SIST EN 60357:2004
(Main)Tungsten halogen lamps (non-vehicle) - Performance specifications
Tungsten halogen lamps (non-vehicle) - Performance specifications
This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: · Projection (including cinematograph and still projection) · · Photographic (including studio) · · Floodlighting · · Special purpose · · General purpose · · Stage lighting This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000
Halogen-Glühlampen (Fahrzeuglampen ausgenommen) - Anforderungen an die Arbeitsweise
Lampes tungstène-halogène (véhicules exceptés) - Prescriptions de performances
La présente Norme Internationale fournit les prescriptions de performances relatives aux lampes tungstène-halogène à culot unique et à celles à deux culots, ayant des tensions assignées jusqu'à 250 V, utilisées pour les applications suivantes : · Projection (y compris cinéma et projection statique) · · Photographie (y compris prises de vues) · · Illumination · · Usage spécial · · Usage général · · Éclairage de scène La présente troisième édition annule et remplace la seconde édition publiée en 1982 et les amendements 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) et 13(2000).
Tungsten halogen lamps (non-vehicle) - Performance specifications (IEC 60357:2002, modified)
Ta mednarodni standard določa zahteve glede zmogljivosti volframovih halogenskih sijalk z enim ali dvema vznožkoma, ki imajo nazivne napetosti do 250 V in se uporabljajo za: · projekcijo (vključno s kinematografsko projekcijo in projekcijo slik), · · fotografijo (vključno s studiem), · · reflektorsko osvetlitev, · · posebne namene, · · splošne namene, · · odrsko razsvetljavo.
General Information
Relations
Standards Content (Sample)
SIST EN 60357:2004SLOVENSKIjanuar 2004
STANDARD(istoveten EN 60357:2003)Tungsten halogen lamps (non-vehicle) - Performance specifications (IEC 60357:2002, modified)©
Standard je založil in izdal Slovenski inštitut za standardizacijo. Razmnoževanje ali kopiranje celote ali delov tega dokumenta ni dovoljenoReferenčna številkaSIST EN 60357:2004(en,fr)ICS29.140.20
EUROPEAN STANDARD
EN 60357 NORME EUROPÉENNE EUROPÄISCHE NORM
January 2003 CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 60357:2003 E
ICS 29.140.20 Supersedes EN 60357:1988 + A4:1991 + A5:1993 + A6:1994 + A7:1994 + A8:1995 + A9:1996+ A10:1997 + A11:1997 + A12:1999 + A13:2000
English version
Tungsten halogen lamps (non-vehicle) -
Performance specifications (IEC 60357:2002)
Lampes tungstène-halogène
(véhicules exceptés) -
Prescriptions de performances (CEI 60357:2002)
Halogen-Glühlampen
(Fahrzeuglampen ausgenommen) - Anforderungen an die Arbeitsweise (IEC 60357:2002)
This European Standard was approved by CENELEC on 2002-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
EN 60357:2003 - 2 - Foreword
The text of document 34A/1001/FDIS, future edition 3 of IEC 60375, prepared by SC 34A, Lamps, of IEC TC 34, Lamps and related equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60357 on 2002-12-01.
This European Standard Supersedes EN 60357:1988 + A4:1991 + A5:1993 + A6:1994 + A7:1994 + A8:1995 + A9:1996 + A10:1997 + A11:1997 + A12:1999 + A13:2000.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2003-09-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2005-12-01
Annexes designated "normative" are part of the body of the standard.
Annexes designated "informative" are given for information only.
In this standard, annexes A, B and ZA are normative and annexes C, D and E are informative. Annex ZA has been added by CENELEC. __________
Endorsement notice
The text of the International Standard IEC 60357:2002 was approved by CENELEC as a European Standard without any modification.
In the official version, for Bibliography, the following notes have to be added for the standards indicated:
IEC 60127-2 NOTE Harmonized as EN 60127-2:1991 (not modified).
