ISO/FDIS 22176
(Main)Cosmetics — Analytical methods — Validation of quantitative analytical methods using an integrated approach
- Abstract
This document defines a global approach for the validation of a quantitative analytical method, based on the construction and interpretation of an accuracy profile, and specifies its characterization procedure. This procedure is particularly applicable for internal validation in a cosmetic testing laboratory, but its scope can be extended to the interpretation of data collected for an interlaboratory study designed according to the recommendations of the ISO 5725-1. It does not apply to microbiological trials. The present approach is particularly suited to handle the wide diversity of matrices in cosmetics. This document only applies to already fully-developed and finalized methods for which selectivity/specificity have already been studied and the scope of the method to be validated has already been defined, in terms of matrix types and measurand (for example analyte) concentrations.
- Status
- Not Published
- Technical Committee
- ISO/TC 217 - Cosmetics
- Drafting Committee
- ISO/TC 217/WG 3 - Analytical methods
- Current Stage
- 5000 - Final text received or FDIS registered for formal approval - 50 Approval
- Start Date
- 06-Oct-2026
- Due Date
- 09-Nov-2026
- Completion Date
- 09-Nov-2026
ISO/FDIS 22176 is an ISO draft standard for cosmetics that sets an integrated approach for validating quantitative analytical methods by building and interpreting an accuracy profile. It is aimed at cosmetic testing laboratories, and it also supports interpretation of data from an interlaboratory study. The document focuses on already developed methods for defined matrix types and measurand ranges, so users can check whether a routine method is fit for its intended use.
What does ISO/FDIS 22176 specify?
ISO/FDIS 22176 specifies how to validate a quantitative analytical method for cosmetics using an accuracy profile, and how to organize the measurements needed to characterize its performance. It is written for internal validation in a cosmetic testing laboratory, but its scope can also extend to interlaboratory study data designed according to ISO 5725-1 recommendations.
The standard applies only to finalized methods where selectivity/specificity has already been studied and the scope has already been defined in terms of matrix types and measurand concentrations. It does not apply to microbiological trials.
The document is organized into these main parts:
| Annex | What it covers |
|---|---|
| Annex A | Calculation of repeatability, intermediate precision and reproducibility standard deviations |
| Annex B | Contents of the validation file |
| Annex C | Worked example for NDELA in cosmetic samples |
| Annex D | Influence of the value of β on the tolerance interval |
| Annex E | Contribution to the uncertainty calculation |
| Annex F | Choice of acceptance limits |
| Annex G | Link to other guidelines based on ISO 5725-2 |
What are the key requirements of ISO/FDIS 22176?
ISO/FDIS 22176 requires a validation workflow built around the measured quantity, the validation scope, validation samples, an experimental plan, and the accuracy profile. In practice, the method is considered valid only when the calculated tolerance intervals stay within the chosen acceptance limits over the intended scope.
Define the measured quantity and keep it aligned with routine use
Clause 5.1 requires the measured quantity to be defined exactly as it will be used in routine analysis. For indirect methods, the document distinguishes the calibration step from the final concentration calculation; for direct methods, the concentration is obtained directly. This matters because the validation must mirror the actual reporting practice.
Set the validation scope, acceptance limits and β proportion
Clause 5.2 asks the user to define the scope of validation as a concentration range for one or more matrices, then choose acceptance limits that reflect the maximum allowable total error. The document states that β shall be at least 80% for cosmetics. In practice, this means the lab must decide how much future result spread it is prepared to accept before the study starts.
Use representative validation samples with independent reference values
Clause 5.3 requires validation samples that represent the scope of the method, including low and high levels and all relevant matrices. Reference values must be established independently of the method under validation, using options such as certified reference materials, spiking, standard addition, or a validated reference method. This is critical because the trueness assessment depends on the reference values being trustworthy.
Build a suitable characterization plan
Clause 5.4 requires a characterization plan with series, repetitions and concentration levels. The minimum design is at least 5 series, at least 2 repetitions per series and at least 3 concentration levels, with more levels recommended near the limit of quantitation. The practical point is that the plan must capture routine sources of variation, such as day, operator or instrument.
