M/256 - SO2, NO2, CO & 03 -ambiant air
Standardization mandate to CEN for standard measuring methods of SO2, NO2, CO, 03 in ambiant air
General Information
This document specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an anayser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air from 0 mg/m3 to 1 000 mg/m3 sulphur dioxide. This concentration range represents the certification range for the type approval test.
NOTE 1 0 mg/m3 to 1 000 mg/m3 of SO2 corresponds to 0 nmol/mol to 376 nmol/mol of SO2.
NOTE 2 Lower ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The method covers the determination of ambient air concentrations of sulphur dioxide in zones classified as rural areas, urban-background areas and traffic-orientated locations.
The results are expressed in mg/m3 (at 293 K and 101,3 kPa).
When the standard is used for other purposes than the EU-directive, the range and uncertainty requirements need not apply.
- Standard103 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of carbon monoxide present in ambient air based on the non-dispersive infrared measuring principle (NDIR). This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate non-dispersive infrared carbon monoxide analyser by means of type approval tests. It also includes the evaluation of the suitability of an anayser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance.
The method is applicable to the determination of the mass concentration of carbon monoxide present in ambient air in the range from 0 mg/m3 to 100 mg/m3 carbon monoxide. This concentration range represents the certification range for the type approval test.
NOTE 1 0 mg/m3 to 100 mg/m3 of CO corresponds to 0 mmol/mol to 86 mmol/mol of CO.
The method covers the determination of ambient air concentrations of carbon monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations.
NOTE 2 Other ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The results are expressed in mg/m3 (at 293 K and 101,3 kPa).
When the standard is used for other purposes than the EU directive, the range and uncertainty requirements need not apply.
- Standard86 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of ozone present in ambient air based on the ultraviolet photometric measuring principle. This document describes the performance characteristics, and sets the relevant minimum criteria required to select an appropriate ultraviolet photometric ozone analyser by means of type approval tests. It also includes the evaluation of the suitability of an anayser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance.
The method is applicable to the determination of the mass concentration of ozone present in ambient air in the range from 0 mg/m3 to 500 mg/m3. This concentration range represents the certification range for the type approval test.
NOTE 1 0 mg/m3 to 500 mg/m3 of O3 corresponds to 0 nmol/mol to 250 nmol/mol of O3.
The method covers the determination of ambient air concentrations of ozone in zones classified as rural areas, urban and urban-background areas.
NOTE 2 Other ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The results are expressed in mg/m3 (at 20 °C and 101,3 kPa).
When the standard is used for other purposes than the EU-directive, the range and uncertainty requirements need not apply.
- Standard87 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance.
The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air from 0 mg/m3 to 500 mg/m3. This concentration range represents the certification range for NO2 for the type approval test.
NOTE 1 0 mg/m3 to 500 mg/m3 of NO2 corresponds to 0 nmol/mol to 261 nmol/mol of NO2.
The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air from 0 mg/m3 to 1 200 mg/m3. This concentration range represents the certification range for NO for the type approval test.
NOTE 2 0 mg/m3 to 1 200 mg/m3 of NO corresponds to 0 nmol/mol to 962 nmol/mol of NO.
The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations.
NOTE 3 Lower ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The results are expressed in mg/m3 (at 293 K and 101,3 kPa).
When the standard is used for other purposes than the EU Directive, the range and uncertainty requirements need not apply.
- Standard92 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of carbon monoxide present in ambient air based on the non-dispersive infrared measuring principle (NDIR). This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate non-dispersive infrared carbon monoxide analyser by means of type approval tests. It also includes the evaluation of the suitability of an anayser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance.
The method is applicable to the determination of the mass concentration of carbon monoxide present in ambient air in the range from 0 mg/m3 to 100 mg/m3 carbon monoxide. This concentration range represents the certification range for the type approval test.
NOTE 1 0 mg/m3 to 100 mg/m3 of CO corresponds to 0 mmol/mol to 86 mmol/mol of CO.
The method covers the determination of ambient air concentrations of carbon monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations.
NOTE 2 Other ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The results are expressed in mg/m3 (at 293 K and 101,3 kPa).
When the standard is used for other purposes than the EU directive, the range and uncertainty requirements need not apply.
- Standard86 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of ozone present in ambient air based on the ultraviolet photometric measuring principle. This document describes the performance characteristics, and sets the relevant minimum criteria required to select an appropriate ultraviolet photometric ozone analyser by means of type approval tests. It also includes the evaluation of the suitability of an anayser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance.
The method is applicable to the determination of the mass concentration of ozone present in ambient air in the range from 0 mg/m3 to 500 mg/m3. This concentration range represents the certification range for the type approval test.
NOTE 1 0 mg/m3 to 500 mg/m3 of O3 corresponds to 0 nmol/mol to 250 nmol/mol of O3.
The method covers the determination of ambient air concentrations of ozone in zones classified as rural areas, urban and urban-background areas.
NOTE 2 Other ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The results are expressed in mg/m3 (at 20 °C and 101,3 kPa).
When the standard is used for other purposes than the EU-directive, the range and uncertainty requirements need not apply.
- Standard87 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an anayser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance for use.
The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air from 0 mg/m3 to 1 000 mg/m3 sulphur dioxide. This concentration range represents the certification range for the type approval test.
NOTE 1 0 mg/m3 to 1 000 mg/m3 of SO2 corresponds to 0 nmol/mol to 376 nmol/mol of SO2.
NOTE 2 Lower ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The method covers the determination of ambient air concentrations of sulphur dioxide in zones classified as rural areas, urban-background areas and traffic-orientated locations.
The results are expressed in mg/m3 (at 293 K and 101,3 kPa).
When the standard is used for other purposes than the EU-directive, the range and uncertainty requirements need not apply.
- Standard103 pagesEnglish languagesale 10% offe-Library read for1 day
This document specifies a continuous measurement method for the determination of the concentration of nitrogen dioxide and nitrogen monoxide present in ambient air based on the chemiluminescence measuring principle. This document describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate chemiluminescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the Directives data quality requirements and requirements during sampling, calibration and quality assurance.
The method is applicable to the determination of the concentration of nitrogen dioxide present in ambient air from 0 mg/m3 to 500 mg/m3. This concentration range represents the certification range for NO2 for the type approval test.
NOTE 1 0 mg/m3 to 500 mg/m3 of NO2 corresponds to 0 nmol/mol to 261 nmol/mol of NO2.
The method is applicable to the determination of the concentration of nitrogen monoxide present in ambient air from 0 mg/m3 to 1 200 mg/m3. This concentration range represents the certification range for NO for the type approval test.
NOTE 2 0 mg/m3 to 1 200 mg/m3 of NO corresponds to 0 nmol/mol to 962 nmol/mol of NO.
The method covers the determination of ambient air concentrations of nitrogen dioxide and nitrogen monoxide in zones classified as rural areas, urban-background areas and traffic-orientated locations.
NOTE 3 Lower ranges may be used for measurement systems applied at rural locations monitoring Ecosystems.
The results are expressed in mg/m3 (at 293 K and 101,3 kPa).
When the standard is used for other purposes than the EU Directive, the range and uncertainty requirements need not apply.
- Standard92 pagesEnglish languagesale 10% offe-Library read for1 day