SIST EN 10365:2026
(Main)Hot rolled steel channels, I and H sections - Dimensions and masses
- Abstract
This document specifies the nominal dimensions and masses of the hot rolled steel channels, I and H sections.
The following shapes are covered by this document:
Sections:
- parallel flange I sections IPE;
- parallel wide flange beams HE;
- parallel extra wide flange beams HL and HLZ;
- parallel wide flange columns HD;
- parallel wide flange bearing piles HP and UBP;
- parallel flange universal beams UB;
- parallel flange universal columns UC;
- taper flange I sections IPN and J.
Channels:
- parallel flange channels UPE and PFC;
- taper flange channels UPN, U and CH.
These requirements do not apply to hot rolled steel channels, I- and H- sections from stainless steel.
- Status
- Published
- Public Enquiry End Date
- 30-Jul-2025
- Publication Date
- 13-Jul-2026
- Technical Committee
- IFEK - Ferrous metals
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 09-Jul-2026
- Due Date
- 13-Sep-2026
- Completion Date
- 14-Jul-2026
SIST EN 10365:2026 is the Slovenian adoption of EN 10365:2026, published by SIST and aligned with CEN. It specifies the nominal dimensions and masses of hot rolled steel channels, I and H sections. The standard is meant for engineers, purchasers, fabricators and quality staff who need a common size system for these steel profiles.
What does SIST EN 10365:2026 specify?
SIST EN 10365:2026 specifies the nominal dimensions and masses for a defined range of hot rolled steel channels, I sections and H sections. It is a product dimension standard, so it is mainly used to identify the section shape and size to order, manufacture and check.
The scope covers these section families:
| Family | What it covers |
|---|---|
| IPE | Parallel flange I sections |
| HE | Parallel wide flange beams |
| HL, HLZ | Parallel extra wide flange beams |
| HD | Parallel wide flange columns |
| HP, UBP | Parallel wide flange bearing piles |
| UB | Parallel flange universal beams |
| UC | Parallel flange universal columns |
| IPN, J | Taper flange I sections |
| UPE, PFC | Parallel flange channels |
| UPN, U, CH | Taper flange channels |
SIST EN 10365:2026 does not apply to hot rolled steel channels, I- and H-sections from stainless steel. The document is organized into Scope, Normative references, Terms and definitions, Designation, Dimensions and masses, Tolerances on dimensions, shape and mass, and Material, followed by two informative annexes.
What are the key requirements of SIST EN 10365:2026?
SIST EN 10365:2026 makes the section tables the basis for identification, ordering and checking. In practice, the buyer or designer must select the exact tabulated designation and the correct family before the section can be specified.
Designation and ordering
Clause 4 says each section shall be designated according to Tables 1 to 15, and that this designation shall be used in enquiries and orders. That matters because the tables are the official naming and size reference for procurement and downstream checking.
Nominal dimensions and masses
Clause 5 states that the covered sections shall be manufactured to the dimensions in Tables 1 to 15 and Figures 1 to 4. The tables also give the mass per unit length. For users, this means the document is a direct reference for nominal size selection and shipping, handling and steel take-off calculations.
Geometry used only for calculation
Clause 5 also notes that radii of fillets, toes of shape profiles and angles for taper flanges vary by manufacturer and are not specified. Any radii or angles given by the manufacturer, or fixed otherwise, are only for calculating nominal sectional properties and cannot be used for other purposes. In practice, that prevents using those features as a manufacturing or acceptance criterion unless another document or agreement says so.
Basis for mass values
Clause 5 says the masses per unit length in Tables 1 to 15 were calculated using a density of 7 850 kg/m³. That matters when comparing table values with internal calculations or software, because the tabulated mass is derived from a common density basis.
Tolerances come from the matching tolerance standards
Clause 6 routes tolerances to the relevant companion standards:
- EN 10034 for I and H sections with parallel flanges
- EN 10024 for taper flange I sections
- EN 10279 for channels
For shapes not covered by those standards, tolerances are to be agreed between manufacturer and purchaser. In practice, this means SIST EN 10365:2026 gives the nominal geometry, while the separate tolerance standards control permitted variation.
