Standard Specification for Solid Concrete Interlocking Paving Units

SCOPE
1.1 This specification covers the requirements for interlocking concrete pavers manufactured for the construction of paved surfaces.
1.2 When particular features are desired, such as weight classification, higher compressive strength, surface textures, finish, color, or other special features, such properties should be specified by the purchaser. Local sellers, however, should be consulted as to availability of units having the desired features.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

General Information

Status
Historical
Publication Date
31-May-2007
Current Stage
Ref Project

Relations

Buy Standard

Technical specification
ASTM C936-07 - Standard Specification for Solid Concrete Interlocking Paving Units
English language
2 pages
sale 15% off
Preview
sale 15% off
Preview

Standards Content (Sample)

NOTICE: This standard has either been superseded and replaced by a new version or withdrawn.
Contact ASTM International (www.astm.org) for the latest information
Designation: C 936 – 07
Standard Specification for
1
Solid Concrete Interlocking Paving Units
This standard is issued under the fixed designation C 936; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
1. Scope C 989 Specification for Ground Granulated Blast-Furnace
Slag for Use in Concrete and Mortars
1.1 This specification covers the requirements for interlock-
C 1157 Performance Specification for Hydraulic Cement
ingconcretepaversmanufacturedfortheconstructionofpaved
C 1240 Specification for Silica Fume Used in Cementitious
surfaces.
Mixtures
1.2 When particular features are desired, such as weight
classification, higher compressive strength, surface textures,
3. Terminology
finish, color, or other special features, such properties should
3.1 Definitions:
bespecifiedbythepurchaser.Localsellers,however,shouldbe
3.1.1 architectural finishes—surface modified by mechani-
consulted as to availability of units having the desired features.
cal means such as blasting, hammering, polishing, tumbling,
1.3 The values stated in SI units are to be regarded as the
washing, or other methods.
standard. The values given in parentheses are for information
only.
4. Materials
2. Referenced Documents 4.1 Cementitious Materials shall conform to the following
2 applicable ASTM specifications:
2.1 ASTM Standards:
4.1.1 Portland Cements—Specification C 150.
C33 Specification for Concrete Aggregates
4.1.2 Blended Cements—Specification C 595, Types IS or
C67 Test Methods for Sampling and Testing Brick and
IP.
Structural Clay Tile
4.1.3 Hydraulic Cement—Specification C 1157.
C 140 Test Methods for Sampling and Testing Concrete
4.1.4 Hydrated Lime, Type S—Specification C 207.
Masonry Units and Related Units
4.1.5 Fly Ash—Specification C 618.
C 150 Specification for Portland Cement
4.1.6 Ground Slag—Specification C 989.
C 207 Specification for Hydrated Lime for Masonry Pur-
4.1.7 Silica Fume—Specification C 1240.
poses
4.2 Aggregates shall conform to the following ASTM
C 260 Specification forAir-EntrainingAdmixtures for Con-
specifications, except that grading requirements shall not
crete
necessarily apply:
C 331 Specification for Lightweight Aggregates for Con-
4.2.1 Normal Weight—SpecificationC33.
crete Masonry Units
4.2.2 Lightweight—Specification C 331.
C 418 Test Method forAbrasion Resistance of Concrete by
4.3 Chemical Admixtures shall conform to the following
Sandblasting
applicable ASTM specifications:
C 494/C 494M Specification for Chemical Admixtures for
4.3.1 Air-entraining Admixtures—Specification C 260.
Concrete
4.3.2 Water-reducing, Retarding, and Accelerating
C 595 Specification for Blended Hydraulic Cements
Admixtures—Specification C 494/C 494M.
C 618 Specification for Coal Fly Ash and Raw or Calcined
4.3.3 Pigments for Integrally Colored Concrete—
Natural Pozzolan for Use in Concrete
Specification C 979.
C 979 Specification for Pigments for Integrally Colored
4.4 Other Constituents—Integral water repellents, and other
Concrete
materials for which no ASTM standards exist, shall be previ-
ously established as suitable for use in concrete or shall be
1
This specification is under the jurisdiction ofASTM Committee C27 on Precast
shown by test or experience not to be detrimental to the
Concrete Products and is the direct responsibility of Subcommittee C27.20 on
concrete.
Architectural and Structural Products.
Current edition approved June 1, 2007. Published June 2007. Originally
5. Physical Requirements
approved in 1982. Last previous edition approved in 2001 as C 936 – 01.
2
For referenced ASTM standards, visit the ASTM website, www.astm.org, or 2
5.1 Units shall have an exposed face area#0.065 m (101
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM
2
in. ), and their overall length divided by thickness shall be#4.
Standards volume information, refer to the standard’s Document Summary page on
the ASTM website. The minimum thickness shall be 60 mm (2.36 in.). See Fig. 1.
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
1

---------------------- Page: 1 ----------------------
C936–07
5.7 Dimensional Tolerance—Length or width of units shall
not differ by more than 61.6 mm (60.063 in.) from approved
samples. Heights of units shall not differ more than 63.2 mm
(60.125in.)thespecifiedstandarddimension.Alltestsshallbe
performed as required in 6.2. Units shall meet dimensional
tolerances prior to the application of architectural finishes.
6. Sampling and Testing
6.1 The purchaser or his authorized representative shall be
accorded proper facilities to inspect and
...