oSIST prEN 50377-14-1:2009
(Main)Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1: Patch cords with EN 60793-2-50 single mode category B1.1 and B1.3 fibre for category C
Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1: Patch cords with EN 60793-2-50 single mode category B1.1 and B1.3 fibre for category C
This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an assembled singlemode patch cord with cylindrical ferruled connectors shall meet in order for it to be categorised as an EN standard product.
Since different variants and grades of performance are permitted, product marking details are given in 3.4 and Clause 4.
Steckverbindersätze und Verbindungsbauelemente für Lichtwellenleiter-Datenübertragungssysteme - Produktnormen - Teil 14-1: Verbindungskabel für Einmodenfasern der Kategorien B1.1 und B1.3 nach IEC 60793-2-50 für die Kategorie C
Konektorski sestavi in povezovalne komponente za optične komunikacijske sisteme - Specifikacija izdelka - 14-1. del: Povezovalne vrvice z enorodnim optičnim vlaknom po EN 60793-2-50 kategorij B1.1 in B1.3 za kategorijo C
General Information
- Status
- Not Published
- Public Enquiry End Date
- 31-Mar-2009
- Technical Committee
- MOC - Mobile Communications
- Current Stage
- 98 - Abandoned project (Adopted Project)
- Start Date
- 28-Oct-2010
- Due Date
- 02-Nov-2010
- Completion Date
- 28-Oct-2010
Overview
oSIST prEN 50377-14-1:2009 is a draft European standard developed by SIST for connector sets and interconnect components used in optical fibre communication systems. Specifically, this standard covers the product specifications for patch cords assembled with EN 60793-2-50 single mode category B1.1 and B1.3 fibre for category C applications (controlled environments). The document defines the dimensional, optical, mechanical, and environmental performance requirements needed for these patch cords to be classified as EN standard-compliant products.
Patch cords specified in prEN 50377-14-1 are used for connecting fibre optic devices and are critical for ensuring low-loss and reliable optical connections within structured cabling, data centers, and telecom networks. This standard ensures compatibility and intermateability, supporting consistent performance regardless of the manufacturing source.
Key Topics
Scope and Purpose
- Applies to single mode optical fibre patch cords using EN 60793-2-50 category B1.1 and B1.3 fibres.
- Specifies criteria for start-of-life performance regarding dimensions, optical attenuation, return loss, mechanical strength, and environmental endurance.
Performance Requirements
- Optical Performance:
- Categorizes attenuation grades (e.g., Grade B ≤ 0.12 dB mean, ≤ 0.25 dB for 97% of connections; Grade C ≤ 0.25 dB mean, ≤ 0.50 dB for 97%).
- Return loss criteria (Grade 1 ≥ 60 dB, Grade 2 ≥ 45 dB).
- Mechanical Performance:
- Requirements for tensile strength, flexing, side loads, ferrule compression, and cable bend resilience.
- Environmental Performance:
- Stability of attenuation and return loss under defined temperature cycling conditions.
- Optical Performance:
Variants and Marking
- Supports different connector types (SC, FC, LC, MU, LX.5, etc.), attenuation grades, return loss grades, cable structure, and lengths.
- Specifies detailed product marking for traceability and variant identification.
Testing and Conformance
- Outlines rigorous test sequences for dimensional, optical, mechanical, and environmental parameters.
- Specifies test sample sizes and procedures for qualification and quality assurance, referencing relevant EN and IEC standards.
Applications
- Telecommunications and Data Networks
- Patch cords compliant with oSIST prEN 50377-14-1 deliver reliable, low-attenuation optical connections in backbone cabling, telecom exchanges, and LANs.
- Data Centers
- Used in high-density optical distribution frames, cross-connections, and structured cabling systems, ensuring repeatable optical performance in controlled environments.
- Equipment Interconnection
- Ideal for connecting fibre optic transceivers, switches, and patch panels.
- Work Area Connectivity
- Robust, optionally ruggedized variants serve as work area cords for connecting end-devices in less-protected locations.
Related Standards
oSIST prEN 50377-14-1:2009 references and aligns with several key European and international standards to assure product performance and compatibility:
- EN 50377 series: Connector sets and interconnect components for optical fibre communication systems.