IEC 60269-3-1 NOTE Harmonized as HD 630.3.1 S3:2002 (modified).
IEC 60335-2-56 NOTE Harmonized as EN 60335-2-56:1997 (not modified).
IEC 60598-2 NOTE Harmonized as 60598-2-x series (partly modified).
IEC 60630 NOTE Harmonized as EN 60630:1998 (modified).
IEC 60682 NOTE Harmonized as EN 60682:1993 (not modified). __________
- 3 - EN 60357:2003
Annex ZA
(normative)
Normative references to international publications
with their corresponding European publications This European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies (including amendments). NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Publication Year Title EN/HD Year IEC 60050-845 1987 International Electrotechnical Vocabulary (IEV) Chapter 845: Lighting
- - IEC 60061-1 (mod) - 1) Lamp caps and holders together with gauges for the control of interchangeability and safety Part 1: Lamp caps
EN 60061-1 1993 2) IEC 60432-2 (mod) - 1) Incandescent lamps - Safety specifications Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes
EN 60432-2 2000 2) IEC 60432-3 - 3) Part 3: Tungsten halogen lamps (non-vehicle)
- - IEC 61341 - 1) Method of measurement of centre beam intensity and beam angle(s) of reflector lamps
- - CIE 84 1989 The measurement of luminous flux
- -
1) Undated reference. 2) Valid edition at date of issue. 3) To be published.
NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD60357Troisième édition Third edition2002-11Lampes tungstène-halogène (véhicules exceptés) – Prescriptions de performances Tungsten halogen lamps (non-vehicle) –Performance specificationsPour prix, voir catalogue en vigueur For price, see current catalogue” IEC 2002
Droits de reproduction réservés
Copyright - all rights reservedAucune partie de cette publication ne peut être reproduite ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie et les microfilms, sans l'accord écrit de l'éditeur. No part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission,
3, rue de Varembé, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmail@iec.ch
Web: www.iec.ch CODE PRIX PRICE CODE XDCommission Electrotechnique InternationaleInternational Electrotechnical Commission
– 2 –60357 © CEI: 2002SOMMAIRE1Généralités.81.1Domaine d’application.81.2Références normatives.81.3Définitions.101.4Prescriptions.141.4.1Généralités.141.4.2Culots et socles.141.4.3Dimensions.141.4.4Puissance.141.4.5Caractéristiques photométriques.141.4.6Maintien du flux lumineux et maintien de l’intensité dans l’axe du faisceau161.4.7Notices d’avertissement pour lampes sans enveloppe extérieure.161.5Renseignements pour la conception des luminaires.161.6Feuilles d’informations générales et feuilles de caractéristiques de lampes.161.6.1Système de numérotage.161.6.2Feuilles d’informations générales.181.6.3Feuilles de caractéristiques de lampes.182Lampesdeprojection3Lampesde photographie (ycomprisprises devue)4Lampesd’illumination5Lampesd’usagespécial6Lampesd’usagegénéral7Lampesd’éclairagedescèneAnnexe A (normative)
Méthode de contrôle des caractéristiques photométriques, de leurmaintien, et de la durée de vie.A-1Annexe B (normative)
Symboles.B-1Annexe C (informative)
Renseignements pour la conception des luminaires.C-1Annexe D (informative)
Mesurage de la température de paroi d’ampoule.D-1Annexe E (informative)
Codes ILCOS.E-1Bibliographie
60357 © IEC:2002– 3 –CONTENTS1General.91.1Scope.91.2Normative references.91.3Definitions.111.4Lamp requirements.141.4.1General.141.4.2Caps and bases.141.4.3Dimensions.141.4.4Wattage.141.4.5Photometric characteristics.141.4.6Lumen maintenance and centre beam intensity maintenance.171.4.7Cautionary notices for lamps without outer envelope.171.5Information for luminaire design.171.6General data sheets and lamp data sheets.171.6.1Numbering system.171.6.2General data sheets.181.6.3Lamp data sheets.182Projection lamps3Photographiclamps(includingstudio)4Floodlight lamps5Special purpose lamps6General purposelamps7Stage lighting lampsAnnex A (normative)
Method of test for photometric, maintenance and lifecharacteristics.A-2Annex B (normative)
Symbols.B-2Annex C (informative)
Information for luminaire design.C-2Annex D (informative)
Bulb wall temperature measurement.D-2Annex E (informative)
ILCOS codes.E-2Bibliography
