IEC 60079-27:2005
(Main)Electrical apparatus for explosive gas atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO) and Fieldbus non-incendive concept (FNICO)
Electrical apparatus for explosive gas atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO) and Fieldbus non-incendive concept (FNICO)
This part of IEC 60079 contains the details of apparatus, systems and installation practice for use with the Fieldbus Intrinsically Safe Concept (FISCO) and the Fieldbus Non-Incendive Concept (FNICO). It is based on the concepts of Manchester encoded, bus powered systems designed in accordance with IEC 61158-2 which is the physical layer standard for Fieldbus installations.
Matériel électrique pour atmosphères explosives gazeuses - Partie 27: Concept de réseau de terrain de sécurité intrinsèque (FISCO) et concept de réseau de terrain non incendiaire (FNICO)
Cette partie de la CEI 60079 contient des précisions concernant les matériels, les systèmes et les méthodes d'installation pour utilisation avec le concept de réseau de terrain de sécurité intrinsèque (FISCO) et le concept de réseau de terrain non incendiaire (FNICO). Elle est basée sur les concepts des systèmes d'alimentation en réseau codés en Manchester conçus selon la CEI 61558-2 qui est la norme de la couche physique pour les installations de réseau de terrain.
General Information
Relations
Standards Content (Sample)
NORME CEI
INTERNATIONALE IEC
60079-27
INTERNATIONAL
Première édition
STANDARD
First edition
2005-04
Matériel électrique pour atmosphères
explosives gazeuses –
Partie 27:
Concept de réseau de terrain de sécurité
intrinsèque (FISCO) et concept de réseau
de terrain non incendiaire (FNICO)
Electrical apparatus for explosive
gas atmospheres –
Part 27:
Fieldbus intrinsically safe concept (FISCO)
and Fieldbus non-incendive concept (FNICO)
Numéro de référence
Reference number
CEI/IEC 60079-27:2005
Numérotation des publications Publication numbering
Depuis le 1er janvier 1997, les publications de la CEI As from 1 January 1997 all IEC publications are
sont numérotées à partir de 60000. Ainsi, la CEI 34-1 issued with a designation in the 60000 series. For
devient la CEI 60034-1. example, IEC 34-1 is now referred to as IEC 60034-1.
Editions consolidées Consolidated editions
Les versions consolidées de certaines publications de la The IEC is now publishing consolidated versions of its
CEI incorporant les amendements sont disponibles. Par publications. For example, edition numbers 1.0, 1.1
exemple, les numéros d’édition 1.0, 1.1 et 1.2 indiquent and 1.2 refer, respectively, to the base publication,
respectivement la publication de base, la publication de the base publication incorporating amendment 1 and
base incorporant l’amendement 1, et la publication de the base publication incorporating amendments 1
base incorporant les amendements 1 et 2. and 2.
Informations supplémentaires Further information on IEC publications
sur les publications de la CEI
Le contenu technique des publications de la CEI est The technical content of IEC publications is kept
constamment revu par la CEI afin qu'il reflète l'état under constant review by the IEC, thus ensuring that
actuel de la technique. Des renseignements relatifs à the content reflects current technology. Information
cette publication, y compris sa validité, sont dispo- relating to this publication, including its validity, is
nibles dans le Catalogue des publications de la CEI available in the IEC Catalogue of publications
(voir ci-dessous) en plus des nouvelles éditions, (see below) in addition to new editions, amendments
amendements et corrigenda. Des informations sur les and corrigenda. Information on the subjects under
sujets à l’étude et l’avancement des travaux entrepris consideration and work in progress undertaken by the
par le comité d’études qui a élaboré cette publication, technical committee which has prepared this
ainsi que la liste des publications parues, sont publication, as well as the list of publications issued,
également disponibles par l’intermédiaire de: is also available from the following:
• Site web de la CEI (www.iec.ch) • IEC Web Site (www.iec.ch)
• Catalogue des publications de la CEI • Catalogue of IEC publications
Le catalogue en ligne sur le site web de la CEI The on-line catalogue on the IEC web site
(www.iec.ch/searchpub) vous permet de faire des (www.iec.ch/searchpub) enables you to search by a
recherches en utilisant de nombreux critères, variety of criteria including text searches,
comprenant des recherches textuelles, par comité technical committees and date of publication. On-
d’études ou date de publication. Des informations en line information is also available on recently
ligne sont également disponibles sur les nouvelles issued publications, withdrawn and replaced
publications, les publications remplacées ou retirées, publications, as well as corrigenda.
ainsi que sur les corrigenda.
