Furniture - Bunk beds and high beds for non-domestic use - Part 2: Test methods

This part of EN 13453 specifies tests consisting of the application to various parts of the item, of loads or forces simulating normal functional use, as well as misuse that can reasonably be expected to occur.
The tests are designed to evaluate properties without regard to materials, design/construction or manufacturing processes.

Büromöbel - Büroschränke - Teil 1: Maße

Dieser Teil des prEN XYZ legt Prüfverfahren zur Beurteilung der Sicherheit von Etagenbetten im Objektbereich fest.

Ameublement - Lits superposés et lits surélevés a usage non-domestique - Partie 2 : Méthodes d'essais

La présente partie de l'EN 13453 spécifie des méthodes d'essais pour s'assurer de la sécurité, de la solidité et de la durabilité des lits superposés et des lits surélevés a usage non domestique.
Les exigences de sécurité sont données dans l'EN 13453-1 [1].

Pohištvo – Pogradi in visoke postelje, ki niso za domačo uporabo - 2. del: Preskusne metode

General Information

Status
Withdrawn
Publication Date
30-Nov-2004
Withdrawal Date
07-Oct-2012
Technical Committee
Current Stage
9900 - Withdrawal (Adopted Project)
Start Date
24-Sep-2012
Due Date
17-Oct-2012
Completion Date
08-Oct-2012

Relations

Buy Standard

Standard
EN 13453-2:2004
English language
16 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.Büromöbel - Büroschränke - Teil 1: MaßeAmeublement - Lits superposés et lits surélevés a usage non-domestique - Partie 2 : Méthodes d'essaisFurniture - Bunk beds and high beds for non-domestic use - Part 2: Test methods97.140PohištvoFurnitureICS:Ta slovenski standard je istoveten z:EN 13453-2:2004SIST EN 13453-2:2004en,fr,de01-december-2004SIST EN 13453-2:2004SLOVENSKI
STANDARD



SIST EN 13453-2:2004



EUROPEAN STANDARDNORME EUROPÉENNEEUROPÄISCHE NORMEN 13453-2June 2004ICS 97.140English versionFurniture - Bunk beds and high beds for non-domestic use - Part2: Test methodsMeubles - Lits superposés et lits en hauteur pour usagenon-domestique - Partie 2: Méthodes d'essaisMöbel - Etagenbetten und Hochbetten für denObjektbereich - Teil 2: PrüfverfahrenThis European Standard was approved by CEN on 8 April 2004.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMITÉ EUROPÉEN DE NORMALISATIONEUROPÄISCHES KOMITEE FÜR NORMUNGManagement Centre: rue de Stassart, 36
B-1050 Brussels© 2004 CENAll rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 13453-2:2004: ESIST EN 13453-2:2004



EN 13453-2:2004 (E) 2 Contents page Foreword.3 Introduction.4 1 Scope.5 2 Normative references.5 3 Test conditions.5 3.1 General.5 3.2 Preliminary preparation.5 3.3 Application of forces.6 3.4 Tolerances.6 4 Test equipment and apparatus.6 4.1 General.6 4.2 Bed base impacter (see Figure 1).6 4.3 Loading pad.7 4.4 50 mm diameter loading pad.7 4.5 Test mattress.7 4.6 Test mass.8 4.7 Stops.8 4.8 Floor surface.8 5 Test procedures.8 5.1 Assembly and inspection before test.8 5.2 Inspection of workmanship.9 5.3 Strength and durability tests.9 5.3.1 General.9 5.3.2 Impact of bed base.9 5.3.3 Upwards and downwards static loads on bed base.10 5.3.4 Durability of bed base.11 5.3.5 Fastening of upper bed to lower bed.11 5.3.6 Durability of frame.11 5.3.7 Static load of safety barrier.11 5.3.8 Attachment and deflection of ladder.13 5.3.9 Fatigue of ladder treads.13 5.3.10 Tread impact test.13 5.4 Stability test.14 6 Test report.15 Bibliography.16
SIST EN 13453-2:2004



EN 13453-2:2004 (E) 3 Foreword This document (EN 13453-2:2004) has been prepared by Technical Committee CEN/TC 207 “Furniture”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2004, and conflicting national standards shall be withdrawn at the latest by December 2004. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard : Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. SIST EN 13453-2:2004



EN 13453-2:2004 (E) 4
Introduction This part of EN 13453 specifies tests consisting of the application to various parts of the item, of loads or forces simulating normal functional use, as well as misuse that can reasonably be expected to occur. The tests are designed to evaluate properties without regard to materials, design/construction or manufacturing processes. SIST EN 13453-2:2004



EN 13453-2:2004 (E) 5
1 Scope This part of EN 13453 specifies test methods that assess the safety, strength and durability of bunk beds and high beds for non domestic use. The corresponding safety requirements are given in EN 13453-1.[1] 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). EN 747-1, Furniture - Bunk beds for domestic use - Part 1 : Safety requirements. EN ISO 2439:2000, Flexible cellular polymeric materials - Determination of hardness (indentation technique) (ISO 2439:1997) 3 Test conditions 3.1 General The tests are designed to be applied to a bunk bed or high bed that is fully assembled and ready for use. The test results are only valid for the article tested. When the test results are intended to be applied to other similar articles, the test specimen shall be representative of the production model. In the case of designs not catered for in the test procedures, the test shall be carried out as far as possible as described, and a list made of the deviations from the test procedure. 3.2 Preliminary preparation Before any of the test described in this part of EN 13453 are commenced, the bed shall be old enough to ensure that it has developed its full strength. At least four weeks in normal indoor conditions shall have elapsed between manufacture and testing in the case of glued joints in timber and the like. The bed shall be tested as delivered. If a knock-down type it shall be assembled according to instructions supplied with the bed. If the bed can be assembled or combined in different ways, the most adverse combination shall be used for each test. In the case of bunk beds intended to be fastened together in pairs or attached to the structure of a building, they shall be tested as a single free standing bed unless the instructions specifically require attachment to another bunk bed or the building structure. Knock-down fittings shall be tightened before testing. Further tightening shall not take place unless specif
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.