– 4 – 60357 © CEI: 2002 COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE ____________ LAMPES TUNGSTÈNE-HALOGÈNE (véhicules exceptés) – PRESCRIPTIONS DE PERFORMANCES AVANT-PROPOS1) La CEI (Commission Électrotechnique Internationale) est une organisation mondiale de normalisation composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de la CEI). La CEI a pour objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines de l'électricité et de l'électronique. A cet effet, la CEI, entre autres activités, publie des Normes internationales. Leur élaboration est confiée à des comités d'études, aux travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations internationales, gouvernementales et non gouvernementales, en liaison avec la CEI, participent également aux travaux. La CEI collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des conditions fixées par accord entre les deux organisations. 2) Les décisions ou accords officiels de la CEI concernant les questions techniques représentent, dans la mesure du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux intéressés sont représentés dans chaque comité d’études. 3) Les documents produits se présentent sous la forme de recommandations internationales. Ils sont publiés comme normes, spécifications techniques, rapports techniques ou guides et agréés comme tels par les Comités nationaux. 4) Dans le but d'encourager l'unification internationale, les Comités nationaux de la CEI s'engagent à appliquer de façon transparente, dans toute la mesure possible, les Normes internationales de la CEI dans leurs normes nationales et régionales. Toute divergence entre la norme de la CEI et la norme nationale ou régionale correspondante doit être indiquée en termes clairs dans cette dernière. 5) La CEI n’a fixé aucune procédure concernant le marquage comme indication d’approbation et sa responsabilité n’est pas engagée quand un matériel est déclaré conforme à l’une de ses normes. 6)
L’attention est attirée sur le fait que certains des éléments de la présente Norme internationale peuvent faire l’objet de droits de propriété intellectuelle ou de droits analogues. La CEI ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits de propriété et de ne pas avoir signalé leur existence. La Norme internationale CEI 60357 a été établie par le sous-comité 34A : Lampes, du comité d'études 34 de la CEI : Lampes et équipements associés. La présente troisième édition annule et remplace la seconde édition publiée en 1982 et les amendements 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) et 13(2000). La présente troisième édition constitue une révision technique. Le texte de cette norme est issu des documents suivants: FDIS Rapport de vote 34A/1001/FDIS 34A/1010/RVD Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant abouti à l'approbation de cette norme. Cette publication a été rédigée selon les Directives ISO/CEI, Partie 2.
60357 © IEC:2002 – 5 – INTERNATIONAL ELECTROTECHNICAL COMMISSION____________ TUNGSTEN HALOGEN LAMPS (non-vehicle) – PERFORMANCE SPECIFICATIONS FOREWORD1) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of the IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, the IEC publishes International Standards. Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. The IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of the IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested National Committees. 3) The documents produced have the form of recommendations for international use and are published in the form of standards, technical specifications, technical reports or guides and they are accepted by the National Committees in that sense. 4)
In order to promote international unification, IEC National Committees undertake to apply IEC International Standards transparently to the maximum extent possible in their national and regional standards. Any divergence between the IEC Standard and the corresponding national or regional standard shall be clearly indicated in the latter. 5)The IEC provides no markingprocedure toindicateits approval andcannot be renderedresponsible for any equipment declared to be in conformity with one of its standards. 6)Attentionis drawn to the possibilitythat some of theelementsofthis International Standard maybe thesubjectof patent rights. The IEC shall not be held responsible for identifying any or all such patent rights. International Standard IEC60357 has been prepared by subcommittee 34A: Lamps, of IEC technical committee 34: Lamps and related equipment. This third edition cancels and replaces the second edition published in 1982 and amendments 1(1984), 2(1985), 3(1987), 4(1989), 5(1992), 6(1993), 7(1994), 8(1995), 9(1996), 10(1996), 11(1997), 12(1999) and 13(2000). This third edition constitutes a technical revision. The text of this standard is based on the following documents: FDIS Report on voting 34A/1001/FDIS 34A/1010/RVD Full information on the voting for the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.