Add a calibration plan for indirect methods
Clause 5.5 makes a calibration plan compulsory only for indirect methods. The calibration range must support the response model without extrapolating beyond the response values used in the plan, and the calibration and validation series should be synchronized when they share the same sources of variation. This prevents a method from being validated in one range and then used outside the range where the model was checked.
Test under routine-like precision conditions
Clause 5.6 requires the measurements to be made under intermediate precision or reproducibility conditions, depending on the intended use. The same routine number of repetitions must be kept, and the experimental design should cover the full intended scope. In practice, the study should reflect how the method will really be run, not an idealized laboratory setting.
Calculate trueness, precision, tolerance intervals and the accuracy profile
Clauses 5.7 to 5.10 require back-calculated concentrations for indirect methods, then calculation of trueness and precision criteria by concentration level, followed by tolerance intervals and the accuracy profile. The decision rule is simple: if the tolerance interval stays inside the acceptance interval, the method is valid for that part of the scope. Clause 6 then requires the validation conclusion to state the acceptance limits, β, the precision conditions used, and the scope of validity.
Clause 7 adds that routine use must be monitored so results stay acceptable, for example with a control chart. If corrective actions do not work, revalidation may be needed.
What terms does ISO/FDIS 22176 define?
- Measurand - the quantity intended to be measured; in chemistry, this is often the analyte.
- Accuracy profile - a graph combining β-expectation tolerance intervals and acceptance intervals across concentration levels.
- β-expectation tolerance interval - an interval expected to contain, on average, a defined proportion β of future results.
- Acceptance interval - the allowable deviation around the reference value set by the user or by a requirement.
- Validation sample - a control sample with an assigned reference value, for example a CRM, spiked sample or standard-addition sample.
- Scope of validation - the matrix types and concentration range covered by the validation study.
- Scope of validity - the part of the validation scope for which future results are considered valid.
- Limit of quantitation (LOQ) - the lowest and/or highest concentration that can be quantified under the method conditions.
Who uses ISO/FDIS 22176?
ISO/FDIS 22176 is used by cosmetic testing laboratories that validate quantitative methods for routine release, quality control or development work. It is also useful for method developers, quality managers, accreditation teams and buyers who need to judge whether a laboratory method is validated for the right matrices and concentration range.
The document is especially relevant when the lab works with many cosmetic matrices, low analyte concentrations, or indirect instrumental methods that need calibration. It also supports interlaboratory study interpretation when several laboratories contribute data.
Which standards are used with ISO/FDIS 22176?
| Standard | Contribution |
|---|---|
| ISO 5725-2:2019 | Basis for repeatability and reproducibility calculations, including the statistical treatment used in Annex A |
| ISO 11095:1996 | Linear calibration using reference materials, used when establishing reference values and calibration-related practice |
| ISO 13528:2022 | Statistical methods for interlaboratory comparison, used for sample homogeneity/stability and reference-value approaches in interlaboratory studies |
| ISO/IEC Guide 99:2007 | Vocabulary for measurement terms such as trueness, precision, accuracy and validation |
| ISO 5725-1 | Recommended basis for interpreting interlaboratory study data mentioned in the scope |
| ISO/IEC 17025:2017 | The laboratory competence framework cited for the performance-goal approach and uncertainty thinking |
| ISO 7870-1:2019 | Control charts for routine monitoring after validation |
| ISO 21748:2017 | Guidance used in Annex E for linking validation data to uncertainty evaluation |
| ISO 15819:2014 and ISO 10130:2009 | Example cosmetic methods used in Annex C for NDELA |
What does the ISO/FDIS 22176 document contain?
The document contains the statistical model, the validation workflow, calculation steps, and a validation-file structure. It includes formulas for precision estimates, inverse prediction, tolerance intervals and the accuracy profile, plus tables that organize validation and calibration data.
It also includes a worked example for NDELA in a cosmetic body wash, with supporting tables and figures showing how the profile is built and interpreted. Annex D, Annex E and Annex F provide practical guidance on β, uncertainty contribution and acceptance limits.
Relations
- Effective Date
- 25-Nov-2023
Get Certified
Connect with accredited certification bodies for this standard

ECOCERT
Organic and sustainability certification.

