SIST ETS 300 423 E1:2003
(Main)Satellite Earth Stations and Systems (SES); Land Mobile Earth Stations (LMES) operating in the 1,5 / 1,6 GHz bands providing voice and/or data communications
- Abstract
To provide specifications for the standardisation of transmit/receive mobile earth stations in order to ensure general safety and to limit interference to other radio communication services
- Status
- Published
- Publication Date
- 30-Nov-2003
- Withdrawal Date
- 30-Sep-2003
- Technical Committee
- RES - Radio equipment and systems
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
SIST ETS 300 423 E1:2003 is the Slovenian adoption of ETS 300 423, a European Telecommunication Standard from ETSI for Land Mobile Earth Stations (LMES) that use geostationary satellites in the 1,5 / 1,6 GHz bands. It specifies safety, radio-frequency emission limits, and control and monitoring functions for transmit/receive mobile earth stations that provide voice and/or data communications.
What does SIST ETS 300 423 E1:2003 specify?
SIST ETS 300 423 E1:2003 sets the characteristics of Mobile Earth Stations (MESs) used in Land Mobile Satellite Service (LMSS) networks, with a focus on general safety and interference control. The standard covers vehicle-mounted or portable equipment and includes requirements that are mandatory throughout the document, plus some clauses that apply only if the manufacturer chooses to claim them.
The document is organized into scope, normative references, definitions and abbreviations, test report content, safety, radio frequency requirements, MES Control and Monitoring Functions (CMFs), initial burst transmission, optional safety and robustness clauses, and Network Control Facilities (NCFs) guidance. It is supported by four normative annexes that define environmental conditions and the test procedures for unwanted emissions and EIRP density.
| Annex | What it covers |
|---|---|
| Annex A | Environmental and test conditions |
| Annex B | Out-of-band unwanted emissions above 960 MHz - test procedure |
| Annex C | In-band unwanted emissions - test procedure |
| Annex D | EIRP density - test procedure |
What are the key requirements of SIST ETS 300 423 E1:2003?
SIST ETS 300 423 E1:2003 combines safety rules, emission limits, and control logic so an MES does not create avoidable interference and can shut down safely when faults occur. In practice, this means the manufacturer must define the operating bandwidth, document the test conditions, and prove the terminal can limit transmissions when needed.
Safety and warnings
- Mechanical construction for Installable Equipment (IE) and Portable Equipment (PE) follows IEC 215, with verification by documentary evidence and visual inspection. This matters because the equipment must remain safe in normal handling and installation.
- Electrical safety follows IEC 215 paragraphs on power voltages and shock protection. This matters because the terminal must not expose users or installers to dangerous voltages.
- Radio frequency radiation protection requires warning labels that show the closest safe approach distance when power density could exceed 8 W/m2 averaged over 6 minutes. For vehicle-mounted equipment, labels must also guide the user near the normal operating position and around exposed radiating parts.
RF emissions
- Unwanted emissions outside the transmit bands must meet CISPR 22 class B requirements below 960 MHz and specific EIRP limits above 960 MHz. This matters because the MES must not disturb nearby radio or electronic systems.
- Unwanted emissions within the transmit bands are limited in 3 kHz bands outside the nominated bandwidth, with different limits for carrier on and carrier off. The test can be done on the full system or by direct measurement at the antenna feed plus antenna gain calculation.
- EIRP density in the nominated bandwidth is limited off the antenna main beam axis, with limits tied to the angle from the beam and to the declared geostationary orbital arc. This protects other satellite systems using the same band.
Control, monitoring, and robustness
- Electro-Magnetic (EM) immunity requires the MES to keep its CMFs working under defined field strengths up to 2 GHz, with an additional 2 GHz to 3 GHz clause available if the manufacturer applies it. In practice, the terminal should still control transmission even in a noisy electromagnetic environment.
