This document refers to temperature volume correction factors, which allow users to convert volumes,
measured at ambient conditions, to those at reference conditions for transactional purposes. This
document also refers to compressibility factors required to correct hydrocarbon volumes measured
under pressure to the corresponding volumes at the equilibrium pressure for the measured
temperature.
Table 1 shows the defining limits and their associated units of correction factors referenced in this
document for crude oil, refined products and lubricating oils. These values are shown in bold italics.
Also shown in the table are the limits converted to their equivalent units (and, in the case of the densities,
other base temperatures). Table 2 shows defining limits of correction factors for light hydrocarbons
(natural gas liquids and liquefied petroleum gases).
- Standard15 pagesEnglish languagesale 15% off
- Standard21 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard16 pagesFrench languagesale 15% off
ISO 12917-1:2017 specifies manual methods for the calibration of nominally horizontal cylindrical tanks, installed at fixed locations. The methods in this document are applicable to insulated and non-insulated tanks, either when they are above-ground or underground. The methods are applicable to pressurized tanks and to both knuckle-dish-end and flat-end cylindrical tanks as well as elliptical and spherical head tanks. ISO 12917-1:2017 is applicable to tanks inclined from the horizontal, provided a correction is applied for the measured tilt. Although this document does not impose any limits on the maximum tank diameter and maximum tank tilt to which this document is applicable, the practical limits would be about 4 m in diameter and 10° in tilt.
- Standard46 pagesEnglish languagesale 15% off
- Standard46 pagesFrench languagesale 15% off
This part of ISO 7507 specifies a method for the calibration of vertical cylindrical tanks having diameters greater than 5 m by means of internal measurements using an electro-optical distance-ranging (EODR) instrument, and for the subsequent compilation of tank capacity tables. The method is suitable for tanks tilted up to a 3 % deviation from the vertical, provided that a correction is applied for the measured tilt as described in ISO 7507-1:2003, Clause 11. This part of ISO 7507 also applies to tanks with floating roofs or internal floating blankets.
- Standard20 pagesEnglish languagesale 15% off
- Standard24 pagesEnglish languagesale 10% offe-Library read for1 day
ISO 7507-3:2006 specifies a calibration procedure for application to tanks above 8 m in diameter with cylindrical courses that are substantially vertical. It provides a method for determining the volumetric quantity contained within a tank at gauged liquid levels. The measurements required to determine the radius are made either internally or externally. The external method is applicable only to tanks that are free of insulation.
ISO 7507-3:2006 is suitable for tanks tilted up to a 3 % deviation from the vertical, provided that a correction is applied for the measured tilt as described in ISO 7507-1.
- Standard38 pagesEnglish languagesale 15% off
- Standard43 pagesEnglish languagesale 10% offe-Library read for1 day
This International Standard specifies the requirements for the equipment required to measure manually the liquid level or the corresponding volume of petroleum and petroleum products stored in tanks and containers.
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard26 pagesEnglish languagesale 15% off
- Standard32 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard27 pagesFrench languagesale 15% off
This part of ISO 7507 specifies a method for the calibration of substantially vertical cylindrical tanks by measuring the tank using a strapping tape. This method is known as the strapping method and is suitable for use as a working method, a reference method or a referee method. The operation of strapping, the corrections to be made and the calculations leading to the compilation of the tank capacity table are described. This method does not apply to abnormally deformed, e.g. dented or non-circular, tanks. This method is suitable for tilted tanks with a deviation of up to 3 % from the vertical, provided that a correction for the measured tilt is applied in the calculations.
- Standard67 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard62 pagesEnglish languagesale 15% off
- Standard67 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard64 pagesFrench languagesale 15% off
This part of ISO 7507 specifies a method for the calibration of tanks above eight metres in diameter with cylindrical courses that are substantially vertical. It provides a method for determining the volumetric quantity contained within a tank at gauged liquid levels. The method specified in this part of ISO 7507 is suitable for tilted tanks with up to 3 % deviation from the vertical provided that a correction is applied for the measurement tilt, as described in ISO 7507-1. This method is an alternative to other methods such as strapping (ISO 7507-1) and the optical-triangulation method (ISO 7507-3).
- Standard26 pagesEnglish languagesale 15% off
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard26 pagesFrench languagesale 15% off
Specifies a method for the calibration of tanks by addition of batches of liquid. The liquid is used as a volume-transfer medium, measured accurately by means of a meter. This International Standard is not applicable to the calibration of reference measuring instruments, proving tanks, or meter provers. NOTE Applicable standards are given in the bibliography.
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard26 pagesEnglish languagesale 15% off
- Standard31 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard26 pagesFrench languagesale 15% off
Specifies a method for the calibration of non-insulated vertical cylindrical tanks having diameters greater than 5 m by means of external measurement using an electro-optical distance-ranging method (EODR), and for the subsequent compilation of tank capacity tables. This part is applicable to tanks with cone-up or cone-down bottoms as well as to tanks with flat bottoms.
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard11 pagesEnglish languagesale 15% off
- Standard16 pagesEnglish languagesale 10% offe-Library read for1 day
- Standard11 pagesFrench languagesale 15% off
ISO 12917-2:2002 specifies a method for the calibration of horizontal cylindrical tanks having diameters greater than 2 m by means of internal measurements using an electro-optical distance-ranging instrument, and for the subsequent compilation of tank-capacity tables. This method is known as the internal electro-optical distance-ranging (EODR) method. ISO 12917-2:2002 is applicable to tanks inclined by up to 10 % from the horizontal, provided a correction is applied for the measured tilt.
- Standard14 pagesEnglish languagesale 15% off
- Standard15 pagesFrench languagesale 15% off
Migrated from Progress Sheet (TC Comment) (2000-07-10): Decision of BT to submit this ISO document to UAP procedure.
- Standard27 pagesEnglish languagesale 10% offe-Library read for1 day