SIST EN 301 126-3-2 V1.2.1:2003
(Main)Fixed Radio Systems; Conformance testing; Part 3-2: Point-to-Multipoint antennas - Definitions, general requirements and test procedures
- Abstract
Revision of conformance testing standard to include circularly polarised antennas : Coordination with the work under REN/TM-4144 should be maintained in order to synchronise the outputs (as far as possible)
- Status
- Published
- Publication Date
- 30-Nov-2003
- Current Stage
- 6060 - National Implementation/Publication (Adopted Project)
- Start Date
- 01-Dec-2003
- Due Date
- 01-Dec-2003
- Completion Date
- 01-Dec-2003
SIST EN 301 126-3-2 V1.2.1:2003 is the Slovenian adoption of the ETSI standard for Fixed Radio Systems conformance testing of point-to-multipoint (P-MP) antennas. It specifies definitions, general requirements and test procedures used for type approval of antenna-specific parameters, mainly for suppliers, accredited laboratories and type approval authorities.
What does SIST EN 301 126-3-2 V1.2.1:2003 specify?
SIST EN 301 126-3-2 V1.2.1:2003 specifies standardized conformance testing for antennas used in P-MP radio relay systems. It is written for approval testing of antenna parameters required by the relevant antenna standards, and it is intended to be used together with those individual antenna standards.
The document applies to separate antennas and to antennas that are partly or fully integrated with outdoor equipment. It also says that established products are outside its scope, and it notes that P-P antennas are covered by separate standards.
The document is organized into six clauses and four annexes.
| Annex | What it covers |
|---|---|
| Annex A | Supplier's Declaration template for the required antenna characteristics |
| Annex B | Test report template, including results, setup information and measurement accuracy |
| Annex C | Informative test site description and equipment listing guidance |
| Annex D | Bibliography |
What are the key requirements of SIST EN 301 126-3-2 V1.2.1:2003?
SIST EN 301 126-3-2 V1.2.1:2003 separates parameters into essential, complementary and optional requirements, and that distinction drives whether a parameter needs approval testing or only declaration. In practice, that tells a supplier or lab what must be measured, what may be declared, and what must appear in the test report.
Clause 4 sets the test basis and the status of each parameter
Clause 4 classifies the antenna parameters for conformance testing and links them to test conditions and methods. The table in 4.1 shows which items are essential requirements, which are complementary or optional, and which need a supplier declaration.
This matters because not every antenna characteristic is treated the same way. A buyer, manufacturer or lab can use the classification to see whether a parameter is part of approval testing, a declared option, or supporting information.
The Implementation Under Test must represent a production model
Clause 4.2 says the Implementation Under Test (IUT) must be representative of a production model. The document applies to both integrated and non-integrated antennas, and if the antenna is separate from the radio equipment, the test is performed at the accessible antenna port.
This matters because the measured antenna has to reflect the real product that will be shipped. If adapters are needed, their effect has to be taken into account and declared, so the results stay traceable to the actual installation.
The supplier has to declare the operating envelope and construction details
Clause 5 requires a Supplier's Declaration (SD) covering frequency range, frequency band, class of antenna RPE, sector angle or beam directions, gain, environmental characteristics, antenna stability, input connector type, RL/VSWR, inter-port isolation and polarization. Annex A provides the declaration template for both essential and complementary or optional parameters.
In practice, this is the document that tells the test house and the authority what the antenna is supposed to do. It also fixes the configuration being approved, which is important when a product family has several bands, beams or connector options.
Essential tests focus on Radiation Pattern Envelope and gain
Clause 6 makes the Radiation Pattern Envelope (RPE) and antenna gain the main essential requirements. The document says the methods generally follow IEC 60835-2-2, while allowing alternative methods if agreed in advance with the Type Approval Authority.
This matters because RPE and gain are the core performance checks for directional P-MP antennas. The antenna is measured at least at the lowest, middle and highest frequencies in the declared band, so the results cover the operating range rather than a single spot frequency.
Circularly polarised antennas are handled explicitly
Clause 6 states that linear antennas are measured with linearly polarised transmitting antennas, while circularly polarised antennas may be measured with circularly or linearly polarised transmitting antennas. If linear transmit antennas are used, the received signals may be combined mathematically to derive co-polar, cross-polar and gain results.
This is the part that makes the revision useful for circularly polarised designs. It gives a practical route for measuring them without changing the overall approval structure.
