SIST EN ISO 21415-2:2026
(Main)Wheat and wheat flour - Gluten content - Part 2: Determination of wet gluten and gluten index by mechanical means (ISO 21415-2:2026)
- Abstract
This document specifies a method for determining the content of wet gluten and the gluten index for wheat flours (Triticum aestivum L. and Triticum durum Desf.) by mechanical means.
This document is directly applicable to flours. It is also applicable to common and durum wheat after grinding, if their particular size distribution meets the specification given in Table B.1.
NOTE This document is related to ICC 137/1[7], ICC 155[8] and AACC Method 38-12.02[9].
- Status
- Published
- Public Enquiry End Date
- 29-Sep-2025
- Publication Date
- 06-Jul-2026
- Technical Committee
- KŽP - Agricultural food products
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 11-Jun-2026
- Due Date
- 16-Aug-2026
- Completion Date
- 07-Jul-2026
SIST EN ISO 21415-2:2026 is the CEN adoption of ISO 21415-2:2026 for wheat and wheat flour. It specifies a mechanical method for measuring wet gluten content and gluten index in wheat flour, and it also applies to ground common and durum wheat when the particle size meets Annex B. It is aimed at laboratories and industry users who need comparable results for quality control, because mechanical and manual wet-gluten methods do not generally give the same result.
What does SIST EN ISO 21415-2:2026 specify?
SIST EN ISO 21415-2:2026 specifies how to determine wet gluten and gluten index by mechanical means for wheat flour from Triticum aestivum L. and Triticum durum Desf. It is directly applicable to flour, and it is also applicable to ground wheat when the ground product meets the granulometry requirements in Annex B.
The document is organized into 12 clauses and 4 annexes:
- Clause 4 explains the principle.
- Clause 5 lists reagents.
- Clause 6 lists apparatus.
- Clause 7 addresses sampling.
- Clause 8 covers test sample preparation.
- Clause 9 gives the procedure.
- Clause 10 gives calculations and the record of results.
- Clause 11 covers precision.
- Clause 12 specifies the test report.
| Annex | What it covers |
|---|---|
| Annex A | Illustrations and dimensions for the washing chamber, mill and centrifuge |
| Annex B | Normative preparation of ground wheat and granulometry requirements |
| Annex C | Interlaboratory test results used for precision data |
| Annex D | Proficiency test data for commercial flours and wheats |
What are the key requirements of SIST EN ISO 21415-2:2026?
SIST EN ISO 21415-2:2026 is built around a mechanical wash-and-spin method. In practice, the standard tells the laboratory what to prepare, what equipment to use, how to run the wash, and how to calculate and report the two results.
Use the right material and preparation route. The method applies directly to flour, while ground wheat must first meet the particle-size limits in Annex B. This matters because granularity affects how the paste forms and how the gluten is washed out.
Prepare the reagents at the stated conditions. Clause 5 uses a sodium chloride (NaCl) solution of 20 g/l, made with analytical-grade reagents and water of suitable purity, and the solution is equilibrated to 22 °C ± 2 °C. This matters because temperature and solution strength affect dough formation and washing behavior.
Use the specified mechanical setup. Clause 6 calls for an automatic gluten separation unit, suitable sieves, a centrifuge running at 6 000 ± 5 per minute with 2 000 g radial acceleration, a balance to 0,01 g, and a grinder capable of meeting Annex B. If metal sieves are used, the report must say so.
Make the paste and wash it under controlled conditions. Clause 9 starts with a 10 g test portion. The suggested saline volume is 4,8 ml, but the document allows adjustment between 4,2 ml and 5,2 ml if the paste is too loose or too firm; mixing is set at 20 s and washing at 5 min unless the equipment setting is changed and reported. For flour, the usual wash volume is 250 ml to 280 ml.
Handle ground wheat differently from flour. For ground wheat, washing is interrupted after 2 min and the partially washed gluten and bran particles are transferred to a chamber with the coarser 840 µm sieve. This step matters because the bran has to be retained while the gluten is still washed cleanly.
