IEC 61156-6-1:2002
(Main)Multicore and symmetrical pair/quad cables for digital communications - Part 6-1: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz - Work area wiring - Blank detail specification
Multicore and symmetrical pair/quad cables for digital communications - Part 6-1: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz - Work area wiring - Blank detail specification
This blank detail specification describes symmetrical pair/quad cables intended to construct patch, equipment, and work area cords in digital communication systems such as ISDN, local area networks and data communication systems using frequencies up to 600 MHz.
General Information
Relations
Overview
IEC 61156-6-1:2002 is an international standard published by the International Electrotechnical Commission (IEC) that provides a blank detail specification for symmetrical pair/quad cables designed for digital communications with transmission characteristics up to 600 MHz. These cables are primarily intended for use in work area wiring, patch cords, and equipment cords in digital communication systems such as ISDN, local area networks (LANs), and other data communication environments operating at frequencies up to 600 MHz.
This standard serves as a template for the preparation of detailed cable specifications by manufacturers, national organizations, or users, ensuring consistent quality, performance, and interoperability across the telecommunications and data networking industry.
Key Topics
Scope and Application: Specifies symmetrical pair/quad cables to be used in work areas for constructing cords in digital communication systems including enhanced Category 5 (Category 5e) and higher-grade cables.
Transmission Performance: Defines electrical and transmission characteristics including conductor resistance, capacitance, attenuation, crosstalk, impedance, and propagation delay parameters up to 600 MHz.
Construction Details: Provides guidelines on cable construction such as conductor type, insulation, screening, sheath material, diameter, bending radii, and marking for robust design and installation ease.
Mechanical and Environmental Requirements: Includes testing criteria like tensile strength, elongation, crush resistance, flame propagation, and performance under environmental stress like temperature variations and ageing.
Standard Layout for Detail Specifications: Establishes a consistent format for documenting cable parameters including references to related standards, cable descriptions, material details, electrical and mechanical characteristics, and applicable test methods.
Compatibility and References: Designed to be used in conjunction with IEC 61156-1 (generic specification) and IEC 61156-6 (sectional specification), with additional reference to ISO/IEC 11801 for generic cabling.
Applications
IEC 61156-6-1:2002 cables are widely applicable in:
Digital Communication Systems: Including ISDN and LAN installations where high-frequency signals up to 600 MHz require reliable transmission with minimal interference or loss.
Work Area Wiring: Used for patch cords and connectors that link end-user devices and active equipment within office, data center, or telecommunications environments.
Data Networks: Supports enhanced Category 5e and Category 6 cables, providing the backbone for high-speed Ethernet, Fast Ethernet, and Gigabit Ethernet networks.
Equipment Connectivity: Ensures efficient, shielded or unshielded connections in sensitive digital communication applications demanding strict electrical and mechanical performance standards.
Custom Cable Manufacturing: Enables manufacturers or users to develop tailored cable products using a standardized blank detail layout, ensuring compliance and interoperability.
Related Standards
IEC 61156-1: Generic specification for multicore and symmetrical pair/quad cables used in digital communications, providing fundamental requirements for cable construction and performance.
IEC 61156-6: Sectional specification detailing symmetrical pair/quad cables with transmission characteristics up to 600 MHz specifically for work area wiring.
ISO/IEC 11801:2000: International standard for generic cabling within customer premises, referencing cable categories and performance metrics suitable for various data communication needs.
Category 5e and Category 6 Specifications: Enhanced cabling performance specifications referenced within IEC 61156-6-1 for improved signal integrity and transmission quality.
Practical Value
Adhering to IEC 61156-6-1 ensures that symmetrical pair/quad cables used in digital communication work area wiring deliver reliable high-frequency performance up to 600 MHz, which is critical for modern data networks requiring fast and stable data transmission. Standardized detail specifications help manufacturers produce cables that meet consistent quality, safety, and interoperability benchmarks, while network designers and installers gain assurance of compatibility and performance in deployment environments.
For organizations involved in telecommunications infrastructure, leveraging IEC 61156-6-1 facilitates:
- Precise cable selection and specification for network design.
- Development of customized cables meeting global industry standards.
- Ensured signal integrity and minimal electromagnetic interference.
- Simplified conformance assessments due to standardized documentation.
- Effective work area wiring solutions compatible with evolving communication technologies.