Eurofins Food Testing Global
Global leader in food, environment, and pharmaceutical product testing.

Intertek Bangladesh
Intertek certification and testing services in Bangladesh.
Sponsored listings
Frequently Asked Questions
ISO/FDIS 22176 is a draft published by the International Organization for Standardization (ISO). Its full title is "Cosmetics — Analytical methods — Validation of quantitative analytical methods using an integrated approach". This standard covers: This document defines a global approach for the validation of a quantitative analytical method, based on the construction and interpretation of an accuracy profile, and specifies its characterization procedure. This procedure is particularly applicable for internal validation in a cosmetic testing laboratory, but its scope can be extended to the interpretation of data collected for an interlaboratory study designed according to the recommendations of the ISO 5725-1. It does not apply to microbiological trials. The present approach is particularly suited to handle the wide diversity of matrices in cosmetics. This document only applies to already fully-developed and finalized methods for which selectivity/specificity have already been studied and the scope of the method to be validated has already been defined, in terms of matrix types and measurand (for example analyte) concentrations.
This document defines a global approach for the validation of a quantitative analytical method, based on the construction and interpretation of an accuracy profile, and specifies its characterization procedure. This procedure is particularly applicable for internal validation in a cosmetic testing laboratory, but its scope can be extended to the interpretation of data collected for an interlaboratory study designed according to the recommendations of the ISO 5725-1. It does not apply to microbiological trials. The present approach is particularly suited to handle the wide diversity of matrices in cosmetics. This document only applies to already fully-developed and finalized methods for which selectivity/specificity have already been studied and the scope of the method to be validated has already been defined, in terms of matrix types and measurand (for example analyte) concentrations.
ISO/FDIS 22176 is classified under the following ICS (International Classification for Standards) categories: 71.100.70 - Cosmetics. Toiletries. The ICS classification helps identify the subject area and facilitates finding related standards.
ISO/FDIS 22176 has the following relationships with other standards: It is inter standard links to ISO/TS 22176:2020. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
ISO/FDIS 22176 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and symbols
- 3.1 Terms and definitions
- 3.1.1 measurement
- 3.1.2 measurand
- 3.1.3 measurement trueness
- 3.1.4 measurement precision
- 3.1.5 repeatability condition
- 3.1.6 measurement repeatability
- 3.1.7 intermediate precision condition
- 3.1.8 intermediate measurement precision
- 3.1.9 reproducibility condition of measurement
- 3.1.10 measurement reproducibility
- 3.1.11 measurement accuracy
- 3.1.12 verification
- 3.1.13 validation
- 3.1.14 selectivity
- 3.1.15 reference value
- 3.1.16 scope
- 3.1.17 scope of validation
- 3.1.18 scope of validity
- 3.1.19 quantitative method
- 3.1.20 reference method
- 3.1.21 alternative method
- 3.1.22 matrix
- 3.1.23 series
- 3.1.24 accuracy profile
- 3.1.25 β-expectation tolerance interval
- 3.1.26 acceptance interval
- 3.1.27 linearity
- 3.1.28 validation sample
- 3.1.29 limit of quantitation
- 3.1.30 limit of detection
- 3.2 Symbols
- 4 General principles
- 4.1 Reminder
- 4.2 Various conditions for the estimation of precision
- 4.3 Accuracy profile
- 5 Procedure
- 5.1 Definition of the measured quantity
- 5.2 Definition of objectives
- 5.3 Selection of validation samples
- 5.4 Characterization plan for validation
- 5.5 Calibration plan for the indirect methods
- 5.6 Testing
- 5.7 Calculation of predicted inverse concentrations for indirect methods
- 5.8 Calculation of the validation criteria by concentration level
- 1 I J
- 5.9 Construction of the accuracy profile
- 5.10 Interpretation of the accuracy profile for validation
- 6 Conclusion of the validation
- 7 Management of the outcomes during routine use
- Annex A
- Annex B
- Annex A
- 5.8.3 termediate precision (%)
- Annex C
- 9 Mean relative bias 2,6 % −0,8 % −7,3 % −5,9 %
- 10 Mean recovery rate 102,6 % 99,2 % 92,7 % 94,1 %
- 15 Intermediate precision standard devia-
- 17 Relative standard deviation 10,1 % 8,0 % 6,4 % 7,1 %
- 18 Relative standard deviation 10,1 % 8,2 % 7,9 % 7,6 %
- 20 Relative total error 12,7 % 9,1 % 15,1 % 13,6 %
- 25 Relative lower tolerance limit expressed 88,9 % 87,9 % 81,5 % 83,5 %
- 26 Relative upper tolerance limit expressed 116,4 % 110,4 % 104,0 % 104,6 %
- 27 Relative lower tolerance limit expressed −11,1 % −12,1 % −18,5 % −16,5 %
- 28 Relative upper tolerance limit expressed 16,4 % 10,4 % 4,0 % 4,6 %
- Annex D
- Annex E
- Annex F
- Annex G
- Bibliography
Introduction
The purpose of this document is to propose a characterization protocol for the validation of a quantitative analysis method in the cosmetic field and thus responds to the requirements of ISO/IEC 17025, which advocates a performance goal-based approach. The theoretical principles of this approach can be found in [1] [2] Bibliographic References and NF V 03 110:2010 .
