A.5.3.1C-planePDUs.23A.5.3.1.1C-planeframestructure.23A.5.3.1.2C-planemessages.24A.5.3.1.2.1Messagesupport.24A.5.3.1.2.2ClassAI-command.25A.5.3.1.2.3ClassARRcommand/response.27A.5.3.1.2.4ClassBI-command.28A.5.3.1.2.5ClassBRRcommand/response.29A.5.3.1.2.6ClassBRNRcommand/response.30A.5.3.1.2.7ClassBREJcommand/response.31A.5.3.1.2.8ClassBSABMcommand.33A.5.3.1.2.9ClassBDMresponse.34A.5.3.1.2.10ClassBDISCcommand.35A.5.3.1.2.11ClassBUAresponse.36A.5.3.1.2.12ClassUUIcommand.37A.5.3.2U-planePDUs.39A.5.3.2.1FU1framestructure.39A.5.3.2.2FU2framestructure.40A.5.3.2.3FU3aframestructure.41A.5.3.2.4FU3bframestructure.42A.5.3.2.5FU4aframestructure.43A.5.3.2.6FU4bframestructure.44A.5.3.2.7FU5aframestructure.45A.5.3.2.8FU5bframestructure.46A.5.3.2.9FU6aframestructure.47A.5.3.2.10FU6bframestructure.48A.5.3.2.11FU7framestructure.49A.5.3.2.12FU8framestructure.50A.5.3.2.13FU9framestructure.51A.5.3.2.14FU10aframestructure.53A.5.3.2.15FU10bframestructure.54A.5.4Protocolerrorhandling.55A.5.4.1Generalerrorhandling.55A.5.4.2ClassAerrorhandlingandrecovery.56A.5.4.3ClassBerrorhandlingandrecovery.56Bibliography.57History.58SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)5IntellectualPropertyRightsIPRsessentialorpotentiallyessentialtothepresentdocumentmayhavebeendeclaredtoETSI.TheinformationpertainingtotheseessentialIPRs,ifany,ispubliclyavailableforETSImembersandnon-members,andcanbefoundinETSISR000314:"IntellectualPropertyRights(IPRs);Essential,orpotentiallyEssential,IPRsnotifiedtoETSIinrespectofETSIstandards",whichisavailablefromtheETSISecretariat.LatestupdatesareavailableontheETSIWebserver(http://www.etsi.org/ipr).PursuanttotheETSIIPRPolicy,noinvestigation,includingIPRsearches,hasbeencarriedoutbyETSI.NoguaranteecanbegivenastotheexistenceofotherIPRsnotreferencedinETSISR000314(ortheupdatesontheETSIWebserver)whichare,ormaybe,ormaybecome,essentialtothepresentdocument.ForewordThisEuropeanStandard(Telecommunicationsseries)hasbeenproducedbyETSIProjectDigitalEnhancedCordlessTelecommunications(DECT).Thepresentdocumentispart5ofamulti-partENcoveringtheDigitalEnhancedCordlessTelecommunications(DECT);CommonInterface(CI);ProtocolImplementationConformanceStatement(PICS)proforma,asidentifiedbelow:Part1:"Network(NWK)layer-PortableradioTermination(PT)";Part2:"DataLinkControl(DLC)layer-PortableradioTermination(PT)";Part3:"MediumAccessControl(MAC)layer-PortableradioTermination(PT)";Part4:"Network(NWK)layer-FixedradioTermination(FT)";Part5:"DataLinkControl(DLC)layer-FixedradioTermination(FT)";Part6:"MediumAccessControl(MAC)layer-FixedradioTermination(FT)";Part7:"Physicallayer".AnnexAcontainsthePICSproformafortheFTdatalinkcontrollayer.NationaltranspositiondatesDateofadoptionofthisEN:24November2000DateoflatestannouncementofthisEN(doa):28February2001DateoflatestpublicationofnewNationalStandardorendorsementofthisEN(dop/e):31August2001DateofwithdrawalofanyconflictingNationalStandard(dow):31August2001SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)61ScopeThepresentdocumentprovidestheProtocolImplementationConformanceStatement(PICS)proformafortheDigitalEnhancedCordlessTelecommunicationsDataLinkControllayerattheFixedTerminationasdefinedinEN300175-4[2]incompliancewiththerelevantrequirementsandinaccordancewiththerelevantguidancegiveninISO/IEC9646-7[4].ThesupplierofanimplementationwhichisclaimedtoconformtoEN300175-4[2]isrequiredtocompleteacopyofthePICSproformaprovidedintheannexAofthepresentdocument.2ReferencesThefollowingdocumentscontainprovisionswhich,throughreferenceinthistext,constituteprovisionsofthepresentdocument.• Referencesareeitherspecific(identifiedbydateofpublication,editionnumber,versionnumber,etc.)ornon-specific.• Foraspecificreference,subsequentrevisionsdonotapply.• Foranon-specificreference,thelatestversionapplies.