Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The spread frequency shift keying (S-FSK) profile

Describes the requirements of S-FSK (frequency shift keying modulation) in conjunction with the services provided by the physical layer entity and the MAC sublayer. The transmission medium is assumed to be the distribution network on both MV or LV level. To be used in conjunction with EN 61334-4-32.

Verteilungsautomatisierung mit Hilfe von Trägersystemen auf Verteilungsleitungen - Teil 5-1: Profile der unteren Schichten - Profil für erweiterte Frequenzsprungmodulation (S-FSK)

Automatisation de la distribution à l'aide de systèmes de communication à courants porteurs - Partie 5-1: Profils des couches basses - Profil S-FSK (modulation par saut de fréquences étalées)

Décrit les exigences de la modulation S-FSK (spread frequency shift keying - Modulation par déplacement de fréquence étalée) en relation avec les services fournis par la couche physique et la sous-couche MAC. On suppose que le réseau de distribution sur les niveaux MT et BT constitue le support de transmission. Est à lire conjointement avec la EN 61334-4-32.

Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The spread frequency shift keying (S-FSK) profile (IEC 61334-5-1:2001)

General Information

Status
Published
Publication Date
22-Jul-2001
Withdrawal Date
31-May-2004
Current Stage
6060 - Document made available - Publishing
Start Date
23-Jul-2001
Completion Date
23-Jul-2001

Buy Standard

Standard
EN 61334-5-1:2002
English language
65 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljenoReferenčna številkaSIST EN 61334-5-1:2002(en)ICS29.240.99; 33.040.40; 35.100.05

EUROPEAN STANDARDEN 61334-5-1NORME EUROPÉENNEEUROPÄISCHE NORMJuly 2001CENELECEuropean Committee for Electrotechnical StandardizationComité Européen de Normalisation ElectrotechniqueEuropäisches Komitee für Elektrotechnische NormungCentral Secretariat: rue de Stassart 35, B - 1050 Brussels© 2001 CENELEC -All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 61334-5-1:2001 EICS 33.200English versionDistribution automation using distribution line carrier systemsPart 5-1: Lower layer profiles –The spread frequency shift keying (S-FSK) profile(IEC 61334-5-1:2001)Automatisation de la distribution à l'aidede systèmes de communication àcourants porteursPartie 5-1: Profils des couches basses -Profil S-FSK (modulation par saut defréquences étalées)(CEI 61334-5-1:2001)Verteilungsautomatisierung mit Hilfe vonTrägersystemen auf VerteilungsleitungenTeil 5-1: Profile der unteren Schichten -Profil für erweiterte Frequenz-sprungmodulation (S-FSK)(IEC 61334-5-1:2001)This European Standard was approved by CENELEC on 2001-06-01. CENELEC members are bound tocomply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained onapplication to the Central Secretariat or to any CENELEC member.This European Standard exists in three official versions (English, French, German). A version in any otherlanguage made by translation under the responsibility of a CENELEC member into its own language andnotified to the Central Secretariat has the same status as the official versions.CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway,Portugal, Spain, Sweden, Switzerland and United Kingdom.