– 6 –60357 © CEI: 2002Le comité a décidé que le contenu de cette publication ne sera pas modifié avant 2004. Acette date, la publication sera•reconduite;•supprimée;•remplacée par une édition révisée, ou•amendée.
60357 © IEC:2002– 7 –The committee has decided that the contents of this publication will remain unchanged until2004. At this date, the publication will be•reconfirmed;•withdrawn;•replaced by a revised edition, or•amended.
– 8 – 60357 © CEI: 2002 LAMPES TUNGSTÈNE-HALOGÈNE (véhicules exceptés) – PRESCRIPTIONS DE PERFORMANCES 1 Généralités 1.1 Domaine d’application La présente Norme Internationale fournit les prescriptions de performances relatives aux lampes tungstène-halogène à culot unique et à celles à deux culots, ayant des tensions assignées jusqu’à 250 V, utilisées pour les applications suivantes : xProjection (y compris cinéma et projection statique) xPhotographie (y compris prises de vues) xIllumination xUsage spécial xUsage général xÉclairage de scène Pour certaines des exigences de la présente norme, le texte renvoie à « la feuille de caractéristiques de lampe correspondante ». Pour certaines lampes, ces feuilles de caractéristiques sont incluses dans la présente norme. Pour d’autres, faisant partie de son domaine d’application, les données correspondantes sont fournies par le fabricant ou le vendeur responsable. Les exigences de la présente norme ne concernent que les essais de type. NOTE Les exigences et les tolérances retenues par la présente norme correspondent à l’essai d’un échantillon d’essai de type soumis par le fabricant dans ce but. Il convient, en principe, que cet échantillon d’essai de type soit constitué d’unités ayant des caractéristiques typiques, et aussi proches que possible des valeurs centrales, de la production du fabricant. On peut s’attendre, compte tenu des tolérances données dans la présente norme, à ce que les produits fabriqués conformément à l’échantillon d’essai de type soient conformes à la norme pour la majorité de la production. Cependant, en raison de la dispersion de la production, il est inévitable que des produits se trouvent parfois en dehors des tolérances spécifiées. Des indications concernant les plans d’échantillonnage et les procédures de contrôle par attributs sont données dans la CEI 60410. 1.2 Références normatives Les documents de référence suivants sont indispensables pour l'application du présent document. Pour les références datées, seule l'édition citée s'applique. Pour les références non datées, la dernière édition du document de référence s'applique (y compris les éventuels amendements). CEI 60050-845 : 1987, Vocabulaire électrotechnique international (VEI) – Chapitre 845 : EclairageCEI 60061-1 : Culots de lampes et douilles ainsi que calibres pour le contrôle de l’interchangeabilité et de la sécurité – Partie 1 : Culots de lampes CEI 60432-2: Lampes à incandescence – Prescriptions de sécurité - Partie 2: Lampes tungstène-halogène pour usage domestique et éclairage général similaire CEI 60432-3: Lampes à incandescence – Prescriptions de sécurité - Partie 3: Lampes tungstène-halogène (véhicules exceptés)1)——————— 1)A publier.