By following this standardized blank detail specification, stakeholders contribute to the harmonized deployment of effective digital communication systems worldwide.
Standards Content (Sample)
INTERNATIONAL IEC
STANDARD
61156-6-1
First edition
2002-05
Multicore and symmetrical pair/quad cables
for digital communications –
Part 6-1:
Symmetrical pair/quad cables with transmission
characteristics up to 600 MHz –
Work area wiring –
Blank detail specification
Câbles multiconducteurs à paires symétriques et quartes
pour transmissions numériques –
Partie 6-1:
Câbles à paires symétriques et quartes avec caractéristiques
de transmission allant jusqu'à 600 MHz –
Raccordement de terminal –
Spécification particulière cadre
Reference number
Publication numbering
As from 1 January 1997 all IEC publications are issued with a designation in the
60000 series. For example, IEC 34-1 is now referred to as IEC 60034-1.
Consolidated editions
The IEC is now publishing consolidated versions of its publications. For example,
edition numbers 1.0, 1.1 and 1.2 refer, respectively, to the base publication, the
base publication incorporating amendment 1 and the base publication incorporating
amendments 1 and 2.
Further information on IEC publications
The technical content of IEC publications is kept under constant review by the IEC,
thus ensuring that the content reflects current technology. Information relating to
this publication, including its validity, is available in the IEC Catalogue of
publications (see below) in addition to new editions, amendments and corrigenda.
Information on the subjects under consideration and work in progress undertaken
by the technical committee which has prepared this publication, as well as the list
of publications issued, is also available from the following:
• IEC Web Site (www.iec.ch)
• Catalogue of IEC publications
The on-line catalogue on the IEC web site (www.iec.ch/catlg-e.htm) enables
you to search by a variety of criteria including text searches, technical
committees and date of publication. On-line information is also available on
recently issued publications, withdrawn and replaced publications, as well as
corrigenda.
• IEC Just Published
This summary of recently issued publications (www.iec.ch/JP.htm) is also
available by email. Please contact the Customer Service Centre (see below) for
further information.
• Customer Service Centre
If you have any questions regarding this publication or need further assistance,
please contact the Customer Service Centre:
Email: custserv@iec.ch
Tel: +41 22 919 02 11
Fax: +41 22 919 03 00
INTERNATIONAL IEC
STANDARD
61156-6-1
First edition
2002-05
Multicore and symmetrical pair/quad cables
for digital communications –
Part 6-1:
Symmetrical pair/quad cables with transmission
characteristics up to 600 MHz –
Work area wiring –
Blank detail specification
Câbles multiconducteurs à paires symétriques et quartes
pour transmissions numériques –
Partie 6-1:
Câbles à paires symétriques et quartes avec caractéristiques
de transmission allant jusqu'à 600 MHz –
Raccordement de terminal –
Spécification particulière cadre
IEC 2002 Copyright - all rights reserved
No part of this publication may be reproduced or utilized in any form or by any means, electronic or
mechanical, including photocopying and microfilm, without permission in writing from the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
PRICE CODE
Commission Electrotechnique Internationale
J
International Electrotechnical Commission
Международная Электротехническая Комиссия
For price, see current catalogue
– 2 – 61156-6-1 IEC:2002(E)
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES
FOR DIGITAL COMMUNICATIONS –
Part 6-1: Symmetrical pair/quad cables with transmission
characteristics up to 600 MHz –Work area wiring –
Blank detail specification
FOREWORD
1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all
national electrotechnical committees (IEC National Committees). The object of the IEC is to promote international
co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in
addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical
committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work.
International, governmental and non-governmental organizations liaising with the IEC also participate in this
preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance
with conditions determined by agreement between the two organizations.
2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all interested
National Committees.
3) The documents produced have the form of recommendations for international use and are published in the form of
standards, technical specifications, technical reports or guides and they are accepted by the National Committees
in that sense.
4) In order to promote international unification, IEC National Committees undertake to apply IEC International Standards
transparently to the maximum extent possible in their national and regional standards. Any divergence between the
IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter.
5) The IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with one of its standards.
6) Attention is drawn to the possibility that some of the elements of this International Standard may be the subject of
patent rights. The IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 61156-6-1 has been prepared by subcommittee 46C: Wires and
symmetric cables, of IEC technical committee 46: Cables, wires, waveguides, RF connectors and
accessories for communication and signalling.