• IEC Just Published • IEC Just Published
Ce résumé des dernières publications parues This summary of recently issued publications
(www.iec.ch/online_news/justpub) est aussi dispo- (www.iec.ch/online_news/justpub) is also available
nible par courrier électronique. Veuillez prendre by email. Please contact the Customer Service
contact avec le Service client (voir ci-dessous) Centre (see below) for further information.
pour plus d’informations.
• Service clients • Customer Service Centre
Si vous avez des questions au sujet de cette If you have any questions regarding this
publication ou avez besoin de renseignements publication or need further assistance, please
supplémentaires, prenez contact avec le Service contact the Customer Service Centre:
clients:
Email: custserv@iec.ch Email: custserv@iec.ch
Tél: +41 22 919 02 11 Tel: +41 22 919 02 11
Fax: +41 22 919 03 00 Fax: +41 22 919 03 00
.
NORME CEI
INTERNATIONALE IEC
60079-27
INTERNATIONAL
Première édition
STANDARD
First edition
2005-04
Matériel électrique pour atmosphères
explosives gazeuses –
Partie 27:
Concept de réseau de terrain de sécurité
intrinsèque (FISCO) et concept de réseau
de terrain non incendiaire (FNICO)
Electrical apparatus for explosive
gas atmospheres –
Part 27:
Fieldbus intrinsically safe concept (FISCO)
and Fieldbus non-incendive concept (FNICO)
IEC 2005 Droits de reproduction réservés Copyright - all rights reserved
Aucune partie de cette publication ne peut être reproduite ni
No part of this publication may be reproduced or utilized in any
utilisée sous quelque forme que ce soit et par aucun procédé, form or by any means, electronic or mechanical, including
électronique ou mécanique, y compris la photocopie et les photocopying and microfilm, without permission in writing from
microfilms, sans l'accord écrit de l'éditeur. the publisher.
International Electrotechnical Commission, 3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, Switzerland
Telephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch Web: www.iec.ch
CODE PRIX
PRICE CODE N
Pour prix, voir catalogue en vigueur
For price, see current catalogue
– 2 – 60079-27 CEI:2005
SOMMAIRE
AVANT PROPOS . 4
1 Domaine d'application . 8
2 Références normatives . 8
3 Termes et définitions . 10
4 Source d'alimentation . 10
4.1 Généralités. 10
4.2 Exigences supplémentaires pour la source d'alimentation FISCO . 12
4.3 Exigences supplémentaires pour la source d'alimentation FNICO . 12
5 Dispositifs du réseau de terrain . 14
5.1 Généralités. 14
5.2 Dispositifs de terrain FISCO . 14
5.3 Dispositifs de terrain FNICO . 14
6 Bout de ligne . 16
6.1 Généralités. 16
6.2 Bout de ligne FISCO . 16
6.3 Bout de ligne FNICO . 16
7 Exigences du système . 16
7.1 Généralités. 16
7.2 Exigences du système FISCO . 18
7.3 Exigences du système FISCO . 20
8 Marquage . 20
8.1 Marquage FISCO . 20
8.2 Marquage FNICO . 20
9 Exemples de marquage . 22
9.1 Exemples de marquage FISCO . 22
9.2 Exemples de marquage FNICO . 24
10 Diagramme du système . 26
Figure 1 – Système typique . 26
Tableau 1 – Evaluation du courant maximal de sortie approprié aux alimentations à
caractéristique de sortie rectangulaire FISCO . 12
Tableau 2 – Evaluation du courant maximal de sortie approprié aux alimentations à
caractéristique de sortie rectangulaire FNICO . 12
60079-27 IEC:2005 – 3 –
CONTENTS
FOREWORD . 5
1 Scope . 9
2 Normative references . 9
3 Terms and definitions . 11
4 Power supplies . 11
4.1 General . 11
4.2 Additional requirements of FISCO power supplies . 13
4.3 Additional requirements of FNICO power supplies . 13
5 Field devices . 15
5.1 General . 15
5.2 FISCO field devices . 15
5.3 FNICO field devices . 15
6 Terminator . 17
6.1 General . 17
6.2 FISCO terminator . 17
6.3 FNICO terminator . 17
7 System requirements . 17
7.1 General . 17
7.2 FISCO system requirements . 19
7.3 FNICO system requirements. 21
8 Marking . 21
8.1 FISCO marking . 21
8.2 FNICO marking . 21
9 Examples of marking . 23
9.1 Examples of FISCO marking. 23
9.2 Examples of FNICO marking . 25
10 System diagram . 27
Figure 1 – Typical system . 27
Table 1 – Assessment of maximum output current for use with FISCO rectangular
supplies . 13
