Abstract

The present document details standardized test procedures for conformance testing of equipment for Point-to-MultiPoint (P-MP) digital radio relay systems applying time division multiple access method (TDMA). Optionally, for certain of the system types defined in the present document, other access methods (e.g. Orthogonal Frequency Division Multiple Access (OFDMA)) may be used in conjunction with TDMA to provide another dimension of multiple access.
Standardized procedures are required in order to fulfil ECC/DEC/(04)04 [1] on the mutual recognition, within CEPT, of the results of conformance tests on equipment carried out in individual CEPT Countries. Furthermore the procedures described in the present document are relevant to be able to fulfil the conformance assessment procedure described in Chapter II of the Directive 1999/5/EC [3] in order to demonstrate the compliance of the DRRS with the relevant Essential Requirements identified in Article 3.2 of the Directive 1999/5/EC [3]. The present document is intended to be applied in conjunction with EN 301 126-2-1 [2] and in conjunction with the individual equipment ENs/ETSs describing TDMA methods and will enable commonality of test results, irrespective of the Supplier or the Notified Body carrying out the test.
The conformance tests described in the present document are those related to radio specific parameters required directly by the relevant radio relay ENs/ETSs. Conformance tests to other boundary EN/ETS (e.g. those for system input/output interfaces and related base band process) are outside the scope of the present document.

Status
Published
Publication Date
28-Feb-2006
Current Stage
6060 - National Implementation/Publication (Adopted Project)
Start Date
01-Mar-2006
Due Date
01-Mar-2006
Completion Date
01-Mar-2006

Buy Documents

Standard

SIST EN 301 126-2-3 V1.2.1:2006

English language (23 pages)
Preview
Preview
e-Library read for
×1 day

SIST EN 301 126-2-3 V1.2.1:2006 is the Slovenian adoption of ETSI EN 301 126-2-3, published by SIST for conformance testing of Point-to-MultiPoint (P-MP) fixed radio systems using time division multiple access (TDMA). It specifies standardized test procedures for radio-specific parameters so that suppliers, test houses and notified bodies can obtain comparable results for CEPT mutual recognition and R&TTE conformity assessment.

What does SIST EN 301 126-2-3 V1.2.1:2006 specify?

SIST EN 301 126-2-3 V1.2.1:2006 specifies standardized conformance test procedures for P-MP digital radio relay equipment that uses TDMA. In some system types, it also allows other access methods such as Orthogonal Frequency Division Multiple Access (OFDMA) together with TDMA.

The scope is limited to radio-specific parameters required directly by the relevant radio relay ENs/ETSs. Tests for other boundary EN/ETS items, such as system input/output interfaces and related base band process, are outside the scope.

The document is organized into four main clauses:

ClauseWhat it covers
1Scope
2References
3Definitions, symbols and abbreviations
4General characteristics, including equipment configuration, transmitter, receiver and system characteristics

Clause 4 is then split into practical test groups for transmitter behavior, receiver behavior, and system-level behavior. That structure matters because users can find the right test method quickly, depending on whether they need to check power, frequency, emission masks, sensitivity or interference performance.

What are the key requirements of SIST EN 301 126-2-3 V1.2.1:2006?

SIST EN 301 126-2-3 V1.2.1:2006 requires tests to be run in a controlled and repeatable way, with the same methods applied to both Central or Remote Stations (CRS(s)) and Terminal Stations (TS(s)) unless the text says otherwise. In practice, this means the same product must be checked under the same conditions by different laboratories if the results are to be comparable.

Test conditions and setup

Clause 4 says that, unless stated otherwise, essential requirements tests are carried out at nominal and extreme power supply and environmental conditions, and at maximum output power. RF power, spectrum and frequency measurements are taken at low, middle and high frequencies within the declared band. For a buyer or compliance engineer, this means a device is not approved on one convenient channel only.

Clause 4.1 describes how the equipment is arranged for testing, including use of splitters, couplers, attenuators and duplexers at defined reference points. The text also notes that duplex systems may need both forward and reverse paths operating, and that traffic can be simulated when several TSs are needed. This matters because the test bench must let the equipment behave normally while still exposing the points where measurements are made.

For multi-carrier TDMA systems, the general remark in clause 4 says each carrier is tested using the procedures for a single-carrier solution unless the relevant EN/ETS says otherwise. For the reader, the practical message is that multi-carrier operation does not remove the need to verify each carrier properly.