- CMFs must include processor monitoring, transmit frequency generation monitoring, controlled power-on/reset behavior, network authorization, unique terminal identification in non-volatile memory, and response to enable/disable commands from the NCF. These functions prevent uncontrolled transmissions.
- Initial burst transmission is limited for systems that do not inhibit it after reset or power-on, and optional clauses cover hazardous fuels or gases, shock and vibration, and vehicle attachment of Externally Mounted Equipment (EME).
What terms does SIST ETS 300 423 E1:2003 define?
- nominated bandwidth - the bandwidth declared by the manufacturer for the MES transmission, wide enough to include the transmit carrier stability and used as the reference for unwanted-emission limits.
- unwanted emissions - emissions outside the nominated bandwidth.
- Installable Equipment (IE) - equipment intended to be installed in a vehicle, made up of one or more interconnected modules.
- Portable Equipment (PE) - self-contained equipment intended to be portable and normally consisting of a single module.
- Externally Mounted Equipment (EME) - the module or modules the manufacturer identifies as mounted outside the vehicle.
- Control and Monitoring Function (CMF) - a function used to monitor the MES and suppress transmissions when faults or control conditions require it.
- Network Control Facilities (NCFs) - the network-side facilities that send control messages to the MES.
Who uses SIST ETS 300 423 E1:2003?
SIST ETS 300 423 E1:2003 is used by MES manufacturers, satellite terminal designers, compliance laboratories, and test houses that measure emissions and verify safety behavior. It also matters to quality managers and buyers who need to confirm that a vehicle-mounted or portable satellite terminal will fit network control, interference, and safety expectations.
Network operators and system providers use it when defining control channels, authorization behavior, and terminal identification functions. Vehicle integrators use it when installing EME and checking warning labels, attachment methods, and operating positions.
What changed in SIST ETS 300 423 E1:2003 from the previous edition?
SIST ETS 300 423 E1:2003 is identical to ETS 300 423 E1.
Which standards are used with SIST ETS 300 423 E1:2003?
- IEC 215 - provides the safety requirements used for mechanical construction and electrical safety.
- CISPR 22 - provides the class B limits and methods used for unwanted emissions below 960 MHz.
- IEC 510-2-1 - provides measurement methods for satellite earth station subsystems and antenna gain pattern measurements.
- prETS 300 424 - provides the companion requirements for Network Control Facilities (NCFs) for LMES networks.
- IEC 801-3 - provides the EMC test method used for electromagnetic immunity.
- CISPR 16 - provides specifications for radio-interference measuring apparatus and methods.
What does the SIST ETS 300 423 E1:2003 document contain?
The document contains emission limit tables, warning-label requirements, and test-report content for the declared nominated bandwidth, measured results, and operating conditions. It also includes detailed test procedures in Annexes B, C, and D for measuring out-of-band emissions, in-band emissions, and EIRP density.
