Corrigendum 1 - Sound system equipment - Electroacoustical transducers - Measurement of suspension parts

Corrigendum 1 - Equipements pour systèmes électroacoustiques – Transducteurs électroacoustiques – Mesurage des pièces de suspension

General Information

Status
Published
Publication Date
19-Nov-2015
Current Stage
PPUB - Publication issued
Start Date
20-Nov-2015
Completion Date
06-Dec-2015
Ref Project

Relations

Standard
IEC 62459:2010/COR1:2015 - Corrigendum 1 - Sound system equipment - Electroacoustical transducers - Measurement of suspension parts Released:20. 11. 2015
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview
Standard
IEC 62459:2010/COR1:2015 - Corrigendum 1 - Sound system equipment - Electroacoustical transducers - Measurement of suspension parts Released:20. 11. 2015
English and French language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)


 IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 62459
Edition 1.0  2010-01
Sound system equipment –
Electroacoustical transducers –
Measurement of suspension parts

CO RRI G ENDU M 1
3.11
lowest cone resonance frequency

Replace the existing Formula (7) by the following new Formula:

1 Κ(x )
off
(7)
f ≈
2π δm
s
6.3 Incremental dynamic measurement

Replace the existing first sentence by the following:

This technique for measuring the incremental stiffness K (x ) according to Equation (3) uses a
inc dc
superposition of a d.c. signal of certain magnitude (for example, constant restoring force F
dc
generating a d.c. position x ) and a
...


 IEC 2015
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
IEC 62459
Edition 1.0  2010-01
Sound system equipment –
Electroacoustical transducers –
Measurement of suspension parts

CO RRI G E NDUM 1
3.11
lowest cone resonance frequency
Replace the existing Formula (7) by the following new Formula:

Κ(x )
off
(7)
f ≈
2π δm
s
6.3 Incremental dynamic measurement

Replace the existing first sentence by the following:
This technique for measuring the incremental stiffness K (x ) according to Equation (3)
inc dc
uses a superposition of a d.c. signal of certain magnitude (for example, constant restoring
generating a d.c. position x ) and a small a.c. signal (e.g. restoring force F ) as
force F
dc dc ac
stimulus and measures the a.c. response of the suspension part (e.g. the a.c. part of the
displacement x ) under steady-state condition.
ac
6.4 Full dynamic measurement
Replace the existing paragraph by the following:
This technique for measuring the dynamic stiffness K(x ) uses an a.c. signal of certain
ac
magnitude (for example, the a.c. restoring force F ) and measures the a.c. response of the
ac
suspension part (for example, a displacement x ).
ac
9.1 Characteristic to be specified

Replace, in the second sentence of this paragraph, "Equation (6)" by "Equation (1)".

IEC 62459:2010-01/COR1:2015-11(en)

– 2 – IEC 62459:2010/COR1:2015
 IEC 2015
COMMISSION ÉLECTROTECHNIQUE INTERNATI
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.

Loading comments...