- EN 60793-2-50: Product specifications for class B single mode optical fibres.
- EN 60794-2-50: Indoor fibre cables for terminated cable assemblies.
- EN 61300 series: Basic test and measurement procedures for fibre optic devices.
- EN 61753-1: General guidance for performance standards in fibre optic interconnecting devices.
- EN 61755-1: Optical interfaces for single mode non-dispersion shifted fibres.
- ETSI TS 100 671: Passive optical components - Optical fibre connectors for single mode systems; common requirements.
Practical Value
Adhering to oSIST prEN 50377-14-1:2009 guarantees that optical fibre patch cords offer reliable low-loss connections, robust mechanical properties, and repeatable performance across different suppliers. This standardization facilitates interoperability, supports network scalability, and helps assure the quality and longevity of fibre optic installations in critical communication infrastructure.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.
LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
oSIST prEN 50377-14-1:2009 is a draft published by the Slovenian Institute for Standardization (SIST). Its full title is "Connector sets and interconnect components to be used in optical fibre communication systems - Product specifications - Part 14-1: Patch cords with EN 60793-2-50 single mode category B1.1 and B1.3 fibre for category C". This standard covers: This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an assembled singlemode patch cord with cylindrical ferruled connectors shall meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in 3.4 and Clause 4.
This standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements that an assembled singlemode patch cord with cylindrical ferruled connectors shall meet in order for it to be categorised as an EN standard product. Since different variants and grades of performance are permitted, product marking details are given in 3.4 and Clause 4.
oSIST prEN 50377-14-1:2009 is classified under the following ICS (International Classification for Standards) categories: 33.180.20 - Fibre optic interconnecting devices. The ICS classification helps identify the subject area and facilitates finding related standards.
oSIST prEN 50377-14-1:2009 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-januar-2009
.RQHNWRUVNLVHVWDYLLQSRYH]RYDOQHNRPSRQHQWH]DRSWLþQHNRPXQLNDFLMVNH
VLVWHPH6SHFLILNDFLMDL]GHONDGHO3RYH]RYDOQHYUYLFH]HQRURGQLP
RSWLþQLPYODNQRPSR(1NDWHJRULM%LQ%]DNDWHJRULMR&
Connector sets and interconnect components to be used in optical fibre communication
systems - Product specifications - Part 14-1: Patch cords with EN 60793-2-50 single
mode category B1.1 and B1.3 fibre for category C
Ta slovenski standard je istoveten z: prEN 50377-14-1:2008
ICS:
33.180.20 3RYH]RYDOQHQDSUDYH]D Fibre optic interconnecting
RSWLþQDYODNQD devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
DRAFT
EUROPEAN STANDARD
NORME EUROPÉENNE
November 2008
EUROPÄISCHE NORM
ICS
English version
Connector sets and interconnect components to be used in optical fibre
communication systems - Product specifications -
Part 14-1: Patch cords with EN 60793-2-50 single mode category B1.1 and
B1.3 fibre for category C
To be completed To be completed
This draft European Standard is submitted to CENELEC members for CENELEC enquiry.
Deadline for CENELEC: 2009-04-10.
It has been drawn up by CLC/TC 86BXA.
If this draft becomes a European Standard, CENELEC members are bound to comply with the CEN/CENELEC
Internal Regulations which stipulate the conditions for giving this European Standard the status of a national
standard without any alteration.
This draft European Standard was established by CENELEC in three official versions (English, French, German).
A version in any other language made by translation under the responsibility of a CENELEC member into its own
language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the
Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia,
Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
Sweden, Switzerland and the United Kingdom.
Warning : This document is not a European Standard. It is distributed for review and comments. It is subject to
change without notice and shall not be referred to as a European Standard.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Project: 15519 Ref. No. prEN 50377-14-1:2008 E
Draft for Enquiry
1 Foreword
2 This draft European Standard was prepared by the Technical Committee CENELEC TC 86BXA, Fibre optic
3 interconnect, passive and connectorised components. It is submitted to the CENELEC enquiry.