• Anon-specificreferencetoanETSshallalsobetakentorefertolaterversionspublishedasanENwiththesamenumber.[1]ETSIEN300175-1:"DigitalEnhancedCordlessTelecommunications(DECT);CommonInterface(CI);Part1:Overview".[2]ETSIEN300175-4:"DigitalEnhancedCordlessTelecommunications(DECT);CommonInterface(CI);Part4:DataLinkControl(DLC)layer".[3]ISO/IEC9646-1(1995):"Informationtechnology-OpenSystemsInterconnection-Conformancetestingmethodologyandframework-Part1:Generalconcepts".[4]ISO/IEC9646-7(1995):"Informationtechnology-OpenSystemsInterconnection-Conformancetestingmethodologyandframework-Part7:ImplementationConformanceStatements".[5]ETSIETS300651:"DigitalEnhancedCordlessTelecommunications(DECT);DataServicesProfile(DSP);Genericdatalinkservice(servicetypeC,class2)".3Definitionsandabbreviations3.1DefinitionsForthepurposesofthepresentdocument,thefollowingtermsanddefinitionsapply:-termsgiveninEN300175-1[1];-termsgiveninISO/IEC9646-1[3]andinISO/IEC9646-7[4].Inparticular,thefollowingtermsgiveninISO/IEC9646-1[3]apply:ImplementationConformanceStatement(ICS):statementmadebythesupplierofanimplementationorsystemclaimedtoconformtoagivenspecification,statingwhichcapabilitieshavebeenimplemented.TheICScantakeseveralforms:protocolICS,profileICS,profilespecificICS,informationobjectICS,etc.ICSproforma:document,intheformofaquestionnaire,whichwhencompletedforanimplementationorsystembecomesanICSSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)7ProtocolICS(PICS):PICSforanimplementationorsystemclaimedtoconformtoagivenprotocolspecification3.2AbbreviationsForthepurposesofthepresentdocument,theabbreviationsgiveninISO/IEC9646-1[3],thedatalinkcontrollayerabbreviationsgiveninEN300175-4[2],andthefollowingapply:ICSImplementationConformanceStatementIUTImplementationUnderTestPICSProtocolImplementationConformanceStatementSUTSystemUnderTest4ConformancerequirementtothisPICSspecificationIfitclaimstoconformtothepresentdocument,theactualPICSproformatobefilledinbyasuppliershallbetechnicallyequivalenttothetextofthePICSproformagiveninannexA,andshallpreservethenumbering/namingandorderingoftheproformaitems.APICSwhichconformstothepresentdocumentshallbeaconformingPICSproformacompletedinaccordancewiththeinstructionsforcompletiongiveninclauseA.1.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)8AnnexA(normative):PICSproformaforDECTDLCFTNotwithstandingtheprovisionsofthecopyrightclauserelatedtothetextofthepresentdocument,ETSIgrantsthatusersofthepresentdocumentmayfreelyreproducethePICSproformainthisannexsothatitcanbeusedforitsintendedpurposesandmayfurtherpublishthecompletedPICS.A.1IntroductionforcompletingthePICSproformaA.1.1PurposesandstructureThepurposeofthisPICSproformaistoprovideamechanismwherebyasupplierofanimplementationofthefixedterminationspecificdatalinkcontrollayerrequirementsofEN300175-4:DECTDatalinkcontrollayermayprovideinformationabouttheimplementationinastandardizedmanner.ThePICSproformaissubdividedintosubclausesforthefollowingcategoriesofinformation:-instructionsforcompletingthePICSproforma;-identificationoftheimplementation;-identificationoftheEN300175-4:DECTDatalinkcontrollayer;-PICSproformatables:-globalstatementofconformance;-functionalgroupsandprocedures;-timersandprotocolparameters;-messages;-informationelements;-protocolerrorhandling.ThePICSproformacontainedinthisannexiscomprisedofinformationintabularforminaccordancewiththeguidelinespresentedinISO/IEC9646-7.ItemcolumnTheitemcolumncontainsanumberwhichidentifiestheiteminthetable.ItemdescriptioncolumnTheitemdescriptioncolumndescribesinfreetexteachrespectiveitem(e.g.parameters,timers,etc.).Itimplicitlymeans"issupportedbytheimplementation?".StatuscolumnThefollowingnotations,definedinISO/IEC9646-7,areusedforthestatuscolumn:morMmandatory-thecapabilityisrequiredtobesupported.oorOoptional-thecapabilitymaybesupportedornot(e.g.thecapabilityisnotallowedbecausetheunderlyingDECTlayers(serviceprovider)cannothandleitortherequirementbelongstoanapplicationi.e.doesnotbelongtothedatalinkcontrollayer)n/aorN/Anotapplicable-inthegivencontext,itisimpossibletousethecapability.