This document specifies requirements for thedevelopment and validation of processes for packaging medical devices that areterminally sterilized. These processes include forming, sealing and assembly ofpreformed sterile barrier systems, sterile barrier systems and packagingsystems. It is applicable to industry, to health care facilities, and towherever medical devices are packaged and sterilized. It does not cover allrequirements for packaging medical devices that are manufactured aseptically.Add...view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      26 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use. It is applicable to industry, to health care facilities, and to wherever medical devices are placed in sterile barrier systems and sterilized. It does not cover all requirements for sterile barrier systems and packaging systems for medical devic...view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      52 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use.
It is applicable to industry, to health care facilities, and to wherever medical devices are placed in sterile barrier systems and sterilized.
It does not cover all requirements for sterile barrier systems and packaging systems for medical dev...
view more

    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Standard
      52 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      52 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems.
It is applicable to industry, to health care facilities, and to wherever medical devices are packaged and sterilized.
It does not cover all requirements for packaging medical devices that are manufactured aseptic...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day
    • sale 10% off
    • Draft
      26 pages
      English language
    • e-Library read for
      1 day

This document specifies the characteristics of sterile and ready for filling empty glass cartridges for injectable preparations, including the minimum requirements of materials, packaging systems and analytical test methods.

    • sale 15% off
    • Standard
      28 pages
      English language

This document specifies the characteristics of sterile and ready for filling empty glass vials for injectable preparations, including the minimum requirements of materials, packaging systems and analytical test methods.

    • sale 15% off
    • Standard
      20 pages
      English language

This part of EN 868 provides test methods and values for re-usable containers used as sterile barrier systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use. These containers are intended to be used in steam sterilizers conforming to EN 285.
NOTE 1 The need for a packaging material inside the container is determined by the manufactures and users.
This part of EN 868 only introduces performance requirements and test methods that are specific...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This part of EN 868 provides test methods and values for sealable pouches and reels manufactured from porous materials complying with either EN 868 part 2, 3, 6, 7, 9 or 10 and plastic film complying with Clause 4 used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
NOTE 1 The need for a protective packaging may be determined by the manufacturer and the user. This part of EN 868 only introd...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This document specifies test methods and values for sealable adhesive coated nonwoven materials of
polyolefines, manufactured from nonwovens complying with EN 868-9 used for sterile barrier systems
and/or packaging systems that are intended to maintain sterility of terminally sterilized medical
devices to the point of use.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2 this part of
EN 868 specifies materials, test methods and values that are specific t...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This document specifies test methods and values for uncoated nonwoven materials of polyolefines used
for sterile barrier systems and/or packaging systems that are intended to maintain sterility of
terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607-1 and EN ISO 11607-2 this part of
EN 868 specifies materials, test methods and values that are specific to the products covered by this
document.
The materials specified in ...
view more

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This document specifies requirements for the development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing and assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems. It is applicable to industry, to health care facilities, and to wherever medical devices are packaged and sterilized. It does not cover all requirements for packaging medical devices that are manufactured aseptical...view more

    • sale 15% off
    • Standard
      14 pages
      French language
    • sale 15% off
    • Standard
      13 pages
      English language

This document specifies requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain sterility of terminally sterilized medical devices until the point of use. It is applicable to industry, to health care facilities, and to wherever medical devices are placed in sterile barrier systems and sterilized. It does not cover all requirements for sterile barrier systems and packaging systems for medical devic...view more

    • sale 15% off
    • Standard
      62 pages
      French language
    • sale 15% off
    • Standard
      44 pages
      English language

This document specifies test methods and values for sealable adhesive coated nonwoven materials of polyolefines, manufactured from nonwovens complying with FprEN 868 9 used for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of EN 868 specifies materials, test methods and values that are specific to...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This document specifies test methods and values for uncoated nonwoven materials of polyolefines used for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of EN 868 specifies materials, test methods and values that are specific to the products covered by this European Standard.
The materials specifie...
view more

    • sale 10% off
    • Standard
      9 pages
      English language
    • e-Library read for
      1 day

This document specifies test methods and values for sealable pouches and reels manufactured from porous materials complying with either EN 868 part 2, 3, 6, 7, 9 or 10 and plastic film complying with Clause 4. These sealable pouches and reels are used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this pa...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This document specifies test methods and values for re-usable containers used as sterile barrier systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use. These containers are intended to be used in steam sterilizers conforming to EN 285.
NOTE 1   The need for a packaging material inside the container is determined by the manufacturers and users.
Other than the general requirements as specified in EN ISO 11607 1 and EN ISO 11607 2 this part of ...
view more

    • sale 10% off
    • Standard
      21 pages
      English language
    • e-Library read for
      1 day

This draft European Standard provides test methods and values for materials for sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but does not add or modify the gener...
view more

    • sale 10% off
    • Standard
      23 pages
      English language
    • e-Library read for
      1 day

This draft European Standard provides test methods and values for paper, used in the manufacture of paper bags (specified in EN 868-4) and in the manufacture of pouches and reels (specified in EN 868-5) used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance ...
view more

    • sale 10% off
    • Standard
      19 pages
      English language
    • e-Library read for
      1 day

This draft European Standard provides test methods and values for paper bags manufactured from paper specified in EN 868-3, used as sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this...
view more

    • sale 10% off
    • Standard
      14 pages
      English language
    • e-Library read for
      1 day

This draft European Standard provides test methods and values for paper used in the manufacture of preformed sterile barrier systems and/or packaging systems that are intended to maintain sterility of terminally sterilized medical devices to the point of use.
The need for a protective packaging may be determined by the manufacturer and the user.
This part of EN 868 only introduces performance requirements and test methods that are specific to the products covered by this part of EN 868 but doe...
view more

    • sale 10% off
    • Standard
      19 pages
      English language
    • e-Library read for
      1 day