Material is linked to the delivery standards
Clause 7 says sections and channels should preferably be made from steel grades in EN 10025-2, EN 10025-3, EN 10025-4 and EN 10025-5. Other grades from EN 10225-2, EN 10028-2 and EN 10273 may also be used for specific applications, and the desired steel grade shall be specified when ordering. This is important because size designation alone is not enough for procurement or traceability.
Sectional properties are calculated in Annex A
Annex A gives formulae for calculating nominal sectional properties. It covers parallel flange I- and H-sections, taper flange I-sections, parallel U-sections and taper flange U-sections. For design work, that lets engineers derive area, second moments of area, radii of gyration and elastic section modulus from the nominal dimensions.
What terms does SIST EN 10365:2026 define?
SIST EN 10365:2026 uses the terms and definitions of EN 10079. A few key terms are especially useful when reading the tables and annexes:
- Nominal dimensions - the stated reference dimensions used to identify a section in the tables and in ordering.
- Mass per unit length - the mass of one metre of section, given in the tables for logistics and design take-off.
- Designation - the formal section name and size combination used in enquiries and orders.
- Parallel flange sections - sections such as IPE, HE, HL, HD, HP, UBP, UB and UC with parallel flanges.
- Taper flange sections - sections such as IPN, J, UPN, U, CH and taper flange I-type sections with flanges that are not parallel.
- Sectional properties - calculated values such as area and second moments of area used in structural design.
- EN 10079 - the vocabulary reference that supplies the terms and definitions used by this document.
Who uses SIST EN 10365:2026?
SIST EN 10365:2026 is used by structural steel designers, steelwork fabricators, stockholders, purchasers and quality personnel. Designers use it to choose the correct section family and size, and to read the properties needed for structural calculations.
Buyers and order planners use it to write unambiguous enquiries and purchase orders. Fabricators and inspectors use it to check delivered section sizes, masses and the applicable tolerance standard. Steel producers use it to identify the nominal product range they supply.
What changed in SIST EN 10365:2026 from the previous edition?
SIST EN 10365:2026 supersedes EN 10365:2017. The foreword states three technical changes:
- addition of diverse new dimensions
- addition of Annex A with formulae for static values
- editorial update
Which standards are used with SIST EN 10365:2026?
The document cites these normative references:
- EN 10024 - provides tolerances on shape and dimensions for hot rolled taper flange I sections.
- EN 10025-2 - gives technical delivery conditions for non-alloy structural steels.
- EN 10025-3 - gives technical delivery conditions for normalized/normalized rolled weldable fine grain structural steels.
- EN 10025-4 - gives technical delivery conditions for thermomechanical rolled weldable fine grain structural steels.
- EN 10025-5 - gives technical delivery conditions for structural steels with improved atmospheric corrosion resistance.
- EN 10034 - gives tolerances on shape and dimensions for structural steel I and H sections.
- EN 10079 - provides the steel product definitions used in Clause 3.
- EN 10279 - gives tolerances on shape, dimensions and mass for hot rolled steel channels.
What does the SIST EN 10365:2026 document contain?
SIST EN 10365:2026 contains 15 tables of nominal dimensions and masses covering the section families listed in the scope. It also includes Figures 1 to 4, which show the section shapes and the key dimensions used in the tables.
Annex A provides calculation formulae for sectional properties, including area, mass per unit length and structural section properties for the main section types. Annex B compares the symbols used in EN 10024, EN 10034 and EN 10279 with the symbols used in this document and in EN 1993-1-1, which helps when moving between product standards and structural design documents.
Relations
- Effective Date
- 29-Jul-2026
- Effective Date
- 29-Jul-2026
- Effective Date
- 29-Jul-2026
- Effective Date
- 29-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 08-Jul-2026
- Effective Date
- 19-Jan-2023
Get Certified
Connect with accredited certification bodies for this standard

Element Materials Technology
Materials testing and product certification.

Inštitut za kovinske materiale in tehnologije
Institute of Metals and Technology. Materials testing, metallurgical analysis, NDT.