Analytical methods for analyses of cosmetics need to be validated. Validation has been long considered as a process consisting in individually verifying several different criteria, i.e. selectivity, repeatability, linearity, [1] trueness, etc. The integrated approach, also known as the global approach, as proposed since 2003 , is based on the total error concept and the term ‘’global” means that only a single criterion has to be checked to validate a method: the agreement between a future experimental result and the true value. This approach [1],[3] [2] has already been applied in the domains of pharmacy , agricultural chemistry NF V 03 110:2010 , and [4] is in agreement with quality assurance guidelines such as GLP or ISO/IEC 17025:2017 . This validation process applies generally to already developed methods and integrates evaluations of the following criteria:
precision, trueness, linearity of the method, lower and upper limits of quantification, stability, ruggedness. NOTE 1 This approach is also known as “combined approach” in the International Council for Harmonisation [5] Q2(R2) guideline regarding pharmaceuticals.
NOTE 2 Since this document deals with the validation of a quantitative analytical method, it does not propose a specific approach for the limit of detection calculation. For this purpose, other standards and guidelines already exist. The large number of cosmetic products and the variety of matrices present a challenge for an analytical laboratory requiring that standardized methods be adapted for each type of sample. Additional difficulties are linked to the very low concentrations to be measured, typically in the range of milligrams per kilogram (mg/kg) or micrograms per kilogram (µg/kg). In such a context, criteria such as accuracy and uncertainty of measurement of the analytical results are of the utmost importance. When the concentration of a substance is determined by an analytical laboratory, it is important to evaluate the gap between the measured value and the known true value. This difference indicates the trueness of the analysis. If cosmetic samples are analysed several times in different conditions (laboratory, instrument, operator), the individual results will present a dispersal around the average value which represents the precision of the measurement. As for the individual measurement, it represents an error with the average value and an inaccuracy with regard to the reference value (i.e. the true value). Figure 1 — Illustration of the concepts of accuracy, precision and trueness When a laboratory measures the concentration of a given substance in a cosmetic product sample, the value which is obtained is thus characterized by a given accuracy which includes at the same time the notion of trueness and precision (see Figure 1). It can also be considered as total error. The assurance that the accuracy of a result is below acceptable limits, is thus one of the ways to make sure of the validity of a measurement.
oSIST ISO/DIS 22176:2026 ISO/DIS 22176:2026(en) The accuracy profile (plot of accuracy versus concentration), such as it is developed in numerous domains [3],[6],[7],[8],[9],[10],[11] , is thus the way to know the accuracy on a result obtained with a given method applied to a type of sample in the environment of a given laboratory.
To reach this accuracy profile, it is necessary to undergo a specific assay allowing to demonstrate the validity of the analytical method, as well as the accuracy of the measurement for a given substance. In this [12] approach, it is necessary to determine a tolerance interval which contains a given proportion (β) of future measured values inside (in average). If this tolerance interval is located inside a limit of acceptability defined a priori, taking into consideration several parameters such as the type and concentration of analyte, type of matrix, of analysis and conditions of the experiments, in this case, the method will be considered as valid, and if it goes outside this limit of acceptability, the method will be considered as non-valid (see Figure 2).