- 3 -EN 61334-5-1:2001Annex ZA(normative)Normative references to international publicationswith their corresponding European publicationsThis European Standard incorporates by dated or undated reference, provisions from otherpublications. These normative references are cited at the appropriate places in the text and thepublications are listed hereafter. For dated references, subsequent amendments to or revisions of anyof these publications apply to this European Standard only when incorporated in it by amendment orrevision. For undated references the latest edition of the publication referred to applies (includingamendments).NOTEWhen an international publication has been modified by common modifications, indicated by (mod), the relevantEN/HD applies.PublicationYearTitleEN/HDYearIEC 61334-1-41995Distribution automation usingdistribution line carrier systemsPart 1: General considerations –Section 4: Identification of datatransmission parameters concerningmedium and low-voltage distributionmains--IEC 61334-4-11996Part 4: Data communication protocols –Section 1: Reference model of thecommunication systemEN 61334-4-11996IEC 61334-4-321996Section 32: Data link layer - Logical linkcontrol (LLC)EN 61334-4-321996IEC 61334-4-5112000Part 4-511: Data communicationprotocols - Systems management -CIASE protocolEN 61334-4-5112000IEC 61334-4-512- 1)Part 4-512: Data communicationprotocols - Systems management usingprofile 61334-5-1-MIB--ISO/IEC 7498-11994Information technology - Open systemsinterconnection - Basic reference modelThe basic model--ISO/IEC 7498-31997Information technology - Open systemsinterconnection - Basic reference modelNaming and addressing----Signalling on low-voltage electricalinstallations in the frequency range3 kHz to 148,5 kHzPart 1: General requirements, frequencybands and electromagneticdisturbancesEN 50065-1A1A2A31991199219951996
1) To be published.
NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD61334-5-1Deuxième éditionSecond edition2001-05Automatisation de la distribution à l'aide desystèmes de communication à courants porteurs –Partie 5-1:Profils des couches basses –Profil S-FSK (modulation par sautde fréquences étalées)Distribution automation using distributionline carrier systems –Part 5-1:Lower layer profiles –The spread frequency shift keying(S-FSK) profile Commission Electrotechnique Internationale International Electrotechnical CommissionPour prix, voir catalogue en vigueurFor price, see current catalogue© IEC 2001
Droits de reproduction réservés⎯
Copyright - all rights reservedAucune partie de cette publication ne peut être reproduite niutilisée sous quelque forme que ce soit et par aucun procédé,électronique ou mécanique, y compris la photocopie et lesmicrofilms, sans l'accord écrit de l'éditeur.No part of this publication may be reproduced or utilized inany form or by any means, electronic or mechanical,including photocopying and microfilm, without permission inwriting from the publisher.International Electrotechnical Commission3, rue de Varembé
Geneva, SwitzerlandTelefax: +41 22 919 0300e-mail: inmail@iec.ch IEC web site
http://www.iec.chCODE PRIXPRICE CODEXB

61334-5-1 © IEC:2001– 3 –CONTENTSFOREWORD.71General.91.1Scope and object.91.2Normative references.91.3Definitions.112Modulation.112.1Purpose.112.2Spread frequency shift keying (S-FSK) principle.112.3Spreading.152.4Performance tests.152.4.1Purpose.152.4.2White noise BER tests.152.4.3Narrowband interferer BER tests.172.4.4Impulsive noise BER tests.173Physical layer.173.1Purpose.173.2Transmission method.173.2.1Coding.173.2.2Bit timing.173.2.3Frame timing.193.2.4Slot timing.193.3Packet encapsulation.193.3.1Purpose.193.3.2Byte and bit ordering.193.3.3Preamble and start subframe delimiter.213.3.4Pause.213.4Physical layer services definitions.213.4.1General description.213.4.2P_Data.request.233.4.3P_Data.confirm.253.4.4P_Data.indication.253.4.5P_Sync.request.273.4.6P_Sync.indication.273.5Sending and receiving physical sublayer.293.5.1Sending.293.5.2Receiving.293.5.3Synchronization – desynchronization of a server.313.5.4Physical state transition tables.333.5.5Transition table description.35

61334-5-1 © IEC:2001– 5 –4Medium access control sublayer (MAC).454.1MAC service specification.454.1.1Purpose.454.1.2Characteristics.454.1.3Overview of the services.454.1.4MA_Data.request.474.1.5MA_Data.confirm.494.1.6MA_Data.indication.514.1.7MA_Sync.indication.534.2MAC frame structure.554.2.1Frame indicator.574.2.2Long MAC frame format.574.2.3Elements of the long MAC frame.654.2.4Invalid long MAC frame.754.3Medium access control method.754.3.1Functional model.754.3.2Transmission description.774.3.3Reception description.774.3.4MAC management description.774.3.5Formal specification.774.3.6Medium access state table.794.3.7Transition table description.97Annex A (normative)
Description of error values.119Bibliography.123Figure 1 – Quality "space" similar to quality "mark".13Figure 2 – Quality "mark" much better than quality "space".13Figure 3 – Time slot and physical frame structure.19Figure 4 – P_Data services.23Figure 5 – Relationship with reference model.45Figure 6 – MA_Data service primitives.47Figure 7 – MAC subframe format.57Figure 8 – Long MAC frame made of one subframe only.59Figure 9 – Long MAC frame made of two subframes.61Figure 10 – Long MAC frame made of more than two subframes.
...

Questions, Comments and Discussion