Building hardware - Hardware for windows and door height windows - Requirements and test methods - Part 13: Sash balances

This document specifies requirements and test methods for durability, strength, security and function of sash balances.

Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und Prüfverfahren - Teil 13: Ausgleichgewichte für Vertikal-Schiebefenster

Dieses Dokument legt die Anforderungen und Prüfverfahren für die Dauerfunktionsfähigkeit, Festigkeit, Schutzwirkung und Funktion von Ausgleichgewichten fest.

Quincaillerie pour le bâtiment - Ferrures de fenêtres et portes-fenêtres - Exigences et méthodes d'essai - Partie 13: Contrepoids pour mécanismes à guillotine

Le présent document spécifie les exigences et les méthodes d'essai relatives à l’endurance, à la résistance, à la sécurité des biens et au fonctionnement des contrepoids pour mécanisme à guillotine.

Stavbno okovje - Okovje za okna in zastekljena vrata - Zahteve in preskusne metode - 13. del: Ravnotežje drsnih oken

Ta dokument določa zahteve in preskusne metode za trajnost, trdnost, varnost ter funkcionalnost ravnotežja drsnih oken.

General Information

Status
Published
Publication Date
25-Jan-2022
Withdrawal Date
30-Jul-2022
Current Stage
6060 - Definitive text made available (DAV) - Publishing
Start Date
26-Jan-2022
Due Date
30-Jun-2022
Completion Date
26-Jan-2022

Relations

Buy Standard

Standard
EN 13126-13:2022
English language
15 pages
sale 10% off
Preview
sale 10% off
Preview
e-Library read for
1 day

Standards Content (Sample)


SLOVENSKI STANDARD
01-maj-2022
Nadomešča:
SIST EN 13126-13:2012
Stavbno okovje - Okovje za okna in zastekljena vrata - Zahteve in preskusne
metode - 13. del: Ravnotežje drsnih oken
Building hardware - Hardware for windows and door height windows - Requirements and
test methods - Part 13: Sash balances
Baubeschläge - Beschläge für Fenster und Fenstertüren - Anforderungen und
Prüfverfahren - Teil 13: Ausgleichgewichte für Vertikal-Schiebefenster
Quincaillerie pour le bâtiment - Ferrures de fenêtres et portes-fenêtres - Exigences et
méthodes d'essai - Partie 13: Contrepoids pour mécanismes à guillotine
Ta slovenski standard je istoveten z: EN 13126-13:2022
ICS:
91.190 Stavbna oprema Building accessories
2003-01.Slovenski inštitut za standardizacijo. Razmnoževanje celote ali delov tega standarda ni dovoljeno.

EN 13126-13
EUROPEAN STANDARD
NORME EUROPÉENNE
January 2022
EUROPÄISCHE NORM
ICS 91.190 Supersedes EN 13126-13:2012
English Version
Building hardware - Hardware for windows and door
height windows - Requirements and test methods - Part
13: Sash balances
Quincaillerie pour le bâtiment - Ferrures de fenêtres et Baubeschläge - Beschläge für Fenster und Fenstertüren
portes-fenêtres - Partie 13 : Exigences et méthodes - Anforderungen und Prüfverfahren - Teil 13:
d'essai - Partie 13 : Contrepoids pour mécanismes à Ausgleichgewichte für Vertikal Schiebefenster
guillotine
This European Standard was approved by CEN on 19 December 2021.

CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this
European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references
concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN
member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by
translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management
Centre has the same status as the official versions.

CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,
Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway,
Poland, Portugal, Republic of North Macedonia, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and
United Kingdom.
EUROPEAN COMMITTEE FOR STANDARDIZATION
COMITÉ EUROPÉEN DE NORMALISATION

EUROPÄISCHES KOMITEE FÜR NORMUNG

CEN-CENELEC Management Centre: Rue de la Science 23, B-1040 Brussels
© 2022 CEN All rights of exploitation in any form and by any means reserved Ref. No. EN 13126-13:2022 E
worldwide for CEN national Members.

Contents Page
European foreword . 3
1 Scope . 6
2 Normative references . 6
3 Terms and definitions . 6
4 Classification . 6
4.1 General . 6
4.2 Durability (1 – first box) . 7
4.3 Mass (2 – second box) . 7
4.4 Corrosion resistance (3 – third box) . 7
4.5 Test Sizes (4 – fourth box) . 7
4.6 Rating (5 – fifth box) . 7
4.7 Example of classification for sash balances . 7
5 Requirements . 8
5.1 Dangerous substances . 8
5.2 Integrated maximum opening stop . 8
5.3 Free movement test . 8
5.4 Durability . 8
5.5 Rating – Resistance to manually applied load test . 8
5.6 Corrosion resistance test . 9
6 Test equipment and preparation for the test . 9
6.1 Sash balances installed in the test specimen . 9
6.2 Test specimens from the sash balance manufacturer . 9
6.3 Test rig . 9
6.4 Hardware . 9
7 Test methods . 10
7.1 Samples . 10
7.2 Free movement test procedure . 10
7.3 Durability . 10
7.3.1 Durability test procedure . 10
7.3.2 Durability test – acceptance criteria . 10
7.4 Resistance to manually applied load test procedure . 11
7.5 Corrosion resistance test . 11
8 Marking . 11
Annex A (informative) Test procedures . 12
Annex B (informative) Flowchart of test procedure . 14
Bibliography . 15