Transmitter checks

Clauses 4.2.1 to 4.2.4 cover maximum RF output power, minimum RF output power where applicable, Automatic Transmit Power Control (ATPC) and Remote Transmit Power Control (RTPC). The output power is measured as average power during a burst, using time gating or an equivalent method. The tests are performed at three frequencies across the band. In practice, the laboratory must confirm both the declared power limits and the behavior of any power control feature.

Clause 4.2.5 covers frequency accuracy, and clause 4.2.7 covers remote frequency control where fitted. Clause 4.2.6 covers the RF spectrum mask, and clause 4.2.8 says spectral lines at the symbol rate are checked at the same time when applicable. These tests matter because they show whether the transmitter stays on frequency and fits inside the permitted emission shape across the band.

Clause 4.2.9 covers external spurious emissions. The transmitter is tested at maximum rated output power, and emissions are scanned across the relevant frequency range. The text also gives special handling for equipment with integral antennas and for TDMA/OFDMA TSs, where the manufacturer must identify the worst-case sub-carrier combination. In practice, this is the test that reveals unwanted radiation outside the useful channel.

Receiver and system checks

Clause 4.3.1 checks receiver input level range by recording bit error ratio (BER) at upper and lower input levels. Clause 4.3.2 applies the same spurious emission method used for the transmitter when checking receiver emissions. This tells the user whether the receiver works over its declared input range and whether the receive chain creates unwanted emissions.

Clause 4.4.1 defines dynamic level range by combining the measured receiver input range with the declared and measured ATPC or RTPC control range. Clause 4.4.2 checks BER as a function of receiver signal level (RSL) at at least two BER thresholds. Clause 4.4.3 checks equipment background BER against the limit in the relevant EN/ETS. Together, these tests show how the whole link behaves under realistic operating conditions, not just at one fixed level.

Clause 4.4.4 covers interference sensitivity in both directions, CRS to TS and TS to CRS. It includes co-channel interference sensitivity, adjacent RF-channel interference sensitivity and CW spurious interference. The text allows Method 1 or Method 2, depending on the relevant equipment EN/ETS. For the reader, the practical value is that the equipment is checked against the kinds of interference that actually affect service quality.

What terms does SIST EN 301 126-2-3 V1.2.1:2006 define?

  • Point-to-MultiPoint (P-MP) - A fixed radio access arrangement where a network node serves user terminals in a multi-point configuration.
  • Time Division Multiple Access (TDMA) - An access method where users share the channel by transmitting in time slots.
  • Central or Remote Station (CRS) - A station in the P-MP system that participates in the conformance tests alongside the TS.
  • Terminal Station (TS) - The user-side station whose transmitter and receiver are tested in the P-MP link.
  • Automatic Transmit Power Control (ATPC) - A control function that adjusts transmit power automatically in response to link conditions.
  • Remote Transmit Power Control (RTPC) - A function that lets transmit power be adjusted from a remote control point.
  • Receiver Signal Level (RSL) - The received signal level used to judge BER thresholds and receiver performance.
  • Bit Error Ratio (BER) - The ratio used to assess error performance in receiver and system tests.
  • Carrier to Interferer (C/I) - The ratio used in interference sensitivity tests to compare wanted and unwanted signal power.

Who uses SIST EN 301 126-2-3 V1.2.1:2006?

SIST EN 301 126-2-3 V1.2.1:2006 is used by manufacturers, suppliers, test houses, notified bodies and quality or compliance teams working on fixed radio systems. It is especially relevant when they need conformance test results for P-MP digital radio relay equipment using TDMA.

It is also useful for engineering and regulatory teams that must compare results across suppliers or laboratories, because the document is intended to support common test practice regardless of who performs the test. National regulators and certification bodies can use it when reviewing radio-specific conformance evidence for market access or mutual recognition.

What changed in SIST EN 301 126-2-3 V1.2.1:2006 from the previous edition?

The document history lists V1.1.1, published in November 2000, as the earlier version and V1.2.1 as the later version. The history also records V1.2.1 publication in November 2004.

Which standards are used with SIST EN 301 126-2-3 V1.2.1:2006?