Table 2 – Assessment of maximum output current for use with FNICO rectangular
supplies . 13
– 4 – 60079-27 CEI:2005
COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE
____________
MATÉRIEL ÉLECTRIQUE POUR ATMOSPHÈRES
EXPLOSIVES GAZEUSES –
Partie 27: Concept de réseau de terrain de sécurité intrinsèque (FISCO)
et concept de réseau de terrain non incendiaire (FNICO)
AVANT PROPOS
1) La Commission Électrotechnique Internationale (CEI) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a
pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les
domaines de l'électricité et de l'électronique. A cet effet, la CEI – entre autres activités – publie des Normes
internationales, des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au
public (PAS) et des Guides (ci-après dénommés "Publication(s) de la CEI"). Leur élaboration est confiée à des
comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les
organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent
également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO),
selon des conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés
sont représentés dans chaque comité d’études.
3) Les Publications de la CEI se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de la CE. Tous les efforts raisonnables sont entrepris afin que la CEI
s'assure de l'exactitude du contenu technique de ses publications; la CEI ne peut pas être tenue responsable
de l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de la CEI s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de la CEI dans leurs publications
nationales et régionales. Toutes divergences entre toutes publications de la CEI et toutes publications
nationales ou régionales correspondantes doivent être indiquée en termes clairs dans cette dernière.
5) La CEI n’a fixé aucune procédure concernant le marquage valant indication d’approbation et n’engage pas sa
responsabilité pour les équipements déclarés conformes à une des ses Publications.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à la CEI, à ses administrateurs, employés, auxiliaires ou
mandataires, y compris ses experts particuliers et les membres de ses comités d'études et des Comités
nationaux de la CEI, pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre
dommage de quelque nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais
de justice) et les dépenses découlant de la publication ou de l'utilisation de cette Publication de la CEI ou de
toute autre Publication de la CEI, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de la CEI peuvent faire
l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour
responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence.
La Norme Internationale CEI 60079-27 a été établie par le sous-comité 31G: Matériels à
sécurité intrinsèque, du comité d’études 31 de la CEI: Matériel électrique pour atmosphères
explosives.
Cette première édition annule et remplace la spécification technique parue en 2002. Elle
constitue une révision technique et a maintenant le statut de Norme Internationale.
60079-27 IEC:2005 – 5 –
INTERNATIONAL ELECTROTECHNICAL COMMISSION
____________
ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES –
Part 27: Fieldbus intrinsically safe concept (FISCO) and
Fieldbus non-incendive concept (FNICO)
FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any
equipment declared to be in conformity with an IEC Publication.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.
International Standard IEC 60079-27 has been prepared by subcommittee 31G: Intrinsically
safe apparatus, of IEC technical committee 31: Electrical apparatus for explosive
atmospheres.
This first edition cancels and replaces the technical specification issued in 2002. It constitutes
a technical revision and now has the status of an International Standard.
– 6 – 60079-27 CEI:2005
Les modifications importantes par rapport à la spécification technique sont indiquées ci-
dessous:
– la norme contient des exigences pour les systèmes des réseaux de terrain non
incendiaires en plus de ceux pour les systèmes de sécurité intrinsèque;
– il y a des modifications mineures dans les paramètres autorisés du câblage, découlant de
la poursuite de travaux expérimentaux.