European foreword
This document (EN 13126-13:2022) has been prepared by Technical Committee CEN/TC 33 “Doors,
windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR.
This European Standard shall be given the status of a national standard, either by publication of an
identical text or by endorsement, at the latest by July 2022, and conflicting national standards shall be
withdrawn at the latest by July 2022.
Attention is drawn to the possibility that some of the elements of this document may be the subject of
patent rights. CEN shall not be held responsible for identifying any or all such patent rights.
The performance tests incorporated in this document are considered to be reproducible and as such will
provide a consistent and objective assessment of the performance of these products throughout CEN
Member States.
This document supersedes EN 13126-13:2012.
With regard to EN 13126-13:2012, the following significant changes were made:
— EN 13126-13 is now independent from EN 13126-1; all necessary information is included without
the need of any further information from EN 13126-1;
— several editorial changes in the wording for a better understanding;
— new terms and definitions added under 3.3 (sash width) and 3.4 (sash height);
— under 4.1 classification system changed completely:
— former digit 1 (Category of use) changed into box 1 (Durability);
— former digit 2 (Durability) changed into box 2 (Mass);
— former digits 3, 4 and 5 deleted;
— former digit 6 (Corrosion resistance) changed into box 3 (Corrosion resistance);
— former digits 7 deleted;
— former digit 8 (Application) changed into box 4 (Test sizes);
— former digit 9 (Test sizes) changed into box 5 (Rating);
— under 4.2 new grades for the number of cycles defined; H1 (5 000), H2 (10 000) and H3 (20 000);
— under 4.7 new example of classification added in accordance with the new classification system; two
alternative ways (table or alphanumerical) to show the classification defined;
— under 5.4 information regarding new grades for durability added;
— under 5.5 headline and grades in Table 3 modified;
— under 5.6 the wording changed and information regarding corrosion resistance added;
— under Clause 6 headline modified;
— under 6.2 wording modified; new sentence added at the beginning;
— under 7.1 wording modified;
— under 7.3 several changes in the structure and the wording;
— under 7.3.1 headline modified;
— under 7.3.2 new headline added for a new subclause with the acceptance criteria;
— under 7.5 new subclause added with information regarding corrosion resistance;
— under Clause 8 new clause added regarding marking with information from the current version of
EN 13126-1.
This document is one of a series of European Standards for building hardware products for windows and
door height windows. This document is independent of EN 13126-1.
EN 13126 consists of the following parts:
— EN 13126-1, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 1: Requirements common to all types of hardware;
— EN 13126-2, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 2: Window fastener handles;
— EN 13126-3, Building hardware — Hardware for windows and door-height windows — Requirements
and test methods — Part 3: Handles, primarily for Tilt and Turn, Tilt-First and Turn-Only hardware;
— EN 13126-4, Building hardware — Requirements and test methods for windows and door height
windows — Part 4: Espagnolettes;
— EN 13126-5, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 5: Devices that restrict the opening of windows and door height windows;
— EN 13126-6, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 6: Variable geometry stay hinges (with or without a friction stay);
— EN 13126-7, Building hardware — Requirements and test methods for windows and door height
windows — Part 7: Finger catches;
— EN 13126-8, Building hardware — Hardware for windows and door height windows — Part 8:
Requirements and test methods for tilt and turn, Tilt-First and Turn-Only hardware;
— EN 13126-9, Building hardware — Requirements and test methods for windows and door height
windows — Part 9: Hardware for horizontal and vertical pivot windows;
— EN 13126-10, Building hardware — Requirements and test methods for windows and door height
windows — Part 10: Arm-balancing systems;
— EN 13126-11, Building hardware — Requirements and test methods for windows and door height
windows — Part 11: Top hung projecting reversible hardware;
— EN 13126-12, Building hardware — Requirements and test methods for windows and door height
windows — Part 12: Side hung projecting reversible hardware;
— EN 13126-13, Building hardware — Hardware for windows and balcony door — Requirements and
test methods — Part 13: Sash balances;
— EN 13126-14, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 14: Sash fasteners;
— EN 13126-15, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 15: Rollers for sliding and hardware for sliding folding windows;
— EN 13126-16, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 16: Hardware for Lift and Slide windows;
— EN 13126-17, Building hardware — Hardware for windows and door height windows — Requirements
and test methods — Part 17: Hardware for Tilt and Slide windows;
— EN 13126-19, Building hardware
...

Questions, Comments and Discussion