Key mean value true value Figure 2 — Illustration of the validation principle
oSIST ISO/DIS 22176:2026
oSIST ISO/DIS 22176:2026 DRAFT International Standard ISO/DIS 22176:2026(en) Cosmetics — Analytical methods — Validation of quantitative analytical methods using an integrated approach
1 Scope
This document defines an integrated approach for the validation of a quantitative analytical method, based on the construction and interpretation of an accuracy profile, and specifies its characterization procedure. This procedure is particularly applicable for internal validation in a cosmetic testing laboratory, but its scope can be extended to the interpretation of data collected for an interlaboratory study designed according to the recommendations of the ISO 5725-1. It does not apply to microbiological trials. The present approach is particularly suited to handle the wide diversity of matrices in cosmetics. This document only applies to already fully-developed and finalized methods for which selectivity/specificity have already been studied and the scope of the method to be validated has already been defined, in terms of matrix types and measurand (for example analyte) concentrations.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 5725-2:2019, Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method ISO 11095:1996, Linear calibration using reference materials ISO 13528:2022, Statistical methods for use in proficiency testing by interlaboratory comparison ISO/IEC Guide 99:2007, International vocabulary of metrology — Basic and general concepts and associated terms (VIM)
3 Terms, definitions and symbols
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO/IEC Guide 99 and the following apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses:
- ISO Online browsing platform: available at https:// www .iso .org/ obp
- IEC Electropedia: available at http:// www .electropedia .org/
3.1.1 measurement
process of experimentally obtaining one or more quantity values that can reasonably be attributed to a quantity [SOURCE: ISO/IEC Guide 99:2007, 2.1, modified — Notes to entry have been excluded.]
oSIST ISO/DIS 22176:2026 ISO/DIS 22176:2026(en)
3.1.2 measurand
quantity intended to be measured Note 1 to entry: The term “analyte”, employed in chemistry, is a synonym of measurand, and is used more generally. [SOURCE: ISO/IEC Guide 99:2007, 2.3, modified — Original notes to entry have been excluded and a new note to entry has been added.]
3.1.3 measurement trueness
trueness closeness of agreement between the average of values obtained by replicate measurements of the same or similar objects under specified conditions and a reference quantity value [SOURCE: ISO/IEC Guide 99:2007, 2.14, modified — Notes to entry have been excluded.]
3.1.4 measurement precision
precision closeness of agreement between indications or measured quantity values obtained by replicate measurements on the same or similar objects under specified conditions [SOURCE: ISO/IEC Guide 99:2007, 2.15, modified — Notes to entry have been excluded.]
3.1.5 repeatability condition
condition of measurement, out of a set of conditions that includes the same measurement procedure, same operator, same measuring system, same operating conditions and same location, and replicate measurements on the same or similar objects over a short period of time [SOURCE: ISO/IEC Guide 99:2007, 2.20, modified — Notes to entry have been excluded.]
3.1.6 measurement repeatability
repeatability measurement precision under a set of repeatability conditions (3.1.5) of measurement [SOURCE: ISO/IEC Guide 99:2007, 2.21]
3.1.7 intermediate precision condition
condition of measurement, out of a set of conditions that includes the same measurement procedure, same location, and replicate measurements on the same or similar objects over an extended period of time, but may include other conditions involving changes [SOURCE: ISO/IEC Guide 99:2007, 2.22, modified — Notes to entry have been excluded.]
3.1.8 intermediate measurement precision
intermediate precision measurement precision under a set of intermediate precision conditions (3.1.7) of measurement [SOURCE: ISO/IEC Guide 99:2007, 2.23, modified — Notes to entry have been excluded.]