RPE and gain measurements use defined alignments and repeat frequencies
For RPE, the antenna is aligned at the centre frequency, the co-polar and cross-polar patterns are recorded, and the measurements are repeated at the band limits while keeping the original mechanical alignment. For multi-beam antennas, the procedure is repeated for each beam.
For gain, the document allows comparison, three-antenna and direct methods, and the measured gain is used to normalize the RPE. In practice, that means the lab must not only measure gain but also use it to relate the pattern to the declared reference direction.
The test report has to document method, conditions and accuracy
Annex B requires a structured test report with a summary of compliance, general test information, pattern plots, gain results, environmental conditions and measurement accuracy. The report also has to identify the method used and record any effect from reflections or interference.
This matters because antenna testing is sensitive to the test site and setup. Clause B.1.4 and Annex C make it clear that the report has to show how the environment, equipment and uncertainty were controlled.
What terms does SIST EN 301 126-3-2 V1.2.1:2003 define?
- Implementation Under Test (IUT) - the representative sample of the equipment or antenna that is submitted for testing.
- Radiation Pattern Envelope (RPE) - the limit envelope within which the measured radiation pattern must fit.
- Supplier's Declaration (SD) - the supplier's written assurance that a parameter or function conforms to the standard.
- Type approval authority - the national regulatory or licensing authority responsible for approval.
- Inter-port isolation - the ratio between power applied to one port of a multi-port antenna and power received at another port.
- Integrated antenna - an antenna that forms part of the enclosure or is contained within the product enclosure.
Who uses SIST EN 301 126-3-2 V1.2.1:2003?
This standard is used by manufacturers and suppliers of P-MP antennas, especially for Central Station (CS), Repeater Station (RS) and Terminal Station (TS) applications. It is also used by accredited test laboratories that perform type approval testing of antenna patterns, gain and related characteristics.
Type approval authorities use it to evaluate declarations and test reports for regulatory approval. Quality managers and procurement teams use it to compare antenna classes, bands, gain, polarization, connector type and environmental ratings before acceptance.
What changed in SIST EN 301 126-3-2 V1.2.1:2003 from the previous edition?
SIST EN 301 126-3-2 V1.2.1:2003 replaces V1.1.1. The scope says the revision updates the conformance testing standard to include circularly polarised antennas and that coordination with work under REN/TM-4144 should be maintained as far as possible.
Which standards are used with SIST EN 301 126-3-2 V1.2.1:2003?
| Reference | What it contributes |
|---|---|
| ETSI EN 301 525 | P-MP antennas in the 1 GHz to 3 GHz band |
| ETSI EN 302 085 | P-MP antennas in the 3 GHz to 11 GHz band |
| ETSI EN 301 215 series | P-MP antennas in the 11 GHz to 60 GHz band |
| ETSI EN 300 631 | P-P antennas in the 1 GHz to 3 GHz band |
| ETSI EN 300 833 | P-P antennas in the 3 GHz to 60 GHz band and guidance on test sites |
| ETSI EN 301 126-3-1 | Point-to-Point antennas conformance testing companion part |
| ISO/IEC 17025 | Laboratory competence for testing and calibration |
| ISO/IEC Guide 28 | Model third-party certification system for products |
| EN 45002 | Criteria for assessing testing laboratories |
| ISO 9001 (1994) | Evidence of a quality system |
| IEC 60835-2-2 (1994) | General measurement methods for terrestrial radio-relay antennas |
| ISO/IEC 15485 (1997) | One of the cited references for connector-related declaration text |
| IEC 60169 series | Radio-frequency connectors |
What does the SIST EN 301 126-3-2 V1.2.1:2003 document contain?
The document contains the clause structure for scope, references, definitions, conformance requirements, supplier declaration and test procedures. It also includes a classification table that links antenna parameters to essential, complementary and optional status.
Annex A provides a declaration form that covers operating band, gain, polarization, environmental ratings and connector details. Annex B provides the test report forms, including separate plots for azimuth and elevation, co-polar and cross-polar patterns, plus gain results at the low, middle and high points of the band.
Annex B also covers environmental conditions during testing and measurement accuracy, including the effect of reflections and interference. Annex C gives guidance for describing the test site and listing the equipment used, which helps traceability and repeatability.
Get Certified
Connect with accredited certification bodies for this standard

ANCE
Mexican certification and testing association.

Intertek Slovenia
Intertek testing, inspection, and certification services in Slovenia.