Annex A gives environmental and test conditions such as wind loading, vibration, shock, acceleration, and rate of turn. The annexes describe the equipment setup, the use of Special Test Equipment (STE), antenna positioning, sweep/store spectrum analysis, and the direct-coupling alternative at the antenna feed.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST ETS 300 423 E1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Satellite Earth Stations and Systems (SES); Land Mobile Earth Stations (LMES) operating in the 1,5 / 1,6 GHz bands providing voice and/or data communications". This standard covers: To provide specifications for the standardisation of transmit/receive mobile earth stations in order to ensure general safety and to limit interference to other radio communication services
To provide specifications for the standardisation of transmit/receive mobile earth stations in order to ensure general safety and to limit interference to other radio communication services
SIST ETS 300 423 E1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.060.30 - Radio relay and fixed satellite communications systems. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST ETS 300 423 E1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Definitions and abbreviations
- 3.1 Definitions
- 3.2 Abbreviations
- 4 Test report
- 5 Safety
- 5.1 Mechanical construction
- 5.2 Electrical safety, power voltages
- 5.3 Radio frequency radiation protection
- 6 Radio Frequency (RF)
- 6.1 Unwanted emission outside the bands 1 631,5 to 1 634,5 MHz and 1 656,5 to 1 660,5 MHz
- 6.2 Maximum unwanted emission within the 1 631,5 to 1 634,5 MHz and 1 656,5 to
- 6.3 Maximum EIRP emission density in the nominated bandwidth
- 6.4 Electro-Magnetic (EM) immunity
- 6.5 Protection of the radio astronomy service from emissions produced by the MES
- 6.6 Protection of electronic equipment from excessive EM fields produced by the MES
- 7 MES Control and Monitoring Functions (CMFs)
- 7.1 Monitoring functions
- 7.2 Power on/reset
- 7.3 Network control reception and authorisation
- 8 Initial burst transmission
- 9 Electrical safety while loading and unloading hazardous fuels or gases
- 10 EM immunity between 2 GHz and 3 GHz
- 11 Compliance with RF specifications under conditions of shock and vibration
- 12 Method of attachment of the Externally Mounted Equipment (EME) to a
- 13 Network Control Facilities (NCFs) for MES networks
- Annex A (normative): Environmental and test conditions
- Annex B (normative): Out-of-band unwanted emissions above 960 MHz - test
- Annex C (normative): In-band unwanted emissions - test procedure
- Annex D (normative): EIRP density - test procedure
1 Scope
This European Telecommunication Standard (ETS) provides specifications for the standardisation of the characteristics of Mobile Earth Stations (MESs) using geostationary satellites with both transmit and receive capabilities in order to ensure general safety and to limit interference to radiocommunication services.
The geostationary satellite networks referred to in this ETS operate under the Land Mobile Satellite Service (LMSS). The MESs operate as a part of a satellite network providing voice and/or data communications.
The frequency bands under which the MESs operate should be within the following bands:
LMSS MESs transmit 1 631,5 - 1 634,5 MHz 1 656,5 - 1 660,5 MHz MESs receive 1 530 - 1 533 MHz 1 555 - 1 559 MHz These MESs generally have the following characteristics:
- the MESs could be either vehicle mounted or portable equipment;
- the MES could consist of a number of modules including suitable interfaces to the user. The main specifications are contained in three categories related to:
- safety: to protect personnel, public and goods from unsafe operating conditions or equipment;
- unwanted emissions: to protect terrestrial and satellite radio services from harmful interference;
- MES control and monitoring: to specify a minimum set of Control and Monitoring Functions (CMFs) to be implemented on each MES in order to minimise the probability that they originate unwanted transmissions that may give rise to harmful interference to other systems. This ETS deals with two types of specification:
- specifications defined in order to protect other users of the frequency spectrum from unacceptable interference. In addition, these specifications are specified for the purposes of general safety;
- specifications related to matters of general safety, minimisation of interference to other users of the radio spectrum and for the provision of protection of the MESs against electromagnetic interference from other systems. These specifications apply if required by the manufacturer.
2 Normative references
This ETS incorporates, by dated or undated references, provisions from other publications. These normative references are cited at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this ETS only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.
[1] IEC 215 (1987): "Safety requirements for radio transmitting equipment". [2] CISPR 22 (1993): "Limits and methods of measurement of radio disturbance characteristics of information technology equipment".
[3] IEC 510-2-1 (1978): "Methods of measurement for radio equipment used in satellite earth stations, Part 2: Measurements for sub-systems".
SIST ETS 300 423 E1:2003 Page 8 ETS 300 423: January 1995 [4] prETS 300 424 (1994): "Satellite Earth Stations and Systems (SES); Network Control Facilities (NCF) for Land Mobile Earth Stations (LMESs) operating in the 1,5/1,6 GHz bands providing voice and/or data communications". [5] IEC 801-3 (1984): "Electromagnetic compatibility for industrial process measurement and control equipment; Part 3: Radiated electromagnetic field requirements".
