OSIST prEN ISO 10524-1:2004
(Main)Pressure regulators for use with medical gas systems -- Part 1: Pressure regulators and pressure regulators with flow-metering devices
Pressure regulators for use with medical gas systems -- Part 1: Pressure regulators and pressure regulators with flow-metering devices
See WI 00215129
Druckminderer zur Verwendung mit medizinischen Gasen - Teil 1: Druckminderer und Druckminderer mit Durchflussmessgeräten (ISO 10524-1:2006)
Détendeurs pour l'utilisation avec les gaz médicaux - Partie 1: Détendeurs et détendeurs-débimètres (ISO 10524-1:2006)
Pressure regulators for use with medical gas - Part 1: Pressure regulators and pressure regulators with flow-metering devices
General Information
Relations
This May Also Interest You
This document specifies design, construction, type testing, and marking requirements for manifold
pressure regulators (as defined in 3.7) and line pressure regulators (as defined in 3.5) intended
for use in medical gas pipeline systems.
Examples of gases include oxygen, medical air and oxygen/nitrous oxide mixtures.
This document applies to manifold pressure regulators and line pressure regulators supplied
as individual units or to the relevant components incorporated within an assembly.
Manifold pressure regulators are intended to be connected to a manifold system which has a
nominal inlet pressure, P1 of up to 30 000 kPa (300 bar).
Line pressure regulators are intended to be connected downstream of the manifold pressure
regulator with a supply pressure up to 3 000 kPa (30 bar).
This document does not apply to pressure regulators for use with vacuum pipeline systems.
NOTE Requirements for pressure regulators for use with vacuum pipeline systems are covered in
ISO 10079-3.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies design, type testing, and marking requirements for cylinder valves with
integrated pressure regulators [as defined in 3.26 and referred to hereafter as valves with
integrated pressure regulators (VIPRs)] intended for the administration of medical gases in
the treatment, management, diagnostic evaluation and care of patients or for gases used for driving
surgical tools.
Examples of gases include oxygen, medical air and oxygen/nitrous oxide mixtures.
This document applies to VIPRs mounted on refillable cylinders with a working pressure up to
30 000 kPa (300 bar) intended to be filled in cylinder filling facilities or on self-filling systems as used
in homecare applications.
VIPRs covered by this document are pressure pre-set and provided with a pressure outlet and/or
pre-set flow outlet(s).
- Standard52 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft49 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the design, construction, type testing, and marking requirements for pressure
regulators (as defined in 3.18) intended for the administration of medical gases and their mixtures
in the treatment, management, diagnostic evaluation and care of patients or for gases used for driving
surgical tools.
Examples of gases include oxygen, medical air and oxygen/nitrous oxide mixtures.
This document applies to pressure regulators:
a) intended to be connected to cylinders by the operator;
b) with integral flow-metering devices intended to be connected to cylinders by the operator;
c) that are an integral part of medical equipment (e.g. anaesthetic workstations, lung ventilators,
resuscitators).
A pressure regulator can be provided with pressure outlet or flow outlet, and can be adjustable
or pre-set.
pressure regulators are intended to be fitted to refillable cylinders with a working pressure up
to 30 000 kPa ( 300 bar) and can be provided with devices which control and measure the flow of the
medical gas delivered.
- Standard42 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft43 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of ISO 10524 applies to the types of low-pressure regulators listed in 1.2 and intended to be used with the following medical gases in the treatment, management, diagnostic evaluation and care of patients: - oxygen; - nitrous oxide; - medical air; - helium; - carbon dioxide; - xenon; - specified mixtures of the gases listed above; - air for driving surgical tools; - nitrogen for driving surgical tools; - oxygen-enriched air. The types of low-pressure regulators covered by this part of ISO 10524 are as follows: a) low-pressure regulators intended to be connected to terminal units of medical gas pipeline systems complying with ISO 7396-1; b) low-pressure regulators with integral flow-metering devices intended to be connected to terminal units of complying with ISO 7396-1; b) low-pressure regulators with integral flow-metering devices intended to be connected to terminal units of medical gas pipeline systems complying with ISO 7396-1; c) low-pressure regulators intended to be connected to terminal units attached to pressure regulators complying with ISO 10524-1 or ISO 10524-3; d) operator-adjustable low-pressure regulators for air or nitrogen for driving surgical tools that are an integral part of a medical gas pipeline system complying with ISO 7396-1.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft4 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to pin-index yoke-type valve connections for medical gas cylinders, with a working pressure up to a maximum of 200 bar or test pressure up to a maximum of 300 bar, or both.