Le texte de cette norme est issu des documents suivants:
FDIS Rapport de vote
31G/138/FDIS 31G/142/RVD
Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.
Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
La série 60079 contient aussi les normes suivantes (liste non exhaustive), sous le titre
général Matériel électrique pour atmosphères explosives gazeuses:
Partie 25: Systèmes de sécurité intrinsèque
Partie 26: Construction, essais et marquage des matériels électriques de Groupe II
utilisables en Zone 0
Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
maintenance indiquée sur le site web de la CEI sous «http://webstore.iec.ch» dans les
données relatives à la publication recherchée. A cette date, la publication sera
• reconduite;
• supprimée;
• remplacée par une édition révisée, ou
• amendée.
60079-27 IEC:2005 – 7 –
The significant changes with respect to the technical specification are listed below:
− the standard contains the requirements for non-incendive Fieldbus systems in addition to
those for intrinsically safe systems;
− there are small changes in the permitted parameters of field wiring, derived from further
experimental work.
The text of this standard is based on the following documents:
FDIS Report on voting
31G/138/FDIS 31G/142/RVD
Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
The following standards are also part of the same series (non-exhaustive list), under the
general title Electrical apparatus for explosive gas atmospheres:
Part 25: Intrinsically safe systems
Part 26: Construction, test and marking of Group II Zone 0 electrical apparatus
The committee has decided that the contents of this publication will remain unchanged until
the maintenance result date indicated on the IEC web site under "http://webstore.iec.ch" in
the data related to the specific publication. At this date, the publication will be
• reconfirmed;
• withdrawn;
• replaced by a revised edition, or
• amended.
– 8 – 60079-27 CEI:2005
MATÉRIEL ÉLECTRIQUE POUR ATMOSPHÈRES
EXPLOSIVES GAZEUSES –
Partie 27: Concept de réseau de terrain de sécurité intrinsèque (FISCO)
et concept de réseau de terrain non incendiaire (FNICO)
1 Domaine d'application
Cette partie de la CEI 60079 contient des précisions concernant les matériels, les systèmes
et les méthodes d’installation pour utilisation avec le concept de réseau de terrain de sécurité
intrinsèque (FISCO) et le concept de réseau de terrain non incendiaire (FNICO). Elle est
basée sur les concepts des systèmes d’alimentation en réseau codés en Manchester conçus
selon la CEI 61558-2 qui est la norme de la couche physique pour les installations de réseau
de terrain.
Les exigences de construction et d'installation des matériels et des systèmes FISCO et FNICO
sont déterminées par la CEI 60079-11, la CEI 60079-14, la CEI 60079-15 et la CEI 60079-25
à l'exception de ce qui est modifié par la présente norme. Une partie de chacun des
dispositifs de réseau de terrain peut être protégée par l’une ou l’autre des méthodes de
protection contre l’explosion listée dans la CEI 60079-0, appropriée à la Zone d’utilisation
prévue. Dans ces circonstances, les exigences de cette norme s’appliquent uniquement à la
partie du matériel connectée directement à la ligne ou au tronçon de sécurité intrinsèque ou
non incendiaire.
NOTE 1 La certification selon les exigences de FISCO n'empêche pas les matériels d'être également certifiés et
marqués selon la CEI 60079-11 de façon conventionnelle afin qu'ils puissent être utilisés dans d'autres systèmes.
Des matériels certifiés avant la publication de cette norme mais pas nécessairement conformes aux paramètres
électriques de la présente norme peuvent être marqués «Adaptés aux systèmes FISCO». Ces matériels peuvent
être acceptés dans le système FISCO si la comparaison des paramètres électriques U , I , P , avec U , I , P
o o o i i i
démontre la compatibilité avec le reste du système, et que toutes les autres exigences de la présente norme sont
respectées.
NOTE 2 Un système FISCO typique est illustré à l’Article 10.
NOTE 3 Généralement les systèmes FNICO sont destinés à être utilisés dans les emplacements de Zone 2. Les
systèmes FISCO sont destinés principalement pour utilisation en Zone 1 et 2, mais peuvent entrer en Zone 0 si la
documentation l’autorise spécifiquement.
