Information technology - Data centre facilities and infrastructures - Part 4-31: Key performance indicators for Resilience

This document a) defines metrics as key performance indicators (KPIs) for resilience, dependability, fault tolerance and availability tolerance for data centres; b) covers the data centre infrastructure (DCI) of power distribution and supply, and environmental control; c) can be referred to for covering further infrastructures, e.g. telecommunications cabling; d) defines the measurement and calculation of the metrics and resilience levels (RLs); e) targets maintainability, recoverability and vulnerability; f) provides examples for calculating these KPIs for the purpose of analytical comparison of different DCIs. This document does not apply to IT equipment, cloud services, software or business applications.

Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-31: Leistungskennzahlen für die Ausfallsicherheit

Technologie de l’information - Installation et infrastructures de centres de traitement de données - Partie 4-31: Indicateurs-clés de performance pour la résilience

Le présent document: a) définit les métriques constituant des indicateurs-clés de performance (KPI) pour la résilience, la sûreté de fonctionnement, la tolérance aux pannes et la tolérance de disponibilité des centres de traitement de données; b) couvre l’infrastructure de centre de traitement de données (DCI) concernant l’alimentation et la distribution de l’énergie, et le contrôle environnemental; c) peut constituer une référence pour traiter des autres infrastructures, par exemple celles concernant le câblage de télécommunications; d) définit les modes de mesure et de calcul des métriques et des niveaux de résilience (RL); e) cible la maintenabilité, la récupérabilité et la vulnérabilité; f) donne des exemples pour calculer ces KPI à des fins de comparaison analytique de différentes DCI. Le présent document ne s’applique pas aux équipements de traitement de l’information, aux services cloud, aux logiciels ni aux applications métier.

Informacijska tehnologija - Naprave in infrastruktura podatkovnega centra - 4-31. del: Ključni kazalniki uspešnosti za odpornost

General Information

Status
Not Published
Publication Date
19-Sep-2024
Current Stage
5020 - Vote circulated - Formal Approval
Start Date
03-May-2024
Due Date
23-Dec-2024
Completion Date
03-May-2024

Buy Standard

Draft
kTS CLC/FprTS 50600-4-31:2024
English language
66 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)

SLOVENSKI STANDARD
kSIST-TS CLC/FprTS 50600-4-31:2024
01-junij-2024
Informacijska tehnologija - Naprave in infrastruktura podatkovnega centra - 4-31.
del: Ključni kazalniki uspešnosti za odpornost
Information technology - Data centre facilities and infrastructures - Part 4-31: Key
performance indicators for Resilience
Informationstechnik - Einrichtungen und Infrastrukturen von Rechenzentren - Teil 4-31:
Leistungskennzahlen für die Ausfallsicherheit
Technologie de l’information - Installation et infrastructures de centres de traitement de
données - Partie 4-31: Indicateurs-clés de performance pour la résilience
Ta slovenski standard je istoveten z: CLC/FprTS 50600-4-31:2024
ICS:
35.020 Informacijska tehnika in Information technology (IT) in
tehnologija na splošno general
35.110 Omreževanje Networking
35.160 Mikroprocesorski sistemi Microprocessor systems
kSIST-TS CLC/FprTS 50600-4-31:2024 en
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

---------------------- Page: 1 ----------------------
kSIST-TS CLC/FprTS 50600-4-31:2024

---------------------- Page: 2 ----------------------
kSIST-TS CLC/FprTS 50600-4-31:2024


TECHNICAL SPECIFICATION FINAL DRAFT
CLC/FprTS 50600-4-31
SPÉCIFICATION TECHNIQUE

TECHNISCHE SPEZIFIKATION

May 2024
ICS 35.020; 35.110; 35.160 -
English Version
Information technology - Data centre facilities and infrastructures
- Part 4-31: Key performance indicators for Resilience
Technologie de l'information - Installation et infrastructures Informationstechnik - Einrichtungen und Infrastrukturen von
de centres de traitement de données - Partie 4-31: Rechenzentren - Teil 4-31: Leistungskennzahlen für die
Indicateurs-clés de performance pour la résilience Ausfallsicherheit
This draft Technical Specification is submitted to CENELEC members for vote by correspondence.
Deadline for CENELEC: 2024-07-26.

It has been drawn up by CLC/TC 215.

CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic,
Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the
Netherlands, Norway, Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland,
Türkiye and the United Kingdom.

Recipients of this draft are invited to submit, with their comments, notification of any relevant patent rights of which they are aware and to
provide supporting documentation.

Warning : This document is not a Technical Specification. It is distributed for review and comments. It is subject to change without notice
and shall not be referred to a Technical Specification.



European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2024 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members.
Project: 78173 Ref. No. CLC/FprTS 50600-4-31:2024 E

---------------------- Page: 3 ----------------------
kSIST-TS CLC/FprTS 50600-4-31:2024
CLC/FprTS 50600-4-31:2024 (E)
1 Contents Page
2 European Foreword . 3
3 Introduction . 4
4 1 Scope . 7
5 2 Normative references . 7
6 3 Terms, Definitions, Abbreviations and Symbols . 7
7 3.1 Terms and Definitions . 7
8 3.2 Abbreviations .12
9 3.3 Symbols .12
10 4 Area application . 14
11 4.1 General .14
12 4.2 DCI service definition .14
13 5 Resilience considerations as part of the life cycle .
...

Questions, Comments and Discussion

Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.