4 This document is updated to include the performance of the patch cord. It also includes latest attenuation and
5 return loss grades as specified in IEC.
6 __________
Draft for Enquiry
– 3 – prEN 50377-14-1:2008
Connector sets and interconnect components to be used in optical fibre communication systems –
Product specifications
Part 14-1: Patch cords with EN 60793-2-50 single mode category B1.1 and B1.3 fibre for category C
Description Performance
Fibre category: EN 60793-2-50 Application: For use in EN Category C
Types B1.1 and B1.3 (controlled environment)
Cable type: EN 60794-2-50 Attenuation grades: B: ≤ 0,12 dB mean
Type simplex cables (random mate)
≤ 0,25 dB for ≥ 97 %
of measurements
C: ≤ 0,25 dB mean
≤ 0,50 dB for ≥ 97 %
of measurements
Return loss grade: 1: ≥ 60 dB
(random mate) 2: ≥ 45 dB
Related documents:
EN 50377 series Connector sets and interconnect components to be used in optical fibre
communication systems – Product specifications
EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres (IEC 60793-2-50)
EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor optical fibre cables – Family specification for
simplex and duplex cables for use in terminated cable assemblies (IEC 60794-2-50)
EN 61300 series Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures (IEC 61300 series)
EN 61753-1 Fibre optic interconnecting devices and passive components performance standard –
Part 1: General and guidance for performance standards (IEC 61753-1)
ETSI TS 100 671 Transmission and Multiplexing (TM); Passive optical components; Optical fibre
connectors for single mode optical fibre communication systems; Common
requirements and conformance testing
Outline and maximum dimensions:
Length
Draft for Enquiry
8 Contents
9 1 Scope . 5
10 1.1 Product definition . 5
11 1.2 Intermateability of the plugs . 5
12 1.3 Operating environment . 5
13 1.4 Reliability . 5
14 1.5 Quality assurance . 5
15 2 Normative references . 6
16 3 Description . 6
17 3.1 Plug . 7
18 3.2 Materials . 7
19 3.3 Marking . 7
20 4 Variants . 8
21 5 Dimensional requirements . 9
22 5.1 Outline dimensions . 9
23 6 Tests . 9
24 6.1 Sample size . 9
25 6.2 Test and measurement methods . 9
26 6.3 Test sequence . 9
27 6.4 Pass/fail criteria . 9
28 7 Test report . 9
29 8 Product qualification requirements . 10
30 8.1 Dimensional and marking requirements. 10
31 8.2 Optical performance requirements . 10
32 8.3 Mechanical performance requirements . 12
33 8.4 Environmental performance requirements . 14
34 Annex A (informative) Reference connector details . 15
35 Annex B (normative) Tests, sample size and product sourcing requirements . 16
36 Annex C (normative) Cable bend (coiling) test procedure . 17
37 Bibliography . 18
38 Figures
39 Figure 1 – Length of patch cord . 9
40 Figure 2 – Cable bend (coiling) test set-up . 17
41 Tables
42 Table 1 – Ensured level of random attenuation . 5
43 Table 2 – Connector and Adaptor references. 7
44 Table 3 – Optical performance requirements . 11
45 Table 4 – Mechanical performance requirements . 12
46 Table 5 – Environmental performance requirements . 14
47 Table B.1 – Test, sample size and sourcing . 16
Draft for Enquiry
– 5 – prEN 50377-14-1:2008
49 1 Scope
50 1.1 Product definition
51 This standard contains the initial, start of life dimensional, optical, mechanical and environmental
52 performance requirements which an assembled single-mode patch cord must meet in order for it to be
53 categorised as an EN standard product.
54 Since different variants and grades of performance are permitted, product marking details are given in 3.5
55 and Clause 4.
56 1.2 Intermateability of the plugs
57 Although all products conforming to the requirements of this standard will intermate, the resulting level of
58 random attenuation performance will only be ensured in accordance with Table 1. The intention is that this
59 will be true irrespective of the manufacturing source(s) of the product.
60 When intermating plug variants having different attenuation grades as specified in EN 61755-1, the resulting
61 level of attenuation cannot be assured to be any better than the worst attenuation grade.
