EN 60127-4:2005/A2:2013
(Amendment)Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
DOP = DAV + 6 months (D139/C142)
Geräteschutzsicherungen - Teil 4: Welteinheitliche modulare Sicherungseinsätze (UMF) - Bauarten für Steck- und Oberflächenmontage
Coupe-circuit miniatures - Partie 4: Eléments de remplacement modulaires universels (UMF) - Types de montage en surface et montage par trous
Miniaturne varovalke - 4. del: Univerzalni modularni taljivi vložki - Skoznji vložki in vložki za površinsko montažo (IEC 60127-4:2005/A2:2012)
Ta del standarda IEC 60127 se nanaša na univerzalne modularne taljive vložke (UMF) za tiskane tokokroge in sisteme z drugo podlago, ki se uporabljajo za zaščito električnih aparatov, elektronske opreme in delov njenih komponent, ki so namenjeni za notranjo uporabo. Ne velja za taljive vložke za aparate, namenjene uporabi pod posebnimi pogoji, npr. v korozivni ali eksplozivni atmosferi. Te varovalke morajo običajno montirati ali zamenjati samo ustrezno usposobljene osebe s posebno opremo. Taljivi vložki za uporabo v držalih varovalk so v obravnavi. Ta standard se poleg tega uporablja za zahteve iz standarda IEC 60127-1. Cilji tega dela standarda IEC 60127 so enaki, kot je določeno v standardu IEC 60127-1, z dodatno zahtevo stopnje nezmožnosti zamenljivosti.
General Information
- Status
- Published
- Publication Date
- 20-Jun-2013
- Withdrawal Date
- 10-Jan-2016
- Technical Committee
- CLC/SR 32C - Miniature fuses
- Drafting Committee
- IEC/SC 32C - IEC_SC_32C
- Current Stage
- 9093 - Decision to confirm - Review Enquiry
- Start Date
- 05-Jan-2026
- Completion Date
- 13-Jan-2026
Relations
- Effective Date
- 29-Jan-2023
- Effective Date
- 05-Dec-2023
Overview
EN 60127-4:2005/A2:2013 is a European standard that specifies requirements for miniature universal modular fuse-links (UMF) used in electrical and electronic equipment. This amendment enhances Part 4 of the EN 60127 series, which covers both through-hole and surface mount types of UMF fuse-links. The standard aligns with the IEC 60127-4:2005/A2:2012 edition, ensuring harmonization across European and international safety and performance criteria.
The standard aims to standardize the design, testing, and performance of miniature fuse-links to provide reliable overcurrent protection in low-voltage electrical circuits. It supports compliance with safety regulations such as the Low Voltage Directive (LVD 2006/95/EC), thus contributing to device safety and operational integrity.
Key Topics
Scope and Applicability
The document applies to universal modular fuse-links designed for both through-hole and surface mount assembly on printed circuit boards (PCBs). It sets forth test methods, performance requirements, and safety objectives relevant to these components.Fuse-Link Types Covered
- Through-Hole Fuse-Links: Designed for insertion into PCBs via holes, ensuring mechanical stability and electrical connection.
- Surface Mount Fuse-Links: Compact fuse-links for surface mounting, supporting miniaturization and automated assembly.
Testing and Quality Assurance
The amendment updates specific normative references for environmental and solderability testing, including:- IEC 60068-2-20:2008 for solderability and solder heat resistance – ensuring terminals withstand soldering processes without damage.
- IEC 60068-2-58:2004 for surface mount device testing under thermal stress.
Solderability Requirements
Both fuse-link types must be subjected to rigorous solderability tests to ensure solder coatings are smooth, bright, and free from critical imperfections like pinholes or de-wetted areas. These tests guarantee robust electrical connections post-manufacture.Compliance and Implementation Dates
National standard bodies within CENELEC were required to adopt this amendment by December 2013, with conflicting standards withdrawn by January 2016, promoting uniform adherence across member countries.
Practical Applications
Electronic Device Protection
UMF fuse-links complying with EN 60127-4:2005/A2:2013 provide standardized protective solutions against overcurrent in compact electronic equipment, enhancing device longevity and user safety.Automatic Assembly Lines
Specify surface mount types from this standard to streamline automated PCB manufacturing processes, benefiting from tested solderability and thermal resistance characteristics.Design Flexibility
The universal modular fuse-link design facilitates easy replacement and maintenance, reducing downtime in consumer electronics, industrial control systems, and telecommunications hardware.Regulatory Compliance
Using fuse-links that meet EN 60127-4:2005/A2:2013 assists manufacturers in demonstrating compliance with European product safety directives, facilitating market access.
Related Standards
EN 60127 Series
Comprehensive requirements for miniature fuses, covering general terms (Part 1), performance characteristics (Part 2), and other fuse types (Parts 3, 5, etc.)IEC 60068 Series
International standards for environmental testing of electrotechnical equipment, critical for assessing product robustness under soldering and thermal conditions.Low Voltage Directive (LVD 2006/95/EC)
Harmonizes safety objectives for electrical equipment operating within specified voltage limits; this fuse-link standard supports achieving LVD compliance.CENELEC Standards
Integration with other European electrotechnical standards ensures cohesive technical governance across EU member states and associated countries.