Sponsored listings
Frequently Asked Questions
SIST EN 10365:2026 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Hot rolled steel channels, I and H sections - Dimensions and masses". This standard covers: This document specifies the nominal dimensions and masses of the hot rolled steel channels, I and H sections. The following shapes are covered by this document: Sections: - parallel flange I sections IPE; - parallel wide flange beams HE; - parallel extra wide flange beams HL and HLZ; - parallel wide flange columns HD; - parallel wide flange bearing piles HP and UBP; - parallel flange universal beams UB; - parallel flange universal columns UC; - taper flange I sections IPN and J. Channels: - parallel flange channels UPE and PFC; - taper flange channels UPN, U and CH. These requirements do not apply to hot rolled steel channels, I- and H- sections from stainless steel.
This document specifies the nominal dimensions and masses of the hot rolled steel channels, I and H sections. The following shapes are covered by this document: Sections: - parallel flange I sections IPE; - parallel wide flange beams HE; - parallel extra wide flange beams HL and HLZ; - parallel wide flange columns HD; - parallel wide flange bearing piles HP and UBP; - parallel flange universal beams UB; - parallel flange universal columns UC; - taper flange I sections IPN and J. Channels: - parallel flange channels UPE and PFC; - taper flange channels UPN, U and CH. These requirements do not apply to hot rolled steel channels, I- and H- sections from stainless steel.
SIST EN 10365:2026 is classified under the following ICS (International Classification for Standards) categories: 77.140.70 - Steel profiles. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 10365:2026 has the following relationships with other standards: It is inter standard links to SIST EN 10024:1996, SIST EN 10279:2000, SIST EN 10079:2007, SIST EN 10034:1997, SIST EN 1090-2:2018+A1:2024, SIST EN 10025-3:2019, SIST-TS CEN/TS 17991:2024, SIST EN 1090-2:2018, SIST EN 10025-4:2019, SIST EN 10025-4:2019+A1:2023, SIST EN 10025-2:2019, SIST EN 10025-5:2019, SIST EN 10365:2017. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
SIST EN 10365:2026 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Designation
- 5 Dimensions and masses
- 6 Tolerances on dimensions, shape and mass
- 7 Material
- Annex A
- Annex B
- Bibliography
1 Scope
This document specifies the nominal dimensions and masses of the hot rolled steel channels, I and H sections.
The following shapes are covered by this document:
Sections:
- parallel flange I sections IPE;
- parallel wide flange beams HE;
- parallel extra wide flange beams HL and HLZ;
- parallel wide flange columns HD;
- parallel wide flange bearing piles HP and UBP;
- parallel flange universal beams UB;
- parallel flange universal columns UC;
- taper flange I sections IPN and J.
Channels:
- parallel flange channels UPE and PFC;
- taper flange channels UPN, U and CH.
These requirements do not apply to hot rolled steel channels, I- and H- sections from stainless steel.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 10024, Hot rolled taper flange I sections — Tolerances on shape and dimensions EN 10025-2, Hot rolled products of structural steels — Part 2: Technical delivery conditions for non-alloy structural steels EN 10025-3, Hot rolled products of structural steels — Part 3: Technical delivery conditions for normalized/normalized rolled weldable fine grain structural steels EN 10025-4, Hot rolled products of structural steels — Part 4: Technical delivery conditions for thermomechanical rolled weldable fine grain structural steels EN 10025-5, Hot rolled products of structural steels — Part 5: Technical delivery conditions for structural steels with improved atmospheric corrosion resistance EN 10034, Structural steel I and H sections — Tolerances on shape and dimensions EN 10079, Definition of steel products EN 10279, Hot rolled steel channels — Tolerances on shape, dimensions and mass
SIST EN 10365:2026 EN 10365:2026 (E)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 10079 apply. ISO and IEC maintain terminology databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https://www.iso.org/obp/
- IEC Electropedia: available at https://www.electropedia.org/
4 Designation
A section shall be designated according to Tables 1 to 15.
This form of designation shall be used in any enquiry and order.
5 Dimensions and masses
Hot rolled steel channels, I and H sections complying with this document shall be manufactured with the specified dimensions given in the Table 1 to 15 and according to Figures 1 to 4 below. Radii of fillets, toes of shape profiles and angles for taper flanges vary with individual manufacturers and therefore are not specified. Radii and angles given by the manufacturer or fixed otherwise, are only for the calculation of the nominal sectional properties and cannot be used for any other purpose. NOTE Concerning the comparable ISO standard for taper flange sections (i.e. ISO 657-1) the kinds of sections are different and the measuring point for the flange thickness is also different. The masses per unit length specified in Tables 1 to 15 were calculated on the basis of a density of
7 850 kg/m .