3.1.9 reproducibility condition of measurement
reproducibility condition condition of measurement, out of a set of conditions that includes different locations, operators, measuring systems, and replicate measurements on the same or similar objects [SOURCE: ISO/IEC Guide 99:2007, 2.24, modified — Note to entry has been excluded.]
oSIST ISO/DIS 22176:2026 ISO/DIS 22176:2026(en)
3.1.10 measurement reproducibility
reproducibility measurement precision under reproducibility conditions of measurement (3.1.9) [SOURCE: ISO/IEC Guide 99:2007, 2.25, modified — Note to entry has been excluded.]
3.1.11 measurement accuracy
accuracy closeness of agreement between a measured quantity value and a true quantity value of a measurand [SOURCE: ISO/IEC Guide 99:2007, 2.13, modified — Notes to entry have been excluded.]
3.1.12 verification
provision of objective evidence that a given item fulfils specified requirements, taking into account any measurement uncertainty [SOURCE: ISO/IEC Guide 99:2007, 2.44, modified — Notes to entry have been excluded.]
3.1.13 validation
verification, where the specified requirements are adequate for an intended use Note 1 to entry: The term “characterization” applies to the method, whereas the term “verification” applies to the outcomes. Validation of the method therefore consists of checking if the results are adequate for an intended use. [SOURCE: ISO/IEC Guide 99:2007, 2.45, modified — Example has been excluded and a Note to entry has been added.]
3.1.14 selectivity
property of a measuring system, used with a specified measurement procedure, whereby it provides measured quantity values for one or more measurands such that the values of each measurand are independent of other measurands or other quantities in the measuring system Note 1 to entry: The IUPAC considers specificity as the final stage of selectivity. [SOURCE: ISO/IEC Guide 99:2007, 4.13, modified — Examples and original notes to entry have been excluded. A new note to entry has been added.]
3.1.15 reference value
quantity value whose associated measurement uncertainty is generally considered small enough so that the value may be used as a basis for comparison with quantity values of the same kind [SOURCE: ISO/IEC Guide 99:2007, 5.18, modified — Notes to entry have been excluded.]
3.1.16 scope
<of the method>all of the types of matrix (3.1.22) to which the method applies, taking into account the range of concentrations involved in validation
3.1.17 scope of validation
all of the types of matrix (3.1.22) to which the method and range of concentrations involved in validation applies
3.1.18 scope of validity
all of the types of matrix (3.1.22) to which the method and range of concentrations involved in validation applies, and for which future outcomes obtained via the method will be considered valid
oSIST ISO/DIS 22176:2026 ISO/DIS 22176:2026(en)
3.1.19 quantitative method
method of analysis which determines the quantity or weight fraction of an analyte so that it may be expressed as a numeric value in the appropriate units
3.1.20 reference method
method of analysis recognized by experts or used as a reference by agreement between parties, which gives, or is supposed to give the accepted reference value of the measurand
3.1.21 alternative method
method of analysis used by the laboratory instead of one or several reference methods (3.1.20)
3.1.22 matrix
set of properties of the sample and its components other than the analyte Note 1 to entry: The matrix effect reflects the possible influence that these properties or components can have on the instrumental response. For practical reasons, since the matrix effect can vary in the different stages of analysis, a type of matrix is defined as a group of materials or products recognized by the analyst as having consistent behaviour with regard to the method of analysis used.
3.1.23 series
set of measurements carried out under a set of repeatability conditions Note 1 to entry: For example, a series includes measurements carried out on the same day and/or by the same operator.
3.1.24 accuracy profile
combination, in a graphic form, of one or several β-expectation tolerance intervals (3.1.25) calculated at different concentrations, and of one or several acceptance intervals (3.1.26)
3.1.25 β-expectation tolerance interval
tolerance interval interval which contains, on average, a defined proportion, β %, of future measurements, obtained according to a given procedure and for a given concentration Note 1 to entry: The limits of the interval are calculated based on trials conducted for the purpose of validation. Note 2 to entry: A value of 80 % for β % means that, on average, one out of five results will be outside the limits of the tolerance interval. See 5.10.
3.1.26 acceptance interval
specification of the performance required for the method, expressed as an acceptable deviation around the reference value Note 1 to entry: The limits of the interval are set by the client or by statutory requirements, sometimes according to the concentration. They are expressed as ±λ as absolute values and in the units of the measurand, or (1 ± λ) × 100 as relative values.