2 Références normatives
Les documents de référence suivants sont indispensables pour l'application du présent
document. Pour les références datées, seule l'édition citée s'applique. Pour les références
non datées, la dernière édition du document de référence s'applique (y compris les éventuels
amendements).
CEI 60050-426, Vocabulaire Electrotechnique International (VEI) – Matériel électrique pour
atmosphères explosives
CEI 60079-0, Matériel électrique pour atmosphères explosives gazeuses – Partie 0: Règles
générales
CEI 60079-11, Matériel électrique pour atmosphères explosives gazeuses – Partie 11:
Sécurité intrinsèque «i»
CEI 60079-14:2002, Matériel électrique pour atmosphères explosives gazeuses – Partie 14:
Installations électriques dans les emplacements dangereux (autres que les mines)
60079-27 IEC:2005 – 9 –
ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES –
Part 27: Fieldbus intrinsically safe concept (FISCO) and
Fieldbus non-incendive concept (FNICO)
1 Scope
This part of IEC 60079 contains the details of apparatus, systems and installation practice for
use with the Fieldbus Intrinsically Safe Concept (FISCO) and the Fieldbus Non-Incendive
Concept (FNICO). It is based on the concepts of Manchester encoded, bus powered systems
designed in accordance with IEC 61158-2 which is the physical layer standard for Fieldbus
installations.
The constructional and installation requirements of FISCO and FNICO apparatus and systems
are determined by IEC 60079-11, IEC 60079-14, IEC 60079-15 and IEC 60079-25, except as
modified by this standard. Part of a Fieldbus device may be protected by any of the methods
of explosion protection listed in IEC 60079-0, appropriate to the Zone of intended use. In
these circumstances, the requirements of this standard apply only to that part of the
apparatus directly connected to the intrinsically safe or non-incendive trunk or spurs.
NOTE 1 Certification to the FISCO requirements does not prevent apparatus also being certified and marked to
IEC 60079-11 in the conventional manner so that they may be used in other systems. Some apparatus certified
before this standard was published but not necessarily complying with the electrical parameters of this standard
may be marked ‘Suitable for FISCO systems’. This apparatus may be accepted in a FISCO system, if the
comparison of the electrical parameters U , I , P , with U , I , P , demonstrate compatibility with the remainder of
o o o i i i
the system, and all the other requirements of this standard are met.
NOTE 2 A typical system is illustrated in Clause 10.
NOTE 3 Generally, FNICO systems are intended for use in Zone 2 locations. FISCO systems are predominantly
intended for use in Zone 1 and 2 locations, but may enter Zone 0 locations if specifically permitted to do so by the
documentation.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition
of the referenced document (including any amendments) applies.
IEC 60050-426, International Electrotechnical Vocabulary (IEV) – Electrical apparatus for
explosive atmospheres
IEC 60079-0, Electrical apparatus for explosive gas atmospheres – Part 0: General
requirements
IEC 60079-11, Electrical apparatus for explosive gas atmospheres – Part 11: Intrinsic safety "i"
IEC 60079-14:2002, Electrical apparatus for explosive gas atmospheres – Part 14: Electrical
installations in hazardous areas (other than mines)
– 10 – 60079-27 CEI:2005
CEI 60079-15, Matériel électrique pour atmosphères explosives gazeuses – Partie 15: Mode
de protection «n»
CEI 60079-25, Matériel électrique pour atmosphères explosives gazeuses – Partie 25:
Systèmes de sécurité intrinsèque
CEI 61158-2, Communications de données numériques pour la mesure et le contrôle – Bus de
terrain utilisé dans les systèmes de contrôle industriel – Partie 2: Spécification de la couche
physique et définition du service (en anglais seulement)
3 Termes et définitions
Pour les besoins du présent document, les termes et définitions de la CEI 60050-426, de la
CEI 60079-0 et de la CEI 60079-11 s’appliquent, ainsi que les suivants:
3.1
FISCO
concept de réseau de terrain de sécurité intrinsèque
3.2
FNICO
concept de réseau de terrain non incendiaire
3.3
non incendiaire
un concept où tout arc ou effet thermique produit dans des conditions voulues de
fonctionnement de l’équipement n’est pas capable, sous des conditions d’essai spécifiées,
d’enflammer le mélange infl
...