Figure 1 — IPE, HE, HL, HLZ, HD, HP, UBP, UB and UC parallel flange sections
SIST EN 10365:2026 EN 10365:2026 (E)
Key for IPN-sections:
taper flange angle α = 14 % Figure 2 — Taper flange I sections IPN and J
Figure 3 — Parallel flange channels UPE and PFC
SIST EN 10365:2026 EN 10365:2026 (E)
Key for UPN-channels:
h ≤ 300 mm taper flange angle α = 8 % and b1 = b/2 h > 300 mm taper flange angle α = 5 % and b1 = (b-tw)/2 for CH- and U-channels: b = b/2
Figure 4 — Taper flange channels UPN, U and CH
6 Tolerances on dimensions, shape and mass
Tolerances on dimensions, shape and mass shall be as given in EN 10034 for I (parallel flanges) and H sections.
Tolerances on dimensions, shape and mass shall be as given in EN 10024 for taper flange I sections. Tolerances on dimensions, shape and mass shall be as given in EN 10279 for channels. Tolerances for shapes not included in the mentioned standards shall be as agreed upon between the manufacturer and the purchaser.
7 Material
Sections and channels shall preferably be made from steel of a grade as specified in EN 10025-2, EN 10025-3, EN 10025-4 and EN 10025-5. Other steel grades as specified in EN 10225-2, EN 10028-2 and EN 10273 may also be used for specific applications.
The desired steel grade shall be specified at the time of ordering.
SIST EN 10365:2026 EN 10365:2026 (E) Table 1 — Parallel flange I sections IPE Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm IPE AA 80 4,9 78,0 46,0 3,2 4,2 6,3 IPE A 80 5,0 78,0 46,0 3,3 4,2 6,4 IPE 80 6,0 80,0 46,0 3,8 5,2 7,6 IPE AA 100 6,7 97,6 55,0 3,6 4,5 8,6 IPE A 100 6,9 98,0 55,0 3,6 4,7 8,8 IPE 100 8,1 100,0 55,0 4,1 5,7 10,3 IPE AA 120 8,4 117,0 64,0 3,8 4,8 10,7 IPE A 120 8,7 117,6 64,0 3,8 5,1 11,0 IPE 120 10,4 120,0 64,0 4,4 6,3 13,2 IPE AA 140 10,1 136,6 73,0 3,8 5,2 12,8 IPE A 140 10,5 137,4 73,0 3,8 5,6 13,4 IPE 140 12,9 140,0 73,0 4,7 6,9 16,4 IPE AA 160 12,3 156,4 82,0 4,0 5,6 15,7 IPE A 160 12,7 157,0 82,0 4,0 5,9 16,2 IPE 160 15,8 160,0 82,0 5,0 7,4 20,1 IPE AA 180 14,9 176,4 91,0 4,3 6,2 19,0 IPE A 180 15,4 177,0 91,0 4,3 6,5 19,6 IPE 180 18,8 180,0 91,0 5,3 8,0 23,9 IPE O 180 21,3 182,0 92,0 6,0 9,0 27,1 IPE AA 200 18,0 196,4 100,0 4,5 6,7 22,9 IPE A 200 18,4 197,0 100,0 4,5 7,0 23,5 IPE 200 22,4 200,0 100,0 5,6 8,5 28,5 IPE O 200 25,1 202,0 102,0 6,2 9,5 32,0 IPE AA 220 21,2 216,4 110,0 4,7 7,4 27,0 IPE A 220 22,2 217,0 110,0 5,0 7,7 28,3 IPE 220 26,2 220,0 110,0 5,9 9,2 33,4 IPE O 220 