Measure wet gluten and gluten index separately. For wet gluten content, the washed gluten is centrifuged for 60 s, then weighed. For gluten index, the gluten is transferred intact to the sieve cassette, centrifuged, and the part that passes through the sieve is weighed; the index is the share retained on the sieve relative to total wet gluten.
Take duplicate measurements and use the precision rules. Clause 9 requires two measurements from the same sample, with a new pair of measurements if the difference is above the repeatability limit. Clause 11 then gives repeatability, reproducibility and critical-difference limits for flour and ground wheat, based on interlaboratory and proficiency-test data.
Report the result in the required form. Wet gluten content is expressed as a percentage by mass to one decimal place, and gluten index is reported to the nearest whole number. Clause 12 also requires the sample identification, the standard used, the method used, deviations, unusual features and the test date.
What terms does SIST EN ISO 21415-2:2026 define?
- Wet gluten - A viscoelastic material made mainly of hydrated gliadin and glutenin, obtained by the method in this document or in ISO 21415-1.
- Gluten index - The mass of wet gluten remaining on the sieve after centrifugation, expressed per 100 g of total wet gluten; a higher index indicates stronger gluten.
- Ground wheat - The result of experimental grinding of whole wheat, with the required granulometry given in Table B.1.
- Flour - Finely milled wheat endosperm with a granulometry below 250 µm.
- Repeatability - The closeness of results from the same laboratory, same operator, same equipment and a short time interval.
- Reproducibility - The closeness of results obtained in different laboratories with different operators and equipment.
Who uses SIST EN ISO 21415-2:2026?
SIST EN ISO 21415-2:2026 is used in cereal and cereal-product testing, flour milling, grain processing and quality assurance. Laboratories use it to compare lots, verify product specifications and support routine control of wheat flour and milled wheat.
It is also relevant to buyers and technical managers who need a common method for contract or intake testing. Because the document distinguishes flour from ground wheat and reports both wet gluten and gluten index, it is useful wherever gluten quantity and gluten quality both matter.
What changed in SIST EN ISO 21415-2:2026 from the previous edition?
SIST EN ISO 21415-2:2026 supersedes EN ISO 21415-2:2015 and ISO 21415-2:2015. The foreword states that this third edition is technically revised.
The main change stated in the document is that the fidelity requirements in Clause 10 were updated according to a new ring-test organized by the Academy of National Food and Strategic Reserves Administration of China. Annex C carries the interlaboratory data behind that update.
Which standards are used with SIST EN ISO 21415-2:2026?
SIST EN ISO 21415-2:2026 points readers to related standards and methods that support sampling, comparison and alternative testing.
- ISO 21415-1 - the manual wet-gluten method; the introduction notes that manual and mechanical extraction do not generally give equivalent results.
- ISO 24333 - a sampling method for cereals and cereal products.
- ISO 18390 - a simplified routine sampling method for cereals, pulses and cereal products.
- ISO 5725-1, ISO 5725-2 and ISO 5725-6 - the statistical basis used in Annex C for analyzing repeatability and reproducibility.
- ICC Standard No. 137/1, ICC Standard No. 155 and AACC Method 38-12.02 - related wet-gluten and gluten-index methods cited as references for comparison.
What does the SIST EN ISO 21415-2:2026 document contain?
The document contains the full test method, calculation rules, precision data and reporting requirements for mechanical wet-gluten and gluten-index determination. It includes formulas for wet gluten content and gluten index, plus the associated reporting rules in Clause 10.
It also contains practical support material that readers can use when setting up or checking the method:
- Figures for the Glutomatic-type washing chamber, mill and centrifuge in Annex A.
- Granulometry limits and grinding instructions for ground wheat in Annex B.
- Interlaboratory test results, tables and fitting curves in Annex C.
- Proficiency-test tables and figures for commercial flour and wheat in Annex D.
Relations
- Effective Date
- 01-Jul-2026
Get Certified
Connect with accredited certification bodies for this standard

BSI Group
BSI (British Standards Institution) is the business standards company that helps organizations make excellence a habit.