ReferenceWhat it contributes
EN 301 126-2-1Definitions, symbols, abbreviations and general requirements for P-MP equipment; this part is to be used together with it.
EN 60835-1General measurement methods for digital microwave radio transmission systems, used for understanding and supporting the test methods.
ECC/DEC/(04)04The mutual recognition basis within CEPT for conformance test results.
Directive 1999/5/ECThe R&TTE conformity assessment framework that the procedures support.
CEPT/ERC/REC 74-01The reference used for spurious emissions measurements.

The foreword also places this part in the wider EN 301 126 series, alongside parts for point-to-point equipment, other P-MP test methods and antenna standards.

What does the SIST EN 301 126-2-3 V1.2.1:2006 document contain?

The document contains detailed test setups, measurement sequences and acceptance checks for transmitter, receiver and system behavior. Figures show the general system architecture, RF block diagrams and specific benches for power, frequency, spectrum mask, spurious emissions, receiver range, BER and interference tests.

It also includes Table 1 for spectrum analyser settings and notes that explain how to adapt the test to burst duration, multi-carrier operation, integral antennas and synchronized TDMA measurements. For a test laboratory, this is the practical material needed to build the setup, choose the instruments and record comparable results.

Buy Documents

Standard

SIST EN 301 126-2-3 V1.2.1:2006

English language (23 pages)
Preview
Preview
e-Library read for
×1 day

Get Certified

Connect with accredited certification bodies for this standard

ANCE

Mexican certification and testing association.

EMA Mexico Verified

Intertek Slovenia

Intertek testing, inspection, and certification services in Slovenia.

UKAS Slovenia Verified

LNE (Laboratoire National de Métrologie et d'Essais)

French national laboratory for metrology and testing.

COFRAC France Verified

Sponsored listings

Frequently Asked Questions

SIST EN 301 126-2-3 V1.2.1:2006 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Fixed Radio Systems; Conformance testing; Part 2-3: Point-to-Multipoint equipment; Test procedures for TDMA systems". This standard covers: The present document details standardized test procedures for conformance testing of equipment for Point-to-MultiPoint (P-MP) digital radio relay systems applying time division multiple access method (TDMA). Optionally, for certain of the system types defined in the present document, other access methods (e.g. Orthogonal Frequency Division Multiple Access (OFDMA)) may be used in conjunction with TDMA to provide another dimension of multiple access. Standardized procedures are required in order to fulfil ECC/DEC/(04)04 [1] on the mutual recognition, within CEPT, of the results of conformance tests on equipment carried out in individual CEPT Countries. Furthermore the procedures described in the present document are relevant to be able to fulfil the conformance assessment procedure described in Chapter II of the Directive 1999/5/EC [3] in order to demonstrate the compliance of the DRRS with the relevant Essential Requirements identified in Article 3.2 of the Directive 1999/5/EC [3]. The present document is intended to be applied in conjunction with EN 301 126-2-1 [2] and in conjunction with the individual equipment ENs/ETSs describing TDMA methods and will enable commonality of test results, irrespective of the Supplier or the Notified Body carrying out the test. The conformance tests described in the present document are those related to radio specific parameters required directly by the relevant radio relay ENs/ETSs. Conformance tests to other boundary EN/ETS (e.g. those for system input/output interfaces and related base band process) are outside the scope of the present document.

The present document details standardized test procedures for conformance testing of equipment for Point-to-MultiPoint (P-MP) digital radio relay systems applying time division multiple access method (TDMA). Optionally, for certain of the system types defined in the present document, other access methods (e.g. Orthogonal Frequency Division Multiple Access (OFDMA)) may be used in conjunction with TDMA to provide another dimension of multiple access. Standardized procedures are required in order to fulfil ECC/DEC/(04)04 [1] on the mutual recognition, within CEPT, of the results of conformance tests on equipment carried out in individual CEPT Countries. Furthermore the procedures described in the present document are relevant to be able to fulfil the conformance assessment procedure described in Chapter II of the Directive 1999/5/EC [3] in order to demonstrate the compliance of the DRRS with the relevant Essential Requirements identified in Article 3.2 of the Directive 1999/5/EC [3]. The present document is intended to be applied in conjunction with EN 301 126-2-1 [2] and in conjunction with the individual equipment ENs/ETSs describing TDMA methods and will enable commonality of test results, irrespective of the Supplier or the Notified Body carrying out the test. The conformance tests described in the present document are those related to radio specific parameters required directly by the relevant radio relay ENs/ETSs. Conformance tests to other boundary EN/ETS (e.g. those for system input/output interfaces and related base band process) are outside the scope of the present document.

SIST EN 301 126-2-3 V1.2.1:2006 is classified under the following ICS (International Classification for Standards) categories: 33.060.30 - Radio relay and fixed satellite communications systems. The ICS classification helps identify the subject area and facilitates finding related standards.

SIST EN 301 126-2-3 V1.2.1:2006 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.

Standards Content (Sample)

Contents

  • 1 Scope
  • 2 References
  • 7 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 3 Definitions, symbols and abbreviations
  • 3.1 Definitions
  • 3.2 Symbols
  • 3.3 Abbreviations
  • 4 General characteristics
  • 8 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 4.1 Equipment configuration
  • 9 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 10 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 4.2 Transmitter characteristics
  • 11 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 12 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 13 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 14 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 15 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 4.3 Receiver characteristics
  • 16 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 4.4 System Characteristics
  • 17 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 18 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 19 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 20 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 21 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 22 ETSI EN 301 126-2-3 V1.2.1 (2004-11)
  • 23 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

1 Scope

The present document details standardized test procedures for conformance testing of equipment for Point-to-MultiPoint (P-MP) digital radio relay systems applying time division multiple access method (TDMA). Optionally, for certain of the system types defined in the present document, other access methods (e.g. Orthogonal Frequency Division Multiple Access (OFDMA)) may be used in conjunction with TDMA to provide another dimension of multiple access.

Standardized procedures are required in order to fulfil ECC/DEC/(04)04 [1] on the mutual recognition, within CEPT, of the results of conformance tests on equipment carried out in individual CEPT Countries. Furthermore the procedures described in the present document are relevant to be able to fulfil the conformance assessment procedure described in Chapter II of the Directive 1999/5/EC [3] in order to demonstrate the compliance of the DRRS with the relevant Essential Requirements identified in Article 3.2 of the Directive 1999/5/EC [3]. The present document is intended to be applied in conjunction with EN 301 126-2-1 [2] and in conjunction with the individual equipment ENs/ETSs describing TDMA methods and will enable commonality of test results, irrespective of the Supplier or the Notified Body carrying out the test.

The conformance tests described in the present document are those related to radio specific parameters required directly by the relevant radio relay ENs/ETSs. Conformance tests to other boundary EN/ETS (e.g. those for system input/output interfaces and related base band process) are outside the scope of the present document.

2 References

The following documents contain provisions which, through reference in this text, constitute provisions of the present document.

  • References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
  • For a specific reference, subsequent revisions do not apply.
  • For a non-specific reference, the latest version applies.

Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.

[1] ECC/DEC/(04)04: "ECC Decision of 19 March 2004 on the withdrawal of the ERC Decision (97)10 "ERC Decision of 30 June 1997 on the mutual recognition of conformity assessment procedures including marking of radio equipment and radio terminal equipment". [2] ETSI EN 301 126-2-1: "Fixed Radio Systems; Conformance testing; Part 2-1: Point-to-Multipoint equipment; Definitions and general requirements".

[3] Directive 1999/5/EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (R&TTE Directive).

[4] CEPT/ERC/REC 74-01: "Spurious emissions".

[5] CENELEC EN 60835-1: "Methods of measurement for equipment used in digital microwave radio transmission systems - Part 1: Measurements common to terrestrial radio-relay systems and satellite earth stations".

ETSI

SIST EN 301 126-2-3 V1.2.1:2006

7 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

3 Definitions, symbols and abbreviations

3.1 Definitions

For the purposes of the present document, the terms and definitions given in EN 301 126-2-1 [2] apply.

3.2 Symbols

For the purposes of the present document, the symbols given in EN 301 126-2-1 [2] apply.

3.3 Abbreviations

For the purposes of the present document, the abbreviations given in EN 301 126-2-1 [2] apply.

4 General characteristics

Where necessary, for better understanding of the application of test methods, reference is made to EN 60835-1 [5] (Test methods).