29,4 222,0 112,0 6,6 10,2 37,4 IPE AA 240 24,9 236,4 120,0 4,8 8,0 31,7 IPE A 240 26,2 237,0 120,0 5,2 8,3 33,3 IPE 240 30,7 240,0 120,0 6,2 9,8 39,1 IPE O 240 34,3 242,0 122,0 7,0 10,8 43,7 IPE A 270 30,7 267,0 135,0 5,5 8,7 39,2 IPE 270 36,1 270,0 135,0 6,6 10,2 45,9 IPE O 270 42,3 274,0 136,0 7,5 12,2 53,8 IPE A 300 36,5 297,0 150,0 6,1 9,2 46,5 IPE 300 42,2 300,0 150,0 7,1 10,7 53,8 IPE O 300 49,3 304,0 152,0 8,0 12,7 62,8
SIST EN 10365:2026 EN 10365:2026 (E) Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm IPE A 330 43,0 327,0 160,0 6,5 10,0 54,7 IPE 330 49,1 330,0 160,0 7,5 11,5 62,6 IPE O 330 57,0 334,0 162,0 8,5 13,5 72,6 IPE AA 360 47,0 356,4 170,0 6,0 10,9 59,9 IPE A 360 50,2 357,6 170,0 6,6 11,5 64,0 IPE 360 57,1 360,0 170,0 8,0 12,7 72,7 IPE O 360 66,0 364,0 172,0 9,2 14,7 84,1 IPE AA 400 53,4 395,6 180,0 6,3 11,3 68,0 IPE A 400 57,4 397,0 180,0 7,0 12,0 73,1 IPE 400 66,3 400,0 180,0 8,6 13,5 84,5 IPE O 400 75,7 404,0 182,0 9,7 15,5 96,4 IPE V 400 84,0 408,0 182,0 10,6 17,5 107,0 IPE AA 450 62,1 445,4 190,0 6,8 12,3 79,1 IPE A 450 67,2 447,0 190,0 7,6 13,1 85,6 IPE 450 77,6 450,0 190,0 9,4 14,6 98,8 IPE O 450 92,4 456,0 192,0 11,0 17,6 117,7 IPE V 450 107 460,0 194,0 12,4 19,6 132,0 IPE AA 500 73,2 495,2 200,0 7,5 13,6 93,3 IPE A 500 79,4 497,0 200,0 8,4 14,5 101,1 IPE 500 90,7 500,0 200,0 10,2 16,0 115,5 IPE O 500 107 506,0 202,0 12,0 19,0 136,7 IPE V 500 129 514,0 204,0 14,2 23,0 164,1 IPE AA 550 79,5 541,0 210,0 8,5 12,5 101,3 IPE AA 550x85 84,7 545,0 210,0 8,0 14,7 108,0 IPE A 550 92,1 547,0 210,0 9,0 15,7 117,3 IPE 550 106 550,0 210,0 11,1 17,2 134,4 IPE O 550 123 556,0 212,0 12,7 20,2 156,1 IPE V 550 159 566,0 216,0 17,1 25,2 202,0 IPE A 600 108 597,0 220,0 9,8 17,5 137,0 IPE 600 122 600,0 220,0 12,0 19,0 156,0 IPE O 600 154 610,0 224,0 15,0 24,0 196,8 IPE V 600 184 618,0 228,0 18,0 28,0 233,8 IPE 750 × 134 134 750,0 264,0 12,0 15,5 170,6 IPE 750 × 147 147 753,0 265,0 13,2 17,0 187,5 IPE 750 × 173 173 762,0 267,0 14,4 21,6 221,3 IPE 750 × 196 196 770,0 268,0 15,6 25,4 250,8 IPE 750 × 220 220 779,0 266,0 16,5 30,0 280,7