Bureau Veritas
Bureau Veritas is a world leader in laboratory testing, inspection and certification services.

DNV
DNV is an independent assurance and risk management provider.
Sponsored listings
Frequently Asked Questions
SIST EN ISO 21415-2:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Wheat and wheat flour - Gluten content - Part 2: Determination of wet gluten and gluten index by mechanical means (ISO 21415-2:2026)". This standard covers: This document specifies a method for determining the content of wet gluten and the gluten index for wheat flours (Triticum aestivum L. and Triticum durum Desf.) by mechanical means. This document is directly applicable to flours. It is also applicable to common and durum wheat after grinding, if their particular size distribution meets the specification given in Table B.1. NOTE This document is related to ICC 137/1[7], ICC 155[8] and AACC Method 38-12.02[9].
This document specifies a method for determining the content of wet gluten and the gluten index for wheat flours (Triticum aestivum L. and Triticum durum Desf.) by mechanical means. This document is directly applicable to flours. It is also applicable to common and durum wheat after grinding, if their particular size distribution meets the specification given in Table B.1. NOTE This document is related to ICC 137/1[7], ICC 155[8] and AACC Method 38-12.02[9].
SIST EN ISO 21415-2:2026 is classified under the following ICS (International Classification for Standards) categories: 67.060 - Cereals, pulses and derived products. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN ISO 21415-2:2026 has the following relationships with other standards: It is inter standard links to SIST EN ISO 21415-2:2016. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN ISO 21415-2:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2026
Nadomešča:
SIST EN ISO 21415-2:2016
Pšenica in pšenična moka - Vsebnost glutena - 2. del: Določanje mokrega glutena
in indeksa glutena na mehanski način (ISO 21415-2:2026)
Wheat and wheat flour - Gluten content - Part 2: Determination of wet gluten and gluten
index by mechanical means (ISO 21415-2:2026)
Weizen und Weizenmehl - Glutengehalt - Teil 2: Bestimmung von Feuchtgluten und
Glutenindex durch mechanische Verfahren (ISO 21415-2:2026)
Blé et farines de blé - Teneur en gluten - Partie 2: Détermination du gluten humide et du
gluten index par des moyens mécaniques (ISO 21415-2:2026)
Ta slovenski standard je istoveten z: EN ISO 21415-2:2026
ICS:
67.060 Žita, stročnice in proizvodi iz Cereals, pulses and derived
njih products
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EN ISO 21415-2
EUROPEAN STANDARD
NORME EUROPÉENNE
June 2026
EUROPÄISCHE NORM
ICS 67.060 Supersedes EN ISO 21415-2:2015
English Version
Wheat and wheat flour - Gluten content - Part 2:
Determination of wet gluten and gluten index by
mechanical means (ISO 21415-2:2026)
Blé et farines de blé - Teneur en gluten - Partie 2: Weizen und Weizenmehl - Glutengehalt - Teil 2:
Détermination du gluten humide et du gluten index par Bestimmung von Feuchtgluten und Glutenindex durch
des moyens mécaniques (ISO 21415-2:2026) mechanische Verfahren (ISO 21415-2:2026)
This European Standard was approved by CEN on 29 May 2026.
CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.
CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION
EUROPÄISCHES KOMITEE FÜR NORMUNG
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2026 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN ISO 21415-2:2026 E
worldwide for CEN national Members.
Contents Page
European foreword . 3
European foreword
This document (EN ISO 21415-2:2026) has been prepared by Technical Committee ISO/TC 34 "Food
products" in collaboration with Technical Committee CEN/TC 338 “Cereal and cereal products” the
secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by December 2026, and conflicting national standards
shall be withdrawn at the latest by December 2026.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
This document supersedes EN ISO 21415-2:2015.
Any feedback and questions on this document should be directed to the users’ national standards
body/national committee. A complete listing of these bodies can be found on the CEN website.