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)9xorXprohibited(excluded)-thereisarequirementnottousethiscapabilityinthegivencontext.o.iorO.iqualifiedoptional-formutuallyexclusiveorselectableoptionsfromaset."i"isanintegerwhichidentifiesanuniquegroupofrelatedoptionalitemsandthelogicoftheirselectionwhichisdefinedimmediatelyfollowingthetable.ciorCiconditional-therequirementonthecapability("m","o","x"or"n/a")dependsonthesupportofotheroptionalorconditionalitems."i"isanintegeridentifyingauniqueconditionalstatusexpressionwhichisdefinedimmediatelyfollowingthetable.iorIout-of-scope-thiscapabilityisoutsidethescopeofthegivenspecification,andhenceirrelevantandnotsubjecttoconformancetesting.Thisstatusisinparticularapplicablefordatafieldswhicharereservedforfutureuse.Thestructureofsuchfieldshastobesupported,butthevalueisundefinedandthustobeignored.ReferencecolumnThereferencecolumngivesreferencetoEN300175-4:Datalinkcontrollayer,exceptwhereexplicitlystatedotherwise.SupportcolumnThesupportcolumnshallbefilledinbythesupplieroftheimplementation.Thefollowingcommonnotations,definedinISO/IEC9646-7,areusedforthesupportcolumn:Yorysupportedbytheimplementation;Nornnotsupportedbytheimplementation;N/A,n/aor-noanswerrequired(allowedonlyifthestatusisn/a,directlyorafterevaluationofaconditionalstatus).Ineachcontext,thekindof"non-support"whichisimplementedatthereceivingmaybeadditionallyindicatedsuchas:-Errtheitemistreatedasaprotocolerror;-lgtheitemisreceivedandignored(i.e.processedsyntactically,butnotsemantically);-rjtheitemisreceivedandrejected.NOTE:AsstatedinISO/IEC9646-7,supportforaPDUrequirestheabilitytoparseallvalidparametersofthatPDU.SupportingaPDUwhilehavingnoabilitytoparseavalidparameterisnon-conformant.SupportforaparameteronaPDUmeansthatthesemanticsofthatparameteraresupported.ValuesallowedcolumnThevaluesallowedcolumncontainsthevaluesortherangesofvaluesallowed.Therangeofvalueisdefinedasfollows:[minvalue]to[maxvalue].Alternativevaluesaredefinedasfollows:-[value1],[value2],to[valuen].EXAMPLE:'00110000'Bto'01001011'Bisthevaluerangefrom'00110000'Bto'01001011'B'00110000'B,'01001011'Bthevaluecanbe'00110000'Bor'01001011'B.ValuessupportedcolumnThevaluessupportedcolumnshallbefilledinbythesupplieroftheimplementation.Inthiscolumn,thevaluesortherangesofvaluessupportedbytheimplementationshallbeindicated.PrerequisitelineAprerequisitelinetakestheform:Prerequisite:.AprerequisitelinebeforeaclauseortabletitleindicatesthatthewholeclauseorthewholetableisnotrequiredtobecompletedifthepredicateisFALSE.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)10A.1.3GuidancesforcompletingthePICSThesupplieroftheimplementationshallcompletethePICSproformaineachofthespacesprovidedusingthenotationdescribedinsubclauseA.1.2.Specificinstructionisprovidedinthetextwhichprecedeseachtable.A.2IdentificationoftheimplementationA.2.1DateofstatementIdentificationoftheImplementationUnderTest(IUT)andthesysteminwhichitresides(theSystemUnderTest(SUT))shouldbefilledinsoastoprovideasmuchdetailaspossibleregardingversionnumbersandconfigurationoptions.TableA.1:DateofstatementDateofstatementDayMonthYearA.2.2ImplementationUnderTest(IUT)identificationThesupplieroftheimplementationshallenterinformationnecessarytouniquelyidentifytheIUTinthetablebelow.TableA.2:IUTidentificationIUTidentificationIUTnameIUTversionA.2.3SystemUnderTest(SUT)identificationThesupplieroftheimplementationshallenterinformationnecessarytouniquelyidentifytheSUTinthetablebelow.TableA.3:SUTidentificationIUTidentificationSUTnameInternationalPortableEquipmentIdentity(