SIST EN 10365:2026 EN 10365:2026 (E) Table 2 — Wide flange beams HE Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm HE 100 AA 12,2 91,0 100,0 4,2 5,5 15,6 HE 100 A 16,7 96,0 100,0 5,0 8,0 21,2 HE 100 B 20,4 100,0 100,0 6,0 10,0 26,0 HE 100 C 30,9 110,0 103,0 9,0 15,0 39,3 HE 100 M 41,8 120,0 106,0 12,0 20,0 53,2 HE 120 AA 14,6 109,0 120,0 4,2 5,5 18,6 HE 120 A 19,9 114,0 120,0 5,0 8,0 25,3 HE 120 B 26,7 120,0 120,0 6,5 11,0 34,0 HE 120 C 39,2 130,0 123,0 9,5 16,0 49,9 HE 120 M 52,1 140,0 126,0 12,5 21,0 66,4 HE 140 AA 18,1 128,0 140,0 4,3 6,0 23,0 HE 140 A 24,7 133,0 140,0 5,5 8,5 31,4 HE 140 B 33,7 140,0 140,0 7,0 12,0 43,0 HE 140 C 48,2 150,0 143,0 10,0 17,0 61,5 HE 140 M 63,2 160,0 146,0 13,0 22,0 80,6 HE 160 AA 23,8 148,0 160,0 4,5 7,0 30,4 HE 160 A 30,4 152,0 160,0 6,0 9,0 38,8 HE 160 B 42,6 160,0 160,0 8,0 13,0 54,3 HE 160 C 59,2 170,0 163,0 11,0 18,0 75,4 HE 160 M 76,2 180,0 166,0 14,0 23,0 97,1 HE 180 AA 28,7 167,0 180,0 5,0 7,5 36,5 HE 180 A 35,5 171,0 180,0 6,0 9,5 45,3 HE 180 B 51,2 180,0 180,0 8,5 14,0 65,3 HE 180 C 69,8 190,0 183,0 11,5 19,0 89,0 HE 180 M 88,9 200,0 186,0 14,5 24,0 113,3 HE 200 AA 34,6 186,0 200,0 5,5 8,0 44,1 HE 200 A 42,3 190,0 200,0 6,5 10,0 53,8 HE 200 B 61,3 200,0 200,0 9,0 15,0 78,1 HE 200 C 81,9 210,0 203,0 12,0 20,0 104,4 HE 200 M 103 220,0 206,0 15,0 25,0 131,3 HE 220 AA 40,4 205,0 220,0 6,0 8,5 51,5 HE 220 A 50,5 210,0 220,0 7,0 11,0 64,3 HE 220 B 71,5 220,0 220,0 9,5 16,0 91,0 HE 220 C 94,1 230,0 223,0 12,5 21,0 119,9 HE 220 M 117 240,0 226,0 15,5 26,0 149,4
SIST EN 10365:2026 EN 10365:2026 (E) Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm HE 240 AA 47,4 224,0 240,0 6,5 9,0 60,4 HE 240 A 60,3 230,0 240,0 7,5 12,0 76,8 HE 240 B 83,2 240,0 240,0 10,0 17,0 106,0 HE 240 C 119 255,0 244,0 14,0 24,5 152,2 HE 240 M 157 270,0 248,0 18,0 32,0 199,6 HE 260 AA 54,1 244,0 260,0 6,5 9,5 69,0 HE 260 A 68,2 250,0 260,0 7,5 12,5 86,8 HE 260 B 93,0 260,0 260,0 10,0 17,5 118,4 HE 260 C 132 275,0 264,0 14,0 25,0 168,4 HE 260 M 172 290,0 268,0 18,0 32,5 219,6 HE 280 AA 61,2 264,0 280,0 7,0 10,0 78,0 HE 280 A 76,4 270,0 280,0 8,0 13,0 97,3 HE 280 B 103 280,0 280,0 10,5 18,0 131,4 HE 280 C 145 295,0 284,0 14,5 25,5 185,2 HE 280 M 189 310,0 288,0 18,5 33,0 240,2 HE 300 AA 69,8 283,0 300,0 7,5 10,5 88,9 HE 300 A 88,3 290,0 300,0 8,5 14,0 112,5 HE 300 B 117 300,0 300,0 11,0 19,0 149,1 HE 300 C 177 320,0 305,0 16,0 29,0 225,1 HE 300 M 238 340,0 310,0 21,0 39,0 303,1 HE 320 AA 74,2 301,0 300,0 8,0 11,0 94,6 HE 320 A 97,6 310,0 300,0 9,0 15,5 124,4 HE 320 B 127 320,0 300,0 11,5 20,5 161,3 HE 320 C 186 340,0 305,0 16,0 30,5 236,9 HE 320 M 245 359,0 309,0 21,0 40,0 312,0 HE 340 AA 78,9 320,0 300,0 8,5 11,5 100,5 HE 340 A 105 330,0 300,0 9,5 16,5 133,5 HE 340 B 134 340,0 300,0 12,0 21,5 170,9 HE 340 M 248 377,0 309,0 21,0 40,0 315,8 HE 360 AA 83,7 339,0 300,0 9,0 12,0 106,6 HE 360 A 112 350,0 300,0 10,0 17,5 142,8 HE 360 B 142 360,0 300,0 12,5 22,5 180,6 HE 360 M 250 395,0 308,0 21,0 40,0 318,8 HE 400 AA 92,4 378,0 300,0 9,5 13,0 117,7 HE 400 A 125 390,0 300,0 11,0 19,0 159,0 HE 400 B 155 400,0 300,0 13,5 24,0 197,8 HE 400 M 256 432,0 307,0 21,0 40,0 325,8