NOTE 1 This type of connection is primarily used for small cylinders (5 l or below).
NOTE 2 In this document the unit bar is used, due to its universal use in the field of technical gases. It should, however, be noted that bar is not an SI unit, and that the corresponding SI unit for pressure is Pa (1 bar = 105 Pa = 105 N/m2).
This document specifies:
— basic dimensions;
— requirements for alternative designs of the yoke-type valve connections;
— dimensions and positions for the holes and pins for the outlet connections.
It also specifies the dimensions and positions for the holes and pins for the outlet connections for gases and gas mixtures.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft23 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies the design, construction, type testing, and marking requirements for pressure
regulators (as defined in 3.18) intended for the administration of medical gases and their mixtures
in the treatment, management, diagnostic evaluation and care of patients or for gases used for driving
surgical tools.
Examples of gases include oxygen, medical air and oxygen/nitrous oxide mixtures.
This document applies to pressure regulators:
a) intended to be connected to cylinders by the operator;
b) with integral flow-metering devices intended to be connected to cylinders by the operator;
c) that are an integral part of medical equipment (e.g. anaesthetic workstations, lung ventilators,
resuscitators).
A pressure regulator can be provided with pressure outlet or flow outlet, and can be adjustable
or pre-set.
pressure regulators are intended to be fitted to refillable cylinders with a working pressure up
to 30 000 kPa ( 300 bar) and can be provided with devices which control and measure the flow of the
medical gas delivered.
- Standard42 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft43 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies design, type testing, and marking requirements for cylinder valves with
integrated pressure regulators [as defined in 3.26 and referred to hereafter as valves with
integrated pressure regulators (VIPRs)] intended for the administration of medical gases in
the treatment, management, diagnostic evaluation and care of patients or for gases used for driving
surgical tools.
Examples of gases include oxygen, medical air and oxygen/nitrous oxide mixtures.
This document applies to VIPRs mounted on refillable cylinders with a working pressure up to
30 000 kPa (300 bar) intended to be filled in cylinder filling facilities or on self-filling systems as used
in homecare applications.
VIPRs covered by this document are pressure pre-set and provided with a pressure outlet and/or
pre-set flow outlet(s).
- Standard52 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft49 pagesEnglish languagesale 10% offe-Library read for×1 day
This document specifies design, construction, type testing, and marking requirements for manifold
pressure regulators (as defined in 3.7) and line pressure regulators (as defined in 3.5) intended
for use in medical gas pipeline systems.
Examples of gases include oxygen, medical air and oxygen/nitrous oxide mixtures.
This document applies to manifold pressure regulators and line pressure regulators supplied
as individual units or to the relevant components incorporated within an assembly.
Manifold pressure regulators are intended to be connected to a manifold system which has a
nominal inlet pressure, P1 of up to 30 000 kPa (300 bar).
Line pressure regulators are intended to be connected downstream of the manifold pressure
regulator with a supply pressure up to 3 000 kPa (30 bar).
This document does not apply to pressure regulators for use with vacuum pipeline systems.
NOTE Requirements for pressure regulators for use with vacuum pipeline systems are covered in
ISO 10079-3.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
This part of ISO 10524 applies to the types of low-pressure regulators listed in 1.2 and intended to be used with the following medical gases in the treatment, management, diagnostic evaluation and care of patients: - oxygen; - nitrous oxide; - medical air; - helium; - carbon dioxide; - xenon; - specified mixtures of the gases listed above; - air for driving surgical tools; - nitrogen for driving surgical tools; - oxygen-enriched air. The types of low-pressure regulators covered by this part of ISO 10524 are as follows: a) low-pressure regulators intended to be connected to terminal units of medical gas pipeline systems complying with ISO 7396-1; b) low-pressure regulators with integral flow-metering devices intended to be connected to terminal units of complying with ISO 7396-1; b) low-pressure regulators with integral flow-metering devices intended to be connected to terminal units of medical gas pipeline systems complying with ISO 7396-1; c) low-pressure regulators intended to be connected to terminal units attached to pressure regulators complying with ISO 10524-1 or ISO 10524-3; d) operator-adjustable low-pressure regulators for air or nitrogen for driving surgical tools that are an integral part of a medical gas pipeline system complying with ISO 7396-1.
- Standard40 pagesEnglish languagesale 10% offe-Library read for×1 day
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.