60357 © IEC:2002 – 9 – TUNGSTEN HALOGEN LAMPS (non-vehicle) – PERFORMANCE SPECIFICATIONS 1 General 1.1 Scope This International Standard specifies the performance requirements for single-capped and double-capped tungsten halogen lamps, having rated voltages of up to 250 V, used for the following applications: xProjection (including cinematograph and still projection) xPhotographic (including studio) xFloodlighting xSpecial purpose xGeneral purpose xStagelightingFor some of the requirements given in this standard reference is made to "the relevant data sheet". For some lamps these data sheets are contained in this standard. For other lamps, falling under the scope of this standard, the relevant data are supplied by the lamp manufacturer or responsible vendor. The requirements of this standard relate only to type testing. NOTE The requirements and tolerances permitted by this standard correspond to testing of a type test sample, submitted by the manufacturer for that purpose. In principle this type test sample should consist of units having characteristics typical of the manufacturer's production and being as close to the production centre point values as possible.It may be expected with the tolerances given in the standard that products manufactured in accordance with the type test sample will comply with the standard for the majority of production. Due to the production spread however, it is inevitable that there will sometimes be products outside the specified tolerances. For guidance on sampling plans and procedures for inspection by attributes, see IEC 60410. 1.2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 60050-845: 1987, International Electrotechnical Vocabulary (IEV) - Chapter 845: LightingIEC 60061-1: Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps IEC 60432-2: Incandescent lamps – Safety specifications – Part 2: Tungsten halogen lamps for domestic and similar general lighting purposes IEC 60432-3: Incandescent lamps - Safety specifications – Part 3: Tungsten halogen lamps (non-vehicle)1)
1)To be published.
– 10 – 60357 © CEI: 2002 CEI 61341: Méthode de mesure de l’intensité dans l’axe et de l’angle (ou des angles) d’ouverture des lampes à réflecteur CIE 84:1989, The measurement of luminous flux 1.3 Définitions Pour les besoins de la présente Norme internationale, les définitions suivantes s’appliquent, ainsi que d’autres données dans la CEI 60050 (845) : 1.3.1 lampe tungstène-halogène lampe à filament de tungstène à atmosphère gazeuse qui contient une certaine proportion d’halogènes ou de composés halogénés. 1.3.2 lampe tungstène-halogène à culot unique lampe tungstène-halogène ayant un seul culot ou socle 1.3.3lampe tungstène-halogène à deux culots lampe tungstène-halogène ayant un culot ou socle à chaque extrémité de la lampe 1.3.4enveloppe extérieure enceinte transparente ou translucide contenant une source lumineuse tungstène-halogène.
NOTE L’enceinte peut aussi consister en un réflecteur à glace avant intégrée. 1.3.5 valeur assignée valeur d’une grandeur pour une caractéristique de lampe dans des conditions de fonctionnement spécifiées. La valeur et les conditions de fonctionnement sont spécifiées dans la présente norme ou fixées par le fabricant ou le vendeur responsable NOTE Dans la présente norme, un certain nombre de feuilles de caractéristiques indiquent encore, dans le texte français, des valeurs « nominales », traduction périmée de « rated », au lieu de « assignées ». 1.3.6tension assignée tension ou plage de tension spécifiée dans la présente norme ou fixée par le fabricant ou le vendeur responsable NOTE Si les lampes sont marquées d’une plage de tensions, elles conviennent à l’emploi sous toute tension d’alimentation de cette plage. 1.3.7 tension d’essai tension assignée, sauf spécification contraire NOTE Si les lampes sont marquées d’une plage de tensions, la tension d’essai est la moyenne de la plage, sauf spécification contraire. 1.3.8 puissance assignée puissance spécifiée dans la présente norme ou fixée par le fabricant ou le vendeur responsable