According to the CEN-CENELEC Internal Regulations, the national standards organizations of the
following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland,
Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Republic of
North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Türkiye and the
United Kingdom.
Endorsement notice
The text of ISO 21415-2:2026 has been approved by CEN as EN ISO 21415-2:2026 without any
modification.
International
Standard
ISO 21415-2
Third edition
Wheat and wheat flour — Gluten
2026-05
content —
Part 2:
Determination of wet gluten and
gluten index by mechanical means
Blé et farines de blé — Teneur en gluten —
Partie 2: Détermination du gluten humide et du gluten index par
des moyens mécaniques
Reference number
ISO 21415-2:2026(en) © ISO 2026
ISO 21415-2:2026(en)
© ISO 2026
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
ISO 21415-2:2026(en)
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
5 Reagents . 2
6 Apparatus . 2
7 Sampling . 3
8 Preparation of test sample . 3
9 Procedure . 3
9.1 General .3
9.2 Testing .3
9.3 Paste preparation.3
9.4 Paste washing . .4
9.4.1 Washing time .4
9.4.2 Flour .4
9.4.3 Ground wheat .4
9.4.4 Special case .4
9.5 Spinning and weighing the wet gluten .4
9.6 Determining the gluten index .4
9.7 Number of measurements .5
10 Calculations and record of results . 5
11 Precision . 5
11.1 Interlaboratory test . .5
11.2 Repeatability .6
11.3 Reproducibility .6
11.4 Critical difference .7
11.4.1 Comparison of two sets of measurements in the same laboratory .7
11.4.2 Comparison of two sets of measurements in two laboratories .7
12 Test report . 8
Annex A (informative) Washing chamber and mill of the Glutomatic unit and centrifuge. 9
Annex B (normative) Preparation of ground wheat .12
Annex C (informative) Results of interlaboratory test .13
Annex D (informative) Proficiency tests data for commercial flours and wheats .20
Bibliography .29
iii
ISO 21415-2:2026(en)
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO document should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO’s adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 34, Food products, Subcommittee SC 4, Cereals
and pulses, in collaboration with the European Committee for Standardization (CEN) Technical Committee
CEN/TC 338, Cereal and cereal products, in accordance with the Agreement on technical cooperation between
ISO and CEN (Vienna Agreement).
This third edition cancels and replaces the second edition (ISO 21415-2:2015), which has been technically
revised.
The main changes are as follows:
— fidelity requirements (see Clause 10) have been changed in accordance with a new ring-test organized
by the Academy of National Food and Strategic Reserves Administration of China (see Annex C).
A list of all parts in the ISO 21415 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.
iv
ISO 21415-2:2026(en)
Introduction
[5]
The alternative techniques specified in this document and in ISO 21415-1 for isolation of wet gluten (i.e.
manual extraction and mechanical extraction) do not generally yield equivalent results. The reason for this
is that for full development of the gluten structure the dough needs to be allowed to rest. Hence, the result
obtained by manual extraction is usually greater than that obtained by mechanical extraction, especially
in the case of wheat with high gluten content. Therefore, the test report should always state the technique
used.
v
International Standard ISO 21415-2:2026(en)
Wheat and wheat flour — Gluten content —
Part 2:
Determination of wet gluten and gluten index by mechanical
means
1 Scope
This document specifies a method for determining the content of wet gluten and the gluten index for wheat
flours (Triticum aestivum L. and Triticum durum Desf.) by mechanical means.
This document is directly applicable to flours. It is also applicable to common and durum wheat after
grinding, if their particular size distribution meets the specification given in Table B.1.
[7] [8] [9]
NOTE This document is related to ICC 137/1 , ICC 155 and AACC Method 38-12.02 .
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
ISO and IEC maintain terminology databases for use in standardization at the following addresses:
— ISO Online browsing platform: available at https:// www .iso .org/ obp
— IEC Electropedia: available at https:// www .electropedia .org/
3.1
wet gluten
viscoelastic substance consisting mainly of two protein fractions (gliadin and glutenin) in hydrated form
[5]
Note 1 to entry: Wet gluten is obtained in the way indicated in this document or in ISO 21415-1 .