General remark:

Where systems transmitting more than one carrier over the same Tx (Multi carrier TDMA system) all carriers being modulated according to the relevant standard, have to be tested applying for each carrier the test procedures defined for a single carrier solution where not otherwise stated in the relevant EN/ETS. ETSI

SIST EN 301 126-2-3 V1.2.1:2006

8 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

4.1 Equipment configuration

T E T S G T E T S G F T E T S CCS CRS G E T T S Network Node G R S CS T E T S Another CRS may be G connected to the same CCS T E G T E directional antenna Baseband interface reference points F/G Omnidirectional or sector antenna

Figure 1: General system architecture

Z E A TRANSMIT B C D MODULATOR TRANSMITTER BRANCHING FEEDER RF FILTER (see note) Z E A RECEIVE B C D BRANCHING FEEDER DEMODULATOR RECEIVER RF FILTER (see note)

NOTE: No filtering included.

Figure 2: RF System Block diagram ETSI

SIST EN 301 126-2-3 V1.2.1:2006

9 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

4.1.1 System configuration

P-MP equipment is designed to operate as an access system connected to a network node (e.g. local switch) and user terminal equipment (figure 1). The individual conformance tests are made in a single link direction (figure 2) but for certain tests, e.g. for equipment to set up signalling, both forward and reverse links have to operate, the minimum equipment arrangement for tests with only one subscriber is shown in figure 3, where the forward and return RF paths are separated by a pair of duplexers and separate attenuators are inserted in each path. In the absence of any more specific instructions from the supplier it is suggested that the links are operated at threshold (RSL) + n dB where n is half of the link dynamic range except when the receiver is being tested. The other receiver(s) should continue to be operated at threshold (RSL) + n dB.

Calibrated splitters or directional couplers will be inserted at points A, B, C and D (figures 3 and 4) as required for the individual tests, either to provide test points or sources of interfering signals. OMC CRS transmit path A B Attenuator Interface Duplexer CRS Duplexer TS unit Attenuator C D TS transmit path Bit Pattern Generators, bit error rate testers, call generators, etc. as required Bit Pattern Generators, bit error rate testers, call generators, etc. as required

NOTE: TDD systems may only require a single path with one attenuator.

Figure 3: Test configuration for a single Terminal Station NOTE 1: Calibrated splitters or directional couplers will be inserted at points A, B, C and D as required for the individual tests, either as test points or as sources of interfering signals. NOTE 2: When measuring the TS transmitter to demonstrate that it meets the emission mask and spurious emissions limits, the splitter network will have only one TS connected and this network may be removed. NOTE 3: The P-MP systems to be tested are duplex systems and features such as time/frequency synchronization and ATPC require both paths to be functioning correctly. To ensure that the results of measurements on either the forward or return paths, e.g. receiver RSL, are not influenced by conditions in the other path it may be necessary to provide lower attenuation, or raise the transmitter power, in this other path. In the absence of any more specific instructions from the supplier it is suggested that this other path is operated at threshold (RSL) + n dB.

All the test procedures, presented in the following clauses, shall apply to both CRS(s) and TS(s). Unless otherwise stated, all Essential Requirements (ER) tests shall be undertaken at the nominal and extremes of power supply and environmental parameters and at maximum output power. RF power, spectrum and frequency measurements shall be undertaken at low, medium and high frequencies within the declared range of frequencies. These RF frequencies may be selected by remote control or otherwise.

ETSI

SIST EN 301 126-2-3 V1.2.1:2006

10 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

Central or remote stations incorporating integral antennas shall be provided with an appropriate coaxial or waveguide transition by the supplier in order to facilitate the measurements described. For tests where the simultaneous use of several TSs is necessary, then an arrangement similar to that shown in figure 4 is required. To enable communication, the traffic load may be simulated and facilities such as remote loop back may be used to route traffic through the system.

This arrangement ensures that the system operates in a normal manner similar to its configuration for measurements such as transmitter mask and RSL.

TS CRS transmit path TS (see note) A B Attenuator Interface CRS Enable unit communications Attenuator C D TS transmit path Bit Pattern Generators, TS (see note) bit error rate testers, call generators etc. as required TS Bit Pattern Generators, bit error rate testers, call generators etc.

as required

NOTE: TDD systems may only require a single path with one attenuator.

Figure 4: Test Configuration for multiple Terminal Stations

4.2 Transmitter characteristics

4.2.1 Maximum RF output power

Objective:

Verify that the highest average RF output power measured during a transmission burst at reference point B'or C' (figure 5) is within the supplier's declared value, plus/minus the EN/ETS tolerance, and does not exceed the EN/ETS maximum value. For the CRS this may be done using a power meter with all time slots transmitting at maximum power. For the TS this may be done by synchronizing the power measurement with the active burst(s) or correcting the power with a correction due to the on/off duty cycle.