60357 © IEC:2002 – 11 – IEC 61341: Method of measurement of centre beam intensity and beam angle(s) of reflector lamps CIE 84:1989, The measurement of luminous flux 1.3 Definitions For the purpose of this International Standard, the following definitions apply, as well as others given in IEC 60050 (845): 1.3.1tungsten halogen lamp gas-filled lamp containing halogens or halogen compounds, the filament being of tungsten 1.3.2single-capped tungsten halogen lamp tungsten halogen lamp having a single cap or base 1.3.3double-capped tungsten halogen lamp tungsten halogen lamp having a cap or base on each end of the lamp 1.3.4outer envelope transparent or translucent enclosure containing a tungsten halogen light source. NOTE The enclosure can also consist of a reflector with integral front cover. 1.3.5 rated value quantity value for a characteristic of a lamp for specified operating conditions. The value and the conditions are specified in this standard, or assigned by the manufacturer or responsible vendor NOTE In this standard, a number of data sheets still refer, in the French text, to "nominales" values, instead of "assignées", as an outdated translation of "rated". 1.3.6rated voltage voltage or voltage range specified in this standard or assigned by the manufacturer or responsible vendorNOTE If lamps are marked with a voltage range, they are appropriate for use on any supply voltage within that range. 1.3.7test voltage rated voltage unless otherwise specified NOTE If lamps are marked with a voltage range, the test voltage is the mean of the voltage range, unless otherwise specified.1.3.8rated wattage wattage specified in this standard or assigned by the manufacturer or responsible vendor
– 12 –60357 © CEI: 20021.3.9courant assignécourant spécifié dans la présente norme ou fixé par le fabricant ou le vendeur responsable1.3.10courant d’essaicourant assigné, sauf spécification contraire1.3.11température maximale du pincementtempérature maximale que les composants situés dans le pincement ou le scellement sontconçus pour supporter pendant la durée de vie prévue de la lampe1.3.12flux lumineux initialflux lumineux d’une lampe après vieillissement1.3.13flux lumineux assignévaleur du flux lumineux initial de la lampe déclaré par le fabricant ou le vendeur responsable,dans des conditions de fonctionnement de la lampe spécifiées1.3.14maintien du flux lumineuxrapport du flux lumineux d’une lampe, à un moment donné de sa vie, à son flux lumineuxinitial, dans des conditions de fonctionnement spécifiéesNOTECe rapport s’exprime généralement en pourcentage.1.3.15maintien de l’intensité dans l’axe du faisceaurapport de l’intensité dans l’axe du faisceau d’une lampe à réflecteur, à un moment donné desa vie, à son intensité initiale dans l’axe du faisceau, dans des conditions de fonctionnementde la lampe spécifiéesNOTECe rapport s’exprime généralement en pourcentage.1.3.16durée de vie moyennenombre d’heures de fonctionnement, dans des conditions d’essai spécifiées, au bout duquel50 % des lampes issues d’un groupe représentatif restent opérationnelles (durée à 50 % dedéfaillances)1.3.17durée de vie moyenne assignéedurée de vie moyenne déclarée par le fabricant ou le vendeur responsableNOTELa durée de vie moyenne assignée n’est pas nécessairement la durée de vie moyenne de toutes leslampes prises individuellement. Elle ne peut être utilisée qu’à titre de comparaison, étant donné que dans lapratique les conditions de fonctionnement peuvent différer des conditions spécifiées pour les essais de durée.1.3.18fin de durée de vieinstant où la lampe sous tension cesse d’émettre de la lumière
60357 © IEC:2002– 13 –1.3.9rated currentcurrent specified in this standard or assigned by the manufacturer or responsible vendor1.3.10test currentrated current unless otherwise specified1.3.11maximum pinch temperaturemaximum temperature which the components in the pinch/seal of a lamp are designed to withstandover the expected life of the lamp1.3.12initial luminous fluxthe luminous flux of a lamp after ageing1.3.13rated luminous fluxthe value of the initial luminous flux of the lamp declared by the manufacturer or responsiblevendor, the lamp being operated under specified conditions1.3.14lumen maintenancethe ratio of the luminous flux of a lamp at a given time in its life to its initial luminous flux, thelamp being operated under specified conditionsNOTEThis ratio is generally expressed as a percen
...
Questions, Comments and Discussion
Ask us and Technical Secretary will try to provide an answer. You can facilitate discussion about the standard in here.