ISO/TC 138/SC 2/WG 1 - Plastics piping systems for hot and cold water applications
Systèmes de canalisations en plastiques pour les applications destinées à l'eau chaude et froide
General Information
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Draft2 pagesEnglish languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Draft1 pageEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Draft2 pagesEnglish languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Draft2 pagesEnglish languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Draft4 pagesEnglish languagesale 15% off
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
- Draft3 pagesEnglish languagesale 15% off
- Standard4 pagesEnglish languagesale 15% off
- Standard4 pagesFrench languagesale 15% off
- Draft4 pagesEnglish languagesale 15% off
This document gives requirements and guidance for the assessment of conformity of compounds, products, and assemblies in accordance with the applicable part(s) of ISO 15874 intended to be included in the manufacturer's quality plan as part of the quality management system and for the establishment of certification procedures. NOTE In order to help the reader, a basic test matrix is given in Annex A. In conjunction with the other parts of ISO 15874 (see Foreword), this document is applicable to polypropylene (PP) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15874-1:2013, Table 1).
- Technical specification17 pagesEnglish languagesale 15% off
This document gives requirements and guidance for the assessment of conformity of compounds, products, and assemblies in accordance with the applicable part(s) of ISO 15875 intended to be included in the manufacturer's quality plan as part of the quality management system and for the establishment of certification procedures. NOTE In order to help the reader, a basic test matrix is given in Annex A. In conjunction with the other parts of ISO 15875 (see Foreword), this document is applicable to crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15875-1:2003, Table 1).
- Technical specification18 pagesEnglish languagesale 15% off
This document gives requirements and guidance for the assessment of conformity of compounds, products, and assemblies in accordance with the applicable part(s) of ISO 15876 intended to be included in the manufacturer's quality plan as part of the quality management system and for the establishment of certification procedures. NOTE In order to help the reader, a basic test matrix is given in Annex A. In conjunction with the other parts of ISO 15876 (see Foreword), this document is applicable to polybutene (PB) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15876-1:2017, Table 1).
- Technical specification16 pagesEnglish languagesale 15% off
This document gives requirements and guidance for the assessment of conformity of materials, products, and assemblies in accordance with the applicable part(s) of ISO 15877 intended to be included in the manufacturer's quality plan as part of the quality management system and for the establishment of certification procedures. NOTE In order to help the reader, a basic test matrix is given in Annex A. In conjunction with the other parts of ISO 15877 (see Foreword), this document is applicable to Chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15877-1:2009, Table 1).
- Technical specification16 pagesEnglish languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard3 pagesEnglish languagesale 15% off
- Standard3 pagesFrench languagesale 15% off
ISO 15876-1:2017 specifies the general aspects of polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application (see Table 1). The designation polybutene is used together with the abbreviation PB throughout this document. ISO 15876-1:2017 covers a range of service conditions (application classes) and design pressure and pipe dimension classes. Values of TD, Tmax and Tmal in excess of those in Table 1 do not apply. NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of ISO 15876, this document is applicable to PB pipes, fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard9 pagesEnglish languagesale 15% off
- Standard10 pagesFrench languagesale 15% off
ISO 15876-2:2017 specifies the characteristics of pipes for polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15876‑1). The designation polybutene is used together with the abbreviation PB throughout this document. ISO 15876-2:2017 covers a range of service conditions (application classes), design pressures and pipe dimension classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876‑1, this document does not apply. NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of ISO 15876, this document is applicable to PB pipes, their joints and to joints with components of PB, other plastics and non-plastics materials intended to be used for hot and cold water installations. It is applicable to pipes with or without (a) barrier layer(s). NOTE 2 In the case of plastics pipes provided with a thin barrier layer, e.g. to prevent or greatly diminish the diffusion of gases and the transmission of light into or through the pipe wall, the design stress requirements are totally met by the base polymer (PB).
- Standard16 pagesEnglish languagesale 15% off
- Standard16 pagesFrench languagesale 15% off
ISO 15876-5:2017 specifies the characteristics of the fitness for purpose of polybutene-1 (PB-1) piping systems, intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption, (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application (see ISO 15876‑1). The designation polybutene is used together with the abbreviation PB throughout this document. ISO 15876-5:2017 covers a range of service conditions (application classes) and design pressure classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876‑1:2016, Table 1, this document does not apply. NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of ISO 15876, it is applicable to PB pipes, fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard8 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
ISO 15876-3:2017 specifies the characteristics of fittings for polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application (see ISO 15876‑1). The designation polybutene is used together with the abbreviation PB throughout this document. ISO 15876-3:2017 covers a range of service conditions (application classes) and design pressure classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876‑1:2016, Table 1, this document does not apply. NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes. It also specifies the parameters for the test methods referred to in this document. In conjunction with the other parts of ISO 15876, this document is applicable to fittings made from PB and to fittings made from other materials which are intended to be fitted to pipes conforming to ISO 15876‑2 for hot and cold water installations, whereby the joints conform to the requirements of ISO 15876‑5. ISO 15876-3:2017 is applicable to fittings of the following types: - socket fusion fittings; - electrofusion fittings; - mechanical fittings; - fittings with incorporated inserts. It is also applicable to fittings made from alternative materials which, when fitted to pipes conforming to ISO 15876‑2, conform to the requirements of ISO 15876‑5.
