Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)

This document specifies methods for the determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) of polymeric materials by means of differential scanning calorimetry (DSC). It is applicable to polyolefin resins that are in a fully stabilized or compounded form, either as raw materials or finished products. It can be applicable to other plastics.

Plastiques — Analyse calorimétrique différentielle (DSC) — Partie 6: Détermination du temps d'induction à l'oxydation (OIT isotherme) et de la température d'induction à l'oxydation (OIT dynamique)

Le présent document spécifie des méthodes de détermination du temps d’induction à l’oxydation (OIT isotherme) et de la température d’induction à l’oxydation (OIT dynamique) des matériaux polymères au moyen de l’analyse calorimétrique différentielle (DSC). Il s’applique aux résines polyoléfines sous forme totalement stabilisée ou sous forme de composition, soit comme matières premières, soit comme produits finis. Il peut s’appliquer à d’autres plastiques.

General Information

Status
Published
Publication Date
05-Jun-2025
Current Stage
6060 - International Standard published
Start Date
06-Jun-2025
Due Date
27-Sep-2025
Completion Date
06-Jun-2025
Ref Project

Relations

Buy Standard

Standard
ISO 11357-6:2025 - Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) Released:6. 06. 2025
English language
12 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
ISO 11357-6:2025 - Plastiques — Analyse calorimétrique différentielle (DSC) — Partie 6: Détermination du temps d'induction à l'oxydation (OIT isotherme) et de la température d'induction à l'oxydation (OIT dynamique) Released:6. 06. 2025
French language
13 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


International
Standard
ISO 11357-6
Fourth edition
Plastics — Differential scanning
2025-06
calorimetry (DSC) —
Part 6:
Determination of oxidation
induction time (isothermal
OIT) and oxidation induction
temperature (dynamic OIT)
Plastiques — Analyse calorimétrique différentielle (DSC) —
Partie 6: Détermination du temps d'induction à l'oxydation (OIT
isotherme) et de la température d'induction à l'oxydation (OIT
dynamique)
Reference number
© ISO 2025
All rights reserved. Unless otherwise specified, or required in the context of its implementation, no part of this publication may
be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on
the internet or an intranet, without prior written permission. Permission can be requested from either ISO at the address below
or ISO’s member body in the country of the requester.
ISO copyright office
CP 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Geneva
Phone: +41 22 749 01 11
Email: copyright@iso.org
Website: www.iso.org
Published in Switzerland
ii
Contents Page
Foreword .iv
Introduction .v
1 Scope . 1
2 Normative references . 1
3 Terms and definitions . 1
4 Principle . 2
4.1 General .2
4.2 Oxidation induction time (isothermal OIT) .2
4.3 Oxidation induction temperature (dynamic OIT) .2
5 Apparatus and materials . 2
5.1 General .2
5.2 DSC instrument .3
5.3 Crucibles .3
5.4 Flowmeter.3
5.5 Oxygen .3
5.6 Air .3
5.7 Nitrogen .3
5.8 Gas-selector switch and regulators .3
6 Test specimens . 4
6.1 General .4
6.2 Specimens from compression-moulded plates .4
6.3 Specimens from injection-moulded plates or melt flow extrudates.4
6.4 Specimens from finished parts .4
7 Test conditions and specimen conditioning . 5
8 Calibration . 5
8.1 Oxidation induction time (isothermal OIT) .5
8.1.1 General .5
8.1.2 Dynamic temperature calibration .5
8.1.3 Isothermal stepwise temperature calibration .5
8.2 Oxidation induction temperature (dynamic OIT) .5
9 Procedure . 6
9.1 Setting up the instrument .6
9.2 Loading the test specimen into the crucible .6
9.3 Insertion of crucibles .6
9.4 Nitrogen, air and oxygen flow .6
9.5 Sensitivity adjustment .6
9.6 Performance of measurement .6
9.6.1 Oxidation induction time (isothermal OIT) .6
9.6.2 Oxidation induction temperature (dynamic OIT) .7
9.7 Cleaning .8
10 Expression of results . 8
11 Precision and bias .10
12 Test report . 10
Bibliography .12