SIST EN 10365:2026 EN 10365:2026 (E) Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm HE 450 AA 99,7 425,0 300,0 10,0 13,5 127,1 HE 450 A 140 440,0 300,0 11,5 21,0 178,0 HE 450 B 171 450,0 300,0 14,0 26,0 218,0 HE 450 M 263 478,0 307,0 21,0 40,0 335,4 HE 500 AA 107 472,0 300,0 10,5 14,0 136,9 HE 500 A 155 490,0 300,0 12,0 23,0 197,5 HE 500 B 187 500,0 300,0 14,5 28,0 238,6 HE 500 M 270 524,0 306,0 21,0 40,0 344,3 HE 550 AA 120 522,0 300,0 11,5 15,0 152,8 HE 550 A 166 540,0 300,0 12,5 24,0 211,8 HE 550 B 199 550,0 300,0 15,0 29,0 254,1 HE 550 M 278 572,0 306,0 21,0 40,0 354,4 HE 600 AA 129 571,0 300,0 12,0 15,5 164,1 HE 600 A 178 590,0 300,0 13,0 25,0 226,5 HE 600 B 212 600,0 300,0 15,5 30,0 270,0 HE 600 M 285 620,0 305,0 21,0 40,0 363,7 HE 600 × 337 337 632,0 310,0 25,5 46,0 429,2 HE 600 × 399 399 648,0 315,0 30,0 54,0 508,5 HE 650 AA 138 620,0 300,0 12,5 16,0 175,8 HE 650 A 190 640,0 300,0 13,5 26,0 241,6 HE 650 B 225 650,0 300,0 16,0 31,0 286,3 HE 650 M 293 668,0 305,0 21,0 40,0 373,7 HE 650 × 343 343 680,0 309,0 25,0 46,0 437,5 HE 650 × 407 407 696,0 314,0 29,5 54,0 518,8 HE 700 AA 150 670,0 300,0 13,0 17,0 190,9 HE 700 A 204 690,0 300,0 14,5 27,0 260,5 HE 700 B 241 700,0 300,0 17,0 32,0 306,4 HE 700 M 301 716,0 304,0 21,0 40,0 383,0 HE 700 × 352 352 728,0 308,0 25,0 46,0 448,6 HE 700 × 418 418 744,0 313,0 29,5 54,0 531,9 HE 800 AA 172 770,0 300,0 14,0 18,0 218,5 HE 800 A 224 790,0 300,0 15,0 28,0 285,8 HE 800 B 262 800,0 300,0 17,5 33,0 334,2 HE 800 M 317 814,0 303,0 21,0 40,0 404,3 HE 800 × 373 373 826,0 308,0 25,0 46,0 474,6 HE 800 × 444 444 842,0 313,0 30,0 54,0 566,0
SIST EN 10365:2026 EN 10365:2026 (E) Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm HE 900 AA 198 870,0 300,0 15,0 20,0 252,2 HE 900 A 252 890,0 300,0 16,0 30,0 320,5 HE 900 B 291 900,0 300,0 18,5 35,0 371,3 HE 900 M 333 910,0 302,0 21,0 40,0 423,6 HE 900 × 391 391 922,0 307,0 25,0 46,0 497,7 HE 900 × 466 466 938,0 312,0 30,0 54,0 593,7 HE 1000 AA 222 970,0 300,0 16,0 21,0 282,2 HE 1000 × 249 249 980,0 300,0 16,5 26,0 316,8 HE 1000 A 272 990,0 300,0 16,5 31,0 346,8 HE 1000 B 314 1 000,0 300,0 19,0 36,0 400,0 HE 1000 M 349 1 008,0 302,0 21,0 40,0 444,2 HE 1000 × 393 393 1 016,0 303,0 24,4 43,9 500,2 HE 1000 × 415 415 1 020,0 304,0 26,0 46,0 528,7 HE 1000 × 438 438 1 026,0 305,0 26,9 49,0 556,0 HE 1000 × 494 494 1 036,0 309,0 31,0 54,0 629,1 HE 1000 × 584 584 1 056,0 314,0 36,0 64,0 743,7