Keywords: EN 60127-4:2005/A2:2013, miniature fuses, universal modular fuse-links, UMF, through-hole fuse-links, surface mount fuse-links, CENELEC, IEC 60127-4, solderability testing, overcurrent protection, low voltage directive, electronic safety components, PCB assembly, environmental testing, electrical fuse standards.
Frequently Asked Questions
EN 60127-4:2005/A2:2013 is a amendment published by CLC. Its full title is "Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types". This standard covers: DOP = DAV + 6 months (D139/C142)
DOP = DAV + 6 months (D139/C142)
EN 60127-4:2005/A2:2013 is classified under the following ICS (International Classification for Standards) categories: 29.120.50 - Fuses and other overcurrent protection devices. The ICS classification helps identify the subject area and facilitates finding related standards.
EN 60127-4:2005/A2:2013 has the following relationships with other standards: It is inter standard links to EN 60127-4:2005, FprEN IEC 60127-4:2025. Understanding these relationships helps ensure you are using the most current and applicable version of the standard.
EN 60127-4:2005/A2:2013 is associated with the following European legislation: EU Directives/Regulations: 2006/95/EC, 2014/35/EU. When a standard is cited in the Official Journal of the European Union, products manufactured in conformity with it benefit from a presumption of conformity with the essential requirements of the corresponding EU directive or regulation.
EN 60127-4:2005/A2:2013 is available in PDF format for immediate download after purchase. The document can be added to your cart and obtained through the secure checkout process. Digital delivery ensures instant access to the complete standard document.
Standards Content (Sample)
SLOVENSKI STANDARD
01-september-2013
Miniaturne varovalke - 4. del: Univerzalni modularni taljivi vložki - Skoznji vložki in
vložki za površinsko montažo (IEC 60127-4:2005/A2:2012)
Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface
mount types (IEC 60127-4:2005/A2:2012)
Geräteschutzsicherungen - Teil 4: Welteinheitliche modulare Sicherungseinsätze (UMF)
- Bauarten für Steck- und Oberflächenmontage (IEC 60127-4:2005/A2:2012)
Coupe-circuit miniatures - Partie 4: Eléments de remplacement modulaires universels
(UMF) - Types de montage en surface et montage par trous (CEI 60127-
4:2005/A2:2012)
Ta slovenski standard je istoveten z: EN 60127-4:2005/A2:2013
ICS:
29.120.50 9DURYDONHLQGUXJD Fuses and other overcurrent
PHGWRNRYQD]DãþLWD protection devices
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.
EUROPEAN STANDARD
EN 60127-4/A2
NORME EUROPÉENNE
June 2013
EUROPÄISCHE NORM
ICS 29.120.50
English version
Miniature fuses -
Part 4: Universal modular fuse-links (UMF) -
Through-hole and surface mount types
(IEC 60127-4:2005/A2:2012)
Coupe-circuit miniatures - Geräteschutzsicherungen -
Partie 4: Eléments de remplacement Teil 4: Welteinheitliche modulare
modulaires universels (UMF) - Sicherungseinsätze (UMF) -
Types de montage en surface et montage Bauarten für Steck- und
par trous Oberflächenmontage
(CEI 60127-4:2005/A2:2012) (IEC 60127-4:2005/A2:2012)
This amendment A2 modifies the European Standard EN 60127-4:2005; it was approved by CENELEC on
2013-01-11. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
stipulate the conditions for giving this amendment the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the CEN-CENELEC Management Centre or to any CENELEC member.
This amendment exists in three official versions (English, French, German). A version in any other language
made by translation under the responsibility of a CENELEC member into its own language and notified to the
CEN-CENELEC Management Centre has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus,
the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland,
Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Management Centre: Avenue Marnix 17, B - 1000 Brussels
© 2013 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60127-4:2005/A2:2013 E
Foreword
The text of document 32C/456/CDV, future amendment 2 to edition 3 of IEC 60127-4, prepared by
SC 32C "Miniature fuses" of IEC/TC 32 "Fuses" was submitted to the IEC-CENELEC parallel vote and
approved by CENELEC as EN 60127-4:2005/A2:2013.
The following dates are fixed:
(dop) 2013-12-21
• latest date by which the document has to be
implemented at national level by
publication of an identical national
standard or by endorsement
• latest date by which the national (dow) 2016-01-11
standards conflicting with the
document have to be withdrawn
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such
patent rights.
This standard covers the Principle Elements of the Safety Objectives for Electrical Equipment
Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC).
Endorsement notice
The text of the International Standard IEC 60127-4:2005/A2:2012 was approved by CENELEC as a
European Standard without any modification.
- 3 - EN 60127-4:2005/A2:2013
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications
Replacement in Annex ZA of EN 60127-4:2005:
Publication Year Title EN/HD Year
Replace the reference to IEC 60068-2-20:19
...










Questions, Comments and Discussion