LNE (Laboratoire National de Métrologie et d'Essais)
French national laboratory for metrology and testing.
Sponsored listings
Frequently Asked Questions
SIST EN 301 126-3-2 V1.2.1:2003 is a standard published by the Slovenian Institute for Standardization (SIST). Its full title is "Fixed Radio Systems; Conformance testing; Part 3-2: Point-to-Multipoint antennas - Definitions, general requirements and test procedures". This standard covers: Revision of conformance testing standard to include circularly polarised antennas : Coordination with the work under REN/TM-4144 should be maintained in order to synchronise the outputs (as far as possible)
Revision of conformance testing standard to include circularly polarised antennas : Coordination with the work under REN/TM-4144 should be maintained in order to synchronise the outputs (as far as possible)
SIST EN 301 126-3-2 V1.2.1:2003 is classified under the following ICS (International Classification for Standards) categories: 33.060.30 - Radio relay and fixed satellite communications systems; 33.120.40 - Aerials. The ICS classification helps identify the subject area and facilitates finding related standards.
SIST EN 301 126-3-2 V1.2.1:2003 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- 1 Scope
- 2 References
- 7 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 3 Definitions, symbols and abbreviations
- 3.1 Definitions
- 8 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 9 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 3.2 Symbols
- 3.3 Abbreviations
- 10 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 4 Requirements related to antennas conformance test
- 4.1 General requirements
- 11 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 4.2 Implementation under test (IUT)
- 12 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 5 Supplier's Declaration
- 5.1 General characteristics
- 13 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 6 Test procedures for essential requirements
- 6.1 Radiation Pattern Envelope (RPE)
- 14 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 15 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 6.2 Antenna gain
- 16 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 17 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 6.3 Other antenna characteristics
- 18 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 19 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 20 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 21 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 22 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 23 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 24 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 25 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 26 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 27 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 1 Radio link 23 km
- 2 Reflection Tree 120 m
- 28 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- 29 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
- Bibliography
- 30 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
1 Scope
The present document details standardized procedures for conformance testing of antennas for Point-to-MultiPoint radio relay systems [1], [2] and [3] in order to achieve the approval by the Type Approval Authority. The procedure for dealing with established products is outside the scope of the present document. The present document is intended to be applied in conjunction with the individual antenna standards and will enable commonality in the presentation of test results, irrespective of the Suppliers/accredited laboratory carrying out the test. The conformance tests described in the present document are related to antenna specific parameters required directly by the relevant antenna standards [1], [2] and [3].
The present document applies to both those antennas that are separate and those that are in some manner partially or fully integrated with the outdoor equipment. In all cases, whilst facilitating access to the appropriate antenna port, testing shall preserve the electro-magnetic environment i.e. be representative of the outdoor unit enclosure / electronics used in the typical (manufacturers' recommended) configuration. This need to maintain consistency with the manufacturer's recommended configuration is particularly important for less directional antennas (commonly with less than 25 dBi gain, although this value will depend on the specific ETS/EN parameters for that class, type etc). It is noted that antennas intended for Point-to-Point (P-P) use are similarly the subjects of separate standards covering their characteristics and conformance testing [5], [6] and [7]. In some cases, particularly for the higher gains and frequencies, such P-P antennas may be appropriate for P-MP usage at the discretion of the regulatory authority. In such cases the regulatory authority will also define the applicable antenna and conformance-testing standard.
2 References
The following documents contain provisions which, through reference in this text, constitute provisions of the present document.
- References are either specific (identified by date of publication and/or edition number or version number) or non-specific.
- For a specific reference, subsequent revisions do not apply.
- For a non-specific reference, the latest version applies.
Referenced documents which are not found to be publicly available in the expected location might be found at http://docbox.etsi.org/Reference.
[1] ETSI EN 301 525: "Fixed Radio Systems; Point-to-Multipoint Antennas; Antennas for Point-to-Multipoint fixed radio systems in the 1 GHz to 3 GHz band". [2] ETSI EN 302 085: "Fixed Radio Systems; Point-to-Multipoint Antennas; Antennas for point-to-multipoint fixed radio systems in the 3 GHz to 11 GHz band". [3] ETSI EN 301 215 (series): "Fixed Radio Systems; Point-to-Multipoint Antennas; Antennas for point-to-multipoint fixed radio systems in the 11 GHz to 60 GHz band". [4] Void.
[5] ETSI EN 300 631: "Fixed Radio Systems; Point-to-Point Antennas; Antennas for point-to-point fixed radio systems in the 1 GHz to 3 GHz band".