- Standard14 pagesEnglish languagesale 15% off
- Standard14 pagesFrench languagesale 15% off
ISO 15874-5:2013 specifies the characteristics of the fitness for purpose of polypropylene (PP) piping systems, intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application. It covers a range of service conditions (classes of application) and design pressure classes. It also specifies test parameters for test methods. In conjunction with the other parts of ISO 15874, it is applicable to PP pipes, fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard10 pagesEnglish languagesale 15% off
- Standard10 pagesEnglish languagesale 15% off
- Standard10 pagesFrench languagesale 15% off
ISO 15874-1:2013 specifies the general aspects of polypropylene (PP) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures according to the class of application. It covers a range of service conditions (classes of application), design pressures and pipe dimension classes. It also specifies test parameters for test methods. In conjunction with the other parts of ISO 15874, ISO 15874-1:2013 is applicable to PP pipes, fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
ISO 15874-2:2013 specifies the requirements of pipes made from polypropylene (PP) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not intended for human consumption (domestic systems) and for heating systems under operating pressures and temperatures appropriate to the class of application. It covers a range of service conditions (application classes), design pressures and pipe dimension classes. It also specifies test parameters for test methods. In conjunction with the other parts of ISO 15874, ISO 15874-2:2013 is applicable to PP pipes, their joints and to joints with components of PP, other plastics and non-plastics materials intended to be used for hot and cold water installations. It is applicable to pipes with or without (a) barrier layer(s).
- Standard18 pagesEnglish languagesale 15% off
- Standard18 pagesFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
- Standard2 pagesEnglish languagesale 15% off
- Standard2 pagesFrench languagesale 15% off
ISO 15877-5:2009 specifies the characteristics of the fitness for purpose of chlorinated poly(vinyl chloride) (PVC-C) piping systems, intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption, (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application. ISO 15877-5:2009 covers a range of service conditions (application classes) and design pressure classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15877-1:2009. ISO 15877-5:2009 specifies the test parameters for the test methods to which it refers. In conjunction with the other parts of ISO 15877, it is applicable to PVC-C pipes and fittings, their joints and joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
ISO 15877-1:2009 specifies the general requirements of chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (classes of application), design pressures and pipe dimension classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given. ISO 15877-1:2009 also specifies the test parameters for the test methods to which it refers. In conjunction with the other parts of ISO 15877, it is applicable to PVC-C pipes and fittings, their joints and joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard12 pagesEnglish languagesale 15% off
- Standard12 pagesFrench languagesale 15% off
ISO 15877-2:2009 specifies the requirements of pipes made from chlorinated poly(vinyl chloride) (PVC-C) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application. ISO 15877-2:2009 covers a range of service conditions (application classes), design pressures and pipe series. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15877-1:2009. ISO 15877-2:2009 also specifies the test parameters for the test methods to which it refers. In conjunction with the other parts of ISO 15877, it is applicable to PVC-C pipes, their joints and joints with components of PVC-C, other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard15 pagesEnglish languagesale 15% off
- Standard16 pagesFrench languagesale 15% off
ISO 15877-3:2009 specifies the characteristics of fittings made from chlorinated poly(vinyl chloride) (PVC-C) for piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application. ISO 15877-3:2009 covers a range of service conditions (application classes) and design pressure classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15877-1:2009. ISO 15877-3:2009 also specifies the parameters for the test methods to which it refers. In conjunction with the other parts of ISO 15877, it is applicable to PVC-C fittings, their joints and joints with components of PVC-C, other plastics and non-plastics materials intended to be used for hot and cold water installations. It is applicable to fittings of the following types: fittings for solvent cement joints; mechanical fittings; fittings with incorporated inserts.
- Standard25 pagesEnglish languagesale 15% off
- Standard25 pagesFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Draft8 pagesEnglish languagesale 15% off
- Draft8 pagesEnglish languagesale 15% off
- Draft16 pagesEnglish languagesale 15% off
- Draft8 pagesEnglish languagesale 15% off
ISO 10508:2006 gives guidance for the classification and design of hot and cold water pressure systems which use plastics pipes and plastics or metal fittings. It establishes a classification system for common service conditions for pressurized hot and cold water systems. It gives a basis for evaluation and design of thermoplastics pipes and fittings in relation to the system performance requirements. It applies to plastics piping systems used to carry water in distribution systems of hot and cold water, including potable water, and in transportation systems of hot water for heating, under design pressures up to at least 10 bar at 20 degrees Celsius and up to 10 bar at temperatures according to the class of application.