3.1.27 linearity
<of the method> establishment of a linear relationship between the deduced (or quantified) quantities in the samples and their reference values Note 1 to entry: Linearity of the method is different from linearity of the response function of the measuring apparatus, which only characterizes the instrumental response during calibration and is not essential for accurate quantitation.
oSIST ISO/DIS 22176:2026 ISO/DIS 22176:2026(en)
3.1.28 validation sample
control sample material to which the reference value may be assigned, either because it is a reference material (certified or uncertified), or because the molecule to be assayed has been subjected to standard addition
3.1.29 limit of quantitation
the lowest and/or highest concentration of analyte that may be quantified under the experimental conditions of the method. It corresponds to the lowest and/or highest concentration of the scope of validity (3.1.18) Note 1 to entry: According to the SFSTP (French society for pharmaceutical sciences and technology), the lower limit of quantitation is the smallest quantity of analyte in a sample that may be assayed under the experimental conditions described with a defined level of accuracy.
3.1.30 limit of detection
measured quantity value, obtained by a given measurement procedure, for which the probability of falsely claiming the absence of a component in a material is b, given a probability, α, of falsely claiming its presence Note 1 to entry: The notation b used in this definition incurs a risk of type II error. Note 2 to entry: IUPAC recommends default values for α and b equal to 0.05. [SOURCE: ISO/IEC Guide 99:2007, 4.18, modified — Original notes to entry have been omitted and a new note to entry has been added.]
3.2 Symbols
i series of measurements (i varying from 1 to I), includes k concentration levels (k varying from 1 to K), for which j repetitions have been performed (j varying from 1 to J). The subscripts are written in the following order: i,j,k. The random variables are written in upper case letters and their values in lower case letters. Description of abbreviations used in formulae is given in Table 1. Table 1 — Meaning of the different abbreviations used in formulae Symbol Description Reference value assigned to a calibration standard for series i (1 ≤ i ≤ I), repetition j (1 ≤ j ≤ J) and concentration k (1 ≤ k ≤ K)
ijk or Reference value assigned to a validation sample for series i, repetition j and concentration k. Measurement of the instrumental or experimental response observed for a calibration standard or vali- y ijk dation sample for series i, repetition j and concentration k.
Deduced value for a validation sample for series i, repetition j and concentration k, obtained either by z ijk inverse prediction using a calibration model or by direct measurement. Bias expressing the trueness error for a validation sample between the deduced value and its reference b ijk value b = z − x ijk ijk ijk
oSIST ISO/DIS 22176:2026 ISO/DIS 22176:2026(en)
4 General principles
4.1 Reminder
The accuracy profile allows a statistical approach to validation. Formula (1) is used to describe a measurement, z, of a measurand, Z, from a laboratory:
z = m + B + e (1) where m is the overall average for the homogeneous sample sent to the laboratories; B is the bias component of the laboratory under conditions of repeatability; e is the random error occurring in each measurement, under conditions of repeatability. As part of an interlaboratory study, the bias component B comes from the laboratory, but it may also come from any other source of uncertainty in an intralaboratory study, such as the day, operator, instrument, etc. In addition to the statistical methods for calculating the accuracy criteria, the present document also provides details of the organization of data collection and precautions to be taken.
4.2 Various conditions for the estimation of precision
According to its definition, precision can be estimated under various conditions. In any case, precision is quantified based on a standard deviation, be this for repeatability s , intermediate precision s or r IP reproducibility s . A complexity scale may be established between these different standard deviations, R according to the number of sources of variation. Figure 3 illustrates this gradation, from conditions of repeatability where there is no identified variation factor and/or systematic variation component for calculating the deviation between repetitions, to the various possibilities for estimating intermediate precision and, finally, conditions of reproducibility for which the number of sources is not known. To simplify presentation, the notion of series refers to a set of repetitions performed under conditions of repeatability: a series groups together all of the measurements made under the same conditions, e.g. the same day, the same operator or a short period of time. For certain methods applying to samples that are highly unstable over time, the chosen series effect should be the operator rather than the day; the series will thus include repetitions performed by the same operator:
...