Test instruments:

Average Power Meter with a time gating function or an appropriate alternate. ETSI Duplexer Duplexer N way splitter network including attenuator etc. if required for isolation between TSs

SIST EN 301 126-2-3 V1.2.1:2006

11 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

Test Configuration:

Transmit Z E A B(C) Atten / Modulator Transmitter RF filter Power meter coupler (branching)

Figure 5: Test configuration for maximum RF output power Test Procedure:

With the transmitter power level set to maximum, including ATPC/RTPC, etc, the maximum output power of the transmitter at point B (C) during the worst case, as declared by the supplier, of the modulated transmission burst is measured. To make this measurement an average power meter with a time gating function or an appropriate alternate shall be used. All systems should be tested at 3 frequencies: top, middle and bottom frequencies of the available range. A power splitter or coupler may be required if the TS requires an RF link from the CRS before it can operate.

4.2.2 Minimum RF output power (if applicable)

Objective:

Verify that the minimum RF output power measured at reference point B' or C' of equipment which is fitted with a power control facility is within the specified limit of the declared value. Test Instruments:

Average Power Meter with a time gating function or an appropriate alternate. Test Configuration:

As for maximum power test.

Test Procedure:

With the transmitter power level set to minimum the transmitter output at B (C) is to be measured. All systems should be tested at 3 frequencies: top, middle and bottom frequencies of the available range.

4.2.3 Automatic Transmit Power Control (ATPC)

ATPC is an optional feature. However, when fitted and required by the standard, the minimum and maximum output power levels shall be checked. In addition, satisfactory operation of the automatic facility shall be demonstrated. Objective:

When ATPC is implemented, the control loop is to be checked for satisfactory operation i.e.: Tx output power is related to the input level at the far end receiver.

Test Instruments:

As for maximum power test.

Test Configuration:

To be declared by the supplier.

Test Procedure:

Throughout the transmitter's selected power range, the receiver input level is to be maintained within the limits stated in the relevant EN/ETS or in supplier's guaranteed operating criteria. The test is to be repeated to verify that the automatic power control performance, between maximum selected transmitter power and minimum transmitter power meets the EN/ETS or supplier's performance limits.

ETSI

SIST EN 301 126-2-3 V1.2.1:2006

12 ETSI EN 301 126-2-3 V1.2.1 (2004-11)

4.2.4 Remote Transmit Power Control (RTPC)

Where remote transmit power control option is fitted, it may be checked and recorded during the transmitter output power test. The maximum power shall not exceed that applied in clause 4.2.1 as an essential requirement.

4.2.5 Frequency accuracy

Objective:

To verify that the Tx output frequency is within the limits specified in the relevant EN/ETS. NOTE 1: For systems that do not shut down on loss of synchronization, frequency accuracy should also be measured in the non-synchronized condition.

Test Instruments:

either:

1) Frequency Counter capable of measuring modulated signals; 2) Spectrum Analyser with an accurate frequency reference (recommended two orders of magnitude greater than the allowed limit), internal or external.

Test Configuration:

Freq.counter Transmit Atten Z E A B(C) or Spectrum Modulator Transmitter RF filter Analyser.

(branching)

Figure 6: Test configuration for frequency accuracy Test Procedure:

The Tx is to be operated in the normal operating modulated condition and frequency measurements conducted on each of the three selected frequencies (high, medium, low) through the remote frequency control, if fitted. The measured frequency is to be within the supplier's stated operating range. A power splitter or coupler may be required if the TS requires an RF link from the CRS before it can operate.

Using appropriately gated frequency counter or the spectrum analyser, the CW signal or the carrier breakthrough shall be measured.

If adequate measurement stability cannot be achieved by this method, then the supplier shall make available an appropriate method to place the transmitter in a mode that allows the frequency of the carrier or a pair of sidebands to be measured.

NOTE 2: For systems that do not shut down on loss of synchronization, frequency accuracy should also be measured in the non-synchronized condition.

4.2.6 RF spectrum mask

RF spectrum mask measurements are to be conducted at the lowest, mid-band and highest channel of the unit under test. Objective:

To verify that the output spectrum is within the specified limits of the relevant EN/ETS. Test Instruments:

1) Spectrum Analyser; 2) Plotter.

ETSI

...