IEC/SC 62A - Common aspects of electrical equipment used in medical practice
To prepare international standards concerning the common aspects of the manufacture, installation and application of electrical equipment used in medical practice, including systems, equipment, accessories, related terminology, concepts, terms, definitions and symbols.
Aspects généraux des équipements électriques utilisés en pratique médicale
Préparer des normes internationales traitant des aspects généraux de la fabrication, de l'installation et de l'emploi d'appareils électriques utilisés dans la pratique médicale comprenant les systèmes, appareils et accessoires, ainsi que de la terminologie, des concepts, des définitions et symboles s'y rapportant.
General Information
This document specifies general requirements for ORGANIZATIONS in the application of RISK MANAGEMENT before, during and after the connection of a HEALTH IT SYSTEM within a HEALTH IT INFRASTRUCTURE, by addressing the KEY PROPERTIES of SAFETY, EFFECTIVENESS and SECURITY whilst engaging appropriate stakeholders. IEC 80001-1:2021 cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) structure changed to better align with ISO 31000; b) establishment of requirements for an ORGANIZATION in the application of RISK MANAGEMENT; c) communication of the value, intention and purpose of RISK MANAGEMENT through principles that support preservation of the KEY PROPERTIES during the implementation and use of connected HEALTH SOFTWARE and/or HEALTH IT SYSTEMS.
- Draft31 pagesEnglish languagesale 15% off
This document provides quality requirements for health apps and defines a health app quality label in order to visualize the quality and reliability of health apps. This document is applicable to health apps, which are a special form of health software. It covers the entire life cycle of health apps. This document is intended for use by app manufacturers as well as app assessment organizations in order to communicate the quality and reliability of a health app. Consumers, patients, carers, health care professionals and their organizations, health authorities, health insurers and the wider public can use the health app quality label and report when recommending or selecting a health app for use, or for adoption in care guidelines, care pathways and care contracts. NOTE 1 Health apps can be subject to national legislation, such as for medical devices. NOTE 2 See Annex C for additional details on the scope. Outside the scope of this document are guidelines to comply to the medical device regulation.
- Technical specification78 pagesEnglish languagesale 15% off
This document specifies terminology, principles and a process for risk management of medical devices, including software as a medical device and in vitro diagnostic medical devices. The process described in this document intends to assist manufacturers of medical devices to identify the hazards associated with the medical device, to estimate and evaluate the associated risks, to control these risks, and to monitor the effectiveness of the controls. The requirements of this document are applicable to all phases of the life cycle of a medical device. The process described in this document applies to risks associated with a medical device, such as risks related to biocompatibility, data and systems security, electricity, moving parts, radiation, and usability. The process described in this document can also be applied to products that are not necessarily medical devices in some jurisdictions and can also be used by others involved in the medical device life cycle. This document does not apply to: — decisions on the use of a medical device in the context of any particular clinical procedure; or — business risk management. This document requires manufacturers to establish objective criteria for risk acceptability but does not specify acceptable risk levels. Risk management can be an integral part of a quality management system. However, this document does not require the manufacturer to have a quality management system in place. NOTE Guidance on the application of this document can be found in ISO/TR 24971[9].
- Standard36 pagesEnglish languagesale 15% off
- Standard36 pagesEnglish languagesale 15% off
- Standard39 pagesFrench languagesale 15% off
- Standard39 pagesFrench languagesale 15% off
- Standard39 pagesFrench languagesale 15% off
- Standard37 pagesSpanish languagesale 15% off
- Standard39 pagesSpanish languagesale 15% off
This document focuses on remote maintenance services (RMS) for information systems in healthcare facilities (HCFs) as provided by vendors of medical devices and health information systems. This document specifies the risk assessment necessary to protect remote maintenance activities, taking into consideration the special characteristics of the healthcare field such as patient safety, regulations and privacy protections. This document provides practical examples of risk analysis to protect both the HCF and RMS provider information assets in a safe and efficient (i.e. economical) manner. These assets are primarily the information system itself and personal health data held in the information system.
- Technical specification16 pagesEnglish languagesale 15% off
IEC TR 62366-2:2016(E), which is a Technical Report, contains background information and provides guidance that addresses specific areas that experience suggests can be helpful for those implementing a USABILITY ENGINEERING (HUMAN FACTORS ENGINEERING) PROCESS both as defined in IEC 62366-1:2015 and as supporting goals other than SAFETY. This technical report is not intended to be used for regulatory purposes. It contains no requirements and only provides guidance and tutorial information.
- Technical report94 pagesEnglish languagesale 15% off
- Standard7 pagesEnglish languagesale 15% off
- Standard8 pagesFrench languagesale 15% off
- Standard32 pagesEnglish languagesale 15% off
- Standard36 pagesFrench languagesale 15% off