iii
Foreword
ISO (the International Organization for Standardization) is a worldwide federation of national standards
bodies (ISO member bodies). The work of preparing International Standards is normally carried out through
ISO technical committees. Each member body interested in a subject for which a technical committee
has been established has the right to be represented on that committee. International organizations,
governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely
with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization.
The procedures used to develop this document and those intended for its further maintenance are described
in the ISO/IEC Directives, Part 1. In particular, the different approval criteria needed for the different types
of ISO documents should be noted. This document was drafted in accordance with the editorial rules of the
ISO/IEC Directives, Part 2 (see www.iso.org/directives).
ISO draws attention to the possibility that the implementation of this document may involve the use of (a)
patent(s). ISO takes no position concerning the evidence, validity or applicability of any claimed patent
rights in respect thereof. As of the date of publication of this document, ISO had not received notice of (a)
patent(s) which may be required to implement this document. However, implementers are cautioned that
this may not represent the latest information, which may be obtained from the patent database available at
www.iso.org/patents. ISO shall not be held responsible for identifying any or all such patent rights.
Any trade name used in this document is information given for the convenience of users and does not
constitute an endorsement.
For an explanation of the voluntary nature of standards, the meaning of ISO specific terms and expressions
related to conformity assessment, as well as information about ISO's adherence to the World Trade
Organization (WTO) principles in the Technical Barriers to Trade (TBT), see www.iso.org/iso/foreword.html.
This document was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 5, Physical-
chemical properties, in collaboration with the European Committee for Standardization (CEN) Technical
Committee CEN/TC 249, Plastics, in accordance with the Agreement on technical cooperation between ISO
and CEN (Vienna Agreement).
This fourth edition cancels and replaces the third edition (ISO 11357-6:2018), which has been technically
revised.
The main changes are as follows:
— the isothermal stepwise temperature calibration has been added for isothermal OIT.
A list of all parts in the ISO 11357 series can be found on the ISO website.
Any feedback or questions on this document should be directed to the user’s national standards body. A
complete listing of these bodies can be found at www.iso.org/members.html.

iv
Introduction
The measurement of oxidation induction time or temperature described in this document provides a tool
to assess the conformity of the material tested to a given formulation of plastics compounds. However, it
is not intended to provide the concentration of antioxidant. Different antioxidants can have different
oxidation induction times or temperatures. Due to interaction of the antioxidant with other substances in
the formulation, different oxidation induction times or temperatures can result even with products having
the same type and concentration of antioxidant.

v
International Standard ISO 11357-6:2025(en)
Plastics — Differential scanning calorimetry (DSC) —
Part 6:
Determination of oxidation induction time (isothermal OIT)
and oxidation induction temperature (dynamic OIT)
1 Scope
This document specifies methods for the determination of oxidation induction time (isothermal OIT) and
oxidation induction temperature (dynamic OIT) of polymeric materials by means of differential scanning
calorimetry (DSC). It is applicable to polyolefin resins that are in a fully stabilized or compounded form,
either as raw materials or finished products. It can be applicable to other plastics.
2 Normative references
The fol
...


Norme
internationale
ISO 11357-6
Quatrième édition
Plastiques — Analyse calorimétrique
2025-06
différentielle (DSC) —
Partie 6:
Détermination du temps
d'induction à l'oxydation (OIT
isotherme) et de la température
d'induction à l'oxydation (OIT
dynamique)
Plastics — Differential scanning calorimetry (DSC) —
Part 6: Determination of oxidation induction time (isothermal
OIT) and oxidation induction temperature (dynamic OIT)
Numéro de référence
DOCUMENT PROTÉGÉ PAR COPYRIGHT
© ISO 2025
Tous droits réservés. Sauf prescription différente ou nécessité dans le contexte de sa mise en œuvre, aucune partie de cette
publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique,
y compris la photocopie, ou la diffusion sur l’internet ou sur un intranet, sans autorisation écrite préalable. Une autorisation peut
être demandée à l’ISO à l’adresse ci-après ou au comité membre de l’ISO dans le pays du demandeur.
ISO copyright office
Case postale 401 • Ch. de Blandonnet 8
CH-1214 Vernier, Genève
Tél.: +41 22 749 01 11
E-mail: copyright@iso.org
Web: www.iso.org
Publié en Suisse
ii
Sommaire Page
Avant-propos .iv
Introduction .v
1 Domaine d'application . 1
2 Références normatives . 1
3 Termes et définitions . 1
4 Principe. 2
4.1 Généralités .2
4.2 Temps d’induction à l’oxydation (OIT isotherme) .2
4.3 Température d’induction à l’oxydation (OIT dynamique) .3
5 Appareillage et matériaux . 3
5.1 Généralités .3
5.2 Appareil DSC .3
5.3 Creusets .3
5.4 Débitmètre .3
5.5 Oxygène.3
5.6 Air .3
5.7 Azote .4
5.8 Sélecteurs de gaz et régulateurs . .4
6 Éprouvettes. 4
6.1 Généralités .4
6.2 Éprouvettes provenant de plaques moulées par compression .4
6.3 Éprouvettes provenant de plaques moulées par injection ou d’extrudats pour indice de
fluidité .4
6.4 Éprouvettes provenant de pièces finies .5
7 Conditions d’essai et conditionnement de l’éprouvette . 5
8 Étalonnage . 5
8.1 Temps d’induction à l’oxydation (OIT isotherme) .5
8.1.1 Généralités .5
8.1.2 Étalonnage dynamique de la température .5
8.1.3 Étalonnage par paliers isothermes de la température .6
8.2 Température d’induction à l’oxydation (OIT dynamique) .6
9 Mode opératoire . 6
9.1 Réglage de l’appareil .6
9.2 Chargement de l’éprouvette dans le creuset .6
9.3 Mise en place des creusets dans l’appareil .6
9.4 Débit d’azote, d’air et d’oxygène .6
9.5 Ajustement de la sensibilité .6
9.6 Réalisation des mesurages.7
9.6.1 Temps d’induction à l’oxydation (OIT isotherme) .7
9.6.2 Température d’induction à l’oxydation (OIT dynamique) .8
9.7 Nettoyage .8
10 Expression des résultats . 9
11 Fidélité et biais .11
12 Rapport d’essai .11
Bibliographie .13