Table 3 — Extra wide flange beams HL and HLZ Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm HL 920 × 344 344 927,0 418,0 19,3 32,0 437,2 HL 920 × 368 368 931,0 419,0 20,3 34,3 465,6 HL 920 × 390 390 936,0 420,0 21,3 36,6 494,3 HL 920 × 420 420 943,0 422,0 22,5 39,9 534,1 HL 920 × 449 449 948,0 423,0 24,0 42,7 571,4 HL 920 × 491 491 957,0 422,0 25,9 47,0 623,3 HL 920 × 537 537 965,0 425,0 28,4 51,1 682,5 HL 920 × 588 588 975,0 427,0 31,0 55,9 748,1 HL 920 × 656 656 987,0 431,0 34,5 62,0 835,3 HL 920 × 725 725 999,0 434,0 38,1 68,1 922,9 HL 920 × 787 787 1 011,0 437,0 40,9 73,9 1 002,0 HL 920 × 970 970 1 043,0 446,0 50,0 89,9 1 236,6 HL 920 × 1077 1 077 1 061,0 451,0 55,0 99,1 1 371,5 HL 920 × 1194 1 194 1 081,0 457,0 60,5 109,0 1 521,5 HL 920 × 1269 1 269 1 093,0 461,0 64,0 115,1 1 616,5 HL 920 × 1377 1 377 1 093,0 473,0 76,7 115,1 1 753,7
SIST EN 10365:2026 EN 10365:2026 (E) Designation Dimensions M h b tw tf A
kg/m mm mm mm mm cm HL 1000 AA 296 982,0 400,0 16,5 27,1 377,6 HL 1000 A 321 990,0 400,0 16,5 31,0 408,8 HL 1000 B 371 1 000,0 400,0 19,0 36,1 472,8 HL 1000 M 412 1 008,0 402,0 21,1 40,0 525,1 HL 1000 × 443 443 1 012,0 402,0 23,6 41,9 563,7 HL 1000 × 483 483 1 020,0 404,0 25,4 46,0 615,1 HL 1000 × 539 539 1 030,0 407,0 28,4 51,1 687,2 HL 1000 × 554 554 1 032,0 408,0 29,5 52,0 705,8 HL 1000 × 591 591 1 040,0 409,0 31,0 55,9 752,7 HL 1000 × 642 642 1 048,0 412,0 34,0 60,0 817,6 HL 1000 × 748 748 1 068,0 417,0 39,0 70,0 953,4 HL 1000 × 883 883 1 092,0 424,0 45,5 82,0 1125,3 HL 1000 × 976 976 1 108,0 428,0 50,0 89,9 1241,4 HL 1100 A 343 1 090,0 400,0 18,0 31,0 436,5 HL 1100 B 390 1 100,0 400,0 20,0 36,0 497,0 HL 1100 M 433 1 108,0 402,0 22,0 40,0 551,2 HL 1100 R 499 1 118,0 405,0 26,0 45,0 635,2 HL 1100 × 548 548 1 128,0 407,0 28,0 50,0 698,3 HL 1100 × 607 607 1 138,0 410,0 31,0 55,0 773,1 HLZ 1100 A 393 1 075,4 458,0 20,0 31,0 500,8 HLZ 1100 B 408 1 079,4 458,0 20,0 33,0 519,1 HLZ 1100 C 430 1 083,4 459,0 21,0 35,0 548,3 HLZ 1100 D 453 1 087,4 460,0 22,0 37,0 577,5
SIST EN 10365:2026 EN 10365:2026 (E) Table 4 — Wide flange columns HD Designation Dimensions M h b tw tf A
...