SIST EN IEC/IEEE 65700:2018/AC:2019
(Corrigendum)Bushings for DC application
Bushings for DC application
CCMC - wrong standard reference to be corrected
Durchführungen für Gleichspannungsanwendungen
Traversées pour application en courant continu
Skoznjiki za enosmerne aplikacije
General Information
Relations
Standards Content (Sample)
SLOVENSKI STANDARD
SIST EN IEC/IEEE 65700:2018/AC:2019
01-junij-2019
Skoznjiki za enosmerne aplikacije
Bushings for DC application
Durchführungen für Gleichspannungsanwendungen
Traversées pour application en courant continu
Ta slovenski standard je istoveten z: EN IEC/IEEE 65700-19-03:2018/AC:2019-03
ICS:
29.080.20 Skoznjiki Bushings
SIST EN IEC/IEEE 65700:2018/AC:2019 en,fr,de
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
---
...
This May Also Interest You
This document is applicable to ceramic insulated outdoor bushings for highest voltages for equipment of 24 kV and 36 kV, with rated currents of 5 kA and 8 kA for insulating liquid filled transformers and frequencies from 15 Hz up to 60 Hz.
This document establishes dimensions to ensure interchangeability and adequate mounting of bushings.
Two types of construction are specified, type A and type B, both types for highest voltages for equipment 24 kV and 36 kV and rated currents of 5 kA and 8 kA. The mechanical stresses of the conductor tube define the difference between type A and type B. The conductor tube of type A is axially and radially fixed in the top of the bushing. The inner line terminal of the transformer can be flexible and without any special support for the lower end of the conductor tube.
For new installations bushings of Type A are expected to be used. Type B bushings can be supplied at the request of a customer.
In case of type B, the conductor tube is only radially fixed in the top of the bushing. In that case, a rigid support is mounted to fix the lower end of the conductor tube (for example, in combination with a drip proofed sealing end). The drip proofed sealing end is often required in the service requirements. In this case, it is not possible to use type A because of the existing double fixation. Therefore, both bushing types A and B are be specified.
The condition for the usage of type B is that the drip-proof sealing end is able to withstand the mechanical stress in axial direction.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft26 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to insulated bushings, excluding those plug-in bushings specified by EN 50180 series, for use in air insulated, shroud insulated and fully insulated cable boxes for liquid filled transformers and reactors for rated voltages up to 36 kV, and rated currents up to 4 000 A at frequencies from 15 Hz to 60 Hz.
- Standard17 pagesEnglish languagesale 10% offe-Library read for×1 day
- Draft17 pagesEnglish languagesale 10% offe-Library read for×1 day
This document is applicable to plug-in type bushings, according to EN 60137, 72,5 kV, rated currents
from 630 A up to 1 250 A and frequencies from 15 Hz up to 60 Hz for single or three-phase arrangements in electrical equipment like liquid filled transformers or gas insulated switchgear and controlgear. It complements and amends, if necessary, the relevant EN standards.
The application of such plug-in type bushings is derived from EN 50180 and EN 50181 but applied for higher voltages with described deviations to EN 50299-2 and EN 62271-209.
This standard does not cover the connection assembly as described in EN 50299-2 and EN 62271-209.
EN 60137 and HD 632 series outline the qualification, type test, routine and sample test of plug-in type bushings according to this standard.
This document establishes essential dimensions and testing procedures, to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings.
- Standard14 pagesEnglish languagesale 10% offe-Library read for×1 day
IEC - Corrected version
- Corrigendum3 pagesEnglish and French languagesale 10% offe-Library read for×1 day
This International Standard applies to outdoor and indoor bushings of any voltage used on DC
systems, of capacitance graded or gas insulated types for use as components of oil-filled
converter transformers and smoothing reactors, as well as air-to-air DC bushings. This
standard does not apply to the following:
• cable terminations (potheads);
• bushings for instrument transformers;
• bushings for test power supplies;
• bushings applied with gaseous insulation (other than air at atmospheric pressure) external
to the bushing;
• bushings for industrial application;
• bushings for traction application;
• bushings for distribution class transformers.
This standard makes reference to IEC 60137 for general terms and conditions and defines the
special terms used, operating conditions, ratings, test procedures as well as general
mechanical and electrical requirements for bushings for DC application.
- Standard56 pagesEnglish languagesale 10% offe-Library read for×1 day
This International Standard specifies the characteristics and tests for insulated bushings.
This standard is applicable to bushings, as defined in Clause 3, intended for use in electrical
apparatus, machinery, transformers, switchgear and installations for three-phase alternating
current systems, having highest voltage for equipment above 1 000 V and power frequencies
of 15 Hz up to and including 60 Hz.
Subject to special agreement between purchaser and supplier, this standard may be applied,
in part or as a whole, to the following:
• bushings used in other than three-phase systems;
• bushings for high-voltage direct current systems;
• bushings for testing transformers;
• bushings for capacitors.
Special requirements and tests for transformer bushings in this standard apply also to reactor
bushings.
This standard is applicable to bushings made and sold separately. Bushings which are a part
of an apparatus and which cannot be tested according to this standard should be tested with
the apparatus of which they form part.
- Standard64 pagesEnglish languagesale 10% offe-Library read for×1 day
Integrate the not accepted changes of the work of WG1 proposed in the meeting on 23th October 2014 in EN50180-3
- Amendment5 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard should be considered in factual context with EN 50180-1 only. The dimensional
supplements are related to figures and tables of EN 50180-1. To enable a better understanding of additional
information some tables from EN 50180-1 are used and extended.
This European Standard may now be used also for bushings with a highest voltage of 52 kV. Figures for the
details of the components and the related tables are added according to the extended range of voltage.
- Standard26 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard is applicable to ceramic and resin insulated bushings having highest voltages above 1 kV up to 52 kV, rated currents from 250 A up to 3 150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers.
This European Standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure adequate mounting and interchangeability of mating plug-in separable connectors of equivalent ratings.
- Standard39 pagesEnglish languagesale 10% offe-Library read for×1 day
This European Standard should be considered in factual context with EN 50180-1 only. Constructional details
for fastenings and their details are supplementing EN 50180-1. This information is of importance for utilities
concerning compatibility.
For a better understanding of additional information some dimension from EN 50180-1 are repeated in this
European Standard.
This European Standard was extended for fastenings of bushings for a highest voltage of 52 kV.
- Standard11 pagesEnglish languagesale 10% offe-Library read for×1 day