- Standard9 pagesEnglish languagesale 15% off
- Standard9 pagesFrench languagesale 15% off
ISO 15875-1:2003 specifies the general aspects of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) or for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (classes of application), design pressures and pipe dimension classes. It also specifies the test parameters for the test methods referred to in the standard. In conjunction with the other parts of ISO 15875, it is applicable to PE-X pipes, fittings and their joints, including joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
ISO 15875-3:2003 specifies the characteristics of fittings for crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) or for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (application classes) and design pressure classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15875-1. It also specifies the parameters for the test methods referred to in this standard. In conjunction with the other parts of ISO 15875, it is applicable to fittings made from PE-X and to fittings, made from other materials, intended to be fitted to pipes conforming to ISO 15875-2 to give joints conforming to the requirements of ISO 15875-5. It is applicable to fittings of the following types: mechanical fittings electrofusion fittings fittings with incorporated inserts.
- Standard11 pagesEnglish languagesale 15% off
- Standard11 pagesFrench languagesale 15% off
ISO 15875-5:2003 specifies the characteristics of the fitness for purpose of crosslinked polyethylene (PE-X) piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (classes of application) and design pressure classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15875-1. It also specifies the test parameters for the test methods referred to in the standard. In conjunction with the other parts of ISO 15875, it is applicable to PE-X pipes, fittings and their joints, including joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard7 pagesEnglish languagesale 15% off
- Standard7 pagesFrench languagesale 15% off
ISO 15875-2:2003 specifies the characteristics of pipes made from crosslinked polyethylene (PE-X) for piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) or for heating systems, under operating pressures and temperatures appropriate to the class of application. It covers a range of service conditions (application classes), design pressures and pipe dimension classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15875-1. It also specifies the test parameters for the test methods referred to in the standard. In conjunction with the other parts of ISO 15875, it is applicable to PE-X pipes and their joints, including joints with other PE-X components and components made of other plastics and non-plastics materials intended to be used for hot and cold water installations. It is applicable to pipes with or without (a) barrier layer(s).
- Standard12 pagesEnglish languagesale 15% off
- Standard13 pagesFrench languagesale 15% off
ISO 15877-7:2009 gives guidance for the assessment of conformity included in the manufacturer's quality plan as part of his/her quality system. ISO 15877-7:2009 includes: - provisions for materials, components, joints and assemblies given in the applicable part(s) of ISO 15877; - provisions for the manufacturer's quality system, which can conform to ISO 9001; - definitions and procedures applied if certification is involved; in which case, the certification body can be accredited to ISO/IEC Guide 65 or ISO/IEC Guide 62, as applicable. In conjunction with the other parts of ISO 15877, ISO 15877-7:2009 is applicable to chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems), under design pressures and temperatures appropriate to the class of application (see Table 1 of ISO 15877-1:2009).
- Technical specification13 pagesEnglish languagesale 15% off
- Technical specification15 pagesFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
- Standard1 pageEnglish languagesale 15% off
- Standard1 pageFrench languagesale 15% off
ISO 15877-5:2003 specifies the characteristics of the fitness for purpose of chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (classes of application) and design pressure classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15877-1. It also specifies the test parameters for the test methods referred to in the standard. In conjunction with the other parts of ISO 15877, it is applicable to PVC-C pipes, fittings and their joints, including joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard8 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
ISO 15877-3:2003 specifies the characteristics of fittings for chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) or for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (application classes) and design pressure classes. It does not apply if the values of the design temperature, maximum design temperature and malfunction temperature are in excess of those given in ISO 15877-1. It also specifies the parameters for the test methods referred to in this standard. In conjunction with the other parts of ISO 15877, it is applicable to fittings made from PVC-C and to fittings, made from other materials, intended to be fitted to pipes conforming to ISO 15877-2 to give joints conforming to the requirements of ISO 15877-5. It is also applicable to fittings made from alternative materials which, when fitted to pipes conforming to ISO 15877-2, give joints conforming to the requirements of ISO 15877-5. It is applicable to fittings of the following types: fittings for solvent cement joints mechanical fittings fittings with incorporated inserts.
- Standard23 pagesEnglish languagesale 15% off
- Standard25 pagesFrench languagesale 15% off
ISO 15877-1:2003 specifies the general aspects of chlorinated poly(vinyl chloride) (PVC-C) piping systems intended to be used for hot and cold water installations, within buildings, for the conveyance of water which may or may not be intended for human consumption (domestic systems) or for heating systems, under design pressures and temperatures appropriate to the class of application. It covers a range of service conditions (classes of application), design pressures and pipe dimension classes. It also specifies the test parameters for the test methods referred to in the standard. In conjunction with the other parts of ISO 15877, it is applicable to PVC-C pipes, fittings and their joints, including joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
- Standard10 pagesEnglish languagesale 15% off
- Standard12 pagesFrench languagesale 15% off