IPEI):HardwareconfigurationSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)11A.2.4ProductsupplierTableA.4:ProductsupplierProductsupplierNameAddressPhoneNo.FaxNo.E-mailaddressAdditionalinformationA.2.5ClientidentificationTheproductsupplierinformationandclientinformationshouldbothbefillediniftheyaredifferent.TableA.5:ClientClientNameAddressPhoneNo.FaxNo.E-mailaddressAdditionalinformationA.2.6ContactpersonApersonwhocananswerqueriesregardinginformationsuppliedinthePICSshouldbenamedasthecontactperson.TableA.6:ContactpersonContactpersonNameAddressPhoneNo.FaxNo.E-mailaddressAdditionalinformationSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)12A.3IdentificationoftheprotocolTableA.7:IdentificationofprotocolIdentificationofprotocolTitleofspecificationDigitalEnhancedCordlessTelecommunications(DECT);CommonInterface(CI);Part4:DataLinkControl(DLC)layerReferenceno.EN300175-4DateofPublicationA.4GlobalstatementofconformanceAnexplicitanswershallbeentered,ineachofthesupportorsupportedcolumnboxesprovided,usingthenotationdescribedinsubclauseA.1.2.TableA.8:GlobalstatementofconformanceGlobalstatementofconformanceAreallmandatorycapabilitiesimplemented?NOTE:Answering"No"tothisquestionindicatesnon-conformancetothespecification.Non-supportedmandatorycapabilitiesaretobeidentifiedintheICS,withanexplanationofwhytheimplementationisnon-conforming,onpagesattachedtotheICSproforma.A.5CapabilitiesA.5.1MajorcapabilitiesA.5.1.1ServicesTableA.9:DatalinkservicesItemDatalinkservicesRef.StatusSupport1C-planeservices5o.2U-planeservices11o.o.:Itismandatorytosupportatleastoneoftheseoptions.TableA.10:C-planeservicesPrerequisite:A.9/1ItemC-planeservicesRef.StatusSupport1ClassUservice5.1o.102ClassAservice5.1o.103ClassBservice5.1o.104Broadcastservice5.2,9.4o.10o.10:Itismandatorytosupportatleastoneofthisoptions.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)13TableA.11:U-planeservicesPrerequisite:A.9/2ItemU-planeservicesRef.StatusSupport1LU1-TransparentUnprotectedservice(TRUP)11.2o.112LU2-FrameRelayservice(FREL)11.3o.113LU3-FrameSwitchingservice(FSWI)11.4o.114LU4-Forwarderrorcorrectionservice(FEC)11.5c11015LU5-BasicRateAdaptation(BRAT)protectedservice11.6o.116LU5-BasicRateAdaptation(BRAT)unprotectedservice11.6o.117LU6-SecondaryRateAdaptationservice(SRAT)11.7c11028LU7-64kbit/sdatabearerservicewithARQmechanism11.9c11039LU8-64kbit/sdatabearerservicewithoutARQmechanism11.10o.1110LU9-UnprotectedRateAdaptionforVseriesequipment(RAVE)Service11.11o.1111LU10-EnhancedDataService11.12o.1112LU16-Escapefornon-standardfamily(ESC)11.8o.11o.11:Itismandatorytosupportatleastoneofthisoptions.c1101:Thedefinitivespecificationofthisserviceisforfurtherstudy.c1102:IFA.11/6THENoELSEx.c1103:IF64kbit/sdataservicerequiredTHENmELSEn/a.TableA.12:ManagementservicesItemManagementservicesRef.StatusSupport1MACconnectionmanagement10.2c12012DLCC-planemanagement10.3c12023DLCU-planemanagement10.4c12034Connectionhandovermanagement10.5o5Connectioncipheringmanagement10.6oc1201:IFA.9/1ORA.9/2THENmELSEn/a.c1202:IFA.9/1THENmELSEn/a.c1203:IFA.9/2THENmELSEn/a.A.5.1.2ProceduresA.5.1.2.1GenericsignallingproceduresTableA.13:GenericsignallingproceduresPrerequisite:A.10/2ORA.10/3ItemGenericsignallingproceduresRef.StatusSupp.1SegmentationofNWKinformation5.1.1,7.7m2CSchannelfragmentationandrecombination6.1.2,6.1.3,6.1.4,6.1.4.2o.133CFchannelfragmentationandrecombination6.1.2,6.1.3,6.1.4,6.1.4.1o.13o.13:Itismandatorytosupportatleastoneofthisoptions.A.5.1.2.2ClassUproceduresTableA.14:ClassUproceduresPrerequisite:A.10/1ItemClassUproceduresRef.StatusSupport1ClassUlinkestablishment9.3.2m2ClassUinformationtransfer9.3.3m3ClassUlinkrelease9.3.4mSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)14A.5.1.2.3ClassAproceduresTableA.15:ClassAproceduresPrerequisite:A.10/2ItemClassAproceduresRef.StatusSupport1ClassAlinkestablishment9.2.3.1m2ClassAacknowledgedinformationtransfer9.2.3.2,9.2.3.3,9.2.3.4,9.2.3.5,9.2.3.6m3ClassAlinkrelease9.2.3.7m4ClassAlinkre-establishment9.2.3.8o5ClassAconnectionhandover9.2.7.3,9.2.7.3.1oA.5.1.2.4ClassBproceduresTableA.16:ClassBproceduresPrerequisite:A.10/3ItemClassBproceduresRef.StatusSupport1ClassBmultipleframeestablishment9.2.4m2ClassBinformationtransfer9.2.5m3ClassBlinkrelease9.2.6m4ClassBlinksuspensionandresumption9.2.7o5ClassBconnectionhandover9.2.7.3,9.2.7.3.2oA.5.1.2.5BroadcastproceduresTableA.17:BroadcastproceduresPrerequisite:A.10/4ItemBroadcastproceduresRef.StatusSupport1Normaloperation9.4.1m2Expeditedoperation9.4.2oA.5.1.2.6LU1proceduresTableA.18:LU1proceduresPrerequisite:A.11/1ItemLU1proceduresRef.StatusSupport1U-planeClass0/mindelay11.2o.18012U-planeclass011.2o.18013FU1frameoperation12.2mo.1801:Itismandatorytosupportatleastoneoftheseoptions.TableA.19:FU1optionsPrerequisite:A.18/3ItemFU1optionsRef.StatusSupport1FU1bufferingprocedures(FU1frameoperation)12.2.2m2FU1minimumdelay(speech)operation12.2.3m3FU1connectionhandover12.2.4c19014FU1transmissionorder12.2.5mc1901:IFA.15/5ORA.16/5THENmELSEn/a.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)15A.5.1.2.7LU2proceduresTableA.20:LU2proceduresPrerequisite:A.11/2ItemLU2proceduresRef.StatusSupport1Checksumoperation11.3.2m2Segmentation11.3.3m3Datatransmission11.3.4m4FU4bufferingprocedures12.5.2o.205FU5bufferingprocedures12.6.2o.206FU6bufferingprocedures12.7.2o.20o.20:Itismandatorytosupportatleastoneofthisoptions.TableA.21:FU4optionsPrerequisite:A.20/4ItemFU4optionsRef.StatusSupport1FU4connectionhandover12.5.3o2FU4transmissionorder12.5.4mTableA.22:FU5optionsPrerequisite:A.20/5ItemFU5optionsRef.StatusSupport1FU5connectionhandover12.6.3o2FU5transmissionorder12.6.4mTableA.23:FU6optionsPrerequisite:A.20/6ItemFU6optionsRef.StatusSupport1FU6connectionhandover12.7.3o2FU6transmissionorder12.7.4mA.5.1.2.8LU3proceduresTableA.24:LU3proceduresPrerequisite:A.11/3ItemLU3proceduresRef.StatusSupport1EstablishmentofLAP-Umultiframeoperation11.4o.24012MaintenanceofLAP-Umultiframeoperation11.4o.24013ReleaseofLAP-Umultiframeoperations11.4o.2401o.2401:Itismandatorytosupportatleastoneoftheseoptions.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)16A.5.1.2.9LU5protecteddataproceduresTableA.25:LU5protecteddataproceduresPrerequisite:A.11/5ItemLU5protecteddataproceduresRef.StatusSupport1Databufferingandinitialrateadaptation11.6.2.2m2Multi-channelsetmultiplexing11.6.2.3m3SegmentationofMultiplexedDataUnits11.6.2.4m4Framesequencing11.6.2.5m5FU5bufferingprocedures12.6.2m6FU5connectionhandover12.6.3o7FU5transmissionorder12.6.4mA.5.1.2.10LU5unprotecteddataproceduresTableA.26:LU5unprotecteddataproceduresPrerequisite:A.11/6ItemLU5unprotecteddataproceduresRef.StatusSupport1Databufferingandinitialrateadaptation11.6.3.2m2Multi-channelsetmultiplexing11.6.3.3m3SegmentationofMultiplexedDataUnits11.6.3.4m4FU1bufferingprocedure12.2.2m5FU1minimumdelay(speech)operation12.2.3o6FU1connectionhandover12.2.4o7FU1transmissionorder12.2.5mA.5.1.2.11LU6proceduresTableA.27LU6proceduresPrerequisite:A.11/7ItemLU6proceduresRef.StatusSupport1Rateadaptationofasynchronouslowerrates11.7c27012Rateadaptationofsynchronouslowerratestoanintermediaterate11.7c27013Rateadaptationofsynchronousratesof48kbit/sand56kbit/sto64kbit/s11.7c2701c2701:IFA.11/6THENoELSEx.A.5.1.2.12LU7proceduresTableA.28:LU7proceduresPrerequisite:A.11/8ItemLU7proceduresRef.StatusSupport1Establishmentandsynchronizationprocedures11.9.4.3.1m2Activephaseprocedures11.9.4.3.2m3Releaseprocedures11.9.4.3.3m4Exceptionalprocedures11.9.4.4mSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)17TableA.29:LU7establishmentandsynchronizationproceduresPrerequisite:A.28/1ItemLU7establishmentandsynchronizationproceduresRef.StatusSupport1Callestablishmentandsynchronization11.9.4.3.1mTableA.30:LU7activephaseproceduresPrerequisite:A.28/2ItemLU7activephaseproceduresRef.StatusSupport1Transmittingframes11.9.4.3.2.1m2Re-transmittingframes11.9.4.3.2.2m3Receivingframes11.9.4.3.2.3m4Sendingacknowledgements11.9.4.3.2.4m5Receivingacknowledgements11.9.4.3.2.5mTableA.31:LU7exceptionalproceduresPrerequisite:A.28/4ItemLU7exceptionalproceduresRef.StatusSupport1Invalidframecondition11.9.4.4.1m2Establishment11.9.4.4.2m3Transmittingframes11.9.4.4.3m4Receivingframes11.9.4.4.4m5Sendingacknowledgements11.9.4.4.5m6N(R)sequenceerror11.9.4.4.7m7N(O)sequenceerror11.9.4.4.8m8N(S)sequenceerror11.9.4.4.9m9Formaterror11.9.4.4.10m10Abnormalrelease11.9.4.4.11m11Implicitreset11.9.4.4.12mA.5.1.2.13LU8proceduresTableA.32:LU8proceduresPrerequisite:A.11/9ItemLU8proceduresRef.StatusSupport1LU7procedureswithoutARQ11.10mA.5.1.2.14LU9proceduresTableA.33:LU9proceduresPrerequisite:A.11/10ItemLU9proceduresRef.StatusSupport1Alignmentsignalmanagement11.11.2m2V.24signalling11.11.3m3Ratecoding11.11.4m4DECTindependentclocking11.11.5m5Userdatatransfer11.11.6m6FU9bufferingprocedures11.11.1.1.2m7FU9connectionhandover11.11.1.1.3o8FU9transmissionorder11.11.1.1.4mSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)18A.5.1.2.15LU10proceduresTableA.34:LU10proceduresPrerequisite:A.11/11ItemLU10proceduresRef.StatusSupport1Peer-to-peertransmissionofuserdata11.12.3m2SegmentationofMultiplexedDataUnits11.12.2m3ManagementofV(S),V(R),handlingofN(S),N(R)11.12.2m4FU10bufferingprocedures12.11.2m5FU10connectionhandover12.11.3o6FU10transmissionorder12.11.4mA.5.1.2.16ManagementproceduresTableA.35:ManagementproceduresPrerequisite:A.12ItemManagementproceduresRef.StatusSupport1MACconnectionmanagement10.2c35012DLCC-planemanagement10.3c35023DLCU-planemanagement10.4c35034Connectionhandovermanagement10.5c35045Connectioncipheringmanagement10.6c3505c3501:IFA.12/1THENmELSEn/a.c3502:IFA.12/2THENmELSEn/a.c3503:IFA.12/3THENmELSEn/a.c3504:IFA.12/4AND(A.15/5ORA.16/5ORA.0/3ORA.21/1ORA.22/1ORA.23/1ORA.25/6ORA.26/6)THENmELSEx.c3505:IFA.12/5THENmELSEn/a.TableA.36:MACconnectionmanagementproceduresPrerequisite:A.35/1ItemMACconnectionmanagementproceduresRef.StatusSupport1MACconnectionset-up10.2.1m2MACconnectionrelease10.2.2m3MACconnectionmodification10.2.3o4MACconnectionidentification10.2.4m5Selectionoflogicalchannels(CSorCF)10.2.5oTableA.37:DLCC-planemanagementproceduresPrerequisite:A.35/2ItemDLCC-planemanagementproceduresRef.StatusSupport1Provisionoflinksignature10.3.1m2Routeingofconnectionorientedlinks10.3.2c37013Routeingofconnectionlesslinks10.3.3mc3701:IFA.9/1THENmELSEn/a.TableA.38:DLCU-planemanagementproceduresPrerequisite:A.35/3ItemDLCU-planemanagementproceduresRef.StatusSupport1U-planeestablishment10.4.1m2U-planerelease10.4.2m3U-planesuspendandresume10.4.3oSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)19TableA.39:ConnectioncipheringmanagementproceduresPrerequisite:A.35/5ItemConnectioncipheringmanagementproceduresRef.StatusSupport1ProvidingakeytotheMAClayer10.6.1.1m2Startingtheciphering10.6.1.2m3Stoppingtheciphering10.6.1.2o4Connectionhandover10.6.1.3c39015DLC-initiatedciphering10.6.2oc3901:IFA.35/4THENmELSEn/a.A.5.2ProtocolparametersA.5.2.1C-planetimersTableA.40:C-planetimersPrerequisite:A.9/1ItemC-planetimersRef.StatusSupp.ValueAllowedValueSupported1DL.00A.1c40042s2DL.01A.1c40032s3DL.02A.1c40042s4DL.03A.1c40032s5DL.04(CFroutedframes)A.1c40011s6DL.04(CSroutedframes)A.1c40022s7DL.05A.1c400510s8DL.06A.1c40054s9DL.07A.1c40062sc4001:IFA.13/3THENmELSEn/a.c4002:IFA.13/2THENmELSEn/a.c4003:IFA.16/4THENmELSEn/a.c4004:IFA.10/3THENmELSEn/a.c4005:IFA.35/4THENmELSEn/a.c4006:IFA.10/2THENmELSEn/a.A.5.2.2U-planetimersTableA.41:U-planetimersPrerequisite:A.9/2ItemU-planetimersRef.StatusSupp.ValueAllowedValueSupported1DLU.01A.2c41012sc4101:IFA.49/4ORA.49/5ORA.49/6THENmELSEn/a.A.5.2.3ClassAparametersTableA.42:ClassAparametervaluesPrerequisite:A.10/2ItemClassAparameterRef.StatusSupport1Fixedwindowsizeof19.2.3.2,7.5.2.2m2Modulus29.2.3.2,7.5.2.1mSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)20A.5.2.4ClassBparametersTableA.43:ClassBparametervaluesPrerequisite:A.10/3ItemClassBparameterRef.StatusSupport1Fixedwindowsizeof37.5.2.2m2Modulus89.2.4.2,7.5.2.1mA.5.2.5LU1parametersTableA.44:LU1FrametypesPrerequisite:A.11/1ItemFrametypesRef.StatusSupport1FU1framestructure11.2,12.2mTableA.45:LU1ConnectiontypesPrerequisite:A.11/1ItemConnectiontypesRef.StatusSupport1IN/mindelay-Halfslot(10octets)11.2,12.2.1o.452IN/normaldelay-Halfslot(10octets)11.2,12.2.1o.453IN/mindelay-Fullslot(40octets)11.2,12.2.1o.454IN/normaldelay-Fullslot(40octets)11.2,12.2.1o.455IN/mindelay-Doubleslot(100octets)11.2,12.2.1o.456IN/normaldelay-Doubleslot(100octets)11.2,12.2.1o.45o.45:Itismandatorytosupportatleastoneofthisoptions.TableA.46:LU1TransmissionclassesPrerequisite:A.11/1ItemTransmissionclassesRef.StatusSupport1class0.mindelay11.2o.462class011.2o.46o.46:Itismandatorytosupportatleastoneofthisoptions.A.5.2.6LU2parametersTableA.47:LU2FrametypesPrerequisite:A.11/2ItemFrametypeRef.StatusSupport1FU4framestructure11.3.3,12.5.1c47012FU5framestructure11.3.3,12.6.1c47023FU6framestructure11.3.3,12.7.1c4703c4701:IFA.49/2ORA.49/5ORA.49/8THENmELSEn/a.c4702:IFA.49/1ORA.49/4ORA.49/7THENmELSEn/a.c4703:IFA.49/3ORA.49/6ORA.49/9THENmELSEn/a.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)21TableA.48:LU2ConnectiontypesPrerequisite:A.11/2ItemConnectiontypesRef.StatusSupport1IP/error-detect-Halfslot(08octets)11.3,12.5.1,12.6.1,12.7.1o.482IP/error-correct-Halfslot(08octets)11.3,12.5.1,12.6.1,12.7.1o.483IP/error-detect-Fullslot(32octets)11.3,12.5.1,12.6.1,12.7.1o.484IP/error-correct-Fullslot(32octets)11.3,12.5.1,12.6.1,12.7.1o.485IP/error-detect-Doubleslot(80octets)11.3,12.5.1,12.6.1,12.7.1o.486IP/error-correct-Doubleslot(80octets)11.3,12.5.1,12.6.1,12.7.1o.48o.48:Itismandatorytosupportatleastoneofthisoptions.TableA.49:LU2TransmissionclassesPrerequisite:A.11/2ItemTransmissionclassesRef.StatusSupport1class0/bi-orunidirectional11.3.3o.492class0/bidirectional11.3.3o.493class0/unidirectional11.3.3o.494class1/bi-orunidirectional11.3.3o.495class1/bidirectional11.3.3o.496class1/unidirectional11.3.3o.497class2/bi-orunidirectional11.3.3o.498class2/bidirectional11.3.3o.499class2/unidirectional11.3.3o.49o.49:Itismandatorytosupportatleastoneofthisoptions.A.5.2.7LU5parametersTableA.50:LU5FrametypesPrerequisite:A.11/5ORA.11/6ItemFrametypeRef.StatusSupport1FU1framestructure11.6.3.1,12.2c50012FU5framestructure11.6.2.1,12.6c5002c5001:IFA.11/6THENmELSEn/a.c5002:IFA.11/5THENmELSEn/a.TableA.51:LU5ConnectiontypesPrerequisite:A.11/5ORA.11/6ItemConnectiontypesRef.StatusSupport1IP/error-detect-Halfslot(08octets)11.6,12.6.1o.512IP/error-correct-Halfslot(08octets)11.6,12.6.1o.513IP/error-detect-Fullslot(32octets)11.6,12.6.1o.514IP/error-correct-Fullslot(32octets)11.6,12.6.1o.515IP/error-detect-Doubleslot(80octets)11.6,12.6.1o.516IP/error-correct-Doubleslot(80octets)11.6,12.6.1o.51o.51:Itismandatorytosupportatleastoneofthisoptions.TableA.52:LU5TransmissionclassesPrerequisite:A.11/5ORA.11/6ItemTransmissionclassesRef.StatusSupport1class011.6.2c52012class311.6.2c5202c5201:IFA.50/1THENmELSEn/a.c5202:IFA.50/2THENmELSEn/a.