3.2
gluten index
mass of wet gluten (3.1) remaining on the sieve after centrifugation per 100 g of total wet gluten
Note 1 to entry: The higher the index, the stronger the gluten is.
3.3
ground wheat
result of experimental grinding of whole wheat
Note 1 to entry: The required granulometry is cited in Table B.1.
3.4
flour
finely milled wheat endosperm with a granulometry of less than 250 µm
ISO 21415-2:2026(en)
4 Principle
Preparation of a paste from a sample of flour or of ground wheat and a sodium chloride solution in the
equipment’s chamber. Separation of the wet gluten by washing this paste with a sodium chloride solution,
followed by removal of excess washing solution by centrifugation and weighing the residue. The gluten index
is obtained after centrifuging to force the wet gluten through a special sieve. The percentage of wet gluten
remaining on the sieve after centrifuging is defined as the gluten index.
5 Reagents
Use only reagents of recognized analytical grade, unless otherwise specified and distilled or demineralized
water, or water of equivalent purity.
5.1 Sodium chloride solution, 20 g/l.
Dissolve 200 g of sodium chloride (NaCl) in water, then dilute to 10 l. The temperature of the solution shall
be equilibrated to 22 °C ± 2 °C.
6 Apparatus
The usual laboratory apparatus and, in particular, the following items shall be used.
1)
6.1 Automatic gluten separation unit , (single or double) consisting of a washing/mixing chamber,
mill(s) (see Figures A.1 and A.2) and an electronically controlled distribution device for extracting the
gluten.
6.1.1 Mixing/washing chamber(s), fitted with replaceable chrome-plated sieve support(s) with polyester
sieves with an 88 µm mesh gap and polyamide sieves with an 840 µm mesh gap.
The distance between the mixing hook and the chrome-plated sieve support should be 0,7 mm ± 0,05 mm.
This value should be checked with the calibrated thickness shims supplied.
6.1.2 10 l plastic drum, to contain the sodium chloride solution (5.1) connected to the equipment by a
plastic tube.
6.1.3 Distribution system, consisting of a peristaltic pump allowing the sodium chloride solution (5.1)
used for washing the gluten to be delivered at a constant rate of between 50 ml/min and 56 ml/min.
For a detailed description of the unit and for detailed operating instructions, users of this document should
consult the leaflet of the maker of the equipment used.
6.2 Dispenser, for the sodium chloride solution, permitting delivery of 4,2 ml to 5,2 ml. The most used
volume is 4,8 ml and therefore the setting of the equipment shall be able to distribute this volume.
6.3 Centrifuge, capable of maintaining a rotational frequency of 6 000 ± 5 per minute and producing a
radial acceleration of 2 000g, fitted with two perforated plates with holes of diameter 600 µm or two sieve
cassettes with a 22 mm in diameter grid containing 600 µm holes, to determine the gluten index (see
Figures A.3 and A.4).
6.4 Balance, capable of weighing to the nearest 0,01 g.
6.5 Stainless steel spatula.
1) The Glutomatic System made by Perten Instruments AB (Sweden) is the mechanical device most widely used at
present for this purpose. This information is given for the convenience of users of this document and does not constitute
an endorsement by ISO of this product. Equivalent products may be used if they can be shown to lead to the same results.
ISO 21415-2:2026(en)
6.6 Beakers, with 500 ml capacity (to catch the rinsing water).
6.7 Stainless steel or plastic grippers.
6.8 Laboratory grinder, capable of producing a ground product with a granulometry meeting the
requirements of Table B.1.
7 Sampling
It is important for the laboratory to receive a truly representative sample which has not been damaged or
altered during transport or storage.
The method specified in this document does not cover sampling. A suitable sampling method is given in
[6] [4]
ISO 24333 or ISO 18390 .