[6] ETSI EN 300 833: "Fixed Radio Systems; Point-to-point antennas; Antennas for point-to-point fixed radio systems operating in the frequency band 3 GHz to 60 GHz". [7] ETSI EN 301 126-3-1: "Fixed Radio Systems; Conformance testing; Part 3-1: Point-to-Point antennas; Definitions, general requirements and test procedures". [8] ISO/IEC 17025: "General requirements for the competence of testing and calibration laboratories". ETSI
SIST EN 301 126-3-2 V1.2.1:2003
7 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
[9] ISO/IEC Guide 28: "General rules for a model third-party certification system for products". [10] Void.
[11] EN 45002: "General criteria for the assessment of testing laboratories". [12] ISO 9001 (1994): "Quality systems - Model for quality assurance in design, development, production, installation and servicing".
[13] IEC 60835-2-2 (1994): "Methods of measurement for equipment used in digital microwave transmission systems - Part 2: Measurements on terrestrial radio-relay systems - Section 2:
Antenna".
[14] ISO/IEC 15485 (1997): "Information technology - Data interchange on 120 mm optical disk cartridges using phase change PD format - Capacity: 650 Mbytes per cartridge". [15] IEC 60169 (series): "Radio-frequency connectors".
3 Definitions, symbols and abbreviations
3.1 Definitions
For the purposes of the present document, the following terms and definitions apply:
accreditation: formal recognition that a testing laboratory is competent to carry out specific tests or specific types of test accreditation body: body that conducts and administers a laboratory accreditation system and grants accreditation accreditation system: system that has its own rules of procedure and management for carrying out laboratory accreditation accredited laboratory: testing laboratory which accreditation has been granted in accordance with the ISO/IEC 17025 [8], ISO Guide 28 [9] and EN 45002 [11] antennas: that part of the transmitting or receiving system that is designed to radiate and/or receive electromagnetic waves approval testing: Approval testing is required for approval of the Implementation Under Test (IUT) by the appropriate authority for regulatory purposes. In this context approval implies that the IUT has met the essential requirements of the ETS/EN against which it has been tested.
axial ratio: the ratio of maximum to minimum power contained in the field components of the polarization ellipse boresight: the axis of the main beam in a directional antenna Central Station (CS): base station which communicates each way with many terminal stations and, in many cases, repeater stations complementary requirements: in an ETS/EN all those requirements not part of the essential requirements are complementary requirements conformance testing: the type testing process to verify to what extent the IUT conforms to the ETS/EN co-polar pattern: diagram representing the radiation pattern of a test antenna when the reference antenna is similarly polarized, scaled in dBi or dB relative to the measured antenna gain cross-polar pattern: diagram representing the radiation pattern of a test antenna when the reference antenna is orthogonally polarized, scaled in dBi, or dB relative to the measured antenna gain essential requirements: basic set of parameters and functions which are necessary to meet any regulatory obligations imposed for radio frequency co-ordination ETSI
SIST EN 301 126-3-2 V1.2.1:2003
8 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
fixed beam: the radiation pattern in use is fixed relative to a defined mechanical reference plane full conformance: the status of the IUT when it has successfully passed all the requirements of the conformance testing process and therefore meets all the mandatory requirements of the ETS/EN gain: ratio of the radiation intensity in a given direction to the radiation intensity that would be obtained if the power accepted by the antenna were radiated isotropically half power beamwidth: angle, relative to the main beam axis, between the two directions at which the measured co-polar pattern is 3 dB below the value on the main beam axis input port(s): flange(s) or connector(s) through which access to the antenna is provided inter-port isolation: ratio in dB of the power level applied to one port of a multi-port antenna to the power level received in any other port of the same antenna as a function of frequency Implementation Under Test (IUT): representative sample of the equipment to be tested isotropic radiator: hypothetical, lossless antenna having equal radiation intensity in all directions Left hand (anticlockwise) polarised wave: an elliptically-or circularly-polarised wave, in which the electric field vector, observed in any fixed plane, normal to the direction of propagation, rotates in time in a left-hand or anticlockwise direction main beam axis: direction for which the radiation intensity is a maximum main beam: radiation lobe containing the direction of maximum radiation mandatory requirements: a mandatory requirement is defined as one which the IUT (implementation under test) shall meet. To achieve full conformance all ETS/EN requirements are mandatory mechanical tilt: fixed angular shift in elevation of the antenna main beam axis by a change to the physical mounting optional requirements: the term "optional" is used in ETS/EN with two different meanings:
- Optional in the sense that the parameter or function itself is mandatory but there is more than one possible value or configuration which may be chosen (e.g. class of Antenna RPE, frequency band(s), etc.). Once an option is selected it becomes mandatory;
- Optional in the sense that the feature is not mandatory (e.g. antenna input connector etc.). However, once such an option has been implemented it becomes mandatory that it conforms to the requirements of the ETS/EN. radiation pattern: envelope within which the radiation pattern shall fit Radiation Pattern Envelope (RPE): envelope below which the RADIATION PATTERN shall fit radiation pattern: diagram relating power flux density at a constant distance from the antenna to the direction relative to the notional antenna main beam axis. Specifically referenced in the present document to the zero degree reference direction.