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)22A.5.2.8LU7parametersTableA.53:LU7FrametypesPrerequisite:A.11/8ItemFrametypesRef.StatusSupport1FU7framestructure11.9.4.2mTableA.54:LU7ConnectiontypesPrerequisite:A.11/8ItemConnectiontypesRef.StatusSupport1IN/normaldelay-Doubleslot(100octets)11.9.2,11.9.3mA.5.2.9LU8parametersTableA.55:LU8FrametypesPrerequisite:A.11/9ItemFrametypesRef.StatusSupport1FU8framestructure11.10.3mTableA.56:LU8ConnectiontypesPrerequisite:A.11/9ItemConnectiontypesRef.StatusSupport1IN/normaldelay-Doubleslot(100octets)11.10.1mA.5.2.10LU9parametersTableA.57:LU9FrametypesPrerequisite:A.11/10ItemFrametypesRef.StatusSupport1FU9framestructure11.11.1.1.1mTableA.58:LU9ConnectiontypesPrerequisite:A.11/10ItemConnectiontypesRef.StatusSupport1IN/normaldelay-Fullslot(40octets)11.11.1.1.1mTableA.59:LU9TransmissionclassesPrerequisite:A.11/10ItemTransmissionclassesRef.StatusSupport1class011.11.1mSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)23A.5.2.11LU10parametersTableA.60:LU10FrametypesPrerequisite:A.11/11ItemFrametypesRef.StatusSupport1FU10framestructure12.11.1mTableA.61:LU10ConnectiontypesPrerequisite:A.11/11ItemConnectiontypesRef.StatusSupport1IP/error-detect-Halfslot(08octets)12.11.1o.612IP/error-detect-Fullslot(32octets)12.11.1o.613IP/error-detect-Doubleslot(80octets)12.11.1o.61o.61:Itismandatorytosupportatleastoneofthisoptions.TableA.62:LU10TransmissionclassesPrerequisite:A.11/11ItemTransmissionclassesRef.StatusSupport1class2/bi-orunidirectional11.12.2o.622class3/bi-orunidirectional11.12.2o.62o.62:Itismandatorytosupportatleastoneofthisoptions.A.5.3ProtocolPDUsA.5.3.1C-planePDUsA.5.3.1.1C-planeframestructureTableA.63:Framestructures(ReceivingPTtoFT)ItemFrameStructuresRef.StatusSupport1FramestructureofformattypeFA.6.1c63012Broadcastserviceframestructure6.2n/ac6301:IFA.9/1THENmELSEn/a.TableA.64:Framestructures(SendingFTtoPT)ItemFrameStructuresRef.StatusSupport1FramestructureofformattypeFA.6.1c64012Broadcastserviceframestructure6.2c6402c6401:IFA.9/1THENmELSEn/a.c6402:IFA.10/4THENmELSEn/a.SIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)24TableA.65:FrameformattypeFA(ReceivingPTtoFT)Prerequisite:A.63/1ItemFrameelementsRef.StatusSupport1Addressfield6.1m2Controlfield6.1m3Lengthindicatorfield6.1m4Informationfield6.1c65015Fillfield6.1m6Checksumfield6.1mc6501:IFA.68/1ORA.70/1ORA.72/1THENmELSEx.TableA.66:FrameformattypeFA(SendingFTtoPT)Prerequisite:A.64/1ItemFrameelementsRef.StatusSupport1Addressfield6.1m2Controlfield6.1m3Lengthindicatorfield6.1m4Informationfield6.1c66015Fillfield6.1m6Checksumfield6.1mc6601:IFA.69/1ORA.71/1ORA.73/1THENmELSEx.TableA.67:Broadcastserviceframestructure(SendingFTtoPT)Prerequisite:A.64/2ItemFrameelementsRef.StatusSupport1Shortframeformat(3octets)6.2.1o.672Longframeformat(5octets)6.2.1o.67o.67:Itismandatorytosupportatleastoneofthisoptions.A.5.3.1.2C-planemessagesA.5.3.1.2.1MessagesupportTableA.68:ClassAmessagessupport(ReceivingPTtoFT)Prerequisite:A.10/2ItemClassAmessagesRef.StatusSupport1I-command7.11,9.1m2RR-command/response7.11,9.1mTableA.69:ClassAmessagessupport(SendingFTtoPT)Prerequisite:A.10/2ItemClassAmessagesRef.StatusSupport1I-command7.11,9.1m2RR-command/response7.11,9.1mSIST EN 300 476-5 V1.2.1:2003
ETSIETSIEN300476-5V1.2.1(2000-11)25TableA.70:ClassBmessagessupport(ReceivingPTtoFT)Prerequisite:A.10/3ItemClassBmessagesRef.StatusSupport1I-command7.11,9.1m2RR-command/response7.11,9.1m3RNR-command/response7.11,9.1m4REJ-command/response7.11,9.1m5SABM-command7.11,9.1m6DM-response7.11,9.1m7DISC-command7.11,9.1m8UA-response7.11,9.1mTableA.71:ClassBmessagessupport(SendingFTtoPT)Prerequisite:A.10/3ItemClassBmessagesRef.StatusSupport1I-command7.11,9.1m2RR-command/response7.11,9.1m3RNR-command/response7.11,9.1m4REJ-command/response7.11,9.1m5SABM-command7.11,9.1m6DM-response7.11,9.1m7DISC-command7.11,9.1m8UA-response7.11,9.1mTableA.72:ClassUmessagessupport(ReceivingPTtoFT)Prerequisite:A.10/1ItemClassUmessagesRef.StatusSupport1UI-command7.11,9.1mTableA.73:ClassUmessagessupport(SendingFTtoPT)Prerequisite:A.10/1ItemClassUmessagesRef.StatusSupport1UI-command7.11,9.1mA.5.3.1.2.2ClassAI-commandTableA.74:ClassAI-co
...