iii
Avant-propos
L’ISO (Organisation internationale de normalisation) est une fédération mondiale d’organismes nationaux
de normalisation (comités membres de l’ISO). L’élaboration des Normes internationales est en général
confiée aux comités techniques de l’ISO. Chaque comité membre intéressé par une étude a le droit de faire
partie du comité technique créé à cet effet. Les organisations internationales, gouvernementales et non
gouvernementales, en liaison avec l’ISO participent également aux travaux. L’ISO collabore étroitement avec
la Commission électrotechnique internationale (IEC) en ce qui concerne la normalisation électrotechnique.
Les procédures utilisées pour élaborer le présent document et celles destinées à sa mise à jour sont
décrites dans les Directives ISO/IEC, Partie 1. Il convient, en particulier, de prendre note des différents
critères d’approbation requis pour les différents types de documents ISO. Le présent document a
été rédigé conformément aux règles de rédaction données dans les Directives ISO/IEC, Partie 2 (voir
www.iso.org/directives).
L’ISO attire l’attention sur le fait que la mise en application du présent document peut entraîner l’utilisation
d’un ou de plusieurs brevets. L’ISO ne prend pas position quant à la preuve, à la validité et à l’applicabilité de
tout droit de brevet revendiqué à cet égard. À la date de publication du présent document, l’ISO n’avait pas
reçu notification qu’un ou plusieurs brevets pouvaient être nécessaires à sa mise en application. Toutefois,
il y a lieu d’avertir les responsables de la mise en application du présent document que des informations
plus récentes sont susceptibles de figurer dans la base de données de brevets, disponible à l’adresse
www.iso.org/brevets. L’ISO ne saurait être tenue pour responsable de ne pas avoir identifié tout ou partie de
tels droits de brevet.
Les appellations commerciales éventuellement mentionnées dans le présent document sont données pour
information, par souci de commodité, à l’intention des utilisateurs et ne sauraient constituer un engagement.
Pour une explication de la nature volontaire des normes, la signification des termes et expressions
spécifiques de l’ISO liés à l’évaluation de la conformité, ou pour toute information au sujet de l’adhésion de
l’ISO aux principes de l’Organisation mondiale du commerce (OMC) concernant les obstacles techniques au
commerce (OTC), voir www.iso.org/avant-propos.
Le présent document a été élaboré par le comité technique ISO/TC 61, Plastiques, sous-comité SC 5, Propriétés
physicochimiques, en collaboration avec le comité technique CEN/TC 249, Plastiques, du Comité européen de
normalisation (CEN), conformément à l’Accord de coopération technique entre l’ISO et le CEN (Accord de
Vienne).
Cette quatrième édition annule et remplace la troisième édition (ISO 11357-6:2018), qui a fait l’objet d’une
révision technique.
Les principales modifications sont les suivantes:
— l'étalonnage par paliers isothermes de la température a été ajouté pour l'OIT isotherme.
Une liste de toutes les parties de la série ISO 11357 peut être trouvée sur le site internet de l’ISO.
Il convient que l’utilisateur adresse tout retour d’information ou toute question concernant le présent
document à l’organisme national de normalisation de son pays. Une liste exhaustive desdits organismes se
trouve à l’adresse www.iso.org/fr/members.html.

iv
Introduction
Il convient de noter que le mesurage du temps ou de la température d’induction à l’oxydation, décrit dans
le présent document, fournit un outil d’évaluation de la conformité du matériau soumis à essai selon une
formulation donnée de composés plastiques. Cependant, il n’est pas destiné à fournir la concentration
en antioxydant. Des antioxydants différents peuvent avoir des temps ou des températures d’induction
à l’oxydation différents. En raison de l’interaction des antioxydants avec d’autres substances dans la
formulation, différents temps ou températures d’induction à l’oxydation peuvent être obtenus, même avec
des produits ayant le même type et la même concentration d’antioxydant.

v
Norme internationale ISO 11357-6:2025(fr)
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.