[6] CISPR 16 (1987): "Specifications for radio interference measuring apparatus and measurements methods".
3 Definitions and abbreviations
3.1 Definitions
For the purposes of this ETS, the following definitions apply:
directional antenna: An antenna with a transmit gain equal to or greater than 10 dBi. Installable Equipment (IE): An equipment which is intended to be installed in a vehicle. An IE may consist of one or several interconnected modules as follows:
Internally Mounted Equipment (IME) and Externally Mounted Equipment (EME): The manufacturer indicates which modules are intended to be Externally Mounted Equipment (EME); the remaining module(s) are then defined as Internally Mounted Equipment (IME). Where different specifications apply to IME and EME, this is noted in the relevant text.
nominated bandwidth: The nominated bandwidth encompasses all spectral elements of the transmission which have a level greater than the specified spurious levels. The nominated bandwidth is wide enough to take account of the transmit carrier frequency stability. The nominated bandwidth is within the LMSS transmit frequency band within which the MES operates. The bandwidth of the MES radio frequency transmission is nominated by the manufacturer and included in the data sheet of the test report. Portable Equipment (PE): A portable equipment is generally intended to be self-contained, free standing and portable. A PE would normally consist of a single module, but may consist of several interconnected modules. In some cases different specifications apply to PE and this is noted in the relevant text. unwanted emissions: Unwanted emissions are those falling outside the nominated bandwidth.
3.2 Abbreviations
For the purposes of this ETS, the following abbreviations apply:
CMF Control and Monitoring Function EIRP Equivalent Isotropically Radiated Power EM Electro-Magnetic EME Externally Mounted Equipment EUT Equipment Under Test IE Installable Equipment IME Internally Mounted Equipment LMES Land Mobile Earth Station LMSS Land Mobile Satellite Service MES Mobile Earth Station NCF Network Control Facilities PE Portable Equipment RF Radio Frequency rms root mean square s second STE Special Test Equipment
SIST ETS 300 423 E1:2003 Page 9 ETS 300 423: January 1995
4 Test report
The test report shall contain:
- the value of the nominated bandwidth, declared by the manufacturer;
- the results of the tests;
- all parameters and operational conditions.
5 Safety
5.1 Mechanical construction
Purpose:
Protection of operating personnel, the public and goods from insecure or unsafe structures. Specification:
For Installable Equipment (IE) and Portable Equipment (PE) the mechanical design, construction and finish of the equipment shall conform to IEC 215 [1], section 3, paragraph 9.1. Verification:
Verification shall be demonstrated by documentary evidence and visual inspection.
5.2 Electrical safety, power voltages
Purpose:
Protection of operating personnel and the public from electric shock. Specification:
The electrical safety of the equipment shall be in accordance with paragraphs 13, 14, 15 and 16 and Appendix B of IEC 215 [1].
Verification:
Conformance shall be demonstrated by documentary evidence and visual inspection.
5.3 Radio frequency radiation protection
Purpose:
To indicate the distance from the MES below which RF power densities in excess of 8 W/m may be experienced, when averaged over a 6 minute period.
Specification:
The radiating part of the equipment (which includes the exterior of any radome or other antenna enclosure where fitted) shall be labelled with a warning notice which shall be clearly visible when the equipment is in its normal operating configuration. This notice shall indicate the closest distance to the radiating part within which a person may approach the equipment without experiencing radio frequency power density levels in
excess of 8 W/m , when under worst case conditions (e.g. maximum power, maximum on/off ratio), averaged over a 6 minute period. This notice shall also state that before approaching the radiating part within any distance closer than that indicated, the MES equipment shall be switched off or otherwise disabled so that it shall not transmit.
