11.120.01 - Pharmaceutics in general
Pharmaceutics in general
Pharmazie im allgemeinen
Pharmacie en general
Farmacija na splošno
General Information
This European Standard specifies performance requirements and methods of test for non-reclosable packaging that have been designated child-resistant. This standard is intended for type approval only (see 3.5) and is not intended for quality assurance purposes.
- Standard17 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of ISO 22442 applies to medical devices other than in vitro diagnostic medical devices
manufactured utilizing materials of animal origin, which are non-viable or have been rendered nonviable.
It specifies, in conjunction with ISO 14971, a procedure to identify the hazards and hazardous
situations associated with such devices, to estimate and evaluate the resulting risks, to control these
risks, and to monitor the effectiveness of that control. Furthermore, it outlines the decision ...view more
- Standard38 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of ISO 22442 specifies requirements for controls on the sourcing, collection, and handling
(which includes storage and transport) of animals and tissues for the manufacture of medical devices
utilizing materials of animal origin other than in vitro diagnostic medical devices. It applies where
required by the risk management process as described in ISO 22442‑1.
NOTE 1 Selective sourcing is considered to be especially important for transmissible spongiform
encephalopathy (TSE) risk ...view more
- Standard26 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements for information to be supplied by a manufacturer for medical devices regulated by Council Directive 90/385/EEC relating to active implantable medical devices and Council Directive 93/42/EEC concerning medical devices. It does not specify the language to be used for such information, nor does it specify the means by which the information is to be supplied. It is also intended to complement the specific requirements of the cited EU Directives on medica...view more
- Standard26 pagesEnglish language
sale 10% off- e-Library read for1 day
This European Standard specifies requirements for the labelling of a medical device or parts of a medical device to indicate the presence of phthalates, when required by Annex I of Directive 93/42/EEC Section 7.5, 2nd paragraph. This specifically includes the format of a symbol to be used in the labelling. This European Standard does not specify the requirements for information to be supplied with medical devices, which are addressed by EN 980 and EN 1041.
This European Standard does not specif...view more
- Standard12 pagesEnglish language
sale 10% off- e-Library read for1 day
This part of ISO 22442 specifies requirements for the validation of the elimination and/or inactivation of viruses and TSE agents during the manufacture of medical devices (excluding in vitro diagnostic medical devices) utilizing animal tissue or products derived from animal tissue, which are non-viable or have been rendered non-viable. It applies where required by the risk management process as described in ISO 22442-1. It does not cover other transmissible and non-transmissible agents.
- Standard31 pagesEnglish language
sale 10% off- e-Library read for1 day
Establishes definitions, requirements, methods of testing and rated values for phase-to-earth capacitive and screen-to-earth intrusive inductive coupling devices to be used in medium voltage DLC systems.
- Standard21 pagesEnglish language
sale 10% off- e-Library read for1 day
This Technical Reports describes quality designations and indications for algae and directly derived products from algae production required for or by pharma producers and industry. It does not apply to Food and Feed sectors.
Note: This TRs does not provide instructions on existing handling of technical requirements in existing legislations.
- Technical report39 pagesEnglish language
sale 10% off- e-Library read for1 day
This document specifies requirements for controls on the sourcing, collection, and handling (which includes storage and transport) of animals and tissues for the manufacture of medical devices utilizing materials of animal origin other than in vitro diagnostic medical devices. It applies where required by the risk management process as described in ISO 22442‑1.
NOTE Selective sourcing is especially important for transmissible spongiform encephalopathy (TSE) risk management, i.e. when utilising ...view more
- Draft22 pagesEnglish language
sale 10% off- e-Library read for1 day
This standard specifies requirements for information to be supplied by a manufacturer for medical devices regulated by Council Directive 90/385/EEC relating to active implantable medical devices and Council Directive 93/42/EEC concerning medical devices. It does not specify the language to be used for such information, nor does it specify the means by which the information is to be supplied. It is also intended to complement the specific requirements of the cited EU Directives on medical devices...view more
- Amendment5 pagesEnglish language
sale 10% off- e-Library read for1 day