radome: cover, of dielectric material, intended for protecting an antenna from the effects of its physical environment repeater station: radio station providing the connection via the air to both the central station and the terminal station(s). The remote station may also provide the interfaces to the subscriber equipment, if applicable. right hand (clockwise) polarised wave: an elliptically-or circularly-polarised wave, in which the electric field vector, observed in any fixed plane, normal to the direction of propagation, rotates in time in a right-hand or clockwise direction sector angle: declared angle of coverage in azimuth of a sectored antenna NOTE: Defined as 2α in the present document.
supplier: organization requesting the approval Supplier's Declaration (SD): procedure by which a supplier gives written assurance that a parameter or function conforms to the ETS/EN ETSI
SIST EN 301 126-3-2 V1.2.1:2003
9 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
type approval authority: National Regulatory/Licensing Authority type approval testing: type approval testing is the process of type testing for approval NOTE: A type test is to be carried out successfully in order to achieve approval. type testing: type testing is where a representative sample of the equipment is tested NOTE: The test result is considered to be applicable and representative for all subsequent units of the same type. Any changes that could potentially affect the three essential requirements shall be notified to the Type Approval Authority.
Terminal Station (TS): remote (out) station which communicates with a central station tilt: fixed, angular shift of the antenna main beam axis (boresight) in the elevation plane by either electrical, electronic or mechanical means zero degree: declared direction as referenced to the antenna reference direction: mechanical characteristics, used as reference for the RPE integrated antenna: the antenna is considered to be integral to the product if either the antenna forms a component of the enclosure or the antenna is contained within the overall enclosure of the product
3.2 Symbols
For the purposes of the present document, the following symbols apply:
dBi decibels relative to an isotropic radiator dBiC decibels relative to an isotropic circularly polarised source dBm decibels relative to milli-Watt dB deciBel 2α sector angle, (twice alpha) GHz GigaHertz MHz MegaHertz
3.3 Abbreviations
For the purposes of the present document, the following abbreviations apply:
CR Complementary Requirement CS Central Station ER Essential Requirement Ext Extreme conditions IUT Implementation Under Test OR Optional Requirement P-MP Point-to-MultiPoint P-P Point-to-Point Ref Reference conditions RL Return Loss RPE Radiation Pattern Envelope RS Repeater Station SD Supplier's Declaration TR Test Required TS Terminal Station VSWR Voltage Standing Wave Ratio ETSI
SIST EN 301 126-3-2 V1.2.1:2003
10 ETSI EN 301 126-3-2 V1.2.1 (2003-12)
4 Requirements related to antennas conformance test
P-MP antennas may be designed for Central Station (CS), Repeater Station (RS) or Terminal Station (TS) use, and may be categorized in the corresponding standard by means of type, class and range, as required [1], [2] and [3]. Some P-MP antennas require definition of the antenna zero degree reference, which is defined as the declared direction as referenced to the antenna mechanical characteristics, and this is used as reference for the RPE. Although the RPE limits for TS and some RS antennas are generally identical for azimuth and elevation, the actual patterns should not be assumed to be symmetric.
4.1 General requirements
In table 1 the generic clauses and parameters are classified, for conformance test purposes, in terms of the various categories. The table also provides for defining the climatic conditions applicable during testing of the parameters. Table 1: "Generic requirements" classification Function or Status for Requirement for Power Climatic Limiting Test methods Parameter conformance conformance test supply conditions values Description conditions for test ER CR OR SD TR SD + Ref Ref + Ref Ref + Clause IEC 60835-2-2 [13] (see TR Ext (see Ext Ref. or other references.
...