SIST ETS 300 423 E1:2003 Page 10 ETS 300 423: January 1995 Where the equipment is vehicle mounted a warning notice providing the same information as that affixed to the radiating part shall be provided for fixing in the vehicle near to and clearly visible from the normal operating position of the IME. In addition, for vehicle mounted equipment where the radiating part is mounted in a position where it is not normally visible to a person standing on the ground next to the vehicle, further warning labels shall be provided with instructions that they be attached to the vehicle so as to be clearly visible to anyone attempting to climb on to the part of the vehicle where the radiating part of the equipment is mounted.
In the case where the antenna is enclosed in a radome or other antenna enclosure and no RF power
density greater than 8 W/m , when under worst case conditions (e.g. maximum power, maximum on/off ratio) averaged over a 6 minute period, is produced outside of this radome or antenna enclosure, then it is not necessary to label the radiating part or provide labels for the vehicle in the manner indicated above. Instead, the radiating part shall be clearly labelled with a warning that the MES equipment shall be switched off, or otherwise disabled, so that it shall not transmit before any work requiring the removal of the radome or antenna enclosure takes place. Where the equipment is vehicle mounted, a label containing the same warning shall be provided, to be mounted in the vehicle near to, and clearly visible from, the normal operating position of the IME.
Verification:
Verification of the distance below which exist RF power densities in excess of 8 W/m , when under worst case conditions (e.g. maximum power, maximum on/off ratio) averaged over a 6 minute period, shall be demonstrated by documentary evidence. The manufacturer shall quantify the worst case conditions.
6 Radio Frequency (RF)
In this clause, whenever a change of limit between adjacent frequency bands occurs, the lower of the two limits shall apply at the transition frequency.
6.1 Unwanted emission outside the bands 1 631,5 to 1 634,5 MHz and 1 656,5 to 1 660,5 MHz
Purpose:
Protection of other terrestrial and satellite services from emissions caused by MESs outside the bands 1 631,5 to 1 634,5 MHz and 1 656,5 to 1 660,5 MHz.
Specification:
The unwanted emissions from MESs outside the band 1 631,5 to 1 634,5 MHz and 1 656,5 to 1 660,5 MHz within which the MES is designed to operate shall be below the following limits. For unwanted emissions below 960 MHz, the MESs shall meet the requirements of CISPR 22 [2] for class B equipment with carrier on given in table 1.
Table 1 Limits of unwanted emissions at a test distance of 10 m in any 120 kHz band Frequency Quasi-peak limits (dBμV/m) 30 MHz to 230 MHz 30 230 MHz to 960 MHz 37 The unwanted emission EIRP above 960 MHz in the measurement bandwidth in all directions shall not exceed the limits in table 2.
SIST ETS 300 423 E1:2003 Page 11 ETS 300 423: January 1995 Table 2 Frequency range Carrier On Carrier Off MHz EIRP limit (dBpW) Measurement EIRP limit (dBpW) Measurement bandwidth (kHz) bandwidth (kHz) 960,0 - 1 525,0 49 100 48 100 1 525,0 - 1 559,0 49 100 17 3 1 559,0 - 1 600,0 49 100 48 100 1 600,0 - 1 625,8 74 100 48 (note 5) 100 1 625,8 - 1 631,5 (note 1) (note 1) 57 3 1 634,5 - 1 656,5 (note 1) (note 1) 57 3 1 660,5 - 1 661,2 (note 1) (note 1) 57 3 1 661,2 - 1 690,0 74 100 48 (note 5) 100 1 690,0 - 3 400,0 49 (note 2) 100 48 100 3 400 - 10 700 55 100 48 100 (notes 3 & 4) 10 700 - 21 200 61 100 54 100 21 200 - 40 000 67 100 60 100 NOTE 1: The limit of subclause 6.2 (in-band unwanted emission limit) shall apply and in any 3 kHz frequency band the EIRP including the spectrum lines shall not exceed 104 dBpW. NOTE 2: In the band 3 263,0 to 3 321,0 MHz the maximum EIRP in one, and only one, 100 kHz measurement bandwidth shall not exceed 82 dBpW. Prior to 1 January 1998 this figure shall be 92 dBpW. Elsewhere in this band the power limit in table 2 shall be applied. NOTE 3: In each of the bands 4 894,5 to 4 981,5 MHz, 6 526,0 to 6 642,0 MHz and 8 157,5 to 8 302,5 MHz the maximum EIRP in one, and only one, 100 kHz measurement bandwidth shall not exceed 72 dBpW. Prior to 1 January 1998 this figure shall be 82 dBpW. Elsewhere in this band the power limit in table 2 shall be applied.