62 The intermating of a grade C plug with a grade B plug will result in a grade C level of random attenuation
63 performance.
64 Table 1 – Ensured level of random attenuation
Plug variant / Plug 2
Attenuation grade
C B
C C C
Plug 1
B C B
66 1.3 Operating environment
67 The tests selected combined with the severities and durations are representative of an EN 61753-1
68 Category C environment.
69 1.4 Reliability
70 Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with
71 this standard does not guarantee the reliability of the product. This should be predicted using a recognised
72 reliability assessment programme.
73 1.5 Quality assurance
74 Compliance with this standard does not guarantee the manufacturing consistency of the product. This should
75 be maintained using a recognised quality assurance programme.
Draft for Enquiry
76 2 Normative references
77 The following referenced documents are indispensable for the application of this document. For dated
78 references, only the edition cited applies. For undated references, the latest edition of the referenced
79 document (including any amendments) applies.
EN 50377 series Connector sets and interconnect components to be used in optical fibre
communication systems – Product specifications
EN 60793-2-50 Optical fibres – Part 2-50: Product specifications – Sectional specification for
class B single-mode fibres (IEC 60793-2-50)
EN 60794-2-50 Optical fibre cables – Part 2-50: Indoor optical fibre cables – Family specification
for simplex and duplex cables for use in terminated cable assemblies
(IEC 60794-2-50)
EN 61300-2-4 Part 2-4: Tests – Fibre/cable retention (IEC 61300-2-4)
EN 61300-2-22 Part 2-22: Tests – Change of temperature (IEC 61300-2-22)
EN 61300-2-42 Part 2-42: Tests – Static side load for connectors (IEC 61300-2-42)
EN 61300-2-44 Part 2-44: Tests – Flexing of the strain relief of fibre optic devices
(IEC 61300-2-44)
EN 61300-3-3 Part 3-3: Examinations and measurements – Active monitoring of changes in
attenuation and return loss (IEC 61300-3-3)
EN 61300-3-6:2003 Part 3-6: Examinations and measurements – Return loss (IEC 61300-3-6:2003)
EN 61300-3-22 Part 3-22: Examinations and measurements – Ferrule compression force
(IEC 61300-3-22)
EN 61300-3-28 Part 3-28: Examinations and measurements – Transient loss (IEC 61300-3-28)
EN 61300-3-34:2002 Part 3-34: Examinations and measurements – Attenuation of random mated
connectors (IEC 61300-3-34:2001)
EN 61753-1 Fibre optic interconnecting devices and passive components performance standard –
Part 1: General and guidance for performance standards (IEC 61753-1)
EN 61755-1 Fibre optic connector optical interfaces – Part 1: Optical interfaces for single mode non-
dispersion shifted fibres – General and guidance (IEC 61755-1)
80 3 Description
81 For the purpose of this document a patch cord is defined as a short length of cable with connector plugs
82 assembled at both cable ends. Typical length (but not limited to) is 1 m to 10 m, measured from tip to tip at
83 the extremes. Patch cords are installed in mechanical protected locations (inside cabinets, distribution
84 frames and enclosures).
85 The document also applies to work area cords which are typically more ruggedised (larger diameter) and
86 used in mechanical less protected locations. For the purpose of this document both patch cords and work
87 area cords are called patch cords.
Draft for Enquiry
– 7 – prEN 50377-14-1:2008
88 3.1 Plug
89 The plug features a cylindrical ferrule. It has a single male key which is used to limit and may be used to
90 orientate, the relative rotation between mated connectors.
91 A cover (dust cap) to protect the ferrule end faces when the connectors are in the unmated condition shall be
92 provided.
93 The plug shall meet the relevant product specification as listed in Table 2.
94 Table 2 – Connector and Adaptor references
Connector or adaptor Reference
FC EN 50377-2 series
SC EN 50377-4 series
SC-RJ EN 50377-6 series
LC EN 50377-7 series
LSH EN 50377-8-series
MU EN 50377-10 series
LX.5 EN 50377-13 series
96 3.2 Materials
97 Materials which are not specified or which are not specifically described are left to the discretion of the
98 manufacturer.
99 T
...