The text of this standard is based on the following documents:
FDIS Report on voting
46C/514/FDIS 46C/522/RVD
Full information on the voting for the approval of this standard can be found in the report on voting
indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The committee has decided that the contents of this publication will remain unchanged until 2006
At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
61156-6-1 IEC:2002(E) – 3 –
MULTICORE AND SYMMETRICAL PAIR/QUAD CABLES
FOR DIGITAL COMMUNICATIONS –
Part 6-1: Symmetrical pair/quad cables with transmission
characteristics up to 600 MHz –Work area wiring –
Blank detail specification
1 Scope
This blank detail specification describes symmetrical pair/quad cables intended to construct patch,
equipment, and work area cords in digital communication systems such as ISDN, local area
networks and data communication systems using frequencies up to 600 MHz.
This specification should be used in conjunction with IEC 61156-1 and IEC 61156-6. The blank
detail specification determines the layout and style for detail specifications describing symmetrical
pair/quad cables with transmission characteristics up to 600 MHz for digital communications. Detail
specifications, based on the blank detail specification, may be prepared by a national organization,
a manufacturer, or a user.
The designation "Category 5e" is used herein to describe an enhanced Category 5 cable (see 1.1
of IEC 61156-6).
2 Normative references
The following referenced documents are indispensable for the application of this document. For
dated references, only the edition cited applies. For undated references, the latest edition of the
referenced document (including any amendments) applies.
IEC 61156-1, Multicore and symmetrical pair/quad cables for digital communications – Part 1:
Generic specification
IEC 61156-6, Multicore and symmetrical pair/quad cables for digital communications – Part 6:
Symmetrical pair/quad cables with transmission characteristics up to 600 MHz – Work area wiring
– Sectional specification
ISO/IEC 11801:2000, Information technology – Generic cabling for customer premises
3 Guidance for preparation of detail specifications
It is necessary to keep the transmission characteristics indicated in the relevant sectional
specification for the referenced category number, i.e. 5e, 6 or 7 and the characteristic impedance.
The detail specification shall be written in accordance with the layout of the blank detail
specification, which forms part of this standard.
NOTE 1 When a characteristic does not apply, then NA (for not applicable) should be entered in the appropriate space.
NOTE 2 When a characteristic applies but a specific value is not considered necessary, then NS (for not specified)
should be entered in the appropriate space. When NS is used, the appropriate requirement in the sectional specification
should apply.
– 4 – 61156-6-1 IEC:2002(E)
The numbers shown in brackets in this and the following pages correspond to the following items
of required information, which should be entered in the spaces provided.
[1] Name and address of the organization that has prepared the document.
[2] IEC document number, issue number and date of issue.
[3] Address of the organization from which the document is available.
[4] Related documents.
[5] Any other reference to the cable, national reference, trade name, etc.
[6] A complete description of the cable whic
...
Frequently Asked Questions
IEC 61156-6-1:2002 is a standard published by the International Electrotechnical Commission (IEC). Its full title is "Multicore and symmetrical pair/quad cables for digital communications - Part 6-1: Symmetrical pair/quad cables with transmission characteristics up to 600 MHz - Work area wiring - Blank detail specification". This standard covers: This blank detail specification describes symmetrical pair/quad cables intended to construct patch, equipment, and work area cords in digital communication systems such as ISDN, local area networks and data communication systems using frequencies up to 600 MHz.
This blank detail specification describes symmetrical pair/quad cables intended to construct patch, equipment, and work area cords in digital communication systems such as ISDN, local area networks and data communication systems using frequencies up to 600 MHz.
IEC 61156-6-1:2002 is classified under the following ICS (International Classification for Standards) categories: 33.120.20 - Wires and symmetrical cables. The ICS classification helps identify the subject area and facilitates finding related standards.
IEC 61156-6-1:2002 has the following relationships with other standards: It is inter standard links to IEC 61156-6-1:2007. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
You can purchase IEC 61156-6-1:2002 directly from iTeh Standards. The document is available in PDF format and is delivered instantly after payment. Add the standard to your cart and complete the secure checkout process. iTeh Standards is an authorized distributor of IEC standards.








Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.
Loading comments...