NOTE 4: In the band 9 789,0 to 9 963,0 MHz the maximum power in one, and only one, 100 kHz measurement bandwidth shall not exceed 61 dBpW. Prior to 1 January 1998 this figure shall be 71 dBpW. Elsewhere in this band the power limit in table 2 shall be applied. NOTE 5: Prior to 1 January 1998 this figure shall be 51 dBpW.
Verification:
By measurement of unwanted emissions generated by an operating MES. All RF tests in this subclause shall be carried out at ambient environmental conditions and for a nominal power supply voltage.
All tests with carrier on shall be undertaken with the transmitter operating at full power and with the maximum transmit burst rate where applicable.
To enable the performance tests to be carried out, the use of Special Test Equipment (STE), supplied by the manufacturer or system provider, may be necessary. Since this test equipment will be specific for the particular system, it is not possible to provide detailed specifications in this ETS. However, the following baseline is provided:
- if the MES requires to receive a modulated carrier from the satellite in order to transmit, then special test arrangements are required to simulate the satellite signal, thus enabling the MES to transmit allowing measurement of transmission parameters;
- any specification of these special test arrangements which may have direct or indirect effects on any requirement or recommendation of this ETS shall be clearly stated by the manufacturer.
SIST ETS 300 423 E1:2003 Page 12 ETS 300 423: January 1995 Test procedure:
Below 960 MHz, the test procedures set out in CISPR 22 [2], paragraphs 6, 7, 8, 9 and 11 shall be used. Above 960 MHz, the full system shall be tested according to the test procedure given in annex B. The upper frequency to which tests shall be performed shall be at least the 10th harmonic of the highest frequency conversion oscillator or ten times the highest operational frequency, whichever is greater. Where possible, up to four MES transmit frequencies shall be used for this test; the frequencies shall be selected to be as close as possible to the upper and lower limits of the transmit frequency sub-band(s) used by the MES declared by the manufacturer, to be intended for operational use of the MES. The upper and lower extremes of the tuning range stated by the manufacturer shall be entered in the test report.
6.2 Maximum unwanted emission within the 1 631,5 to 1 634,5 MHz and 1 656,5 to
1 660,5 MHz bands Purpose:
Protection of satellite and terrestrial services operating in the above frequency bands. Specification:
The unwanted emission EIRP in any 3 kHz band within the 1 631,5 to 1 634,5 MHz and 1 656,5 to 1 660,5 MHz bands in which the MES is designed to transmit, but outside the nominated bandwidth, shall not exceed the following limits:
- when the carrier is off: 57 dBpW;
- when the carrier is on: the limits of table 3.
Table 3 Offset from the edge of the band of the Maximum EIRP (dBpW) nominated bandwidth (kHz) 0 to 10 125 10 to 20 110 20 to 100 105 100 to 200 95 200 to 700 88 (note 1) greater than 700 78 (note 1) NOTE: Future considerations may be given to reducing this figure by up to 3 dB. The limits of table 3 do not apply to spectrum lines, but the total EIRP of the unwanted emissions, including spectrum lines, shall not exceed 128 dBpW.
Verification:
Conformance shall be determined by direct measurement.
The conditions (environment, power, special test equipment (STE) etc.) set out in the verification section of subclause 6.1 shall apply.
Test procedure:
The measurement shall be performed by either of the two following methods:
...