8 Preparation of test sample
Homogenize the samples. Before measuring the gluten content, grind the wheat grains with a laboratory
grinder (6.8), as indicated in Annex B. Special precautions should be taken during grinding and storing to
prevent any alteration to the moisture content of samples.
9 Procedure
9.1 General
Automatic equipment (6.1) carries out the operations of preparation and washing of the dough continuously.
Follow the instructions supplied by the manufacturer of the equipment used.
Sample and sodium chloride solution shall be equilibrated at temperature of 22 °C ± 2 °C.
9.2 Testing
Weigh 10 g of the sample to within 0,01 g for testing and transfer to the unit’s washing/mixing chamber
(6.1.1). Ensure that the washing chamber is fitted with a suitable sieve, which has been previously cleaned
and moistened.
When testing flour samples, one or more fine polyester sieve(s) (88 µm aperture) is/are used. When testing
ground wheat, chrome-plated sieve supports fitted with a slotted ring are also required with polyamide
sieves with a mesh gap of 840 µm. In that case, the test starts with the fine sieve and in addition a coarse
sieve is used for the second step in the method.
The gluten index is generally measured using only 88 µm polyester sieves and 840 µm polyamide sieves for
the preparation of the wet gluten. If metal sieves are used, this shall be clearly noted in the test report.
9.3 Paste preparation
As a starting suggestion, add 4,8 ml of sodium chloride solution (5.1) to the test sample with the dispenser
(6.2). Aim the flow of saline solution at the chamber wall so that it does not go through the sieve. Gently
shake the washing chamber to ensure that the saline solution is uniformly distributed over the flour.
It can be necessary to adjust the amount of saline solution used for samples with very high or very low gluten
content. If forming a consistent paste turns out to be difficult (the chamber is flooded during washing), the
amount of saline solution added should be reduced (minimum of 4,2 ml). If very hard firm gluten forms
during mixing, the amount of solution should be increased to 5,2 ml.
ISO 21415-2:2026(en)
The mixing time is set by the manufacturer at 20 s, but this may be adjusted by the user, if necessary. If so,
the modified mixing time shall be reported when presenting the results in the test report (see Clause 12).
Contact the manufacturer to obtain information on adjusting the regulator.
9.4 Paste washing
9.4.1 Washing time
The washing time is set by the manufacturer to 5 min.
If the washing time is modified from the original 5 min, the modified washing time shall be reported when
presenting the results in the test report (see Clause 12).
9.4.2 Flour
A volume of 250 ml to 280 ml of sodium chloride solution is usually required for washing. The solution is
delivered automatically by the equipment at a constant pre-set rate of between 50 ml/min and 56 ml/min
(depending on the equipment).
9.4.3 Ground wheat
After 2 min of washing, stop the equipment, remove the washing chamber with the partially washed gluten
and transfer all the content, including bran particles, to another washing chamber containing a large-grade
sieve (840 µm). This can be done by placing the washing chamber beneath a gentle stream of cold water
(turning one sieve round to face the other and positioning the finer sieve on top).
Place the washing chamber with the coarser sieve containing the transferred lump of gluten in the working
position and continue washing until the washing sequence ends.
9.4.4 Special case
If the automatic washing process does not wash the paste sufficiently, and if the equipment allows it, preset
the dough washing time (9.3) at a higher value or adjust the distribution system flow rate (6.1.3).
9.5 Spinning and weighing the wet gluten
If the gluten index has to be determined, this operation is not needed, so go directly to 9.6.
When washing is complete, remove the wet gluten from the washing chamber using the grippers (6.7). Check
that no gluten remains inside the washing chamber.
Divide the gluten into two equal lumps and place them on the perforated plates of the centrifuge (6.3),
pressing down on them lightly.
Operate the centrifuge to remove the excess solution from the gluten (the pre-set time is 60 s). Remove the
gluten piece with the metal grippers (6.7) and weigh it all (m ) immediately to within 0,01 g (6.4).
There is no need to divide the gluten if a stabilizer is used inside the centrifuge.
If a double unit is used, two lumps of gluten will be pr
...